Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.2 Cr+₹7.7 L (6.74%)Rejected-AOC | ₹1.2 Cr+₹7.7 L (6.74%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.3 Cr+₹14.3 L (12.5%)Rejected-AOC | ₹1.3 Cr+₹14.3 L (12.5%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
3 Jun 2021, 6:00 pmClosed
CWE Dehradun
CWE Dehradun
ADDN/ALTN OF MES CIV QTR AT ROBERT LINE AND SULVA LINE AT DEHRADUN.
2021_MES_424399_3
9601/DDN/38/E8
Open Tender
Civil Works
Item Rate
270 days
Dehradun
As per tender doc
8 documents required · 8 mandatory
₹1,000
GE(P) Dehradun
₹2.1 L
Yes
16 Jul 2021
6 May 2021
5 Jun 2021
6 May 2021
3 Jun 2021
21 May 2021
Amount
Demolition of brick work or stone boulder masonry build in cement mortar including all quoins, arches, pillars, etc. Complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and fair complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound, surface finished even and smooth complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately as supply only.
M & L for 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair including taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4 mixed (if ordered) with water proofing compound, surface finished even and smooth including taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc. complete. Note : Water proofing compound shall be measured and paid separately as supply only.
M & L for applying 1 to 1.5 mm thick of Wall care Putty after preparation of old/new surfaces of wall as per manufacturer’s instruction complete all as specified and directed.
M & L for preparing old decorated plastered or un-plastered surfaces of wall, pillasters, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and washing down with water, filing small holes/undulations by putty including complete removal of existing treatment complete all as specified and directed.
M & L for preparing of old decorated surfaces of wall, pillasters, cornices etc by washing, rubbing down & stopping etc and applying two coat of oil bound distemper complete all as specified and directed.
M & L for preparing of old/new surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall up to double storey building and applying two coat of first quality exterior emulsion weather coat paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for complete removal of old painted surfaces of wall with scraping, wire brushing, washing with water and preparation of surfaces up to double storey building and applying two coats first quality exterior emulsion weather coat paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparing old decorated plastered or un-plastered surfaces of ceiling, pillasters, cornices etc and applying one coat of white wash complete all as specified and directed.
M & L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling, surface finished fair and even and applying three coats of white wash including taking down existing cement plaster complete all as specified and directed.
M&L for vitrified ceramic tiles light shed 10 mm thick (square/rectangular) polished, area of each tiles not exc. 0.36 sqm in floor etc. and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for vitrified glazed ceramic tiles 10 mm thick light sheds in vertical surfaces and jointed in neat cement slurry over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling inc cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of the premises complete all as specified and directed.
M&L for non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed.
Description same as per item No 20 above but as in skirting over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for glazed ceramic colour tiles size 450 mm x 350 mm x 7 mm thick on vertical surfaces such as dado, skirting etc over and including 10 mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate 40 mm thick as in leveling course to floors complete all as specified and directed.
Demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor etc. Complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channel and drain including necessary use and waste of form work complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds mitered or stopped ends etc. Complete all as specified and directed.
M&L for hardcore gauge exc 63 mm but not exc 100 mm broken stone or boulders, deposited, spread, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub-base laid in alternate bays, surface finished even and smooth with using extra cement complete.
M & L for pre polished chequred cement concrete tile of size 25 cm x 25 cm and 20 to22 mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M & L for 20 to 25 mm thick machine cut Kota stone slab in flooring or treads of steps pre-polished over and including 20mm thick screed bed in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and mirror polishing complete all as specified and directed. Note:- The size of each stone shall not less than 600 mm x 600 mm cut size, except the location where the balance portion remain less than size as specified above.
Description same as per item No 34 above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for 18 to 20 mm thick machine cut polished granite "black or coloured" stone slab over kitchen platform and similar places over and including 15mm thick screed bed in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match with existing surface complete all as specified and directed.
M&L for 18 to 20 mm thick machine cut polished granite "black or coloured" stone slab as in skirting/dado and similar places over and including 15mm thick rendering in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match with existing surface complete all as specified and directed.
M&L for grinding and polishing to edges and rounding of granite kota or marble slab and smooth finishing complete all as specified and as directed.
Taking down and re-fixing the existing shutter in same opening after easing etc. exc. 1 Sqm but n. exc. 2 Sqm each complete all as specified and directed.
Taking down shutter of any description, n. exc. 1 Sqm each complete all as specified and directed.
All as per item No 40 above but exc. 1 Sqm and n. exc. 2 Sqm each complete.
Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame complete.
All as per item No 42 above but exc. 1.5 Sqm and not exceeding 4 Sqm each complete.
S & F mild steel work as in holdfast, hooks for hanging fans and similar small articles conforming to Fe- 290 Gde-E-165 including necessary welding or fixing nuts and bolts complete all as specified and directed.
S & F second class hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
M & L for preparing wood surfaces and wood based surfaces new or old of any description and girth treating ends of post, back of chowkhats etc area tarred exceeding 0.1 Sqm but not exceeding 0.5 Sqm each and treated with tar or coal tar black paint complete all as specified and directed.
M & L for preparing steel surfaces and treating small article such as hold fast etc area not exceeding 0.1 Sqm each and treated with tar or coal tar black paint complete all as specified and directed.
S & F 35mm thick 2nd class hard wood factory made plain, framed paneled shutter (any number of panels) with panels of 12 mm made grade BWR plywood. The rail and stile as per IS-1003 (Pat-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S & F 30 mm thick second class hardwood glazed and Skelton factory made window/ventilator shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass / gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24(b) and complete all as specified and directed.
S&F FRP door frame of size 100mm x 50 mm made out of 3mm coloured pre laminated FRP sheet with UV grade polyester resin complete all as specified and directed.
S &F 30 mm thick FRP door shutters with UV grade polyester resin with minimum 3 mm thick coloured pre-laminated FRP sheet fixed on both sides complete all as specified and directed.
M&L for mild steel (Fe-410-W ) framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ball bearing etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door complete all as specified and directed.
S&F mild steel, plain, black sheet 0.80 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitered angles, etc. as required complete all as specified and directed.
S & F factory made steel window with side hung shutters including projecting/box/pin type hinges with steel handle, steel peg stay, tower bolt etc. complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F factory made steel window with side hung shutters including projecting/box/pin type hinges with steel handle, steel peg stay, tower bolt etc. complete without glazing bars, dovetailed or welded complete all as specified and directed.
S & F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc. complete all as specified and directed.
S&F pre laminated particle board exterior grade,18/19 mm thick pre-laminated one side with decorative choice lamination and other side balancing white lamination fixed with screw timber framework all as specified and directed.
S&F hasp and staple size of 100 mm, mild steel, wire type, stove enameled black, including bolt to hinge plate and fixed with screws all as specified and directed.
S&F magnetic catcher and striking plate including letting in complete all as specified and directed.
S&F continuous (PIANO) hinges, mild steel, bright finish or electro galvanised. 30 mm width of flaps (when open) complete all as specified as directed.
S & F aluminium anodised barrel tower bolts of extruded section and fixed complete for 150 mm long complete all as specified and directed.
All as per item No. 63 above but 200 mm dia bore tubing.
S & F butt hinges, medium weight, cold rolled mild steel complete for the 50 mm size complete all as specified and directed.
All as per item No. 65 above but 75 mm size.
All as per item No. 65 above but 100 mm size.
S & F aluminium handles cast type, anodised complete for the following 100 mm size
All as per item No. 68 above but 125 mm size.
S & F 300 mm mild steel sliding door bolt plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
M & L floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 150 mm complete all as specified and directed.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge block, shaped door and window stops and the like including all labours articles n. exc. 200 cum each complete all as specified and directed.
S & F 300 mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint on old wooden surfaces of any description over 10 cm width or girth including preparation with complete removal of existing treatment complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and directed.
Taking down water proofing topping, roughning surface of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, etc complete all as specified and directed.
M & L for water proofing topping, Brushing neat cement slurry with 3 Kg of cement per Sqm complete all as specified and directed.
M & L repair and water proofing treatment to terrace of roof Cutting out cracks to 'V' section in existing roofs or terrace where cracks > 2.5 mm wide, cleaning out, wetting grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) providing cement concrete in roof, curves or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L for 15 mm thick plaster in one layer in CM (1:3) over concrete roof padding, cement mortar mixed with cement mortar complete all as specified and directed.
M&L for chemical compound PIDIPROOF LW of DR FIXIT of PIDILITE INDUSTRIES LTD mixed in proportion 200 millilitre per 50 Kg cement or STP No. 1 (Liquid) of STP Ltd. in proportion 200 ml per 50 Kg cement as per manufacturers instructions laid when concrete is still green and finishing the surface fair and even without using extra cement complete all as specified and directed.
M & L water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer all as specified and directed complete.
(i) Properly cleaning and drying concrete surfaces.
(ii) Applying a coat of oxidised bitumen based solvent primer 0.3 Kg / Sqm
(iii) Laying 3 mm thick APP modified water proofing membrane with 100 mm over laps sealed and bounded to the surfaces by 'torchon' method.
(iv) Applying coat of bitiminous aluminium paint @ 200 Gram / Sq M (minimum) in two coats complete all as specified and directed.
Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering complete. Note:- Opening of existing wind tie where required for taking down of AC sheet is included in the rate quoted against this item.
S & F pre- painted galvalume aluminum zink coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw complete all as specified and directed. Note:- The profile of sheet shall be as per sample kept in GE's office.
S & F pre- painted galvalume aluminum zink coating GI based plain steel sheet 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw complete all as specified and directed. Note:- The profile of sheet shall be as per sample kept in GE's office.
Dismantling timber scantling as in fillets, rails, posts, rafters, purlines etc under 40 Sqcm in section complete all as specified and directed.
Dismantling timber scantling 40 Sqcm framed work and over in section , in any position complete all as specified and directed.
M & L for 2nd class hard wood plain fillets exc 13 and not exc 25 sqcm, square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M & L for 2nd class hard wood plain fillets exc 06 and not exc 13 sqcm, square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
M & L for 2nd class hard wood timber framed and fixed in scantling complete all as specified and directed
S & F mild steel(Fe-410-W) work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleat etc. complete all as specified and directed.
S & F mild steel work as in main and cross beam, hip and jack rafters, purlins etc. fixed with angle cleat or other connecting plate complete confirming to Fe – 410W complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
All as per item No. 94 above but one coat on old painted steel surfaces.
Dismantling wall and ceiling boards (fibre, pulps, insulation etc.) or insulation boards/slabs/blanket, any thickness, including cover fillets complete all as specified and as directed.
S & F 600x600mmx4mm thick 'E' board class ic as in false ceiling including supply and fixing 'Tee" grid frame work made of special section of MS galvanized sheet 0.30mm thick, bottom portion painted with cellular nitro painting, consisting angle cleats of size 25mm wide 1.6mm thick with flag fixed to RCC ceiling with dash fastener or wrapping the suspending wire around the existing wooden/steel purlin/rafter for suspending grid frame work of size 600mmx600mm suspended with 02 Nos, 1.60mm dia GI wire @ 600mm C/C on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 37mm x24mmx0.60mm thick, cross runner tee 37mmx24mmx0.60mm and. Perimeter angle 24mmx24mmx0.50mm thick shall be fixed to wall with GI screw of 40mm long @ 450mm C/C along the perimeter of wall including or wall including applying two coats of distemper oil emulsion all as per manufacturer's instruction complete all as specified and directed.;
S&F Harrison rails with brackets, mild steel chromium plated ,stops, rollers etc all as specified and directed.
Taking up or down existing steel tubing and connection including removal to store complete for the 15mm dia bore pipe.
All as per item No. 99 aobove but 20 mm dia bore tubing.
Supplying, fixing, Medium Gde jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors complete for 15mm dia bore complete all as specified and directed.
All as per item No. 101 above but 20 mm dia bore tubing.
Re fixing only old steel water tubing & connection in new or old position fixed to wall, ceiling or laid in floors including necessary cutting & making of new threads for fixing of new fittings such as elbows, tees, sockets, union, , reducer, etc as required complete for 15 mm dia bore complete all as specified and directed.
All as per item No. 103 above but 20 mm dia bore tubing.
Supply & fixing only PVC connection 15 mm dia 600 mm long with bras fly nut at both ends complete all as specified and directed.
S&F in repair sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including cantilever brackets of suitable angle iron, CP brass waste coupling ,superior quality PVC waste pipe and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including bracket with 32 mm dia PVC pipe 600 mm long complete all as specified and directed.
S & F in repair PVC (SWR) pipe single socketed in any length with rubber ring, fixed on wall complete for the 75 mm bore size complete all as specified and directed.
All as per item No. 109 above but 110 mm dia bore pipe.
S & Fin repair PVC (SWR) pipe single socketed in any length with rubber ring,joints laid in trenches complete for the 75 mm bore sizes complete all as specified and directed.
All as per item No. 111 above but 110 mm dia bore pipe.
S & F in repair PVC (SWR) bend, 'T' socket reducer etc complete for following 75 mm bore sizes:-
All as per item No. 113 above but 110 mm dia bore pipe.
S & F PVC (SWR) vent cowl of dia 110 mm complete all as specified and directed.
S & F in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed. Note :- Pillar tape/WHB mixer shall be measured as supply only under respective item
S&F in repair 15 mm dia pillar tap fancy type brass chromium plated with capstan heads, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shank and fly nuts complete all as specified and directed.
S&F CP mixer in repair brass hot & cold 15 mm dia wall mixer for mixing hot and cold water with shower provn with connecting legs &flanges complete all as specified and directed.
S&F in repair 15 mm dia centre hole wash basin mixer brass chromium plated, long shank, fancy type for mixing hot & cold water with capstan heads, screwed down for 15 mm GI pipe complete all as specified and directed.
S&F in repair CP brass hot & cold 15 mm bore sink mixer with swinging casted spout (wall mounted) with connecting legs of flanges complete all as specified and directed.
S & F in repair fancy type brass chromium plated shower rose with shower arms with swivel joints including fixing to steel pipe of 15 mm dia or union, complete all as specified and directed.
S & F in repair 15 mm dia bore chromium plated concealed stop cock fancy type, complete all as specified and directed.
S & F in repair brass chromium plated with long sunk and cup 15 mm dia fancy type crewed for iron pipe or brass ferrule, complete all as specified and directed.
S & F in repair 15 mm bore bib taps fancy type, chromium plated cast copper alloy long body , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S & F PTMT grating square 150mm size complete fixed in repair complete all as specified and directed.
S&F beveled edge mirror mounted on 6mm thick AC bldg board to fixed to wooden plug with CP brackets screw fixed, fixed in repair complete all as specified and directed.
S&F in repairs brass chromium plated towel rail, 20mm dia 'D' type 60cm long between flanges complete all as specified and directed.
Disconnection of existing tank, set aside (or lowering if required) for cleaning & removing all scale & dirt etc from existing tanks and mouths of circulating pipes of any description & washing down in the manner as specified in particular specification including reconnecting and re-fixing in position and putting date of cleaning on tank/near parapet or wall by paint for Capacity exceeding 250 litres but not exceeding 5000 litres complete all as specified and directed.
S&F in repair 500 litres rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
S & F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm bore outlet complete complete all as specified and directed.
S & F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 15 mm bore size (Minimum weight 142 gms), complete all as specified and directed.
S & F 20 mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete all as specified and directed.
M & L for providing pre-cast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab of manholes, septic tank, soak well etc set in cement mortar 1:4 plain fair faces including chamfered weathering, throating etc complete all as specified and directed.
M&L for use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of fair finished surfaces complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
M & L for RCC (1:2:4) type B1 using 20 mm graded stone aggregate as in beam, cantilevers, lintel chajjas complete all as specified and directed.
S & F mild steel TMT bar 8 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S & F mild steel TMT bar 6 to 8 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M & L for anti-termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution ) @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
S&F salt glazed stoneware drain pipes internal dia of pipe 150 mm laid in trenches and jointed complete all as specified and directed.
M&L 150 mm dia concrete bed salt glazed stoneware drain pipes internal dia of pipe including packing under, haunching against the side of pipe after they are laid and tested complete all as specified and directed.
M&L 150 mm dia cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch ,channel (1/2 round or 3/4 section) in cement concrete 1:2:4 Type B-1 smooth finish and reforming benching as required all as specified and directed
M&L for Excavation in trenches in soft/loose soil not exc.1.5 m wide and not exc. 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of underground cable, foundation of pole etc and n exc 1.5 m in depth and getting out all as specified and directed
All as per item No. 144 above but for each additional 1.5 m or part therefore in depth beyond the first 1.5 m complete all as specified and directed.
M&L for removing soil excavated material not exc 50 m and depositing where directed at a level 1.5 m above the starting point complete all as specified and directed.
M&L for returning &Filling in soft/loose soil including ,spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Supply only water proofing compound as per IS
M&L in replacement in existing point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following. (Note: Colour code shall be maintained as per IE rule) Note :- Cost of cutting chases in chases n.exc 10 cm width in wall and ceiling and making good with CM (1:4) is included in the quoted rate.
One light point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two way switch
All as per item No 149 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
M&L for new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by the Eng.-in-charge of the following. Note: Colour code shall be maintained as per IE rule. Note :- Cost of cutting chases in chases n.exc 10 cm width in wall and ceiling and making good with CM (1:4) is included in the quoted rate.
One light point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on independent board
All as per item No 151.00 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete all as specified and directed.
S&F bell switch piano flush button type 5 Amp complete all as specified and directed.
S&F ding dong bell AC 230 V single pole complete all as specified and directed.
S&F switch piano flush button type 5 Amp SP 2 way complete 250 V AC complete all as specified and directed.
S&F stepped type electronic fan regulator flush type two module 400 Watt on the existing phenolic laminated sheet etc as required complete all as specified and directed.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified and directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings.250 V AC complete all as specified and directed.
M&L in sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multi stranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multi stranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed including taking down old sub main wiring complete all as specified and directed.
Taking down & Re fix Exhaust Fan any size/sweep single phase 230 volts including servicing, painting of Exhaust fan and connecting with twisted three cord flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan complete all as specified and directed.
S&F in replacement sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed. (Note:- MCBs shall be measured and paid separately).
Supply & fixing in replacement and Testing TP & N Vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 250 Amp Copper bus bar for each phase with two neutral bar & two earthbar and cable ties for cable management including Provision of MCCB 63 Amps,ICs=100%ICu, 16KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Eng-in-charge including taking out old unserviceable DB and removing from site and making good of disturbed surface complete all as specified and directed. (Note :- MCB/ MCCB shall be measured and paid separately) . Note :- Make of DBs shall be as per make of MCCB/MCB to be incorporated.
S&F MCB SPN 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed .
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed .
S&F MCCB 415 Volt 16 KA 3 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting . Make: (i) Philips cat part No TMC1001xT LED 13-20w WH(Tube Batten) MAS LED 1200mm 18W-865-T-81 (ii) Havells Cat Part No REGAL BATTEN 8UPTO 1X20W SSBS WH( Batten)PHOTONULTRAE2.01213T118WLED 865 SPC (iii) WIPRO CAT PART No WIO921208 (Tube Batten) LL12-181-650 (Tube)
S&F wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting . Make: (i) Philips cat part No TMC1001xT LED 13-20w WH(Tube Batten) MAS LED 1200mm 18W-865-T-81 (ii) Wipro Cat part No WI0921208 (Tube Batten) LL13-181-650 (Tube)/ (iii) Havells Cat Part No REGAL BATTEN 8UPTO 1X20W SSBS WH( Batten) PHOTONULTRAE2.01213T118WLED 865 SPC.
S&F mirror light decorative compact luminaries with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed. .Make (i) Phillips Cat No BN021LED 12S 6500 PSU GR. (ii) Havells Cat No LHESABP7IN1W009 9W (iii) Wipro Cat No MAGMA LED 10 Watt.
S&F LED light fitting decorative wall mounting cast aluminium Polycarbonate paint bracket suitable for 5 watts LED bulb with frosted glass with and including one no 5 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed. Make (i) Philips stellar bright high wattage 12W (ii) Havells Cat No LHEAABP 71L1W012 (iii) C&S Cat No CORONA-RND-18 W/W
Taking down & Re fix ceiling Fan of any type and sweep single phase 230 volts with down rod , canopy, blades etc including connecting with twisted three cord flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan after greasing/oiling, painting etc and writing MES NO on fan complete all as specified and directed.
Supply & fix ceiling Fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan complete all as specified and directed .
S&F Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two Nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed .
S&F air ventilation fan metallic body 300mm, 900 RPM with louvers, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame hold fastener, bolt, washer etc including connection with twisted white three core flexible copper multi stranded conductor cable from ceiling rose to connector complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead with GI wire of size 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI wire of 4 mm dia for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I, and all as directed and specified Note: (i) Cost of GI wire 4 sqmm and 15mm dia GI pipe medium grade upto length 7.5 mtr deemed included in the quoted rate. (ii) If the desired earth resisitance is not found within permissible limit, item shall be re-done by contractor at no extra cost.
Supply and Fixing in replacement Integral LED Street Light Luminaries comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 25 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI bracket made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed. Make i) Philips Cat No BRP-046 LED 30CW MR S1 PSU GR (25 W 3000 Lumens street lights. (ii) Havells Cat No ENDURAPEARLS L25WLED 7S7SASYTOPCMP. (iii) C&S Cat No INDUS/25W/LS.
supplying, laying in replacement, jointing and testing LT underground cable of size 16sqmm4 core heavy duty, 1100 Volts, PVC insulated and sheathed, armoured with multi-stranded aluminium conductor cable conforming to latest IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends all complete all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
All as per item No. 181.00 above but of size 10sqmm 2 core.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
S&F decorative knob for cup board/kitchen cabinet all as directed by Engineer- in - charge.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
M/s BK Enterprices
M/S SETHI BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .