Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹88.2 LAccepted-AOC NO 1 INSPECTOR QUARTERS TSP 6TH BATTALION CAMPUS NEW NATHAM ROAD MADURAI 625 014 | MADURAI | TAMIL NADU | 625001 | L 1 | Accepted-AOC Lowest one accepted work order issued on 08.09.2023 | |
| 2 | L 2₹94.3 L+₹6.1 L (6.95%)Rejected-AOC NO 3 109 MIDDLE STREET ELANGAKURICHY POST TRICHY DISTRICT 621 302 | ELANGAKURICHY | TRICHY | TAMIL NADU | 621302 | L 2 | Rejected-AOC Second lowest Unsuccessful tender EMD amount to be refund | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹1.0 Cr
EMD Value
₹61,900
Closing Date
10 Jul 2023, 6:00 pmClosed
Superintending Engineer South Circle TNPHC Ltd
Tamil Nadu Police Housing Corporation Limited No I Inspector Quarters TSP VI Battalion Campus New Natham Road Madurai 625014
Carrying Out of Special repair works for 18 Nos. of SI quarters at TSP 1st Battalion Campus Trichy in Trichy City
2023_TNPHC_334878_1
SE/SC No 15/2023-2024-2
Open Tender
Civil Works
Lump-sum
245 days
TRICHY IN TRICHY CITY
Refer tender documents
7 documents required · 7 mandatory
₹0
₹61,900
11 Sept 2023
4 Jul 2023
12 Jul 2023
4 Jul 2023
10 Jul 2023
4 Jul 2023
Amount
1.1) Earth work excavation for foundation in all soils (including refilling) a. 0 to 2 mt.
31) Weathering course over roof slab with proportion of brick jelly 20mm to lime (32:12 1/2) by volume
37.1) White washing 3 coats (slaked)
52) Supplying, laying, fixing and jointing the following dia PVC pipes as per ASTM D-1785 of schedule 40 including the cost of suitable PVC/GI/GM specials a. 32 mm dia
b. 25 mm dia
Electrical arrangements 69) Supplying and fixing of 15 Amps 3 pin Power plug socket
74) Charges for assembling and fixing of ceiling "Fan"
81) Supplying and fixing of meter cupboard with best Country wood double leaves shutters
Annexure 2.1.3) Supplying and filling in foundation and basement with Crushed stone sand
3.1.1) C.C.1:5:10 using 40mm size HBSJ for Foundation & Basement using crushed stone sand
3.2.1) P.C.C. 1:2:4 using 20mm size HBSJ for Foundation & Basement and other similar works using crushed stone sand with Admixture
6.6.1) Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture
8.4.1) Standardized Concrete mix M20 Grade using crushed stone sand with Admixture a. In Ground Floor
9.6.1) Brick work in C.M. 1:6 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
10.6.1) Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7 cm (8 ¾"x4 ¼ "x2 ¾") 110 mm tk (B.P.) using crushed stone sand with Admixture a. In Foundation and basement
b. In Ground Floor
14.2.3) Precast Cupboard slab 40mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand with Admixture 40mm thick a. In Foundation & Basement
18.1) Formwork using M.S.Sheet b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
21.5.2) Supplying and fixing of soild UPVC door shutter with frame
23.2.1) Supplying and fixing of 4mm thick pin headed glass panels with Aluminium beedings
23.1.1) T.W.single leaf door shutter using 9mm thick phenol bonded BWR grade plywood with brass screws. Suitable for door of size a. 900 x 2100mm
28.1) Finishing the top of flooring in C.M. 1:4, 20mm thick. using crushed stone sand with Admixture
29.8.1) Supplying and fixing of Glazed tiles using Grout (Tile Joint Filler) using crushed stone sand
29.9.1) Supplying and laying of Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler). using crushed stone sand
32.1.1) Pressed tiles (23cmx23cmx20mm thick) mixed with water proofing compound @ 2% by weight of cement using crushed stone sand
32.1.4) Pointing the pressed tiles with C.M. 1:3 mixed with WPC using crushed stone sand
33.1) Plastering in C.M. 1:5, 12 mm tk. using crushed stone sand with Admixture
34.1) Plastering in C.M. 1:4, 12 mm tk. using crushed stone sand with Admixture
35.2) Spl. Ceiling plastering in C.M 1:3, 10 mm tk. using crushed stone sand with Admixture
37.2) White washing two coats for old ceiling surfaces
38.4.1) Two coat of Oil Bound Distemper over the primer coat of white cement
38.4.3) Painting the old wall with one coat of Oil Bound Distemper over the Existing wall surfaces
38.6) Primer coat using one coat of white cement over the cement plastered/ concrete new wall surfaces or other similar works
40.1) Two coats of painting over the old wood work including Removing old paint from doors, windows & wood works by manual labour
41.1) Two coats of painting over the old iron work and other similar works including Removing old paint from iron surface with sand paper
43.1) Supplying, Fabricating and fixing of Mild steel / RTS grills (without cement slurry wash) reinforcement for all sizes of rods
44.6) Supplying and fixing of PVC SWR 110 mm dia with ISI mark type-A for rain water down fall pipe
50.6.1) Precast slab 50 mm tk.in C.C.1:3:6 mixed with fibre using crushed stone sand
51.1) Supplying and fixing of HDPE water tank 700 lit capacity with ISI mark
52.1.1) Supplying and fixing of CPVC Pipe 20mm dia for hot water line (Fully concealed in walls)
53.5) Supplying and fixing of Wash hand basin (White without Pedastal type) of size 550 mm x 400 mm (22"x16")
54.1.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (long body)
54.2.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (Short body)
56.3.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade 'P' or 'S' trap - in G.F. using crushed stone sand
58.3) Supplying and fixing of PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia
58.5) Supplying and fixing of PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl a) 110mm dia PVC SWR pipe of 3m with required PVC cowl & PVC specials etc.,
60.1) Supplying and fixing of PVC Nahani trap (4way/2way)
61.1.1) Supplying and fixing of UPVC Non Pressure Pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a) 110mm dia UPVC Non Pressure pipe
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose with bakelite battern holder
c. Calling bell point with Buzzer/Calling bell
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan Point
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Switch Board Itself.
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Convenient Places.
75.1.2) Supplying and delivery of fan with electronic dimmer with ISI mark a) 48" (1200mm) sweep
75.1.3) Supplying and fixing of Fan Step Regulator 100W - 1 Module - Lower end
77.5) Run off 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed
77.6) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed.
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed
87.2) Supplying and fixing of 20 Amps DP plug and socket in sheet enclosure with 32A DP MCB in Flush with wall with earth connection (For AC Plug)
100) Supplying and fixing of 9 watts LED Bulb
101) Supplying and fixing of 25 watts LED with street light fittings
101.1) Supplying of 20 feet street light pole complete set with necessary accessories such as 2" dia MS pipe of 3mm thick 10 feet height and 1½" dia MS pipe of 3mm tk 10 feet height etc.,
102) Supplying and fixing of 4'18 watts crystal LED tube light fittings
105.1) Run off main 4 wires of 4 Sq mm. (EB service connection)
106) Supplying and fixing of 5 Amps 5 Pin Flush type wall socket
107) Supplying and fixing of 5 Amps Flush type wall switch
110) Supplying and fixing of Single Pole MCB 6A to 32A, 10KA
111) Supply and fixing of 6 way SP DB of 16A / way with 16A DP switch with metal clad of 500V (side handle) with fuse and neutral on suitable TW board with PWD earth connection only
114) Supplying and delivery of following PVC Aluminium armoured LTUG cable a) 2 core 10 Sqmm PVC Aluminium armoured LTUG cable
115) Labour charges for laying of 3.5 core 35 Sqmm PVC Aluminium armoured LTUG cable below ground level
125) Supplying and fixing of 20mm dia UPVC pipe above Ground level
144) Supplying and fixing of CP Shower Arm with Overhead Shower Rose
145) Supplying and fixing of CP Angle valve
344.2) Supplying and fixing of Bevelled Edge Mirror of size 500x400x5.5mm
361.1) Supplying and laying of Concrete designer tiles flooring in C.M. 1:3 (one of cement and three of crushed stone sand) 20mm thick
378.2) Supplying and fixing of Vitrified tiles (Ivory) in CM 1:3, 20mm tk using crushed stone sand
379.6.1) Supplying and fixing of Granite tile of size 2'x1', 10mm tk (Jet Black) for Kitchen hearth slab in cm 1:3, 12mm tk using crushed stone sand a. In Ground Floor
383.2) Providing single nosing to the edges of granite slab
448.2) Supplying and fixing of PVC Tee with end cap of 32mm dia
571) Supplying and fixing of Colour Galvalume sheet roofing 0.47mm thick
572) Supplying fabrication and fixing in position of mild steel angles for truss including cost of all materials and labour charges
796.2) Painting the old outer walls with one coat of Exterior emulsion paint without primer and including thorough scrapping
800.1) Dismantling, clearing away and carefully stacking materials useful for re-use of Reinforcement cement concrete by manual / by using deploying machineries
800.2) Dismantling, clearing away and carefully stacking materials useful for re-use of Pressed Tiles & Weathering Course
800.3) Chipping of concrete and roughening the surface
800.4.1) Dismantling clearing away and carefully stacking materials useful for reuse of brick masonry in cement mortar walls a) Under 3.00m height
800.5) Clean removal of Floor finish and dadooing walls in cement mortar with Mosaic tiles / Glazed Tiles / Clay Tiles / Cuddapah slabs
800.6) Dismantling clearing away of Indian Water Closet including labour charges etc.,
800.7) Removing of damaged Plinth Protection and Chamber cover slab
800.8) Peeled off concrete portion redoing with Micro concreting including cost of material and labour charges for rust removal and applying of water proofing compound and Epoxy paint coating in corrosive steel portion
800.9) Dismantling clearing away and carefully stacking materials useful for reuse for Door and windows
800.10) Cleaning of Septic tank & Chamber including lorry fright charges loading and unloading outside the City limit minimum 5 km from site and remove the blockages in line
M.Mohamed Hussain
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_397839.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .