| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAdmitted-Fee/PreQual/Technical/Finance C O SACHINDRA MAJUMDER ASSAMPARA 0 RANIR BAZAR WEST TRIPURA TRIPURA 799035 | WEST TRIPURA | TRIPURA | 799035 | ₹19.0 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹19.0 L+₹6,440 (0.34%)Admitted-Fee/PreQual/Technical/Finance DINADAYAL ASRAM PARA A D NAGAR AGARTALA TRIPURA WEST PIN 799003 | WEST TRIPURA | TRIPURA | 799003 | ₹19.0 L+₹6,440 (0.34%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹20.3 L+₹1.4 L (7.24%)Admitted-Fee/PreQual/Technical/Finance NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹20.3 L+₹1.4 L (7.24%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Eastern Commerce L3 | CHANDAN MAJUMDER L1 | S D COOL TECH L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit including batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 28 | Nos | 54,900 ₹15,37,200 | 54,215 ₹15,18,020 | 53,400 ₹14,95,200 Lowest |
| 2.00 | Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mountingconforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 4 | Nos | 41,900 ₹1,67,600 | 41,550 ₹1,66,200 Lowest | 42,300 ₹1,69,200 |
| 3.00 | Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. | 32 | Nos | 2,500 ₹80,000 | 1,550 ₹49,600 Lowest | 2,000 ₹64,000 |
| 4.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 32 | Nos | 1,400 ₹44,800 | 1,450 ₹46,400 | 1,200 ₹38,400 Lowest |
| 5.00 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. | 96 | Mtr | 1,200 ₹1,15,200 | 950 ₹91,200 | 800 ₹76,800 Lowest |
| 6.00 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 96 | Mtr | 180 ₹17,280 | 75 ₹7,200 | 10 ₹960 Lowest |
| 7.00 | Providing & Fittin fixing of best quality 25 mm dia UPVC pipe including necessary clamping for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 270 | Mtr | 270 ₹72,900 | 70 ₹18,900 Lowest | 220 ₹59,400 |
Tender Value
₹22.2 L
EMD Value
₹44,410
Closing Date
5 Jun 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division
Providing Installation Commissioning Air Conditioning machine in the Newly constructed Building the Court Kailashahar Unakoti during the year 202627
2026_CEPWD_73134_1
27 _EE__DNIeT_MECH.DIVN _2627
Open Tender
Electrical Works
Works
120 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹44,410
17 Jun 2026
20 May 2026
5 Jun 2026
20 May 2026
5 Jun 2026
20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit including batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 28 | Nos | - | - |
| 2 | Providing of Split type Hi wall 1.50 TR(rated cooling capacity should not be less than 4500 kcal/hr or 18000 BTU/hr or 5250 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mountingconforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply maximum current drawn 11.0 ampere including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 4 | Nos | - | - |
| 3 | Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. | 32 | Nos | - | - |
| 4 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 32 | Nos | - | - |
| 5 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. | 96 | Mtr | - | - |
| 6 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 96 | Mtr | - | - |
| 7 | Providing & Fittin fixing of best quality 25 mm dia UPVC pipe including necessary clamping for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 270 | Mtr | - | - |
stage.html
html • 0.02 MB
finance_74429.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_74429.xls
BOQ • 0.23 MB
DNIT.pdf
Tender Documents • 2.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .