Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.5 LAccepted-AOC VILLAGE DOHAL PO PATTI TEHSIL PALAMPUR DISTRICT KANGRA | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹93.2 L+₹34,875 (0.38%)Rejected-Finance V P O SEHAL TEHSIL BAIJNATH DISTT KANGRA H P | MANDI | HIMACHAL PRADESH | 175013 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹98.7 L+₹5.8 L (6.28%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹1.0 Cr+₹12.1 L (13.0%)Rejected-Finance LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹1.1 Cr+₹15.0 L (16.2%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹75.7 L
EMD Value
₹1.1 L
Closing Date
21 Feb 2023, 5:00 pmClosed
Execurtive Engineer JS Division Padhar
Executive Engineer JS Division Padhar
SH Supply and Installation of Submersible Pumping Machinery Ist stage 2x75 BHP and 2nd stage 2x90 BHP, Rising Main 65 mm dia Laying, Jointing, Testing and Carriage of GI pipe flanged with butt welding Gravity Main 80mm dia 1280 Rmt C O Pump H
2023_HPIPH_68936_1
11591 -630 dated 15/02/2023
Open Tender
Pumps/Motors
Item Rate
365 days
Prashar
Please refer Tender documents.
10 documents required · 10 mandatory
₹800
EE Padhar
₹1.1 L
Yes
3 Apr 2023
15 Feb 2023
22 Feb 2023
15 Feb 2023
21 Feb 2023
15 Feb 2023
Amount
Centrifugal Pump Set Ist Stage:- Supply of horizantial spindle, horizantial/ dial split casing/and suction ( black pull out arrangements) single/double/multistage centrifugal pump or combination of pumps, in series/parallel of KSB/ Mathar & Platt /Jyoti/ Kirloskar/BE/Maxflow/ Beaconweir Sabar make confirming to BIS:5659-1970) pump (latest with upto date ammendments, read with BIS:9137-1978 ( latest edition) suitable for lifting clear water for under mentioned characterestics with bronze/ suitable alloy, priming funnels, casing ring and shaft mortor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/cast steel plate (base plate from the principal manufactuer of pumping set) to electic induction motor/motors of TEFC motor ISO conforming to IS 12615-2011 with IE-2 standared make such as Kirloskar/ NGEF/ Cromption/ Siemens/Jyoti/ BHEL/ GEC/ABB and suitable for operation on 415(+ /-) 10% volts, 50 cycle per second three phase AC electric supply confirming to BIS 900-1972 and IS: 12615:2011 with IE-2 specification, 2900 RPM (latest upto date ammendments). It should include the cost of bearing nuts and bolts, painting etc. and shall be and suitable for operation on the data given in data sheet.
Supply Installation, Testing and Commissioning of Star Delta Starter /ATS panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 75 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: Aarmation Electric Private Limited/MAS/ELLES/Adle
Star Delta/ATS and Mains Power Contactors of required ratings as per type-2 co- ordination for 75 HP starter
Voltage Protection device to protect panel from over voltage and under voltage
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Electric/MAS/Elle
Main incomer MCCB/MCB of suitable capacity of L&T/Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 (Part & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring Power capacitor, Cooling fan 230 VAC, Control terminal, Bus Bar, i.e.Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control volatge to safegaurd the controlcircuit of all the components from the voltage surges and spikes.
Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)
Providing double flanged cast steel sluice valve, ASA-600 of Leader/BHEL Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class, ASA-600 of Leader/BHEL Kirlosker/Kartar/Kilburn /GLEd/Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments.
Installation of all the items appearing as per the schematic drawing.
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No. 1 A. The size of the various components to be as under:
Suction pipe: One dia higher then the suction of pump offered and suitable
Delivery pipe: One dia higher then the delivery of the pump offered and
Common header: One dia higher then delivery of pump will extend upto 5 mtr.
Providing and laying copper PVC insulated arround power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/ NATIONAL/ GRANDLAY make including all other accessories such as thimbles, flexible pipes, solders.nuts and bolts cable glands etc. laid in pipes or trenches under floor.
Motor side (From switch to starter and starter to motor)
Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with GI plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Centrifugal Pump Set IInd Stage
Supply of horizantial spindle, horizantial/ dial split casing/and suction ( black pull out arrangements) single/double/multistage centrifugal pump or combination of pumps, in series/parallel of KSB/ Mathar & Platt /Jyoti/ Kirloskar/BE/Maxflow/ Beaconweir Sabar make confirming to BIS:5659-1970) pump (latest with upto date ammendments, read with BIS:9137-1978 ( latest edition) suitable for lifting clear water for under mentioned characterestics with bronze/ suitable alloy, priming funnels, casing ring and shaft mortor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/cast steel plate (base plate from the principal manufactuer of pumping set) to coupling electic induction motor/motors of TEFC motor ISO conforming to IS 12615-2011 with IE-2 of standared make such as Kirloskar/ NGEF/ Cromption/ Siemens/Jyoti/ BHEL/ GEC/ABB and suitable for operation on 415(+ /-) 10% volts, 50 cycle per second three phase AC electric supply confirming to BIS 900-1972 and IS: 12615:2011 with IE-2 specification, 2900 RPM (latest upto date ammendments). It should include the cost of bearing nuts and bolts, painting etc. and shall be and suitable for operation on the data given data Sheet.
Supply Installation, Testing and Commissioning of Star Delta Starter /ATS panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 90 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: Aarmation Electric Private Limited/MAS/ELLES/Adle
Star Delta/ATS and Mains Power Contactors of required ratings as per type-2 co- ordination for 75 HP starter
Voltage Protection device to protect panel from over voltage and under voltage
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Electric/MAS/Elle
Main incomer MCCB/MCB of suitable capacity of L&T/Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 (Part & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring Power capacitor, Cooling fan 230 VAC, Control terminal, Bus Bar, i.e.Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control volatge to safegaurd the controlcircuit of all the components from the voltage surges and spikes.
Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)
Providing double flanged cast steel sluice valve, ASA-600 of Leader/BHEL Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class, ASA-600 of Leader/BHEL Kirlosker/Kartar/Kilburn /GLEd/Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments.
Installation of all the items appearing as per the schematic drawing.
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No. 1 A. The size of the various components to be as under:
Suction pipe: One dia higher then the suction of pump offered and suitable
Delivery pipe: One dia higher then the delivery of the pump offered and
Common header: One dia higher then delivery of pump will extend upto 5 mtr.
Providing and laying copper PVC insulated arround power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/ NATIONAL/ GRANDLAY make including all other accessories such as thimbles, flexible pipes, solders.nuts and bolts cable glands etc. laid in pipes or trenches under floor.
Motor side (From switch to starter and starter to motor)
Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with GI plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Rising Main:-
Excavation in foundation and trenches etc. (for pipes and pits) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft / hard rocks where blasting is prohibited in all lifts including trimming and dressing of sides, levelling of bed, to correct excavation and returning the stacked soil after laying, jointing and testing of GI pipes in trenches in 15 cm layers including consolidating each deposited layer by ramming, watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting, timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals fixing caution boards and fencing etc. complete in all respect as per direction of the Engineer-in-Charge.
Providing ,laying, jointing and testing in trenches ( to be levelled to grades) BIS marked API pipe flanged pipe of following diametre conforming to BIS 3183-2007 (latest with upto date amendements) heaving minimum wall thickness as specified below of steel grade API 5 L factory galvanised jointed with flange confirming to table as specified below of BIS 6392-1971 (with latest up to date amendments). Welded at both ends according to relevant BIS standreds and detailed specifications and provided with nuts and bolts of required size 3mm thick compressed asbestos fibre jointing gasket/ synthetic rubber gasketsshould be conforming to relevant BIS code including all short pices bends, tees and other special etc. made for parent tubes and welded with flange of table as applicable for the paricular reach and of approved specification as per site conditions including flushing cleaning painting and hydraulic testing complete to the best satisfaction of the Engineer-in-Charge.
Ist Stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
MS pipe L-290X-42 0 600 600.00 ISO:3183 4.00 34
2nd stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
MS pipe L-290X-42 0 650 650.00 ISO:3183 4.00 38
Laying, jointing and testing in trenches to be levelled to grades IS marked GI (MG) flanged pipes of following diameter conforming to IS 1239-1990 Part-II (with latest up to date amendments) having miniumum wall thickness as for class of pipe specified below jointed with flanges conforming to table as specified below of BIS 6392-1971(latest with up to date amendments) welded at both ends according to relevant BIS standerds and detailed specifications and appended in NIT & provided with nuts and bolts of required sizes, 3 mm thick compressed asbestos fiber gasket or synthetic rubber gasket conforming to relevant BIS codes as given in technical secification i/c all kinds of leads and lifts flanged short piecic bends tees and other specials etc. made from parent tubes and welded with flanges of tables as applicable for the paricular reach and of technical specification appended in NIT as per site conditions including flushing, cleaning painting and hydraulic testing as per direction of Engineer-in-Charge.
Ist stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
GMS Tube(IS:1239-2004) (H) 600 1350 750 GI IS:1239 4.50 28
2nd stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
GMS Tube(IS:1239-2004) (H) 650 1970 1320 GI IS:1239 4.50 28
Ist Stage
Providing ,laying, in trenches to be levelled to grades BIS marked API 5 L grade a factory galvanised with Butt welding of following diametre conforming to BIS 3183-2007 (latest with upto date amendements) having minimum wall thickness as specified below of steel grade A API 5 L jointed with Butt welding including all short pices bends, tees and other specials etc. made from parent tubes and welded with Butt welding as applicable for the paricular reach and approved as per site conditions including flushing, cleaning, painting and hydraulic testing complete to the best satisfaction of the Engineer-in-Charge.
65 mm Dia RD Lengt IS Specification W.T. F.T.
MS Pipe L-290X-42 0 600 600 ISO:3183 4.00 34
2nd stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
MS Pipe L-290X-42 0 650 650 ISO:3183 4.00 38
Laying, jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of GMS pipe of following dia meters confirming to BIS 1239-1990, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
Ist Stage
65 mm Dia RDS Lengt IS Specification W.T. F.T.
GMS Tube(IS:1239-2004) (H) 600 1350 750 GI IS:1239 4.50 28
2nd Stage
65 mm Dia RD Lengt IS Specification W.T. F.T.
GMS Tube(IS:1239-2004) (H) 650 1970 1320 GI IS:1239 4.50 28
Gravity Main
Laying and Jointing in trenches galvanised mild steel tube (light grade) (earth work to measured and paid to separately)
80 mm dia
Providing and fixing brass stop cock wheel valve including housing chamber complete.
80 mm dia
C/O Pump House and Attendand Room 90 HP Stage -IInd
Providing and laying cement concrete 1:6:12 (1cement:6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of from work in foundation and plinth complete in all respect with in all leads and lift and as per the entire satisfaction of Engineer-in Charge.
Random rubble masnory/ polygonal rubble masonry(uncoursed/brought to courses) with hard stone of apporved quailty in foundation &plinth including levelling up with cement concrete 1:6:12(1Cement :6 sand :12greded stone aggregate) in cement mortor 1:6 complete in all respect and as per the direction of Enginer-in-Charge
Brick work using common burunt clay building bricks in supper structure in cement mortor 1:4 ( 1 cement : 4 sand )complete in all respect and as per the direction of Engineer-in-charge.
Providing wood work in frames of door and windows and clerestory windows complete in all respect 2nd class DD Wood.
Providing and fixing panneled glazed or panneled and glazed shutters for doors, windows and clerestory windows, including black enamelled iron butt hinges with necessary screws 40 mm thick 2nd class deodar wood complete in all respect and as per the direction of Engineer-in-Charge
Providing form work with steel plates3.15mm thick welded with Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fairfinish I/c centring , shuttering , strutting and proping etc.with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4m and removal of the same for insitu- reinforced concrete &plain concrete work in :-
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters,buttresses,plinth and string courses and the like.
Flat surfaces such as soffits of suspended fioors roofs landing and the like . Floors etc up to 200mm in thickness.
Beams ,cantilevers, girders and lintels up to floor to level with in all leads and lift.
Providing & Laying cement concrete work 1:2:4 (1 cement 2 sand 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Foundation footings bases of columns and the like and mass concrete.
Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor to level.
Providing and laying cement concrete 1 : 4 : 8 (1Cement : 4 Sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts.
Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level with in all leads and lifts.
6mm cement plaster to ceiling in cement mortar 1:3 (1cement:3sand) complete in all respect and as per the direction of Engineer-in-charge.
15 mm cement plaster in single coat on rough side of brick / concrete / stone walls for interior plastering upto floor two level including arrises internal rounded angles, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortor 1 : 3 (1 Cement : 3 Sand) with in all leads and lifts.
Providing & fixing M.S. grils of required pattern in wooden frame of window etc. with M.S. flats square or round barswith round headedbolts and nuts by screws plan grils complete in all respect and as per the direction of Engineer-in-charge
40 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) laid in one layer with a floating coat of neat cement and curing complete in all leads and lifts.
Boulder filling under floor complete in all respect with in all leads and lifts.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 cement :3sand: 6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth complete in all respect and as per direction of Engineer-in-Charge.
White washing with lime on un-decorated wall surfaces (with two coats) to give an even shade including thoroughty brooming the surface to remove all dirt,dust,mortor dirt and other foreign mattercomplete in all respect and as per direction of Engineer-in-charge
Providing and fixing anodised M.S. sliding door bolts with necessary screws etc.complete in all respect and as per direction of Engineer-in-charge..
Providing and fixing anodised M.S. Tower bolts (Barrel type) with necessary screws etc.complete in all respect and as per direction of Engineer-in-charge..
Providing and fixing anodised M S Handle with necessary srews etc complete in all respect and as per direction of Engineer-in-Charge.
Applying a coat over new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt,and other foreign matter , sand papering and knotting ready mixed paint brushing wood primer pink complete in all respect and as per direction of Engineer-in-charge.
Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give even shade including cleaning the surface of dust and other foreign matter, sand preparing and stopping with enamel paint other than white complete in all respect and as per direction of Engineer-in-charge.
Sunny Kapoor
Bharat Engg and Suppliers
Naik Electrical Works
KUSHAL SINGH RAGHAV
Saurabh Vasudeva
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .