Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 37 B SAHEB KRUPA SOC JIVAN CHETAN SCHOOL SAMA ROAD VADODARA GUJARAT PIN 390 008 | VADODARA | GUJARAT | 390008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.6 L+₹3.7 L (10.6%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹40.6 L+₹5.7 L (16.2%)Rejected-AOC 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹41.1 L+₹6.1 L (17.6%)Rejected-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹41.6 L+₹6.7 L (19.1%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹77,880
Closing Date
2 Dec 2023, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2023_MES_626835_1
8761
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARODA
As per tender documents
5 documents required · 5 mandatory
₹500
GE ARMY BARODA
₹77,880
Yes
17 Jan 2024
4 Nov 2023
7 Dec 2023
4 Nov 2023
2 Dec 2023
25 Nov 2023
5 Nov 2023 - 25 Nov 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each . Note - Quoted rate shall be deemed to be include for cutting holes/necessary demolition of PCC block/brick work etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
S & F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators & partition with one or more rebates including joining cleat for fixing etc. complete all as specified.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors of any type including all necessary fittings, windows, ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per the directions of Engineer-in-charge.
M & L for 5.5mm thick sheet glass, frosted and glazing with rubber beading or with glazing clips, exc 0.5 Sqm in each pane all as specified and directed.
M & L for 12mm thk prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screws to aluminium frame work all as specified and directed.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete.
S&F Framed work as in grill/grating, of angle or other section with gusset plates, rails, braces, etc., complete for tank cage, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe-290 (Gde E 165) complete all as specifed and directed.
M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Polishing of old existing Kota stone flooring i.e, cutting , grinding, joints pigment filling and polishing to get mirror finish all as specified and directed.
Taking down cement plaster on brick or stone walls /ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete
M & L for rendering 5mm thick on brick wall surface or concrete surfaces of ceiling in cement mortar 1:3, finished even and smooth (without using extra cement)
M&L for preparing new plastered surfaces of ceiling and applying three coats of white wash.
M & L for complete removal of existing internal treatment completely by scrapping and or rubbing of walls/ceilings of roof projection and chajjas etc. and applying two coats of plastic emulsion paint acrylic finish over a coat of alkali resistant primer and over a coat of 1.5mm thick wall care putty all as specified and as directed.
Material & Labour for complete removal of existing treatment of wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling etc. all as specified and directed.
M&L for Brickwork with sub class ‘B’ old size bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6
M & L for 10 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and surface finished even and smooth without using extra cement all as directed.
M & L for new plastered surfaces of wall and applying two coats of plastic emulsion paint acrylic finish (internal surface) over a coat of alkali resistant primer and over a coat of 1.5mm thick wall care putty all as specified and as directed.
M&L for 15 mm thick Rendering in two layer on fair faces of brick work or concrete surfaces of wall ,5 mm thick in CM 1:4 mixed with WPC as per manufacturer's instructions finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured separately) all as specified and as directed.
Material & Labour for preparation of new wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
Complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for 50 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggregate mixed with WPC as per manufacturer's instructions of cement finished surface even and fair without using extra cement for laying of WPT all as specified and directed. (WPC will be measured and paid separately).
M&L 10mm thick rendering on roof in CM 1:3 mixed with WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over PCC surface for laying APP membrane on roof (WPC will be measured and paid separately).
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying atactic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimuum 3 Kg/Sqm, 3 mm thick (minimum) with minimum 75 mm side overlaps and minium 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge
M & L for brushing with neat cement slurry @ 3Kg/Sqm
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.25 Ltrs/Sqm, and laying self adhesive water proofing membrane 1.5 mm thick with minimum 75 mm side overlaps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over membrane complete all as specified and directed by Engr-In-Charge
M&L for Treatment of roof cracks in existing roof surface by cutting out portion along the cracks with mechanical equipment into 'V' shape, cleaning the cut out portion with compressed air to remove all foreign materials like dust, dirt, aggregates etc., apply the crack seal compound over existing cracks of roof as per manufacturer instructions or all as specified entire satisfication of GE/Engineer-in-Charge. Make: FOSROC/Dr Fixit/Pidilite or equivalent
Dismantling wall and ceiling boards or insulation board any thickness including cover fillets complete.
Providing and fixing false ceiling with 8 mm thick single side prelam PVC sheet fixed with screw to GI grid 605x605 mm Gl frame work for false ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. [Note:Colour and pattern of PVC Sheet shall be as approved by Engr-in-Charge/GE.]
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc.15 cm thickness (below or above ground level) and removing from site all as specified and directed.
M&L for 75mm thick plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base complete, all as specified & directed.
M & L for 75 mm thick PCC 1:3:6 mix type C2 using 40mm graded stone aggregate as in plinth protection and paving finishing concrete surface even and smooth without using extra cement. (Note: Plinth protection shall be laid in bays with suitable filling material in between).
Supply only liquid water proofing compound all as specified and directed.
M&L for18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in floor, steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
M&L for Glazed/decorative/textured ceramic coloured walls tiles in vertical surfaces 450X 300X 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering for backing coat on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles.
M&L for PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site complete including necessary PVC frame work of 10 mm thick PVC solid strips to support the wall lining all as specified and as directed as per colour of wooden texture and pattern approved by Engr-in-Charge/GE.
Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 15 mm thick in cement morter1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as directed.
S & F 0.63mm thick Galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 all as specified.
S & F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as specified.
S&F 110 mm bore PVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, including bends etc. complete fixed to walls.
M&L for Anti TermiteTreatment of soil under existing floors using chloropyriphose 20%EC emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion (chloropyriphose 20%EC) per square metre of surface area complete all as specified and directed.
M&L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection,chajja,fins,facia, roof bands etc and making good with RCC (1:1½:3) type A0 (nominal mix) (using 12.5 mm graded stone aggregate) in RCC roof projection,chajja, fins,facia, roof bands etc and finished surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement) if required complete as directed by the Engr-in-Charge. (Reiforcement will be measured and paid saperately under respective item)
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing from site all as specified and directed.
M&L for RCC 1:2:4 type B-1 (Nominal mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like and chajjah including necessary form work all as directed
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
S&F in repairs 22 to 25 mm dia stainless steel curtain rod, fancy type/decorative type, fixed to walls complete all as directed.
S&F in repairs, stainless steel decorative finials (round type with mirror optic finish trade/standard pattern suitable for 22 to 25 mm dia decorative/fancy type curtain rods.
Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbed surface of wall, floors, etc complete all as directed by Eng-in-Charge.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC Conduit 20 mm dia and all accessories Concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., including necessary cutting chases etc all as specified and as directed for the following: -
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 6 Amp switch socket point on independent board
All as per item No 54 here-in-before but one 3 pin socket out let 6 Amps on same board with other switches
All as per item No.54 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated flexible copper conductor as in continious earth for one independent 6 pin 16 Amp socket.
S & Fswitch piano flush type SP one way 6 Amp.
S & F switch socket combination 2 in 1, 3 pin, 6 and 16 amp flush type universal.
M & L for switch Socket combination outlet 2 in 1 , 5 pin, 6 Amps flush type.
M & L for Socket outlet 2 in 1 , 3 pin, 6 Amps flush type.
S & F ceiling rose surface polycarbonate body three terminal complete all as specified and directed
Supply and fix in repair LED light fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Taking down existing fitting any type and Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down old existing fitting any type and Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.. Make-Havells / Phillips / Wipro
Supply and fix ceiling fans, complete with three blade, down rod, electronic regulator and accessories 230V, 1200mm sweep, with Squirrel cage induction motor incl taking down existing fan all as specified and directed by Engr-in-Charge. Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard.
Supply & fix for replacement of metal clad box with plug and socket 20 Amps with one MCB SPN of 20 Amps complete all as specified and directed
M & L for wiring for circuit /sub main wiring with 2 run of 4.0sqmm FRLS PVC insulated copper conductor, single core cable and 1 run of 4.0sqmm FRLS PVC insulated copper conductor, single core cable as earth wire in surface / recessed as required drawn in and including suitable size rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge including taking down old unserviceable/damaged Sub main wiring of any type and size including continuous earth wire, conduit/casing capping / Batten cutting chases etc,making good disturbed surfaces of walls/ceiling with CM 1:3 and matching surfaces with existing colour.[Note:- Two run of main wire and one run of earthwire alongwith cunduit shall be measured as one length.]
M & L for wiring for circuit /sub main wiring 2 run of 6.0sqmm FRLS PVC insulated copper conductor, single core cable and 1 run of 6.0sqmm FRLS PVC insulated copper conductor, single core cable as earth wire in surface / recessed as required drawing in and including rigid PVC medium grade cunduit concealed / on ceiling as per site required or directed by Engr-in-Charge. Including taking down old unserviceable/damaged Sub main wiring of any type and size including continious earth wire, conduit/casing capping / Batten cutting chases etc,making good disturbed surfaces of walls/ceiling with CM 1:3 and matching surfaces with existing colour. [Note:- Two run of main wire and one run of earthwire alongwith cunduit shall be measured as one length.]
S & F sheet metal enclosures (double door) for DBs where MCBs to be used triple pole and neutral 4 way 415 V with rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 12 way 240 V with 200 amps rated bus bar fixed on wall (flush/surface as ordered). Including taking down DBs/Main switches / Busbar box of any type and capacity and removing from site.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed
Supply and fixing 415V 10KA 'B' curve TPN 63 AMP miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning as directed
S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.
S & F for MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts
Taking down existing earthing and M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including necessary earth work and excavationall as specified or indicated including testing on completion
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes etc and getting out in soft/loose soil complete
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete
Returning filling in excavated approved soil including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil completed all as specified and directed
M & L for sand cushoning to cable with dry river sand and punning to provide required cover for UG cables complete
M & L brick protection cover to electric cable with sub class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 35 sq. mm 3.5 Core nominal cross section in service connections .
M & L for galvanized steel tubing light Grade of 50 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Badri Electricals
Chanda Construction Co.
Gayatri Associates
JAY DWARAKDHISH ENTERPRISE
Hirachand Sunderji and co
Harsh Infrastructure
AKANKSHA CONSTRUCTION
VINUBHAI P. CHANDRA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .