Mr. Hitendrakumar Arvindrai Surti
Tender for the Work of Erection & Maintenance of HT-LT lines , T/C& Underground Cable etc. at Karajgam, Pali & Kalai villages under ND Scheme & Various Scheme at within Jurisdiction of Sarigam Rural Subdivision under Vapi Ind. Division.
365632
VPID/TECH/TENDER/2678 Dtd. 13.11.2026
Open
Electrical and Maintenance Works
Works
Valsad
4 documents required · 4 mandatory
₹3,540
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹29,000
13 Nov 2026
13 Nov 2026
13 Nov 2026
21 Nov 2026
13 Nov 2026
180 days
(A) CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Sr No. Item Code Description UNIT Rate
9926000001 HT TAPPING FROM THE EXISTING POLE INCLUDING NO.
FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC.
1 COMPLETE AND PAINTING OF FABRICATED MATERIALS
AND NUMBERING COMPLETE WITH COST PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
9926000002 ERECTION OF PSC POLES OF 8METER 200 KG NO.
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS
ANTICLIMBING DEVICES, INSULATORS ETC.COMPLETE
2 AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
9926000003 ERECTION OF STEEL POLES OF 9 TO 11 METERS NO.
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD,
3 INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLE, FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SET AND EARTHING.
9926000004 ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY NO.
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV
OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS, TOP
FITTING CLAMPS,ANTICLIMBING DEVICES DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING
OF STEEL POLES, FABRICATED MATERIALS USED ON
4 THE POLES ANDNUMBERING WITH COSTOF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
9926000005 ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS NO.
200 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING
DEVICES DANGERBOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING. (WITHOUT AB SWITCH)
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000006 ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 NO.
METERS.STEEL POLE INCLUDING EXCAVATION OF PITS
&REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS,ANTI-CLIMBING DEVICES
DANGER BOARDS, INSULATORS ETC.COMPLETE
6 &PAINTING POLES,FABRICATED MATERIAL SUSED ON
THE POLES AND NUMBERING WITH COST OF PAINTSAS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET ANDEARTHING. (WITHOUT AB
9926000007 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH, HGFUSES OF 8 MTRS
KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH,FIXING OF CHANNELS
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING
DEVICES, DANGER BOARDS, INSULATORS,DO FUSES
ETC. COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING OF
ERECTION OF GUY SET AND EARTHING. (WITH AB
9926000008 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH,HG FUSES, 9 TO 11 METERS
STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, FIXING OF CHANNEL,
SUPPORTING ANGLES, CLAMPS, ANTICLIMBING
DEVICES , DANGER BOARDS, INSULATORS, ETC.
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES ANDNUMBERING
8 WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUTEXCLUDING ERECTION OF
GUY SET AND EARTHING. (WITH AB SWITCH)
9926000009 ERECTION OF DOUBLE POLE STRUCTURES WITH NO.
MOUNTING OFAB SWITCH,FUSES, TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS
9 CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS,CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
9926000010 ERECTION OF DOUBLE POLE STRUCTURE WITH NO.
MOUNTING OF AB SWITCH,HG FUSES TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO
METERS STEEL POLES INCLUDINGEXCAVATION
OF PITS & REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE, FIXINGOF
10 CHANNELS SUPPORTING ANGLES, BRACING, CROSS
ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC.
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTIONS OF GUY SETS AND EARTHING.
9926000011 ERECTION OF GUY SET INCLUDING EXCAVATION OF NO.
PITS & REFILLING OF EARTH AS PER STANDARD
SPECIFICATION WITH STAY CLAMPS, STAY WIRE,
11 ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY
INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000012 CONCRETING OF POLES, GUYS, ETC. INCLUDING COST CMT
12 OF CEMENT SAND METAL (1:2:4)AND WATER ETC. AS
PER STANDARD SPECIFICATION.
9926000013 ERECTION OF COIL TYPE EARTHING INCLUDING COST NO.
13 OF COAL,SALT ETC. BUT WITHOUT COST OF Gl WIRE AS
PER STANDARD SPECIFICATION(20kg salt+20kg coal)
9926000014 ERECTION OF Gl PIPE/CI PLATE TYPE EARTHING NO.
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE Gl WIRE AS PER
STANDARDSPECIFICATION. (20k solt+20k coal)
9926000015 ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH NO.
CLAMPS, BRASS NIPPLE, BRASS HOLDER
TECK WOODBUSH,REFLECTORS FUSE, WIRING ETC. AS
15 PER STANDARD SPECIFICATION BUT EXCLUDING COST
9926000016 STRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONECONDPER
16 CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING KM
FIXING OF INSULATORS BINDING JUMPERING ETC.
9926000017 STRINGING OF Gl WIRE 8 SWG INCLUDING BINDING DO
9926000018 PROVIDING SINGLE PHASE SERVICE CONNECTION NO.
WITH- PVC 4MM TWIN CORECABLE FROM TERMINAL
POLE TOMETERING POINT INCLUDING FIXING OFMETER
WITH METER EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT EXCLUDING COST OF
9926000019 PROVIDING THREE PHASE 4 WIRE SERVICE NO.
CONNECTION WITH PVC 4MM2/10MM2 FOUR CORE
CABLE FROM TERMINAL POLE TO METERING POINT
INCLUDING FIXING OF METER WITH METER EARTHING
COMPLETE WORK AS PER STANDARD SPECIFICATION
BUT EXCLUDING COST OF MATERIALS.
9926000020 ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD NO.
ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS PER
STANDARD SPECIFICATION OVER & ABOVE NORMAL
20 COST COVERED AGAINST EXCAVATION OF PIT UNDER
NORMAL SOIL FOR ERECTION OF POLE,GUY, DOUBLE
POLE STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL MTR
9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE NO.
24 9926000024 LT LINE TAPPING- THREE PHASE NO.
9926000025 LAYING OF OVER HEAD LT CABLE FOR ROAD NO.
25 CROSSING,HT LINE CROSSING AND TELEPHONE LINE
CROSSING ETC.(PER SPAN)
9926000026 ERECTION OF SINGLE POLE STRUCTURESWITH, HG NO.
FUSES,TRANSFORMERS,LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 8 METERS 200 KG PSC POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS,
26 ANTICLIMBING DEVICES DANGER BOARDS,CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000027 ERECTION OF SINGLÉ POLE STRUCTURES NO.
FUSES,TRANSFORMERS,LIGHTENING ARRESTOR,
DISTRIBUTION BOX. ON 9 to 11 METERS RSJ POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO
SITE, FIXING OF CHANNELS, SUPPORTING
27 ANGLES,BRACINGS CROSS ARMS CLAMPS,
ANTICLIMBING DEVICES DANGER BOARDS,CONDUCTOR
AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY
SETS AND EARTHING.
9926000028 ERECTION OF PSC POLES OF IO METER 270 KG NO.
INCLUDING EXCAVATION OF PIT AND REFILLING OF
EARTH, FIXING OF CROSS ARMS, TOP FIITING CLAMPS
ANTICLIMBING DEVICES, INSULATORS ETC. COMPLETE
AND PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
9926000029 ERECTION OF DOUBLE POLE STRUCTURE OF 10 METER NO.
270 KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING
DEVICES DANGERBOARDS,INSULATORS
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARDSPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS
ANDEARTHING. WITHOUT AB SWITCH
9926000030 STRINGING OF IOOMM2 ACSR/100MM2 AAAC ONE
CONDUCTOR FOR HT/ LT LINES INCLUDING FIXING OF COND
INSULATORS, BINDING JUMPERING ETC. PER
9926000031 STRINGING OF DOG CONDUCTOR FOR 11/22KV HT ONE
LINES INCLUDING FIXING OF INSULATORS, BINDING COND
JUMPERING ETC. PER
9926000032 ERECTION OF DOUBLE POLE STRUCTURES WITH NO.
MOUNTING OF AB SWITCH,HG FUSES, TRANSFORMERS,
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KG PSC POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS
32 ARMS CLAMPS, ANTI-CLIMBING DEVICES,DANGER
BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING.
9926000033 DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING No.
OF FABRICATION AT STORE &STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
9926000034 DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING No.
OF FABRICATION AT STORE & STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
9926000035 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR No.
PSC POLE) (WITH TRANSFORMER) WITH CREDITING OF
35 FABRICATION & TRANSFORMER AT STORE & STACKING
OF POLE SAFELY ON ROADSIDE OR CREDITING TO
DEPARTMENTAL STORE
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000036 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR No.
PSC POLE) (WITHOUT TRANSFORMER) WITH CREDITING
36 OF FABRICATION AT STORE & STACKING OFPOLE
SAFELY ON ROAD SIDE ORCREDITING TO
DEPARTMENTAL STORE
9926000037 STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM KM
INCLUDING FIITING OF ALL ACESSORIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING
OF MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
37 PIERCE-ING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
9926000038 STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ KM
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE
INSULATOR ETC. FOR FIXING OF MESSENGER WIRE
AND TO PROVIDE SERVICE CONNECTION ON AERIAL
38 BUNCH CABLE BY INSULATED PIERCE-ING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
9926000039 STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGNSUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
39 SHACKLEPOINT,JUMPERS ETC. AS REQUIRED
&DIRECTED BY ENGINEER IN CHARGE
9926000040 STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM KM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGNSUSPENSION / TENSION CLAMP, FIXING
OFCROSS ARM, BINDING TO PIN
40 INSULATOR,PREPARING SHACKLEPOINT,JUMPERS ETC.
AS REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
9926000041 STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ KM
35 SQ MM INCLUDING FITTING OF ALL ACESSORIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP,
FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY
41 INSULATED PIERCE-ING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND Nos
42 CREDITING THE OLD MATERIAL TO STORE
9926000043 DISMENTALING TRANSFORMER CENTER ON IO Nos
MTR,270KG PSC POLE WITHOUT TRANSFORMER WITH
CREDITING OF FABRICATION AT STORE AND STACKING
43 OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000044 DISMENTALING OF TRANSFORMERCENTER Nos
ON IOMTR,270KG PSC POLE(WITH TRANSFORMER)
WITH CREDITING OF FABRICATION AT STORE AND
44 STACKINGOF POLE SAFELY ON ROAD SIDE
ORCREDITING TO DEPARTMENTAL STORE
9926000045 DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ KM
MM AND CREDITING FITTINGOF ALL ACESSARIES AND
45 FABRICATION TO DEPARTMENTAL STORE
9926000046 DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ KM
MM AND CREDITING FITTINGOF ALL ACESSARIES AND
46 FABRICATION TO DEPARTMENTAL STORE
9926000047 DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ KM
47 MM AND CREDITING FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
9926000048 DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ KM
MM+1*35 SQ MM AND CREDITING FITTING OF ALL
48 ACESSARIES TO DEPARTMENTAL STORE.
9926000049 DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ KM
MM+ 1*35 SQ MM AND CREDITING FITTING OF ALL
49 ACESSARIES TO DEPARTMENTAL STORE.
9926000050 RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT ONE
DOG CONDUCTOR) FOR 11/22KV & LT LINES COND
50 INCLUDING FIXING OF INSULATORS, BINDING PER KM
9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT ONE
LINES INCLUDING , BINDING JUMPERING ETC. COND
9926000052 LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR NO.
52 METER. (METER WILL BE PROVIDED BY DGVCL
9926000053 LABOUR CHARGE FOR THE REPLACEMENT OF DTR NO.
METER AND OLD METER SHOULD BE CREDITED TO SDN
53 STORE. (METERWILL BE PROVIDED BY DGVCL
9926000054 LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR PER
54 METER CONNECTION. (CT COILWILL BE PROVIDED BY CT
9926000055 LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR PER
DTR METER CONNECTION AND OLD CT SHOULD BE CT
55 CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED
9926000056 LABOUR CHARGE FOR FIXING OF MMB FORDTR METER NO.
56 (MMB WILL BE PROVIDED BY DGVCL
9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR NO.
57 METER BOX. (METER WILL BEPROVIDED BY
9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE NO.
58 COPPER CABLE 3.5 METER (CABLETO BE PROVIDED BY
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000059 LABOUR CHARGE PER
FORPROVIDING/RECONNECTION OF TERMIN
59 TERMINALCONNECTION WITH PROPER SIZE OF LUGS. ATION
LUGS COST IS BORNE BY AGENCY
9926000060 LABOUR CHARGE FOR THE SPOT READINGOF DTR PER
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DTR
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN
PROFORMA REPORT SHOULD BE SUBMITTEDTO SDN
ONLY IF ALLPARAMETER OF VOLTAGE, CURRENT &
60 LOAD AS SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
9926000061 LABOUR CHARGE FOR THE SPOT READINGOF DTR PER
METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DTR
DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN
PROFORMA REPORT SHOULD BE SUBMITTED TO SDN
61 OFFICE. (DULY FILL PER-FORMA IN FAULT CONDITION
IN WHICH READINGPARAMETER IS NOT SHOWN IN
9926000062 INSTALLATION OF DTR METER INCLUDING METER BOX, NO.
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND
CORE ARMOURED COPPER CABLE (3.5METER),
62 TERMINATION IN METER & COIL BOX,CT/PT COIL
WILLBE PROVIDED BY DGVCL
9926000063 INSTALLATION OF DTR METER INCLUDING METER BOX, NO.
TERMINATION IN METER & COIL ETC. (WITHOUT
CORE COPPERCABLE) (METER,METER BOX,CT/PT
COILWILL BE PROVIDED BY DGVCL
9926000064 Binding of messanger Conductorat with a distance not NO
more than 0.75 mtr with 6 turns minimum on XLPE
64 Cable with single strand binding wire (including cost of
9926000086 Supply and Installation of 11/22 kV Distribution PER SET
Transformers HT Terminal protector (UV Resistance)
65 with using 95/120/150 sq.mm long barrel aluminum
lug. (1Set = 3 Nos i.e. on R, Y, B)
9926000087 Supply & Installation of HT EPR Tap on 11/22 kV PER SET
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to
transformer) after removal of semi conductor by HT
66 ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
9926000088 Supply, Installation, Testing and Commissioning of NO
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
67 Type, Earth Electrodes for HT Feeder Pole Having
mm Electrode Length as per the Tender Specifications
and Drawing. (All Materials Will Be Supplied By Agency)
9926000089 Supply, Installation, Testing and Commissioning of NO
Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic)
Type, Earth Electrodes for HT Feeder Pole Having
68 mm Electrode Length as per the Tender Specifications
And Drawing. (All Materials Will Be Supplied By Agency)
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
9926000090 Supply and Installation of 25 X 3 mm GI Strip having Meter
hot dip- galvanized-zinc coating of 80-100 microns
without any joints or welding. Both the end of the GI
strip should be connected with GI nut bolts and
required fabrication work for giving separate earthing
connections to(1) Neutral of the transformer(2) MS
structures of the transformer center (Approximately
meter GI strip per transformer centre- as per
requirement and instruction of Engineer in- charge) (All
Materials will be supplied by Agency)
9926000092 Supply and Installation of uPVC standard make Pipe of Meter
1.25" diameter for covering GI strip with UV protected
Cable Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip
70 covering per transformer centre -as per requirement
and instruction of Engineer in-charge.
9926000093 Supply & fixing of upto 33 kV Conducotr sleev for per TC
Busbar to Drop out Fuse and Drop out fuse to
Transformer H.T. including Busbar (12 mm sleev) as
71 per technical specification. (All Materials will be
supplied by Agency)
9926000100 Supply & fixing of upto 33 kV Conducotr sleev for per TC
Busbar to Drop out Fuse and Drop out fuse to
Transformer H.T. without Busbar (15 mm sleev) as per
72 technical specification. (All Materials will be supplied by
9926000094 Supply & fixing of upto 33 kV Conducotr sleev for per TC
Busbar to Drop out Fuse and Drop out fuse to
Transformer H.T. including Busbar(15 mm sleev) as per
73 technical specification. (All Materials will be supplied by
9926000101 Supply & fixing of upto 33 kV Conducotr sleev for per TC
Busbar to Drop out Fuse and Drop out fuse to
Transformer H.T. without Busbar(15 mm sleev) as per
74 technical specification. (All Materials will be supplied by
9926000095 Supply & fixing of Disc type Red Color FRP(Non- NO
flammable) material with Weather resistant, Non-
conductive bird guard OD=300 MM, ID=33 MM, Width
75 =1.25 MM, one side cut from ID to OD. (All Materials
will be supplied by Agency)
9926000096 Providing and fixing of LT Terminal protectors i.e. Re- NO
useable boot (LT Side 1.1 kV) including LT (1.1 kV)
76 insulating taps. All live part at LT side shall be covered
with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per tc
9926000099 Labour charge for fitting Nylon Net (All fabricated Per tc
77.3 material for fitting nylon net shall be provided by
(B)Labour Charges for Maintenance Work
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
1 9924000001 Cutting of Tree branches surrounding HT/LT line per Tree
Replacement of old jumpers & providing new double
2 9924000002 jumpers with 8" binding & capsuling with PVC pipe etc. No
3 9924000005 Support pole for stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole
5 9924000007 in coastal area with cleaninGg . No.
6 9924000008 Pin binding of conductor LT shackle insulator No.
7 9924000009 Replacement of one/bothinsulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Re-fixing of V cross Arm No.
10 9924000012 Re placement of V cross Arm No.
11 9924000013 Re-fixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting& jumpering (ONE
Numberings of pole with paint by preparing back
ground of one colour and
15 9924000017 have lettering(height 3" * width0.5" using stencil No.
16 9924000018 Fixing of MMB(IPH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (Iph.) meter forUrban area No.
19 9924000021 Replacement of (Iph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter size
20 9924000022 height40mm* width 8mm No.
painting consumer no. on MMB (Rural) (with letter size
21 9924000023 height 40mm* width 8mm No.
22 9924000024 Replacement of deteriorated Single hase Service line No.
Fixing of new dist. Box with complete wiring includin
23 9924000025 clamps, nut bolts etc. No.
Repairing of guarding involving reshaping of bearer
24 9924000026 wire cross lacing binding etc. R Mtr.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
26 9924000028 mounted transformer double pole structure with paint No.
Painting of steel fabricated material of RSJ single pole
painting of steel fabricated material of PSC Single pole
28 9924000030 (HT line) with paint No.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
painting of steel fabricated material of PSC DO DP
29 9924000031 double pole with paint No.
painting of steel fabricated material of PSC double pole
30 9924000032 at pole mounted transformer with paint No.
31 9924000033 Providing line separator single phase No.
32 9924000034 Providing line separator three phase No.
Replacement / Providing of stay insulator along with
33 9924000035 adjustment No.
of tension in stay wire
Replacement of deteriorated /providing LT dist. Box
34 9924000036 with new up to 100KVA capacity & crediting it to store. No.
Replacement of deteriorated /providing LT dist. Box
35 9924000037 with new above 100KVA capacity & crediting it to No.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including
38 9924000040 dismantling & restringing etc. location
replacement of 11KV Pin insulator with providin new
39 9924000041 double in binding No.
replacement of 22KV Pin insulator by new 11 kv pin
40 9924000042 insulator with spares & providin new double in binding No.
Providing 11 kv double disc insulators with binding &
Replacement of existing conductor (all size) with new
42 9924000045 double in binding Cond/KM
43 9924000046 Plumbing of psc Pole with straightening at pin point No.
Plumbing of psc Pole with straightening at tension
Plumbing of tilted DP structure (PSC/RSJ/STP) with
45 9924000048 refilling of stone Murrum etc. No.
Providing new 11 kv AB [GO switch with fabrication and
46 9924000049 insulated colour code jumper binding lugs etc. Set
Replacement of old 11 kv AB /GO switch with providing
47 9924000051 new insulated jumper, binding, lugs etc. Set
Providing cage type loop guard in vertical LT line with
48 9924000052 using PVC reel insulators etc. per pole
Labour charges for replacement /providing of MMB &
49 9924000053 service with all No.
accessories for three phase connection
Labour charges for replacement /providing of MMB &
50 9924000054 service with all accessories for connection No.
Dismantling of existing Dist. X'mer center (RSJ/STP
POLE) 25/63/100/200 KVA
51 9924000055 with all fabrication & crediting the old material to No.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
52 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase (payment after
53 9924000057 receipt of R/C charges) No.
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase (payment after
55 9924000059 receipt of R/C chagr es No.
Dismantling & removing of service line from pole &
56 9924000060 crediting to S/dn (1 phase) No.
Dismantling & removing of service line from pole &
57 9924000061 crediting to S/dn (3h phase ) No.
Reconnection of service line complete with PVC cable(1
Reconnection of service line complete with PVC cable(3
Providing spiral type earthing by connecting earth
terminal with earth terminal of meter box with G.I.
SWG no 8 up to 1.5meters (total weight approximately
2.2kg-20 meter in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia (1.5mtr length) to
cover exposed part of G.I. wire , providing and fixing of
single core 1.5 sq mm single strand copper insulated
cable with cable nail clip to be connected with
60 9924000064 connector to G.I. wire at consumer end as per drawing No.
DGVCL cons. earth. Earth resistance should be less
than 2 ohms(All materials supplied by contractor .
Providing and fixing of single core 1.5 sq mm single
strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of G.I.
no 8 is to be connected by connector with copper cable
of which other end shall be connected to the earth
terminal of meter box. This item shall be used in
61 9924000070 location where there is more distance between earth per meter
terminal and earthing terminal of meter. All materials
supplied by contractor).
(C) Fabrication from Raw Materials Of Mild Steel
Fabrication of Anchor Rod from 16 SQ.mm MS Round
bar & 65 mm x 65 mm x 6 mm M.S. angle as per
62 9910000049 approved drawing and requirement of the company. No.
Fabrication of Anchor Rod from 16 SQ.mm MS Round
bar & 50 mm x 50 mm x 6 mm M.S. angle as per
63 9910000050 approved drawing and requirement of the company. No.
Fabrication of Eye Bolt from 16 SQ.mm MS Round bar
with supplying of 2 (two) nuts of suitable size as per
64 9910000015 approved drawing and requirement of the company. No.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Fabrication of Turn Buckle from 16 SQ.mm MS Round
bar & 65 mm x 65 mm x 6 mm mm M.S. angle as per
65 9910000028 approved drawing and requirement of the company. No.
Fabrication of Turn Buckle from 16 SQ.mm MS Round
bar & 50 mm x 50 mm x 6 mm M.S. angle as per
66 9910000016 approved drawing and requirement of the company. No.
Fabrication of 11' (feet) long Top/Bottom/D.O. angle
from 65 mm x 65 mm x 6 mm M.S. angle as per
67 9910000030 approved drawing and requirement of the company. No.
Fabrication of 9' (feet) long Top/Bottom/D.O. angle
from 65 mm x 65 mm x 6 mm M.S. angle as per
68 9910000031 approved drawing and requirement of the company. No.
Fabrication of 4'6" (feet) long Tapping / bracing angle
from 65 mm x 65 mm x 6 M.S. angle as per approved
69 9910000003 drawing and requirement of the company. No.
Fabrication of 2'3" (feet) long bracing/ support angle
from 65 mm x 65 mm x 6mm M.S. angle as per
70 9910000039 approved drawing and requirement of the company. No.
Fabrication of 11KV HT 'V' Cross Arm from 65 mm x
71 9910000021 mm x 6 mm M.S. angle as per approved drawing and No.
requirement of the company.
Fabrication of 11KV HT Top fitting from 65 mm x
mm x 6 mm M.S. angle and 50mm x 6 mm M.S. flat
72 9910000022 as per approved drawing and requirement of the No.
Fabrication of 22KV HT Top fitting from 65 mm x
mm x 6 mm M.S. angle and 50mm x 6 mm M.S. flat
73 9910000055 as per approved drawing and requirement of the No.
Fabrication of 22KV HT 'V' Cross Arm from 65 mm x
74 9910000037 mm x 6 mm M.S. angle as per approved drawing and No.
requirement of the company.
Fabrication of Guy Clamp pair suitable for PSC pole
from 50mm x 6 mm M.S. flat as per approved
75 9910000041 drawing and requirement of the company. PAIR
Fabrication of 'U' Clamp from 50mm x 6 mm M.S. flat
76 9910000024 as per approved drawing and requirement of the No.
Fabrication of 'C' clamp suitable for PSC pole from
77 9910000043 50mm x 6 mm M.S. flat as per approved drawing and No.
requirement of the company.
Fabrication of ‘C’ clamp suitable for RSJ GIRDER pole
from 50mm x 6 mm M.S. flat as per approved drawing
78 9910000044 and requirement of the company. No.
Fabrication of Three hole patti from 50mm x 6 mm
79 9910000056 M.S. flat as per approved drawing and requirement of No.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Fabrication of 11' (feet) long Top/Bottom channel from
100 mm x 50 mm x 5 mm M.S. channel as per
80 9910000061 approved drawing and requirement of the company. No.
Fabrication of 9' (feet) long Top/Bottom channel from
100 mm x 50 mm x 5 mm M.S. channel as per
81 9910000060 approved drawing and requirement of the company. No.
Fabrication of 11'(feet) long angle bracing from 50 mm
82 9910000035 x 50 mm x 6 mm M.S. angle as per approved drawing No.
and requirement of the company.
Fabrication of 9'(feet) long angle bracing from 50 mm x
83 9910000034 50 mm x 6 mm M.S. angle as per approved drawing No.
and requirement of the company.
Fabrication of 11' (feet) long channel welded from
84 9910000062 assorted length of scrap channel as per approved and No.
requirement of the company
Fabrication of 9' (feet) long channel welded from
85 9910000063 assorted length of scrap channel as per approved and No.
requirement of the company
Fabrication of Guy Clamp pair suitable for 10 mtr PSC
pole from 50mm x 6 mm M.S. flat as per approved
86 9910000072 drawing and requirement of the company. PAIR
Fabrication of Guy Clamp pair suitable for 9/11mtr RSJ
GIRDER pole from 50mm x 6 mm M.S. flat as per
87 9910000073 approved drawing and requirement of the company. PAIR
Fabrication of 5' (feet) long Tapping angle from 65 mm
88 9910000066 x 65 mm x 6 mm M.S. angle as per approved drawing No.
and requirement of the company.
Fabrication of H.T. Ext'n suitable for 22KV system from
89 9910000067 65 x 65 x 6 mm M.S. angle as per approved drawing No.
and requirement of the company.
Fabrication of H.T. Ext'n suitable for 11KV system from
90 9910000068 65 x 65 x 6 mm M.S. angle as per approved drawing No.
and requirement of the company.
Fabrication of 750 mm long Channel for HT AB
conductor from 100mm x 50mm x 5mm M.S. Channel
91 9910000069 as per approved drawing and requirement of the No.
Fabrication of 22KV HT "V" Cross Arm from 100mm x
50mm x 5mm M.S. Channel as per approved drawing
92 9910000070 and requirement of the company. No.
(D) REPLACEMENT OF BARE CONDUCTOR BY HT / LT AERIAL BUNCH CONDUCTOR
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
1 9924000065 service connection on Aerial Bunch Cable by insulated KM
pierceing connectors through service connection box
complete as required & directed by Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of
cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of
existing bare conductor and crediting in to store &
dismentaling of service line from LT bare conductor
2 9924000066 and to provide service connection on Aerial Bunch KM
Cable by insulated pierceing connectors through
service connection box complete as required &
directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding
to pin insulator,preparing shackle point,jumpers etc.
and inclusive of dismantling charge of existing bare
3 9924000067 conductor and crediting in to store complete as KM
required & directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding
to pin insulator,preparing shackle point,jumpers etc.
and inclusive of dismantling charge of existing bare
4 99240000658 conductor and crediting in to store complete as KM
required & directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+
SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
5 9924000069 service connection on Aerial Bunch Cable by insulated KM
pierceing connectors through service connection box
complete as required & directed by Engineer in Charge.
(E)LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT
Sr. No. Item Code No. Unit Rate
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Labour charge for excavation of cable trench of 400mm
width x 1200mm depth, in any type of soil for laying of
cable of size up to 240 mm2 (For additional cable
1 9925000001 mm additional width shall be considered i.e. half trench Meter
length is to be considered
Labour charge for excavation of cable trench of 600mm
width x 1200mm depth, in any type of soil for laying of
cable of size up to 240 mm2 (For additional cable
2 9925000002 mm additional width shall be considered i.e. half trench Meter
length is to be considered
Labour charge for excavation of cable trench of 400mm
width x 1500mm depth, in any type of soil for laying of
cable of size up to 240 mm2 (For additional cable
3 9925000003 mm additional width shall be considered i.e. half trench Meter
leng th is to be considered
Labour charge for laying of 11kV / 22 kV XLPE Cable of
size up to 240 mm2 & preparation of sand layer
100mm thick, in the cable trench & covering the cable
with 150 mm dia (Outer), thickness 25 mm, 1.0 meter
long RCC half round muffs and providing and fixing of
4inch width yellow colour polyethylene tape with
printing"CAUTION ELECTRIC CABLE BELOW' at 0.75 m
depth from ground surface after laying cable in trench.
This will provide indication that electric cable is
passing underground so as to protect cable from
mechanical injuries, refilling the same, as per
Instruction of E gineer in Charge (EIC) .
Labour charge for horizontal drilling using Auger
machine without damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm 0.D. 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size
up to 240 mm2 in HDPE pipe, as per Site Condition
(excluding cost of pipe). The detail map obtained from
HDD machine and excel sheet hard and soft copy)
indicating the respective depth and distance from
adjacent landmark for each segment for HDD is must
require to be submitted. HDD to be carried out at depth
1.5 mtrs to 2.0 mtrs as per site conditions and as er
instruction of EIC.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Labour charge for horizontal drilling manually without
damage to surface road at max 2.0 mtrs depth &
putting of 6.11 kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2
size, as per Site Condition (excluding cost of pipe). The
detail map and excel sheet (hard and soft copy)
indicating the respective depth and distance from
adjacent landmark for each segment of cable to be
submitted. Drilling to be carried out at depth Minimum
1.2 mtrs to 2.0 mtrs as per site conditions as per
instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to IS
7 9925000007 4984 and BIS certification for laying of underground Meter
11KV/ 22KV XLPE cable up to 240 mm 2 size.
Labour work for RCC concreting on disputed location
and repairing of damage portion of road crossing for
8 9925000008 the work carried out for roads crossing as well as CMT
concreting & muffing of poles including all materials
Providing & fixing concrete stone route marker of
mm width x 150 mm thick x 650 mm height embedded
in earth at least 300 mm below & 350 mm above
ground level respectively at distance approx.
meters along the length of cable. The RCC concreting
(1:2:4)(all necessary materials will be in bidder's
scope) of route marker is to be carried out 300 mm
width x 150 mm thick x 300 mm below ground level as
per instruction of EIC. The route marker should be with
name of company with approved yellow colour-DGVCL.
The distance from marker to cable and cable depth
with feeder name etc., marked with arrow sign is to be
painted on it. The route marker is to be fixed at
location near to any fixed permanent location (not
necessary to fix exact on top of cable) as per
instruction of EIC.
Erection of D.P. (double pole) structure using 9 /
Mtr. RSJ pole with cable connection arrangement along
with fitting of necessary fabrication for 11KV cable
including excavation of pit & refilling of earth as per
10 9925000010 instruction of EIC. (Exclusive of concreting & muffing of No
Erection of Single pole structure using 9 / 11 Mtr RSJ
pole with cable connection arrangement along with
fitting of necessary fabrication for 11KV/22 KV cable
11 9925000011 including excavation of pit & refilling of earth as per No
instruction of EIC. (Exclusive of concreting & muffing of
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Erection of D.P. (double pole) structure using 8.0 Mtr.
PSC pole with cable connection arrangement along
with fitting of necessary fabrication for 11KV cable
including excavation of pit & refilling of earth as per
12 9925000012 instruction of EIC. (Exclusive of concreting & muffing of No
Erection of Single pole structure using 8.0 Mtr PSC pole
with cable connection arrangement along with fitting of
necessary fabrication for 11KV/22 KV cable including
13 9925000013 excavation of pit & refilling of earth as per instruction No.
of EIC. (Exclusive of concreting& muffing of poles
Labour charge for erecting of 11kV / 22 kV XLPE cable
of size up to 240 mm 2 on DP Structure with fixing of
02 Nos polymer cleats on top and middle part. Polymer
14 9925000014 cleats, nut bolts etc. fixing material to be provided by Meter
Providing & fixing of 6.11kg/cm2 , class4,Green color,
110mm O.D. 8.5mm thickness H.D.P.E. pipe confirms to
IS 4984 and BIS certification on the erected DP
structure for the mechanical protection of cable by
inserting the cable inside HDPE pipe. The HDPE pipe
shall be erected in such a way that 300mm shall be
below the ground level and the rest 2700 mm shall be
15 9925000015 supported on the DP Structure with 01 No Polymer perJob
cleat. All materials including polymer cleat and Nut bolt
to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm
dia class-B GI pipe with pit to be filled with salt & coke
and construction of chamber as per DGVCL Drg. No. dg
/100 for DP and cable. The earthing pit should be joined
16 9925000016 with cable by G.I. strip of size 1" width & 2 mm thick. No
All material GI pipe, Coke Salt etc will be supplied by
Supply & fixing of heat shrink type end terminations
(outdoor) for up to 11kV 3C x 185 mm2 size XLPE cable
17 9925000017 as per DGVCL technical s ecification No
Supply & fixing of heat & shrinkable end terminations
(outdoor) for up to 22 kV 3C x 185 mm 2 size XLPE
18 9925000018 cable ( as per DGVCL technical specification) No
Supply & fixing of heat shrinkable type end
terminations (indoor) for up to 11kV 3C x 185 mm
19 9925000019 size XLPE cable as per DGVCL technical specification No
Supply & fixing of heat & shrinkable end terminations
(indoor) for up to 22 kV 3C x 185 mm 2 size XLPE cable
20 9925000020 as per DGVCL technical specification No
Supply & fixing of heat shrinkable straight through joint
21 9925000021 for up to 11kV 3C x 185 mm 2 size XLPE cables as per No
DGVCL technical specification.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Supply & fixing of heat shrinkable straight through joint
type for up to 22kV 3C x 185 mm 2 size XLPE cable as
22 9925000022 per DGVCL technical specification No
Labour charge for excavation of 2100mm long x
1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as
per instruction of engineer-in-charge & covering the
23 9925000023 cable with 150 mm dia (Outer), thickness 25 mm, 1.0 No
meter long RCC half round muffs & refilling same as per
instruction of EIC .
Providing and fixing of insulating bus bar, made from
11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat shrinkable
antitracking core insulating tubing (1.1KV), on both end
terminal using Aluminium long barrel heavy duty up to
240 sq mm lugs, Aluminium bus connector. Taping with
PGclamp for bus conductor as per drawing and as per
instruction of EIC. The Allurninium lugs and PG clamp
24 9925000024 shall be covered with 11KV/22KV HT insulating tapes. No
(11KV/22KV XLPE cable will be in scope of DGVCL while
all other materials will be in bidder's scope.
Testing of cable at various points and commissioning
the feeder as per instruction of engineer-in-charge.Test
25 9925000025 result shall be submitted by contractor with bill. No
Preparation and submission of 6 (six) copies, of
complete layout drawings with GIS mapping as per
26 9925000026 actual cable routing showing road crossing, HDPE pipe Set
sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point
Made out of 2 mm aluminium sheet size 750x300 mm
(2.5 x 1 ft) rectangle, as per design, pretreated with
phosphate process and acid etching coated with one
coat of epoxy primer and two coats of best quality
paints, reflectorized with Hi Intensity retro — reflective
sheeting as per the latest and frame fabricated from
suitable size iron angle. The Sign Board is to be fixed
on the base prepared from channel and bracing angles
which is grouted by means of cement concreting of
1:2:4 for size of 300 mm dia x 800 mm height (500 mm
to be grouted in ground). The details to be displayed on
sign board will be given by InchargeEngineer. (a) Hi
intensity Micro prismatic Grade
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Providing and fixing of Sign Board (Danger Board) on
Distribution Transformer Centers Made out of 2mm
aluminium sheet size 300x300mm (1X1 ft) as per
design, pre treated with phosphate process and acid
etching coated with one coat of epoxy primer and two
coats of best quality paints, reflectorized with Hi-
Intensity retroreflective sheeting as per the latest and
frame fabricated from suitable size iron angle. The Sign
28 9925000028 Board (Danger Board is to be fixed at the location as No
per instruction of In-charge Engineer. (a) Hi intensity
Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L)
x 75 mm (W) from 3 mm aluminium sheet along with
1.0 mm dia aluminium binding wire for fixing of
aluminium tag near end termination joint at DP
structure for identifying the cable. The details of feeder
29 9925000029 i.e. 11 / 22 KV with feeder name should be punched on No
the tag by letter punch of size 16 mm as per instruction
of In-charge Engineer.
Supply & fixing of heat shrink type end terminations
(outdoor) for 11kV 3C x 240 mm2 size XLPE cable as
30 9925000030 per DGVCL technical specification. Nos
Supply & fixing of heat & shrinkable end terminations
31 9925000031 (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as Nos
per DGVCL technical specification
Supply & fixing of heat shrink type end terminations
32 9925000032 (indoor) for 11kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations
33 9925000033 (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint
34 9925000034 for 11kV 3C x 240 mm2 size XLPE cables as per DGVCL Nos
technical s ecification.
Supply & fixing of heat shrinkable straight through joint
35 9925000035 type for 22kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical s ecification
Installation, Testing and commissioning of 11 KV,630 A
SCADA Compatible, RRL type3 Way RMU including Two
numbers of earthings as per Drawing (material is in
36 9925000038 bidder's scope) and as per DGVCL Technical Nos
Installation, Testing and commissioning of 11 KV,630 A
SCADA Compatible, RRLL type4 Way RMU including
Two numbers of earthings as per Drawing (material is
37 9925000039 in bidder's scope) and as per DGVCL Technical Nos
Installation, Testing and commissioning of 22KV,630 A
SCADA Compatible, RRL type-3 Way, RMU including
Two numbers of earthings as per Drawing (material is
38 9925000040 in bidder's scope) and as per DGVCL Technical Nos
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Installation, Testing and commissioning of 22KV,630 A
SCADA Compatible, RRLL type-4 Way, RMU including
Two numbers of earthings as per Drawing (material is
39 9925000041 in bidder's scope) and as per DGVCL Technical Nos
Construction of plinth for 11KV, RRL type- 3 Way( i.e
Two numbers of Isolator & One number of Breaker)
Ring Main Unit as per DGVCL's technical specification
40 9925000042 mentioned in drawing no: Drg. 11kv-01. All required Nos
material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type4 Way (i.e
Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
41 9925000043 specification mentioned in drawing no:Drg. 11kv-02.AlI Nos
required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e
Two numbers of Isolator & One number of Breaker)
Ring Main Unit as per DGVCL's technical specification
42 9925000044 mentioned in drawing no: Drg. 22kv-01. All required Nos
material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type4 Way (i.e
Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
43 9925000045 specification mentioned in drawing no:Drg. 22kv-02.All Nos
required material will be supplied by contractor.
Modifications e.g. Providing and fixing ofTerminal
protectors i.e. Re-use able boot (HT Side 11/22KV, LT
Side 1.1KV) including 11/22 KV insulating taps and L.T.
(I.I KV) insulating taps ,Busbar, Tapping from Bus Bar
(11/22 KV XLPE cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of Transformer Center,
providing & Fixing of jumper and providing & fixing of
Heat Shrinkable Anti Tracking CoreInsulating Tubing
(Insulation Level 11/22 KV) in H.T. jumper , Clamping
arrangement of cable support frame on both side of
existing Over Head type Distribution Transformer to
utilize in Under Ground cable network as per drawing &
44 9925000046 as per instruction of Engineer incharge. All live parts Nos.
i.e. PGClamp, connections of D.O.fuses, HT bushings
etc . shall be covered with fixing of 11/22 KV HT
insulating tapes. ( 11/22 KV XLPE cable will be in scope
of DGVCL while all other materials will be in bidder's
Laying of any size of 11/ 22 KV XLPE /PILCCable in
readymade trench or in open space per cable
46 9925000060 Labour charges for lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm,
47 9925000064 meter long RCC half round pipe NO
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Letter No: DGVCLDVPI/0203/11/2026 Approved Date: 13-11-2026 14:21
Note :- All Rates are Excluding of GST.
1. DGVCL will provide key material like MS materials, ABC/Bare conductors, PSC/RSJ poles, Insulators, Fabricated
materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming to the
relevant ISI specification and as directed by Engineer in charge
3. Necessary electricity connection for fabrication items shall be provided by DGVCL on payment of required charge
for connection & electricity bill of the same shall be paid by the agency
4. All the rates are inclusive of PF and Exclusive of GST applicable time to time
5. Work to be carried out after issued of Sub work order by S/dn. Office not prior to that.
6. All steel material are to be painted as below:
(A) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated materials of
RSJ/PSC poles is must require.
(B) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles & Steel fabricated
materials of RSJ/PSC poles.
(C) Two coats of approved ISI mark Silver paint (i.e. triple mangoes or equivalent quality silver paint) is to be properly
painted on to the RSJ poles & Steel fabricated materials of RSJ/PSC poles.
7. Submission of Bill for Supply/Purchase of KIT Cable Usage, with bifurcation of Supply amount along with Labour.
8. Any material (XLPE / Aerial Bunch Cable, Joint Kit etc.) provided by contractor is approved by DGVCL make,
specification and submission of Invoice with purchase bill.
9. The rates are inclusive of dismantling charges of existing bare conductor and crediting in to store & dismantling of
service lines from LT bare conductor and to provide service connections on ABC by insulated pierce connectors
through service connection box.
10. The contractor has to collect all the required materials from DGVCL store as well as credit the dismantle material
to the DGVCL store at their cost.
11. Labor Wellfer Cess @1% shell be Deduction in Bill Amt.
EXECUTIVE ENGINEER (O&M);
DGVCL; VAPI IND DIV.
File No: DGVCLDVPI/TEN/e-file/4448/2026/3620/Account
Approved By: Executive Engineer,Technical,DGVCLDVPI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT-2678.pdf
Schedule-B.pdf
Erection.pdf
forwading.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .