Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹8,400
Closing Date
18 Feb 2022, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEEANDMM-5
EEEANDMM-5 NEAR KANHIYA NAGAR METRO STATION DELHI-35
Improvement of external and internal lighting at Idgah water emergency Re-invited
2022_DJB_216661_4
NIT NO. 19 (2021-2022)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMM-5
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹8,400
11 Mar 2022
12 Feb 2022
18 Feb 2022
12 Feb 2022
18 Feb 2022
12 Feb 2022
120 days
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required including all tools and tackles as per site requirement. Group C DSR 1.10.3
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as Required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR 1.14.2
Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.14.3
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pins 5/6- & 15/16-amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. DSR 1.56
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) DSR 1.27.4
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) DSR 1.27.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch DSR 1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet DSR 1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet. DSR 1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A switch. DSR 1.24.3
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.- Single pole -(DSR No. 2.10.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole. DSR 2.10.3
Installation, test fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including and commissioning of pre-wired, fluorescent connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required DSR 1.41
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as Required .12 way (4 + 36), Double door. DSR 2.5.3
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door. DSR 2.4.2
Earthling with Copper earth plate 600mmx600mmx3mm thick including accessories, and providing masonry enclosure with cover plate heaving locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke/ and salt etc. DSR 5.4
Supply and fixing if 32mm dia. 02 Mtrs. long G.I pipe (medium class) bracket for mounting of fluorescent/ HPMV/HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 Nos. 40mmX3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-18, Item code- 12.34
Providing of 2X 10 Sq mm PVC insulated and PVC sheathed Aluminum armored cable.Make :- Gloster/ Grandly/ Universal/ Standard/ Havells/CCI
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. DSR-18, Item code- 9.1.2, 2 X 10 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as reqd. (clamped with 1mm thick saddle) 2x 10 sq. mm DSR-18, Item code-7.7.1
P/F 25mmx5mm Copper strip in 40 mm dia GI pipe from earth electrode including connection with GI pipe from earth electrode including connection with GI nut , bolts, spring, washer excavation and re-filling etc. DSR 5.11
S/O 36/ 40 Watt LED batten with integrated LED tube complete in all respect suitable for surface and wall mounting. Make : Havells/Bajaj/ Crompton
S/O 60watt LED street light made up of pressure die cast aluminium housing with high power led as lighting source with IP65/ IP66 protection. Make : Havells/Bajaj/ Crompton
MITTAL TRADING COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .