Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹5.2 L+₹29,625 (6.06%)Rejected-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹5.3 L+₹42,165 (8.62%)Rejected-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L3 | Rejected-AOC Not Lowest |
Tender Value
₹6.4 L
EMD Value
₹12,720
Closing Date
10 Dec 2022, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR MAINT OF INTERNAL WIRING, EXTERNAL ELECT AND OTHER MISC WORK AT DAD MD ACCN, DAD OFFICE, GUEST ROOM AND LEKHA NAGAR MD ACCN AT LANSDOWNE
2022_MES_562738_1
8781/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE I Lansdowne
Class E Cat b i
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹12,720
10 Jan 2023
14 Nov 2022
12 Dec 2022
14 Nov 2022
10 Dec 2022
28 Nov 2022
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down u/s sub-main wiring of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down unservicable MCBs DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc. complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit, "medium grade" (ISI marked) , not less than 20 mm dia duly concealed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per serial Item No 04 herein above but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per serial Item No 04 herein above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per serial Item No 04 herein above but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
All as per serial Item No 04 herein above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including surface rigid PVC conduit/Casing caping," medium grade" (ISI marked), not less than 20 mm dia on wall/ceiling or above false ceiling with fittings (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
All as per serial Item No 09 herein above but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per serial Item No 09 herein above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per serial Item No 09 herein above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or Cona Cat Part No: 9251
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or Cona Cat Part No: 9386
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or Cona Cat Part No: 9301
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make:- Legrand cat No: 6734 55 / Indoasian cat no: 800022 or Cona Cat Part No: 9311
Supply and fixing switch modular single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed. Make:- Legrand cat No: 6734 02 / Indoasian cat no: 800001 or Cona Cat Part No: 9256
Supply and fixing bell push modular single pole one way 6 Amps, 1 module , ISI marked complete all as specified & directed. Make:- Legrand cat No: 673022 / Indoasian cat no: 800007 or Cona cat part No-14011.
Supply and fixing bell ding dong AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals ISI Marked complete all as specified & directed.
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings ISI Marked complete all as specified & directed.
S&F in repairs switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/14111 OF Anchor or HSN 8536/7001 of Cona or Havells Reo Cat Part No-AHESXXW061
S&F in repair switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way complete all as specified and directed.Make:-Cat part no HSN8536/33118 of Anchor or HSN 8536/7081 0f Cona or Havells Reo Cat Part No-AHESXXW201
S&F in repairs, socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed. Make:- Cat part no HSN8536/14302 of Anchor, HSN 8536/7021 of cona or Havells Reo Cat Part No-AHEKP01W063
S&F in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC ISI marked complete all as specified and directed. Make:- Cat part no HSN8536/145045 of Anchor, HSN 8536/7081 of cona or Havells Reo Cat Part No-AHEKUXW063
Supply and fix surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Model: SZSLBMX020 of Shakti or equivalent make of crompton cat no LCTLN-20-CDL/Havells cat no :LHEXACP7FN1W020. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period. Make: Shakti/C&S/Havells/Crompton
Supply and fix surface mounted LED luminiare, 9 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Model: SZSLBMX020 of Shakti or equivalent make of crompton cat no LCTLN-20-CDL/Havells cat no :LHEXACP7FN1W020. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period. Make: Shakti/C&S/Havells/Crompton
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed by Eng-in-Chargemake SZPCLPM020 of shakti/LTESSG20wLED of C&S/Havells cat No: LHEXAYP7PN6K020/Crompton cat bNo:TRP-400-20-57-LM-NSR (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No(iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
S & F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder comlpete all as specified & directed. Make: Wipro/Surya/Havells/Crompton
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed . Make: Legrand/ABB/Schnider
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed . Make: Legrand/ABB/Schnider
Supply & fixing MCB, SPN, AC, 240 volts of 32 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed. Make: Legrand/ABB/Schnider
Supply and fixing MCB SP 6- 32 Amp 240 V AC 10 KA B curve rupturing capacity complete all as specified & directed. Make: Legrand/ABB/Schnider
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
Disconnecting all incoming and outgoing cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to approved nearby workshop, for carrying out maintenance of transformer all as specified in IS -10028 (part III) - 1981 following by Opening of transformer cover, draining out oil, de-tanking core and coil assembly,cleaning, washing of dust and dirt etc from all parts including core and tank, cooling tubes of radiators, re-assembling of core and winding after carrying out necessary repair and replacement of defective items including providing all necessary insulation material of appropriate class including varnishing drying out in vacuum chamber till specified IR values are achieved if required, complete insulation varnishing to be done and providing new gasket, nuts , bolts, and checking of leakages if any,rectifying the same by welding, checking of tap change if found faulty, repair / replace the same etc, replacement of silica gel and reassembling of complete transformer all as directed by Engr-in-Charge , including testing as per relevant IS and transporting back the transformer after repair/maintenance to the site , installing it, reconnecting all the incoming and out going cables by properly using insulation tape and testing complete of following capacities. (a) 100 to 200 KVA 11000/433 Volt Distribution transformer
Supply & Fixing new HV coil of copper conductor suitable for 11 KV distribution transformer complete alongwith insulating material duly varnished by vacuum impregnation (as per sample) and backed coil assembly complete all as specified & directed.
Supply only new LV coil of copper conductor suitable for 415 V distribution transformer complete alongwith insulating material duly varnished by vacuum impregnation as per sample) and backed coil assembly complete all as specified & directed.
Supply only HT bushing with stud , seal etc for 100 KVA to 200 KVA KVA transformer complete all as specified & directed.
Supply only LT bushing with stud , seal etc for 100 KVA to 200 KVA transformer complete all as specified and directed.
Supply only silica gel breather assembly with fresh silica gel for 100 KVA to 200 KVA transformer complete all as specified and directed.
Supply only insulating transformer oil confirming to IS 335 1993 for replacing in power/distribution transformer with dielctric strength not less than 60 KV complete all as specified and directed.
M&L for Filteration/ dehydration and cleaning of transformer oil off line by dehydration plant including testing of samples before and after dehydration and filtration, dielectric strength should not less than 55 KV at 2.5 mm gap after dehydration/filtration all as specified and directed. Note:- For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be include in quoted rate.
Prepration of old surface of distribution transformer 11 KV/433 V for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of tranformer complete all as specified and directed by Engr-in Charge for transformer of capacity upto 200 KVA
M/S Garhwal Enterprises
Panwar Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .