Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | ₹24.7 L | L1 | Accepted-AOC By The Tender Committee |
| 2 | Rejected-Technical VSS 53 CHHEND COLONY ROURKELA 769015 | SUNDARGARH | ODISHA | 769015 | - | - | Rejected-Technical By The Tender Committee |
| 3 | Rejected-Technical | - | - | Rejected-Technical By The Tender Committee |
| 4 | Rejected-Technical PLOT NO 90 286 KHATA NO 125 97 PANDUA NEAR BAIDYANATH TEMPLE PO JARAKA DIST JAJPUR 755050 | JARAKA | JAJPUR | ODISHA | 755050 | - | - | Rejected-Technical By The Tender Committee |
| 5 | Rejected-Technical | - | - | Rejected-Technical By The Tender Committee |
Tender Value
₹24.7 L
EMD Value
₹24,740
Closing Date
24 Apr 2026, 5:00 pmClosed
Municipal Commissioner, RMC
Rourkela Municipal Corporation, Rourkela
Electrical
2026_RMC_127909_1
MC/RMC/24/2026
Open Tender
Electrical Works
45 days
Rourkela
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹24,740
Yes
20 Jun 2026
7 Apr 2026
27 Apr 2026
7 Apr 2026
24 Apr 2026
7 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and erection of 08 Mtrs. long swaged / step down type Steel Tubular Pole (Bottom Specification: 6.00m. Length x 139.70mm. O.D x 4.85mm. Thickness, Top Specification: 2.00m. Length x 88.90mm. O.D x 3.25mm. Thickness ) with earth work in excavation of foundation of size 3’-0” x 3’-0” x 3’-0” = 0.76 Cum in all type of soil including rough dressing and leveling the bed etc. complete with transportation, T&P and labour charges as per the direction of the Engineer-in-Charge. | |||||
| 2Supply of all materials, labor, T&P for providing C.C. (1:1½:3) with hard granite broken chips of size 12mm including cost, transportation, sundries, conveyance, royality of all materials etc. complete as per direction of the Engineer-in-Charge. upto ground level : 1 x 3’-0” x 3’-0” x 2’-8” = 24.00 cft. Couping portion: 1 x 2’-0” x 2'-0" x 2’-0” =8cft. (-) Volume of pole up to top of couping : 3.14 x (0'-5½") /4 x 4'-8"=(-) 0.74 cft.=31.26cft. or say 0.88cum 4nos. | |||||
| 3 | Supply of all materials, labour, T&P and transportation for centering and shuttering of the couping portion etc. complete as per direction of the Engineer-in-Charge. 4 x1’-6” x 1’-6” =9 sq.ft. Or say 0.83 sqm 12no. | 1 | sqm | - | - |
| 4Supply and stringing of 2core 10sqmm unarmoured Al. cable with help of No.8 GI wire including supply and fixing of G.I pole clamp febricated 25mm x 6mm G.I flat etc complete as per direction of the Engineer-in-Charge. (Make: POLY CAB/Havells/Glostar/KEI) | |||||
| 5 | Supply & Stringing Of LT line with 3Ph 5 wire 95mm sq AB cable on 11 mtr long RS Joint Pole with all accessories complete. | 1 | Km | 0.58 | ₹0.58 |
| 6Supply and erection of galvanized 'D' iron complete with suitable pole clamp 75mm x 88mm porcelain shackle insulator & 15mm dia galvanized bolt & nut including painting. | |||||
| 7Supply and fixing of Galvanized stringing screw 12" x 5/8" dia. | |||||
| 8Supply and fixing of Single phase outdoor type panel board made of 16 SWG- C.R sheet of size 3'-0" x 2.'-0" x 1'-5" ( L x B x D) with epoxy grey powder coated. The panel board consisting of the following accessories. (i) Neon Indicator - 3 nos. (ii) Ring Copper Socket (iii) Timer-1 No (iv) Toggele Switch-1 No (v) 32 Amp Single pole Contactor-1 no (vi) Single phase 32 Amp Single pole MCB-2 nos. (vii) Stud Connector-1 no. (viii) Single Phase Copper Bus bar-40nos (ix) Danger Board -1 no. with comple wiring with 10sq.mm / 4sq.mm/2.5sqmm copper wire & the panel board to be fixed of on the pole with help of G.I clamp,nut and bolt ets as per direction of EIC. | |||||
| 9Supply of all materials, labour, T&P and transportation for Febrication of G.I frame (Chhanel size 2'' x 2'' x 1/4 '') including suitable arrangement for fixing of flood lights on the top of the pole as per direction of EIC. | |||||
| 10Supply & Fixing of 300Watt LED Flood light made up of pressure die-cast Aluminium housing with toughened glass and high power LED's and secondary lenses with IP-66 protection. System efficacy > 110LPW 10KV SPD included.Sample to be produced before installation of fittings.Manufacture test certificate of fittings to be submitted after completion of the work satisfactorily. Three Years On-Site Maintenance. (Make: Bajaj /Crompton /Havells /HPL /Wipro /K-Lite /Jaquar) | |||||
stage.html
html • 0.07 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_587257.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.96 MB
BOQ_587257.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid