| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAdmitted-Finance MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | ₹1.6 L | L1 | Admitted-Finance |
| 2 | L2₹1.6 L+₹1,236 (0.77%)Admitted-Finance | ₹1.6 L+₹1,236 (0.77%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | - | - | Rejected-Technical affidavit not enclosed |
| Sl No | Description | Qty | Unit | GANPATI ELECTRICAL AND MECHANICAL WORKS L1 | VEE AUTO TRADERS L2 |
|---|---|---|---|---|---|
| 1.00 | Replacement of damaged/ChokedSuction Pipe line in Emergency OT of GMCH, Jammu along with allied works by way ofProviding and laying of Medical Grade copper pipe for medical gases (Air, Oxygen and Vacuum) as per EN 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-oxidized, non-arsenical, half-hard fully de-greased (designated to R250) along with all allied works necessary for installation, testing and commissioning of pipeline system. It should conform and meet with the latest BSEN 13348:2001 standard. Chemical compositions as per CUDHP to 1190-1 and CWO 24A to EN 1412. Maximum total carbon content 0.20 Mg/dms. The pipes shall be accompanied with manufactures test certificate for the Physical properties & Chemical Composition. The copper pipe should be suitably embossedwiththemanufacturingname/logo
(Make:MEXFLOW/MANDEV/METALALLOY)
Specifications of Medical copper pipe is as below: -
22mm OD x 0.9mm thick (payment shall be made as per actual measurement) | 65 | mtrs | 0 ₹1,20,250 Lowest | 0.02 ₹1,21,030 |
| 1.10 | Replacement of damaged/ChokedSuction Pipe line in Emergency OT of GMCH, Jammu along with allied works by way ofProviding and laying of Medical Grade copper pipe for medical gases (Air, Oxygen and Vacuum) as per EN 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-oxidized, non-arsenical, half-hard fully de-greased (designated to R250) along with all allied works necessary for installation, testing and commissioning of pipeline system. It should conform and meet with the latest BSEN 13348:2001 standard. Chemical compositions as per CUDHP to 1190-1 and CWO 24A to EN 1412. Maximum total carbon content 0.20 Mg/dms. The pipes shall be accompanied with manufactures test certificate for the Physical properties & Chemical Composition. The copper pipe should be suitably embossedwiththemanufacturingname/logo
(Make:MEXFLOW/MANDEV/METALALLOY)
Specifications of Medical copper pipe is as below: -
15mm OD x 0.9 mm thick (payment shall be made as per actual measurement) | 15 | mtrs | 0 ₹25,350 Lowest | 0.02 ₹25,725 |
| 2.00 | Replacement of damaged valve by way of Providing and fitting of Ball valves with brass fitting for regulation of medical gases (Vacuum) of size as below:-
(Complete job includes labour charges, transportation charges, all kinds of taxes etc.
28 mm | 1 | nos. | 0 ₹3,240 Lowest | 0.02 ₹3,283 |
| 2.20 | Replacement of damaged valve by way of Providing and fitting of Ball valves with brass fitting for regulation of medical gases (Vacuum) of size as below:-
(Complete job includes labour charges, transportation charges, all kinds of taxes etc.
22mm | 2 | nos. | 0 ₹4,860 | 0.02 ₹4,802 Lowest |
| 3.00 | Replacement of damaged Medical Gas Terminal Units/Gas outlet Points (B.S.Type) of Emergency OT of GMCH, Jammu by way of providing & fitting of New Gas Outlet point of make Aktiv/MPS/Tri-Tech. The Medical Gas outlet point should have proper colour coding as per the gas being used and it should also have integral check valve to allow removal of housing, front fascia and socket assembly for maintenance without closing down the entire pipeline and the Medical gas outlet points should be CE Certified and shall confirm to latest standard of Health care Facilities. The complete job includes cost of material, all handling & labour charges.
Vacuum | 2 | nos. | 0 ₹5,980 Lowest | 0.02 ₹6,076 |
Tender Value
₹1.6 L
EMD Value
₹4,000
Closing Date
26 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Replacement of damaged Choked Suction Pipe line in Emergency OT of GMCH, Jammu along with allied works.
2026_PWDJK_310130_1
MHDJ/e-NIT 47 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹4,000
17 Sept 2026
16 May 2026
29 May 2026
16 May 2026
26 May 2026
20 May 2026
16 May 2026 - 26 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Replacement of damaged/Choked Suction Pipe line in Emergency OT of GMCH, Jammu along with allied works
MHDJ/e-NIT 47 of 2026-27 Dated: 16.05.2026 Due : 26.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Replacement of damaged/ChokedSuction Pipe line in Emergency OT of GMCH, Jammu along with allied works by way ofProviding and laying of Medical Grade copper pipe for medical gases (Air, Oxygen and Vacuum) as per EN 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-oxidized, non-arsenical, half-hard fully de-greased (designated to R250) along with all allied works necessary for installation, testing and commissioning of pipeline system. It should conform and meet with the latest BSEN 13348:2001 standard. Chemical compositions as per CUDHP to 1190-1 and CWO 24A to EN 1412. Maximum total carbon content 0.20 Mg/dms. The pipes shall be accompanied with manufactures test certificate for the Physical properties & Chemical Composition. The copper pipe should be suitably embossedwiththemanufacturingname/logo (Make:MEXFLOW/MANDEV/METALALLOY) Specifications of Medical copper pipe is as below: - 22mm OD x 0.9mm thick (payment shall be made as per actual measurement) 65 mtrs Excess(+) Full Conversion INR
1.1 Replacement of damaged/ChokedSuction Pipe line in Emergency OT of GMCH, Jammu along with allied works by way ofProviding and laying of Medical Grade copper pipe for medical gases (Air, Oxygen and Vacuum) as per EN 13348:2001, (Medical Grade), Solid Drawn, Seamless, De-oxidized, non-arsenical, half-hard fully de-greased (designated to R250) along with all allied works necessary for installation, testing and commissioning of pipeline system. It should conform and meet with the latest BSEN 13348:2001 standard. Chemical compositions as per CUDHP to 1190-1 and CWO 24A to EN 1412. Maximum total carbon content 0.20 Mg/dms. The pipes shall be accompanied with manufactures test certificate for the Physical properties & Chemical Composition. The copper pipe should be suitably embossedwiththemanufacturingname/logo (Make:MEXFLOW/MANDEV/METALALLOY) Specifications of Medical copper pipe is as below: - 15mm OD x 0.9 mm thick (payment shall be made as per actual measurement) 15 mtrs Excess(+) Full Conversion INR
2 Replacement of damaged valve by way of Providing and fitting of Ball valves with brass fitting for regulation of medical gases (Vacuum) of size as below:- (Complete job includes labour charges, transportation charges, all kinds of taxes etc. 28 mm 1 nos. Excess(+) Full Conversion INR
2.2 Replacement of damaged valve by way of Providing and fitting of Ball valves with brass fitting for regulation of medical gases (Vacuum) of size as below:- (Complete job includes labour charges, transportation charges, all kinds of taxes etc. 22mm 2 nos. Excess(+) Full Conversion INR
3 Replacement of damaged Medical Gas Terminal Units/Gas outlet Points (B.S.Type) of Emergency OT of GMCH, Jammu by way of providing & fitting of New Gas Outlet point of make Aktiv/MPS/Tri-Tech. The Medical Gas outlet point should have proper colour coding as per the gas being used and it should also have integral check valve to allow removal of housing, front fascia and socket assembly for maintenance without closing down the entire pipeline and the Medical gas outlet points should be CE Certified and shall confirm to latest standard of Health care Facilities. The complete job includes cost of material, all handling & labour charges. Vacuum 2 nos. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_1003609.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .