| 1 | L1₹31.4 LAccepted-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.8 L+₹2.0 L (6.33%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹35.4 L+₹3.6 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹35.8 L+₹4.0 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹37.3 L+₹5.5 L (17.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
27 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
SPL REPAIR TO OFFRS MD ACCN BLDG NO P 218 2 AT LANCER LINE AND P 1743 AT SSE AND OTHER CERTAIN SANCTIONED WORKS IN THE AREA OF AGE BR I UNDER GE ARMY CENTRAL JODHPUR (9140/E8)
2022_MES_552727_3
GE/J/A OF 2022-23 (9140/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹75,000
Yes
4 Nov 2022
17 Oct 2022
29 Oct 2022
17 Oct 2022
27 Oct 2022
22 Oct 2022
Amount
Note:- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Replacement/Renewal" unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are requested to quote their rates accordingly.
Taking down or up 25 mm bore GI steel tubing and connection including cleaning for refixing or removal to store, complete all as directed.
All as per Item No. 2.00 here-in-above but 20 mm bore GI steel tubing.
All as per Item No. 2.00 here-in-above but 15 mm bore GI steel tubing.
S&F GI tubing (ISI marked) 25mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floor scomplete all as specified and as directed.
All as per Item No. 5.00 here-in-above but 20 mm bore GI steel tubing.
All as per Item No. 5.00 here-in-above but 15 mm bore including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
Re fixing / Re laying old 25mm bore GI tubing and connections in new or old position including provision of new GI fittings ( as ordered) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed .
All as per Item No. 8.00 here-in-above but 20 mm bore GI steel tubing.
All as per Item No. 8.00 here-in-above but 15 mm bore GI steel tubing.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in coping to parapet or roof kerb including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Supply only integral water proofing compound ISI Marked all as specified.
M & L for mild steel framed work as in brackets etc for cooler stands etc framed steps/stairs etc complete using MS angle iron Steel bars gusset plate etc complete all as specified & directed .
S&F in repair 500 ltrs capacity rotational moulded polythene water storage tanks white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old U/S PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed by Engg.-in-charge. Make:- Sintex / Rotex as approved by GE
All as per Item No. 14.00 here-in-above but 1000 Ltrs tank capacity
Taking down carefully cement conc /spalled out concrete from RCC roof projections, ceiling ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc, complete all as directed by Engr-in-Charge.
M&L for 5 mm thick rendering in CM 1:3 & finishing the surface even & smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc., complete all as specified and as directed by Engr-in-Charge.
Racking out joints/pointing to square rubble masonry, Jodhpur type, regular coursed built in cement mortar, complete all as specified and as directed.
M&L for Keyed pointing to square rubble masonry, Jodhpur type, regular course in CM 1:3, complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 finished surface to be even and smooth without extra cement on stone wall surface, complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:4 finished surface to be fair and even without extra cement on stone wall surface, complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4, on ceiling / facia /RCC chajja etc of concrete surfaces, finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surface of wall including preparation of surfaces, complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surface of ceiling, including preparation of surfaces, complete all as specified and as directed.
M&L for one coat of white wash on old painted surface of ceiling, complete all as specified and as directed.
M&L preperartion of newly plastered surface to remove all depressions etc incl sand papering & obtain a smooth surfaces of wall and applying two coats of wall care putty (in two layers) 2-3mm each layer with fair finished and even surface and applying two coat of plastic emulsion paint, complete all as specified and as directed. Note:- Plastic paint shall be in one or more colours/ shades all as approved by GE.
Preparation of old decorated / newly plastered surfaces of walls and applying two coat of weather proof exterior acrylic emulsion paint including & over one coat of alkali resistant acrylic primer including preparation of surfaces and filling of crades by birla putty complete all as specified and directed.
Complete removal of existing treatment of any description on walls and applying two coat of weather proof exterior acrylic emulsion paint including & over one coat of alkali resistant acrylic primer including preparation of surfaces and filling of crades by birla putty complete all as specified and directed.
Demolition of Cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing debris out of MD land, complete all as specified and as directed by Engr-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
Joint free coloured glazed ceramic tiles (premium quality) digital series of size 300mm x 450mm x 7mm / 350 x 250 x 7 mm thick on vertical surface of wall over and including 10mm thick backing coat in CM 1:3 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles (Highlighter pattern) complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
Joint free non skid ceramic tiles (premium quality), coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work with cement mortar 1:6 also facing, jointing and pointing to match existing work, complete all as specified and directed.
M&L for 18-20 mm thick (telephone black shade) granite stone or sink, as in cooking plateform, wash basin counter top oval type, & similar work, machine cut, mirror polished best quality as per sample, including & over 15 mm thick screeding in CM1:4 including rounding of the edges & providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
Rounding to edges of stone slabs one edge such as in steps, cooking plateform and other similar situations, complete all as specified and as directed.
S&F floor power door stopper of zinc body with magnetic catcher and tounge anodised with hard drawn Zn steel spring, door silencer 150mm long, complete all as specified and as directed.
M&L 50 mm thick PCC 1:3:6 type C -1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair wothout using of extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight complete all as specified and as directed.
S&F 20 mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe, complete complete all as specified and directed.
S&F 25 mm bore gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe, complete complete all as specified and directed.
S&F PVC connections of 15mm size with PTMT nuts of 450mm long, complete all as specified and as directed.
S&F PVC connections of 15mm size with PTMT nuts of 600mm long, complete all as specified and as directed.
S&F Soap Dish, CP cast copper alloy fixed with CP brass screws, complete all as specified and as directed by Engr-in-Charge.
S&F in repair Fancy type Chromium plated over head shower 150 X 150mm size with arm, square shape, single flow (ABS body CP with gray face plate) with Rubit cleaning system, Shower Arm 400X25X25mm square shape for wall mounted showers with flange suitable for 15mm bore pipe, including fixing to steel pipe or union, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar cat No. OHS-1805 (Shower) & SHA-455L400 (Shower arm) / Kohler/ Cera as approved by GE.
S&F CP two way angle bib cock with wall flange, screwed down high pressure,screwed both ends for 15 mm bore iron pipe or for unions complete all as specified and as directed. Make: Model No.LYR- 38041 of JAQUAR make or equivalent model in Kohler/ Cera as approved by GE
S & F in replacement vitreous china ware wash hand basin, white, flat back of size 550 mm X 450 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe,PVC connection15mm size with PTMT nuts of length 450mm long, including pillar tap suitable for wash basin, cast copper alloy, chromium plated, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed. Make:- Cera Cat No. CALBURT S2020137 or equivalent in Hindware / Parryware as approved by GE
S&F stainless steel sink with drainage board, for kitchen or laboratory, made of stainless steel 1 mm thick, with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe, over all size 9q5 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed. Make : Nirali/ Jayna/ Bluestar as approved by GE.
S&F stainless steel plate rack of size 760mm X 600mm X 200mm of approved pattern made out of stainless steel sheet 0.50 mm thick suitale for stacking 15 Nos Plates with round 8mm dia rods complete all as specified and directed. Make : Nirali/ Jayna/ Bluestar as approved by GE.
S&F in replacement corner glass shelf with CP frame toughned glass with brackets, complete all as specified and as directed. Make : Jaquar Cat No. CAN 1173 or equivalent in Kohler/ Cera as approved by GE
S&F in replacement MS chromium plated peg set of five fixing with wall, complete all as specified and as directed.
Writing letters or figures (Black Roman, Italic or Indian not exc 30cm high with thick paint , complete all as specified and as directed.
S&F in replacement two piece wall hung extended EWCs with seat cover and cistern with twin flush fittingsand mild steel chromium plated or aluminium hinging device and 'P' trap connecting to drain pipe and flushing pipe etc.,& provision of cement concrete making good to as existing floor, complete all as specified and as directed. Make:- Cera Cat No. S1031101 P Trap & S1060101 Cistern & B1510101 Carina Seat Cover & B1810102 Twin Flush Fittings or equivalent in Hindware / Parryware as approved by GE
S&F in replacement Pillar taps 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat No. ALI-85001 or its equivalen model in equivalent in Kohler/ Cera as approved by GE.
S&F single towel rail 600mm long fixed with chormium plated brass screws, complete all as specified and as directed. Make : Jaquar Cat No. AKP-35711P or equivalent in Kohler/ Cera as approved by GE.
Dismantling of cast iron of CI drain pipe/PVC (SWR) pipe jointed in cement mortor of size 110/100mm bore as directed
Dismantling of cast iron of CI drain pipe / PVC (SWR) pipe jointed in cement mortor of size 75mm bore as directed
S&F 100mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints laid in trenches, including cutting hole where required, complete all as directed.
S&F 100mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints fixed to wall with suitable clamps, including cutting hole where required, complete all as directed.
S&F 75mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints laid in trenches, including cutting hole where required, complete all as directed.
S&F 75mm bore spun cast iron (soil waste and vent) pipes in any length with or without ears with cement joints fixed to wall with suitable clamps, including cutting hole where required, complete all as directed.
S & F cast iron bends [any radius], diminishing pieces or tapers [larger bore measured] of 100mm bore, for cast Iron soil / waste / vent pipes complete all as specified and as directed.
S&F100mm CI branch pieces single socketed 'Y' equal or unequal, complete all as specified and as directed.
S&F 75mm CI branch pieces single socketed 'Y' equal or unequal, complete all as specified and as directed.
S&F 100mm dia CI bend with oval acess door fixed to pipe, complete all as specified and as directed.
S&F 75mm dia CI bend with oval acess door fixed to pipe, complete all as specified and as directed.
S&F 100mm dia CI vent cowl fixed to pipe, complete all as specified and as directed.
S&F100mm CI branch pieces double socketed 'Y' equal or unequal, complete all as specified and as directed.
S&F 75mm CI branch pieces double socketed 'Y' equal or unequal, complete all as specified and as directed.
S&F 100mm dia CI connector of length 30 cms including cutting of holes with lead joints, complete all as specified and as directed.
S&F 100mm dia CI floor trap plain grating including jointing with solvent cement , complete all as specified and as directed.
S&F Cast iron nahani trap with CP grating out let diameter 100mm including jointing to waste pipe fixed in cement mortar 1:1, complete all as specified and as directed.
S&F in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down shutters of any description area exc. 1sqm and not exc. 2 sqm each, complete all as specified and as directed by Engr-in-Charge.
Taking down Shutters of any description and refixing the shutters in the same opening of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed.
Taking down of steel window and ventilators, complete all as directed by Engr-in-Charge.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars, complete all as specified and as directed by Engr-in-Charge.
S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, complete all as specified and as directed by Engr-in-Charge.
S&F rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work conforming to Fe-290Gde E-165 complete all as specified & directed by Engineer-in-charge
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
M&L for solid PVC door frame of size 50x47mm made out of 5mm thick PVC sheet reinforced with MS square tube, complete all as specified and as directed.
S&F of aluminium anodized, barrel tower bolt extruded section of size 150 mm long, complete all as specified and as directed.
S&F aluminum anodised handle extruded section of size 150mm long, complete all as specified and as directed.
S&F of aluminium alloy anodised sliding door bolt with hasp and staple bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and as directed.
S&F of stainless steel butt hinges 100mm size, include screws or bolts, nuts and washers to match the butt hinge, complete all as specified and as directed.
S &F of mild steel butt hinges 100mm size, complete all as specified and as directed.
S&F 100mm size single action door spring hinge, complete all as specified and as directed.
S&F for 3mm thick plain glass ordinary quality & glazing, complete all as specified and as directed.
S&F in replacement stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.00 mm with necessary fitting on steel/ wooden surface, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth, including & over a coat of pink primer including preparation of surfaces, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth, including & over a coat of red oxide primer including preparation of surfaces, complete all as specified and as directed.
Preparation of old painted wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed .
Preparation of old painted steel surfaces of any description, not otherwise described over 10cm width and girth and applying one coat of synthetic enamel paint complete all as specified and as directed .
Taking out from position framed woodwork as in cupboards/cabinets etc with all fittings ,shutters, shelves, drawers etc in any position fixed in walls or floors & removal of the rubbish outside MD land all as directed at site for overall sizes exc 0.50 sqm but not exc 4.00 sqm & depth not exc 60cm, complete all as directed.
Providing and fixing polyvinyl chloride (PVC) sheet frame UPVC Coated Celuka printed in one of two different colours( with wood grain printed pattern /ivory colour finish) of width 150mm & 18mm thickness made out of extruded 18mm PVC sheet and joined with suitable Cement Solvent adhesive and screw.The frame shall be fixed to the wall using 75mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 3 Nos. of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc, complete all as specified and as directed by Engr-in-Charge.
M&L for 18 mm thick solid PVC sheet UPVC Coated Celuka printed in one of two different colours( with wood grain printed pattern /ivory colour finish) as in kitchen cabinet shutters ,all round body of cabinets , shelves ,drawers etc cut to required size jointed with solvent cement & steel screws etc., complete all as specified and as directed.
Extra over solid PVC sheet for fixing 18 mm width & 2-3 mm thick PVC coloured lipping of approved design & colour fixed with solvent cement or headless nails, complete all as specified and as directed.
S&F '0' degree clip type self closing hinges for cabinets fixed with cadimum coated screws, complete all as specified and as directed.
S&F 100mm size bright finished chromium plated steel handle of approved shape & design fixed with cadmium coated screws on the kitchen cabint shutters, complete all as specified and as directed.
S&F 75mm size bright finished chromium plated steel handle of approved shape & design fixed with cadmium coated screws on the kitchen cabint shutters, complete all as specified and as directed.
S&F magnetic catches for cabinets of size 50 mm complete with striking plate & magnetic stud, complete all as specified and as directed.
S&F drawer runners folding type with guide channels & sliding channel with approipiate ball bearing/ rollers etc complete to obtain smooth movement of the drawers.
M&L for stainless steel tray as per trade pattern of various sizes for drawer to keep the kitchen utensil as directed by Engineer-in-charge
S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
All as per item No 112 here-in-above, but except stone.
Extra over square rubble stone walling, Jodhpur type, regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed.
Sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
Cutting chases in stone wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
Precast cement concrete block masonry using PCC 1:2:4, type B-1 solid blocks, thickness exceeding 10 cm and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
Taking down existing roof treatment in any postion and demolition of cement concrete any thickness on RCC roof slab and debries to be disposed out of MD land, complete all as directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate in roof padding , the surface of concrete is to be finished even and fair with out using extra cement complete all as specified and as directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following stage as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 2.25 Kg/Sqm using butane torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : 40 MM thick PCC 1:2:4 type B-1 using 12.5mm graded crushed stone aggregate in roof padding for maintain slop on roof finished even and smooth with using extra cement NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause No. 21.3, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item.
Complete removal of existing treatment of any description on walls
Preparing new plastered or unplastered surfaces and applying two coat wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the wall surfaces and applying two coats of oil bound distemper, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
Joint free non skid ceramic tiles (premium quality), coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles, over & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
M&L for Double charged light shade Vitrified Ceramic tiles, 10 mm thick (square/ rectagular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, including & over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed. Make : Somany/ Kajaria/ Orient as approved by GE.
All as per item No 123 here-in-above, but as in skirting / dado including & over 10 mm thick in CM 1:4
M&L for cement concrete parking tiles of 30cmx30cmx10 mm thick, set, jointed and pointed in white cement and pigment match to colour, laid over and including screed bed or bedding layer of 20mm thick in CM 1:6 complete all as specified and as directed.Make :- Johnson ( Endura) or equivalent make as approved by GE.
S&F in replacement chromium plated fancy type quarter turn 15mm bore bib cock with wall flange, complete all as specified and as directed. Make : Jaquar Cat No. FUS-29037 or equivalent in Kohler/ Cera as approved by GE
S&F in replacement angular Stop cock wall flange chromium plated fancy type quarter turn 15mm bore, complete all as specified and as directed. Make : Jaquar Cat No. FUS-29053 or equivalent in Kohler/ Cera as approved by GE
S & F in repair CP wall mixer with telephonic shower arrangement ,connecting legs and wall flanges but with out crutch and telephone shower complete all as specified and as directed. Make: Jaquar Model No.FUS-29281 & HSH-1937 or equivalent model in Cera / Hindware / Johnson
S&F in replacement of single lever basin mixer wall mounted consisting of operating lever, wall flange, nipple & spout complete all as specified and as directed. Make: Jaquar Model No FUS-29233K & ALD-233 or equivalent model in Cera / Hindware / Johnson
S & F CP Health faucet with 1200 mm long & 80 mm dia flexible steel tube with wall hook with Non Return Valve [back flow preventer] complete all as specified and as directed. Make: Model No.ALD-573 of JAQUAR make or equivalent model in Cera / Hindware / Johnson
Rounding to edges of stone slabs one edge, full round moulding with such as in steps, cooking plateform and other similar situations, complete all as specified and as directed.
S & F 75mm dia out let, PVC ( SWR) floor trap plain with grating including jointing to waste pipe with solvent cement, complete all as specified and as directed.
M&L factory Made flush shutters, 35 mm thick solid core with block board core construction as per IS 2202(part-I, 1999) . The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
M&L 35mm thick factory made 2nd class hard wood glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and as directed.
M&L for fabrication of powder coated aluminum section glazed windows/louvered ventilators frame etc (minimum thickness of powder coating 50 micron) for frames, aluminium section weighing 0.55 kg/m with or without rebate for hinged/sliding windows (two track/three track), ventilators etc, appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM with louveres having suitable mechanism for tilting, 'U' shaped fillets for securing jalies etc & the likes & fixed in position, complete all as specified and as directed by Engg.-in-charge. Note : Glass panes & aluminium wiremesh shall be measured & paid for seperately.
S&F powder coated anodised aluminium deco grill as per sample fixed to aluminium frame work of windows & ventilators, complete all as specified and as directed.
S&F powder coated aluminium window/ ventilator shutter (fixed type) powder coating of any colour (Thickness of powder coating not less than 50 micron), aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc., complete all as specified and as directed by Engr-in-Charge.
S&F for 4 mm thick figured , pin headed glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane, complete all as specified and as directed by Engr-in-Charge.
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft /loose soil, complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and as directed .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm, complete all as specified and as directed by Engr-in-Charge.
Removing excavated soil not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
M&L for hard core broken stone of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, water and rammed to a true surface, with 8-10 tonne power roller, complete all as specified and as directed by Engr-in-Charge.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation & filling and sub base, complete all as specified and as directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in floor finish, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, surface channel, DPC, pier caps, bed blocks, for hold fast etc., including mixing with WPC and necessary form work, complete all as specified and as directed by Engr-in-Charge. Note:- WPC shall be measured and paid separately.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint of approved quality & tint, over & including one coat of chalk white, complete all as specified and as directed.
Precast cement concrete block masonry using PCC 1:2:4, type B-1 solid blocks, 10 cm thick and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
M&L roughly squared stone lintels hammer dressed on face and soffits,hoisted, set and pointed in cement mortar 1:6 complete.n exc 3m in length complete all as specified and as directed .
M&L for machine cut kota stone slab 18 to 20mm thick as in flooring, cooking plateform, laid and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in CM 1:6, complete all as specified and as directed.
M&L for machine cut kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar laid and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM 1:4, complete all as specified and as directed.
M&L of 18 to 20mm thick machine cut KOTA stone slab as in shelves (Single piece) fixed in walls machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, including rubbing and Mirror polishing, complete all as specified and as directed by Engr-in-Charge.
S&F pressed steel frames of size 165X60mm of 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., complete all as specified and as directed.
M&L factory Made flush shutters, 40 mm thick solid core with block board core construction as per IS 2202(part-I, 1999), both sides covered with decorative face veneer with lipping frame to match, The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
S&F flat iron for hold fast and similar work conforming to Fe-290 Gde-E-165 fixed with welding and necessary item, complete all as specified and as directed.
M & L in replacement of fabrication of pressed steel cupboard shutters using 1.00 mm thick MS plain sheet & with frame 1.25 MM thick bent to shape incl two coats of syn enamel paint on internal surfaces & two coats of hammer tone finish on external surfaces alongwith locking arrangement mortice lock handle etc complete all specified and directed.
Use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, shelves etc. including support of fair finished surfaces, complete all as specified and as directed by Engr-in-Charge.
Use and waste of formwork to sides and soffits of slabs not exc. 200mm thick and similar works fair finished surfaces of concrete, complete all as specified and as directed by Engr-in-Charge.
Form work to edge of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete walls, floor and roofs not exc 20cm wide and side of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm but not exc 20cm wide with fair finished surfaces, complete all as specified and as directed by Engr-in-Charge.
S&F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam, slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clip, complete all as specified and as directed by Engr-in-Charge.
S&F mild steel TMT bar 5 dia and over upto and including 10mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc., hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clip, complete all as specified and as directed by Engr-in-Charge.
M&L RCC, M-25, design mix (using 20mm graded aggregate) as in slab supported on wall, roof slab, chajja and in shelve etc., complete all as specified and as directed by Engr-in-Charge.
M&L RCC, M-25, design mix (using 20mm graded aggregate) as in beam, cantilevers, bressummers, lintel overone meter span, complete all as specified and as directed by Engr-in-Charge.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
M&L brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms , moulds , mitred/stopped ends etc. complete all as specified and as directed .
Add or deduct from above item for each 25 mm girth or part there of over or under 30 cm (item is for adjustment of rate).
E/M ITEMS Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces, complete all as directed.
Taking down unserviceable sub main wiring with copper/aluminium conductor,PVC insulated,unsheathed cable of any size drawn through and including rigid PVC or PVC casing caping including earth wire and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
M&L modular point wiring using approved colour coding (Red , Black and Green for single phase circuits) as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLSH cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 1 module modular cover plate(ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & sheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
All as per serial Item No.175.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per serial Item No.175.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and as directed.
All as per serial Item No.175.00 above but for 16 Amps 3 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 2.50 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F switch piano, modular type, single pole, one way, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F switch piano, modular type, single pole, one way, 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F modular bell push 6 Amp, 1 module, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F bell electric multi music type type 230 volts single pole, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
S&F socket outlet, modular type, single pole, 2 in 1, 3 Pin, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, modular type, 2 in 1 single pole, 3 Pin 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F modular fan step regulator, 120W, 2 module, hum free and connecting electrically, ISI Marked, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
M&L point wiring using approved colour coding (Red , Black and Green for single phase circuits) as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLSH cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with plastic laminated sheet (ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & sheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
All as per serial Item No.193.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per serial Item No.193.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and as directed.
All as per serial Item No.193.00 above but for 16 Amps 3 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 2.50 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, single pole, 2 in 1, 3 Pin, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, 2 in 1 single pole, 3 Pin 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F fan step regulator, 120W, 2 module, hum free and connecting electrically, ISI Marked, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, as in repairs, including taking down old u/s material complete all as specified and as directed. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
S&F lamp holder insulated body polycarbonate type with back plate, including 9W LED lamp complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
S&F in replacement of ceiling fans with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) connecting up with and including three core flexible PVC insulated multi stranded copper condutor of size 1.0 sqmm from ceiling rose/ conector to fan (earth wire to connected to fan hook), ISI marked, complete all as per directed and specifed Make :- Havells/Orient/Usha.
Taking down and refixing Exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan including filling cavities with filler, one coat after cleaning all dust etc., complete all as directed. applying two coats of synthetic enamel paint over one coat of red oxide primer over 10cm width or girth, complete all as specified and as directed by Engr-in-Charge.
Supply, fixing, testing & commissioning of LED street light fitting 35 Watt 230 V AC, IP-65 protection, single piece pressure die cast aluminium alloy housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and contror gear compartment with high voltage surge protection device upto 4.5 KV, Prewired including 1.6 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable, as in repairs, including taking down old u/s material complete all as specified Make : Philips/ Bajaj/ Havells
S&F Prewired distribution board (sheet metal enclosures) with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, SPN 4 way, 240 volt, as in repairs, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F Prewired distribution board (sheet metal enclosures) with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, SPN 8 way, 240 volt, as in repairs, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F Prewired distribution board (sheet metal enclosures) with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, SPN 12 way, 240 volt, as in repairs, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F MCB single pole 240 volts rating from 5 to 30 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in repairs, including taking down old u/s materialcomplete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 240 volts rating from 40 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection,as in repairs, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 240 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection,as in repairs, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 6.00 Sqmm and one run of 6.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 6.00 sqmm cable with one run of 6.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
S&F for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 6.00 Sqmm and one run of 6.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) surface mounted in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 6.00 sqmm cable with one run of 6.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
S&F for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 4.00 Sqmm and one run of 4.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 4.00 sqmm cable with one run of 4.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame, 4 Pole MCCB 160A, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, as in repairs, including taking down old u/s material, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider Note : MCCB & MCB shall be measured and paid for separately.
S&F MCCB, 'A' Frame, thermal adjustable magnectic setting, Ics = 75% 36 kA, 415V, 100 Amp, 4 Pole with over load and short circuit protection, suiatble for item No.124.00, (ISI marked), as in repairs, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F RCBOs 4 Pole, 300mA, 63 Amps, for earth leakage, overload & short- circuit protection, (ISI marked), as in repairs, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA single pole and neutral enclosure with two pin and earth plug socket complete with one single pole , complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
Taking down and refixing only including connecting meter
M&L in repairs for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking out old unserviceable cable complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core including taking out old unserviceable cable complete all as specified and as directed.
S&F LED light fitting 1X9W bulk head luminaries, with lamp holders including 9 W LED bulb including taking down old fitting complete all as specified and as directed Make : Havells/ Bajaj/Philips/CG
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. Make : Philips/ Bajaj/ Havells
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer, complete all as specified and as directed by Engg.-in-charge. Note :- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 300x180mm x40 mm, complete all as specified and as directed.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore, complete all as specified and as directed. Make : Prakash/ Tata/ Jindal
NOTE:- (i) The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/S KAUTILYA GARG
M/S IK CONSTRUCTION
SUNDER LAL DAVE
Mahesh Dave
M/s Ajay kumar Garge
Bhairav Infra Projects
JB INFRA
Bhawna Emporium
M/S SUMAN ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .