REPAIR/ MAINT OF HT SYSTEM AND OTHER E/M WORKS AT TEZPUR UNDER GE (AF) TEZPUR
2023_MES_630498_1
CWE(AF)/TEZ/TOKEN-32 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Tezpur
₹80,000
Yes
28 Mar 2024
30 Nov 2023
2 Jan 2024
30 Nov 2023
29 Dec 2023
15 Dec 2023
Amount
Servicing, Repairing and Maintenance of existing HT 11 KV,400/630/800 Amps rating VCBs (Make : Crompton Greaves/ Areva ‘Alstom’/ Schneider/ Seimens/ ITE/Andrew Yule) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11KV indoor/ outdoor VCBs, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs, complete all as specified and directed. Notes:- (i) The work shall be carried out by agencies approved by State/Central electricity board necessary test certificate should be furnished by the agencies and to be kept on record. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Servicing, Repairing and Maintenance of existing HT 33 KV,1250 Amps rating VCBs (Make : Areva ‘Alstom’) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 33 KV indoor outdoor VCBs,checking of quality of vacuum interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed. Notes:- (i) The work shall be carried out by agencies approved by State/Central electricity board necessary test certificate should be furnished by the agencies and to be kept on record. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Servicing, Repairing and Maintenance of existing HT 11 KV, 630 Amps rating Ring Main Unit, SF 6 insulated isolator (Make : Crompton Greaves) by removing from housing, overhauling the mechanical parts and periodic maintenance servicing of 11 KV indoor / outdoor RMUs, including cutting, fabrication and welding of gas chamber and checking of quality of interrupter, insulation resistances, static contact resistance, testing ( IR value, Ratio Test, Polarity) and connection checking of 11 KV Current Transformer ( Set of Three) by primary injection kit ,testing and calibration of relay ( Set of, Two Over Current and One Earth Fault Relays) by secondary injection kit including,all other functional tests of the VCB panels including for CTs, PTs,complete all as specified and directed. Notes:- (i) The work shall be carried out by agencies approved by State/Central electricity board necessary test certificate should be furnished by the agencies and to be kept on record. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only, panel indicating lamp fitting, LED suitable for110 volt/ 230 volt AC with base complete all as specified (Make: L&T / Siemens / STS/AE)
Supply Only, Breaker Control Switches,TNC (Trip,Neutral and Close), rating 25 Amps with contact arrangement 1Trip + 1Close, barrel lock mounting type, suitable for 11 KV VCB panels, complete all as specified. (Cat No 73257SEB90PGBB of Make L&T or equivalent Model of Make: Switron / Recom /Kaycee / Areva)
Supply Only, heater with heater switch & thermostat suitable for 11KV VCB panels, 80 watts, as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/ Seimens/ITE/ Andrew Yule)
Supply Only, HT Current Transformers, single phase indoor solid state (Resin cast) 11 KV, ratio 150/5A, accuracy class 5P10, rated burden 15VA, STC 13.1 KA for 1second,suitable for VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule) Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only,microprossesor based feeder protection neumerical relay with overcurrent, earth-fault, phase-discontinuity, negative-phase sequence and thermal-overload protections, inrush current detection, reclosing and measurement,preconfigured functionality facilitates, configurable binary inputs/outputs using local HMI or communication interface,modbus and IEC 60870-5-103 protocols supports,universal power supply 24-265 V AC/DC,suitable for 11 KV VCB panels,complete all as specified. (Cat No REJ601 of Make ABB or equivalent Model of Make: Schneider/ Seimens) Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only,auxiliary relay with high-speed operation,rated voltage 24Volts DC,operating range - 30% to +10% of rated voltage,frequency 50 Hz +/-5%,pick-up voltage < 80%,Drop-off voltage > 20% ,Pick-up time 20-30ms,contacts 6N/O + 1N/C,suitable for 6.6 KV VCB panels,complete all as specified. (Type PQ8n of Make ABB or equivalent Model of Make: Schneider/ Seimens) Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only,Vacuum Interrupter Assembly with Flex connection (R Phase, Y Phase & B Phase) suitable for 11 KV,630/800 Amps VCB Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule) Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply,installation,testing and commissioning of, Motor with Gear Assembly,110 Volts/230 Volts AC (Make Bosch/ Webtool/Ralliwolf) suitable for 6.6 KV VCBs as per OEM's specifications,complete all as specified and directed. (OEMs:-Crompton Greaves/ Areva ‘Alstom’/Schneider/Seimens/ITE/ Andrew Yule) Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only base mounting type power pack with capacitor back up unit input voltage 230 V, output voltage 110 Volt DC, stored output 100 W sec, non store output 100W, with mains ON indicator,suitable for 11 KV VCB panels,complete all as specified. [Cat No. “CPP-1-U110-W100” of Make “Alen” or equivalent Model of Make ‘Jyoti/GE’] Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only, fibre panel spout, 12Kv,50/60 Hz,suitable for 11 KV, 630/800 Amps VCB Panels (ABB VD4 11KV Monobloc 1250Amps) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves)
Supply Only, Epoxy Body,suitable for 11 KV, 630/800 Amps VCBs (Vacuum Switchgear Type VMX) as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves)
Supply Only,Release / Closing Coil,30V DC,suitable for 11KV/33 KV,630/800/1250 Amps rating outdoor VCB panels as per OEM's specifications,complete all as specified. (Code No.52747/2 (Old)/A 6111(New) of OEM Areva ‘Alstom’)
Supply Only,aluminium VCB pad clamp and connector with 06 (Six) Nos. of bolt with nut arrangement,suitable for 33 KV,1250 Amps rating outdoor VCB panels as per OEM's specifications,complete all as specified. (OEM:-Areva ‘Alstom’)
Materials and Labour for protection of aluminium VCB pad clamp and connector for 11KV/33 KV,400/630/800/1250 Amps rating indoor/outdoor VCB panels with with anti corrosive gel as per OEM's specifications, complete all as specified and directed. (OEMs:-Crompton Greaves)
Supply,installation,testing and commissioning of,Non Latching Self Powered Numerical Protection Relay,for VCB/RMU,18 To 52 V & 75 To 250 V designed for use in unmanned substations where a dependable auxiliary power source is not available,designed to derive power for its operation from main current transformers,comprising integrated communication protocols for SCADA compliance,features of IDMT,as well as instantaneous protection for both over current & earth elements,suitable for accomplishing Digital filtering of measured quantities by using discrete Fourier analysis to suppress high frequency harmonics and transient DC components induced by faults or system operations and with front panel features of a 8-button keypad & a 16x2 LCD display for providing an easy user interface,complete all as specified and directed. [Cat No.CGI 14S of CG or equivalent Model of Make C&S/Seimens/ Schneider] Note: The Contractor should submit the individual test certificate duly mentioned with Sr No. Make and year of manufacture etc.
Supply Only, SF6 Interrupter Assembly with Flex connection (R Phase, Y Phase & B Phase) suitable for 11 KV,630/800 Amps RMU Panels as per OEM's specifications,complete all as specified. (OEMs:-Crompton Greaves)
Supply only SF6 gas for 11 KV,630/800 Amps RMU Panels as per existing,complete all as specified.
Supply only Terminal Protector / Right Angle Rubber Boot 11 KV,630/800 Amps RMU Panels as per existing,complete all as specified. (OEMs:-Crompton Greaves)
Disconnecting all Primary and Secondary connection from existing 5 MVA,33 KV/11 KV Power Transformer,opening top lid cover of transformer and disconnecting all internal connection of EHV/HV side for periodical maintenance,such as replacement of gasket set,burnt spindle,damaged EHV/HV porcelain bushing,surge arrestor,re-fixing of top lid cover including refilling/topping up dehydrated new transformer oil,reconnection of EHV and HV connection, including carried out following caliberation, testing/checking of power transformer 33/11KV. (a) IR value of winding. (b) Checking for the operation of alarm/triping function bucholtz relay, PRV, oil & winding temperature contacts/relays. (c) Earth Resistance checking testing on load as per OEMs specifications and commissioning,complete all as specified and directed. Notes: - (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after. (iii) Gasket set, EHV/HV side porcelain bushing,spindle for EHV/HV side and silica gel breather etc. for replacement will be measured and paid under relevant items of this BOQ. (iv) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge.
Supply Only, Breather assembly, filled with silica gel suitable for 5 MVA, 33 KV/11 KV Power Transformer,as per OEM's specifications,complete all as specified.
Supply Only,6mm-8mm thick gasket for top lid cover,EHV and HV bushing assembly of 5 MVA 33 KV/11 KV Power Transformer,as per OEM's specifications,complete all as specified.
Disconnecting all incoming and outgoing electrical connections,opening top lid cover of 33 KV CT PT combine unit with 1 Nos.CT / 1 No. PT coils,outdoor oil cooled type,3 Phase 4 Wire,50Hz,Power (kw) 100VA, Insulation Level (kv) 70/170KVP and disconnecting all internal connection for repairs and periodical maintenance, such as replacement of gasket set,replacement of silica gel,reassemblying of parts,re installation,testing and commissioning,complete all as specified and directed. Note: - Transformer Oil for replacement/ topping up will be measured and paid separately.
Supply and Fix,lightning arresters metal oxide type,consisting of a stack of zinc oxide discs encapsulated in heat shrinkable sleeve,arranged in hermatically sealed porcelain housing,complete with all fittings, transmission class,discharge capacity 65 kilo amp,suitable for 33000 Volts, station class type complete all as specified and directed.
Supply Only, porcelain bushing of HV side of transformer, conforming to IS:3347(Part-I) & IS:7412 suitable for 5 MVA 33 KV/11 KV Power Transformer,all as per OEM's specifications,complete all as specified.
Supply Only, porcelain bushing of EHV side of transformer,conforming to IS:3347(Part-I) & IS:7412 suitable for 5 MVA,33 KV/11 KV Power Transformer,all as per site,complete all as specified.
Disconnecting HV/LV Connections of Transformer, including disconnecting of earthing lead, unscrewing nuts, bolts and washers, testing their un-serviceability (Open and Closed circuit test) with the help of composite unit of Transformer 100 to 630 KVA 11000/433, and isolation transformer of any capacity complete all as specified and as directed by Engineer-in-Charge. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iii) Spare Parts for replacement such as gasket, spindle etc. and topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after.
Taking down carefully defective transformer of 100 to 160 KVA 11000/433 indoor/outdoor and from foundation base including draining out old transformer oil complete carefully and keeping the same in a cleaned container in safe custody for re use after repair works of transformer and transportation from site to workshop at Tezpur for repair and back to site after repair, connecting HT, LT as well as Earthing Lead to existing system, testing and commisioning all as directed by Engineer-in-charge. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Super enameled /paper coated copper wire/strip for rewinding of defective HV/LV coils will be measured and paid seperately under respective items of this BOQ. (iii) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iv) Spare Parts for replacement, topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after.
Taking down carefully defective transformer of 200 to 400 KVA 11000/433 indoor/outdoor and from foundation base including draining out old transformer oil complete carefully and keeping the same in a cleaned container in safe custody for re use after repair works of transformer and transportation from site to workshop at Tezpur for repair and back to site after repair, connecting HT,LT as well as Earthing Lead to existing system, testing and commisioning all as directed by Engineer-in-charge. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Super enameled /paper coated copper wire/strip for rewinding of defective HV/LV coils will be measured and paid seperately under respective items of this BOQ. (iii) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iv) Spare Parts for replacement, topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after.
Taking down carefully defective transformer of 500 to 630 KVA 11000/433 indoor/outdoor and from foundation base including draining out old transformer oil complete carefully and keeping the same in a cleaned container in safe custody for re use after repair works of transformer and transportation from site to workshop at Tezpur for repair and back to site after repair, connecting HT,LT as well as Earthing Lead to existing system, testing and commisioning all as directed by Engineer-in-charge. Notes:- (i) The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge. (ii) Super enameled /paper coated copper wire/strip for rewinding of defective HV/LV coils will be measured and paid seperately under respective items of this BOQ. (iii) Testing(s) shall be done through State Electrical Licencing Board's valid electrical licence holder for the appropriate class/category of the work as approved by the Engineer in Charge. (iv) Spare Parts for replacement, topping up of transformer oil and dehydration & filteration of transformer oil will be measured and paid seperately under respective items of this BOQ here in after.
Opening Top Lid Cover of Transformer 500 to 630 KVA 11000/433 indoor/outdoor, disconnecting all Internal Connections of HT/LT Side for Periodical Maintenance such as Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to removed Dust/Sludge on Core and Coil, Cleaning of Oil Tank to removed Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. complete all as specified and as directed.
All as per Item No.34 above, but Transformer 200KVA TO 400KVA 11000/433.
All as per Item No.34 above, but Transformer 100KVA TO 160KVA 11000/433. NOTE FOR ITEM No. 34 TO 36 :- (a) Cost of Transformer Oil for Cleaning by Hosing down shall deemed to be included in the QUOTED UNIT RATE. (b) Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side, dehyderation filteration of Transformer Oil and horn surge arrester etc. for replacement shall be measured and paid under relevant item.
Supply Only, silica gel suitable for breather assembly of 100 KVA to 630 KVA transformers,as per OEM's specifications, complete all as specified.
Supply Only,6mm-8mm thick gasket for top lid cover,HT and LT bushing assembly of 100 KVA to 160 KVA transformers,as per OEM's specifications,complete all as specified.
Supply Only,6mm-8mm thick gasket for top lid cover,HT and LT bushing assembly of 200 KVA to 400 KVA transformers,as per OEM's specifications,complete all as specified.
Supply Only,6mm-8mm thick gasket for top lid cover,HT and LT bushing assembly of 500 KVA to 630 KVA,11/0.433 KV transformers,all as per OEM's specifications,complete all as specified.
Supply Only,12 mm dia.,brass spindle with 05 Nos. Nuts, check nuts and washers, ISI Marked (IS: 3347) suitable for bushing assembly of 100 KVA to 630 KVA ,11/0.433 KV transformers,all as per OEM's specifications, complete all as specified.
Supply Only,16 mm dia.,brass spindle with 05 Nos. Nuts, check nuts and washers, ISI Marked (IS: 3347) suitable for bushing assembly of 100 KVA to 630 KVA ,11/0.433 KV transformers,all as per OEM's specifications, complete all as specified.
Supply Only,20 mm dia.,brass spindle with 05 Nos. Nuts, check nuts and washers, ISI Marked (IS: 3347) suitable for bushing assembly of 100 KVA to 630 KVA ,11/0.433 KV transformers,all as per OEM's specifications, complete all as specified.
Dehydration, filtration, de-sludge of transformer oil in situ for 33/11KV transformers / 11/0.433 KV transformers of any rating,by means of centrifugal filtration plant to achieve dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, complete all as specified and directed. (NOTE: Transformer oil used for topping up will be measured and paid separately)
Supply, filling in, dehydration and filtration of new transformer oil, having dielectric strength not less than 40 KV (rms) with gap of 2.5 mm, conforming to IS: 335-1993, for topping up /replacement of transformer oil complete all as specified and directed. (Make: Shell/Gulf/Power Oil/Servo)
Supply Only,super enameled copper wire of existing gauge for HV Coil of transformer,all as per existing, complete all as specified.
Supply Only,super enameled /paper coated copper strip of existing size for LV Coil of transformer,all as per existing, complete all as specified.
Supply Only,silica gel breather assembly in PVC container with fully transparent body, filled with silica gel not less than 0.50 Kg. per container for 100 KVA to 630 KVA transformers,as per site, complete all as specified.
Materials and Labour for applying one coat of synthetic enamel paint on old painted exposed steel surfaces of transformer 500 KVA to 630 KVA, 11/0.433 KV transformers in situ by spray painting, after preparation of surface, including writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high, stops commas, short lines, dashes, hyphens, brackets etc.for marking SM/MES No, Capacity etc. for the transformers, complete all as specified and directed.
Materials and Labour for applying one coat of synthetic enamel paint on old painted exposed steel surfaces of transformer 200 KVA to 400 KVA, 11/0.433 KV transformers in situ by spray painting, after preparation of surface, including writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high, stops commas, short lines, dashes, hyphens, brackets etc.for marking SM/MES No, Capacity etc. for the transformers, complete all as specified and directed.
Materials and Labour for applying one coat of synthetic enamel paint on old painted exposed steel surfaces of transformer 100 KVA to 160 KVA, 11/0.433 KV transformers in situ by spray painting, after preparation of surface, including writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high, stops commas, short lines, dashes, hyphens, brackets etc.for marking SM/MES No, Capacity etc. for the transformers, complete all as specified and directed.
Cutting of tree branch of girth exc. 20 cm but n.exc. 30 cm for clearing obstruction upto 3.00 metres from HT overhead lines throughout the route including cleaning away grass, vegetation saplings, shrubs, brush wood, around poles and stay assembly and including removing rubbish up to a distance of 50 meters out side the periphery of the area under clearance, complete all as specified and directed.
Repairs to battery charger with automatic float/boost change over suitable for charging of 110 Volts Battery Bank comprising of 55 Nos of 2 Volts,120 AH VRLA Type Batteries by removing from existing position,dismanteling of parts,periodic maintenance servicing of battery charger, replacement of DC battery card, FCBC system,contactors,relays etc. including replacement of all internal wirings and control wirings as per OEM's specifications,re-fixing in original position,testing and commissioning, complete all as specified and directed. OEM:- Amara Raja Power System, Sl No.- CON/00206/05-06, MES No.- NYA Note:- The work shall be carried out through Authorised & Qualified agencies as approved by the Engineer in Charge.
M&L for Servicing / Greasing of HT Switch air break ( GOD) 33 KV, TP horizontaly operated with replacement of Corroded nut Bolts, Male Female contact blade, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including complete greasing all as directed by Engr-in-Charge.
M&L for Servicing / Greasing of HT Switch air break ( GOD) 11 KV, TP Vertical / horizontal operated with replacement of Corroded nut Bolts, Male Female contact blade, ACSR Jumpers, making alignment of operating Mechanism for Proper ON / OFF operation of GOD and male contact including complete greasing all as directed by Engr-in-Charge.
Supply and Fix in repairs,switches air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 Amp, 11000 Volts Grade,complete all as specified and directed.
Supply and Fix in repairs,switches air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 Amp, 11000 Volts Grade, complete all as specified and directed.
Supply and Fix in repairs,drop out fuse (DO Fuse),11000 Volts grade with mounting channel,post insulator caps,DO Fuse barrel holder,fiber glass tube DO fuse barrel with heavily tinned non ferrous metal parts at both the ends,DO fuse hook, brush type phosphorous bronze DO female contact, DO female contact holder,flexible copper wire,02(Two) Nos 11KV porcelain post insulators,complete all as specified and directed. [Cat No. REE-DO-01-11 of Make ‘Rashtriya’ or equivalent Model of Make ‘Jaipuria/BHEL]
Supply and Fix in repairs, lightning arresters metal oxide type,consisting of a stack of zinc oxide discs encapsulated in heat shrinkable sleeve,arranged in hermatically sealed porcelain housing,complete with all fittings,distribution class,discharge capacity 65 kilo amp,suitable for 11000 Volts complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Two Pole Structure up to PCC base including cross arms, bracings,clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Three Pole Structure up to PCC base including cross arms, bracings, clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Four Pole Structure up to PCC base including cross arms,bracings,clamps etc.,complete all as specified and directed.
Material and Labour for complete removal of existing painting,preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on prepared surfaces of steel tubular swaged poles, type 410 SP-55 (11.00 Metres Long) in HT Twenty Four Pole Structure up to PCC base including cross arms,bracings,clamps etc., complete all as specified and directed.
Material and Labour for preparation of surfaces and applying one coat of aluminium paint on old painted surfaces of steel tubular swaged poles, type 410 SP-22 (8.50 Metres Long) including cross arms, bracings, clamps etc. up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with one coat of synthetic enamel paint black & yellow colour above PCC base up to 1.5M height and numbering of poles with letters and figures of height 75 mm at a height 2.60 metre from ground level,complete all as specified and directed.
Dismantling of ACSR conductors, line seperator, service feeder or distribution span from the existing LT&HT over head lines etc. complete all as specified and directed
Dismantling & taking down cross arms or MS channel or angle section etc from the existing LT ,HT Line & Transformer etc and setting aside for reuse or remove complete all as specified and directed
Dismantling & taking down insulators any type and size from the existing LT & HT line complete all as specified and directed
Materials and Labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel section including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of Aluminium paint over a coat of red-oxide, zinc chrome primer complete all as specified and directed.
Materials and Labour for drawing aluminium conductor,steel reinforced of any description including fixing of copper binding wire or aluminium tapes and including jointing, provision of jumpers etc complete all as specified and directed.
Supply and Fix, composite polymer disc insulator,11 KV,creepage distance 340 mm,cantilever strength 70/90 kN,conforming to IEC: 61109,complete all as specified and directed. [Cat No. REE-PL-01-24F-11 of Make ‘Rashtriya’ or equivalent Model of Make ‘Jaipuria/BHEL/Supreme’]
Supply and Fix,pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150 mm dia for 11000 volts grade,complete all as specified and directed.
Detecting carefully the fault location of HT UG cable of any size either HT cable fault locator machine or any other method and taking out the / remove the faulty portion of cable from undergound /duct including relaying with old cable cover, meggering / connecting / testing after repair complete all as specified and directed by Engr-in charge. Note:- (i) Excavation & earth work shall be measured and paid separately. (ii) Stright throught joint for HT cable shall be measured and paid seperatly under respective item of this schedule. (iii) Actual detected fault shall be paid under this item, Dummy located trail will not allowed or measured.
Taking out old HT cable from duct/trench of any size of cable as per dierected by Engr-in-charge.(Note Earth work shall be measured and paid seprately)
Material and labour including testing XLPE insulated screened , PVC bedded , galvanised steel strip or wire armoured , electric power cables (heavy duty) with aluminium conductor, 11000 Volts (Earthed), grade cross sectional area 95 Sqmm 3 core complete all as specified and directed.Make Polycab/Mescab/Crystal/Havells
Material and labour including testing XLPE insulated screened , PVC bedded , galvanised steel strip or wire armoured , electric power cables (heavy duty) with aluminium conductor, 11000 Volts (Earthed), grade cross sectional area 185 Sqmm 3 core complete all as specified and directed.Make Polycab/Mescab/Crystal/Havells
Excavation in trenches,not exceeding 1.5 m wide and not exceeding 1.5 M depth for foundation etc or for shafts wells, cesspits, manholes pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils. ( Note : The top of filled trench shall be made proud by using the complete excavated soil to cater for subsequent settlement of soil)
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
Supplying and laying un-reinforced precast concrete cable cover but class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified and directed
Re-laying/ Re-fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 11000 Volt Grade, Nominal Cross-Sectional Area 95 Sqmm 3 core to 185 sqmm 3 core, complete all as specified and as directed.
Re-laying of Old precast concrete cable cover of any size, complete all as specified and directed.
S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.Make : JINDAL/BANSAL/NTL.
Disconnecting and cutting down the existing unserviceable /burnt out HT cable straight through joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable straight through joints of 120 Sqmm to 185 sqmm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm to 185 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable indoor type joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable indoor type joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable outdoor type joints of 50 Sqmm to 95 sqmm 3 core, supply and jointing HT cable outdoor type joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 50 Sqmm to 95 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable indoor joints of 120 Sqmm to 185 sqmm 3 core, supply and jointing indoor type through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm to 185 sqmm 3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M.
S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof/Pole conductors and down conductors above ground for fixing of lighting arresters including taking down of existing, complete all as specified and directed.
S&F Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof/pole conductors and down conductors above ground and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length including taking down of existing, complete all as specified and directed.
All as per item No 90 but copper strip size 32 X 6 mm.
Demolition old damaged Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description, (in any position) and removing the same from site(s), complete all as specified and as directed.
M&L for Cement Concrete 1:2:4 (12.5mm graded Stone Aggregate) as in Kerbs, Coping, etc. Chamfered Edges including Formwork if required, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 METRE mean Radius, built in Cement Mortar (1:6), complete all as specified and as directed.
M&L for Peas gravels 20mm to 63 mm size, spreading the same all as directed by Engr-in-Charge.
kabitaconstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .