Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
PROVISIONING OF HARD STANDING BETWEEN ROAD AND RAMP OF MAGAZINES, PROVN OF AS AND AS TO MAIN GATE OF NAD BHEEMUNIPATNAM, AS AND AS TO BLDG NO. P-172 NEW ADMIN BLOCK INS KALINGA BHEEMUNIPATNAM, PROVN OF UPPER BODY WORK UP STATION AT INS KARNA UNDER NA
2021_MES_424970_1
GE (P)/N/K/8791 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a(I)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹76,800
Yes
17 May 2021
23 Feb 2021
25 Mar 2021
23 Feb 2021
23 Mar 2021
10 Mar 2021
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles portions complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using soft/loose soil obtained from excavation. complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated soil to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Rolling and consolidation of formation surface with power roller 8 to 12 tonne capacity complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated soil to a distance exc.500m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L 150 mm thick (spread thickness ) soling or sub base with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber. complete all as specified and as directed by the Engineer-in-Charge.
M&L 150 mm thick (consolidated thickness ) WBM (in two layers of 75 mm thick ) with granite, trap or basalt stone coarse aggregates of grading 2 (63mm to 40 mm size)or of grading 3 (50mm to 20mm size)spread, rolled and consolidated to required gradient and camber. complete all as specified and as directed by the Engineer-in-Charge.
M&L for sand filling under floors/pavement or in foundations including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
M&L for Rubber moulded, machine pressed, precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness,M-40 grade with gray cement complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) each area exc 1.50 sqm but n,exc 4 sqm each complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for precast PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) in kerb stones, window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and set in cement mortar 1:4 complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
M & L for Cement concrete of type C1, 1:3:6 of (20 mm aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of form work to sides of foundation/footings, plinth beams and similar work for rough finished surfaces complete all as specified and directed.
M&L for anodised powder coated aluminium frame for doors, windows, ventilators partitions with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F anodised powder coated aluminium door shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
M&L well seasoned Second class HW scantlings clean sawn in framed and fixed work complete all as specified.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in skirting/vertical and jointed in set stair raising platforms and like in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre size of grid 605 x 605mm complete all as specified and as directed
M&L for Gypsum boards 12mm thick in false ceiling concealed type fixed with screws in GI frame work catered under item No.29 above fixed with anchor fasteners and applying two coats of oil bound distemper over one coat of 2mm thick putty as per manufacturers instructions complete all as specified and directed by the Engineer-in-Charge.
S&F Anchor fastening 10 to 12mm dia. mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5cm n.exc 10cm long complete all as specified and directed by the Engineer-in-Charge.
M&L for cleaning of all laitance, algae, grease etc on existing concrete surface by grinding, wire brushing or sand blasting and laying Non skid/matt finish coloured ceramic tiles 7 to 8mm thick of size exc 0.11 Sqm but not exc 0.36 sqm in floor, set and jointed in 'NITOTILE MPA' of M/s FOSROC or' Modern tile adhesive' of M/s Dr Fixit or 'BASF' adhesive tile' of M/s BASF or equivalent make tile adhesive and pointed with 'NITOTILE GROUT' of M/s FOSROC or Dr Fixit Fevimate of M/s Dr Fixit or 'TILE GROUT' of M/s Asian Paints or equivalent make all as specified and as directed by engineer-in-Charge.
M&L for taking down existing cement plastering and providing Non skid/matt finish coloured ceramic tiles 7 to 8mm thick of size exc 0.11 Sqm but not exc 0.36 sqm in skirting/vertical surfaces set and jointed in 'NITOTILE MPA' of M/s FOSROC or modern tile adhesive of M/s Dr Fixit or 'BASF adhesive tile' of M/s BASF or equivalent make tile adhesive and pointed with 'NITOTILE GROUT' of M/s FOSROC or Dr Fixit Fevimate of M/s Dr Fixit or 'TILE GROUT' of M/s Asian Paints or equivalent make over 10mm thick backing coat of cement mortor (1:4) using integral water proofing compound all as specified and as directed by engineer-in-charge.
S&F Polycarbonate corrugated sheet 2mm thick of any colour as in roof covering/cladding to wall, fixed with self tapping screws as specified
Forming morticle holes exc 50 cu cm but not exc 1000 cu cm for balusters, newels, posts etc and grouting with cement mortar (1;2) after fixing.
M & L for Prelaminated particle board 18/19mm thick ,prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work.
M & L for fixed in repairs 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
M&L for rendering 10mm thick with CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 10mm thick with CM 1:6 on internal surfaces of brick work or concrete surfaces, complete all as specified and as directed by the Engineer-in-Charge.
S&F Stainless steel handrails, fabricated to required design, using 304L stainless steel pipe of 50mm dia welded to 25mm dia stainless steel pipe balusters @ 300mm centre to centre and fittings, including welding and polishing and fixed with necessary stainless steel plates, flanges, canopies, screws etc, complete all as specified and as directed.
M&L 15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 complete all as specified.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
Dismantling of wall and ceiling boards (fiber, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets and removing materials from site of work complete all as directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of plastic emulsion over a coat of primer including 3mm thick wall care putty complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over one coat of primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of existing treatment on walls and applying two coats of weather proof exterior emulsion paint over one coat of primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over one coat of primer on walls including 2 mm thick wall care putty complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of the existing treatment on the wall surfaces and applying two coats of weather proof exterior emulsion over one coat of primer including applying 3 mm thick exterior wall care putty complete all as specified and as directed by the Engineer-in-Charge.
M&L 12mm thick frameless toughened glass door with sliding shutters (02 nos), factory toughened plain sheet glass, not exceeding 2.00 sqm, using stainless steel fittings of polished chrome finish in each shutter(satin stainless steel finish for handles) including cutting necessary holes and cut-outs complete all as specified and as directed. (a) corner lock patches with EPC and strike plate XL-C-4011A:01 No (for openable shutter) (b) Floor spring 90o open (EN4) 01 No (for openable shutter) (c) Top patches XL-C 4012: 01 No (for openable shutter) (d) Bottom patches XL-C 4013: 01 No (for openable shutter) (e) Top pivots XL-C 4014: 01 No (for openable shutter) (f) 450 mm long H-Type handles 25mm dia of grade SS-304, XL-C-3003A: 01 No (01 Set for openable shutter)
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 including painted one shop coat of zinc chromate prime paint including preparation of surfaces complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F 5.5mm thick plain sheet glass, ordinary quality and glazing with oil putty in square n. exc. 0.5 Sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F 12mm thick toughened glass with stainless steel (Grade 304L) studs and bolts on all edges as per site requirements with standard make all as specified and as directed
S&F aluminium extruded section door closer hydraulically regulated, designation No.3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 36 to 60 kg complete all as specified and as directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out hard/ dense soil complete all as specified and as directed by the Engineer-in-Charge.
M & L Reinforced Cement Concrete type A-1, 1:1 1/2:3 (20mm graded granite stone agg) as in foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar works, vertical or to batter complete all as specified and as directed.
All as per Srl item No. 53 here-in-above but for columns and pillars complete all as specified and as directed.
M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete etc finished rough surfaces of concrete complete all as specified.
M&L TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including crancking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and as directed.
M&L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required including cranking bending hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
S&F single stanchions built up of one MS tube conforming to IS 1169-1979 grade Yst 240 with flange plates, caps, bases, splices angle brackets, cleats and other connected items complete all as specified.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 including gusset plate, including erection of vertical supports for holding purlins, rafters, base plates, nuts & bolts etc. complete all as specified and as directed.
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality-A complete all as specified and as directed by the Engineer-in-Charge.
S & F 16 to 20mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and secured the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts exc 5 cm and n.exc 10 cm long complete all as directed
S & F 16 to 20mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and secured the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts exc 12 cm and n.exc 20 cm long complete all as directed
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
Material and labour for point wiring for one light controlled by one 05 amp one way modular switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly complete all as specified and as directed.
All as per Srl Item No. 64 here-in-above but for One Exhaust/ fan point controlled by one, one way switch 5 Amp and regulator
All as per Srl Item No. 64 here-in-above but for One socket outlet point 3 pin 5 A on independent board.
All as per Item No. 64 here-in-before but for one15Amp 3&5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
All as per item no-64 above but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
All as per Srl Item No. 64 here-in-above but for One switch socket outlet point 5 A on same board with other switches
All as per Srl Item No. 64 here-in-above but for One single pole two way point controlled by one two way switch on the other switches or independent all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends and making good disturbed surface complete all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn existing surface /recessed and including PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete with taking down old unserviceable submain wiring complete all as specified and as directed.
M&L for concealed Sub main wiring with two run of 4.00 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including PVC medium grade conduit of 25 mm dia with all fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 4.00 Sqmm as earth continuity conductor connected to common earth and earth dolly for main DB to sub DB including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends with taking down old unserviceable sub main wiring and making good the disturbed surfaces complete all as specified and as directed. NOTE: 3 runs of 4 Sqmm and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM
S & F modular plate switch flush type single pole one way 6 Amp, 250 volt , complete all as specified and as directed.
S & F Switch modular flush type single pole two way 5 Amp, 250 volt , complete all as specified and as directed.
S & F modular plate switch flush type single pole one way 16 Amp, 250 volt , complete all as specified and as directed.
M&L modular socket 6 Amps 5 pin complete all as specified and as directed.
M&L modular socket 6-16 Amps 2/ 3 pin combined shutter complete all as specified and as directed.
S&F modular step type fan regulator 120 watt two module five steps and back plate complete all as specified and as directed.
S&F modular plate white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules complete all as specified and as directed.
All as per Srl Item No. 80 here-in-above but for 6 modules
All as per Srl Item No. 80 here-in-above but for 3 modules
All as per Srl Item No. 80 here-in-above but for 2 modules
S&F flush metal box 1/2 module complete all as specified and as directed.
All as per Srl Item No. 84 here-in-above but for 6 modules
All as per Srl Item No. 84 here-in-above but for 3 modules
All as per Srl Item No. 84 here-in-above but for 8 modules
S&F water proof modular socket 1x3 P+1L1W IP 55 230 volts all as specified and as directed.
S&F modular AC Starter single pole 32 Amps 230 volts all as specified and as directed.
S&F indicator lamp modular type single pole 32 Amps 230 volts all as specified and as directed.
S&F 4 module LED foot light modular type single pole 230 volts all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 65 x 30 mm three terminals all as specified and as directed.
S&F bell ding dong 5 Amps, flush type, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
S&F modular plate bell push flush type, single pole one way 6 Amps, 230 Volts, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar , all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar , all as specified and as directed.
Supply and fixing sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts , all as specified and as directed .
Supply and fixing in proper position MCCB four pole of capacity 100 amps, 415 Volts 25kA breaking capacity, all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 32 amps, 415 Volts in proper position, all as specified and as directed.
S&F single pole and neutral enclosure with two pin earth plug and socket complete with 01 double pole MCB 20 Amps 240 volts complete all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position, all as specified and as directed.
Supply and fixing in proper position MCB double pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity, all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. [Make:CG Cat Part no.CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE]
Supply and fixing 7.5 W LED decorative wall/surface mounting cognac hammered glass, all as specified and as directed. (Make: Havells Cat Part No. LHFXAHPITNIA007 or equivalent as approved by GE)
S&F LED mirror light fittings 07 watt, 230 volt, 50 Hz suitable for indoor and outdoor applications complete all as specified and as directed.
S&F Recess Mounting luminaries LED down lighter of24 W, white in the shape of square 1' x 1' complete all as specified and as directed (Make:CG cat No.-CDR209-18-30-SL-NWH or equivalent as approved by GE)
S&F water heater (Geyser) storage capacity 25 ltrs vertical type 5 star rated along with electric wiring 04 Nos GI Anchor bolts 12mm dia, 100mm long nuts and washer complete all as specified and as directed.
Supply and fixing AC single phase static Electronic KWH energy meter of accuracy class 1.0,240v,50Hz, with bakelite LCD Display, of rating 10-60A with transparent hinged type Box with six month History of energy in KWH meter all as specified and as directed by the Engineer-in-Charge. (Make: HPL Cat Part No. SPPLI5200100002OC00 or equivalent as approved by GE)
S&F ceiling fan 1200mm sweep, BEE 5 star rated 380 Rpm with high air delivery at low voltages, with double ball bearing in ivory gold/white colour including fixing of regulator, down rod of 19mm dia 300mm long and connecting up with flexible 3 core 1.5sq.mm twisted copper cable from terminal point to ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixed in repairs LED well glass fitting pressure die cast aluminium housing with heat resistant toughened glass & IP protection luminaries of capacity 35 watt etc all as specified and as directed by the Engineer-in-charge. (Make: Crompton Cat Part No. LWV12-35-CDL-HP OR equivalent as approved by GE)
S&F Exhaust fan wall mount type 300 mm sweep metal body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F exhaust fan 300 mm sweep PVC body, 230 Volts single phase AC with louver shutter/ grill including 3 core copper cable from ceiling rose to exhaust fan & required hold fast, cutting holes on walls of suitable size complete all as specified and as directed. (Make : Havells Cat No. Ventil Air-DX white or equivalent as approved by GE)
S&F wall mounted Air circulators fans PVC body 400 mm sweep 230 volts SP complete with accessories all as specified and as directed.
Material and labour for galvanized iron tubing 25 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor including necessary clamp, bolt/nut if any all as specified and as directed.
M&L for earthing complete with 7.5m long CI pipe 80mm dia. with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 7.5m length buried directly and preferably vertically in ground with top flanged ended 7m below ground level welded/ connected with GI strip 32x6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400mm dia. bore in any strata of soil to lower the CI pipe complete all as specified and as directed by the Engineer-in-Charge. Note: The rate deemed to be included the earth pit chamber, CI cover and earth lead 32x6mm GI strip from earth pit to DB upto 7 mtrs. length and testing on completion.
NIKESH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .