Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹1.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.4 Cr+₹10.0 L (7.76%)Rejected-AOC | ₹1.4 Cr+₹10.0 L (7.76%) | L2 | Rejected-AOC AOC |
| 3 | Rejected-Technical | - | - | Rejected-Technical Due to non-enlistment in eligible category and non-submission of requisite experience. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to non-submission of requisite experience. |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
15 May 2023, 6:00 pmClosed
CWE (AF) Borjhar
HQ CWE (AF) Borjhar, Military Engineer Services, PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
WORK SERVICES FOR MLH UPGRADATION INFRASTRUCTURE AT AFS KUMBHIRGRAM (2nd CALL)
2023_MES_583016_2
CWE(AF)/KUM/TOKEN-46 OF 2022-23
Open Tender
Civil Works - Canal
Item Rate
365 days
Kumbhirgram
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE (I) (AF) Kumbhirgram
₹2.1 L
Yes
28 Jun 2023
13 Apr 2023
22 May 2023
13 Apr 2023
15 May 2023
21 Apr 2023
Amount
SCHEDULE 'A' PART-I (B/R PORTION)
B&R SERVICES: Demolition of plain cement concrete (Un-reinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 25 mm thick plain cement concrete (1:2:4) type B0 using 12.5 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
S&F for glazed ceramic coloured/printed tiles of size(350x250)/(450x350) x 6 to 7 mm thick as in vertical surfaces such as skirting, dados over and including 10 mm thick screed in cement mortar (1: 4) complete all as specified and directed.
M&L for non skid ceramic joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
S&F 10mm thick vitrified ceramic tiles light shade coloured (Square or rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper on wall over one coat of cement primer including preparation of newly plastered surfaces complete all as specified and directed .
M&L for preparation of old decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying two coats of oil emulsion distemper over a coat of cement primer complete all as specified and directed.
Complete removal of existing treatment of walls, external fins, fascia, vertical and horizontal surface of roof projection, chajja etc; including brooming down, and applying two coats of weather proof anti fungal exterior emulsion paint (Smooth classic) over a coat of primer on old plastered surfaces with nesessary scafolding complete all as specified and directed.
M&L for preparation of new plastered surface of wall, fins, fascia, vertical and horizontal surface of roof projection, chajja and applying two coats of weather proof anti fungal exterior emulsion paint (Smooth classic) over a coat of primer ,including nesessary scafolding complete all as specified and directed.
M&L for preparation of newely plastered surface of ceiling and applying three coats of white wash , complete all as specified and directed.
S&F GI tubing 15 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc. and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F GI tubing 20 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc. and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Taking down existing roof treatment such as tarfelt with tiles and cement /lime mortar and screed bed from roof surfaces including parapets and lowering and removing the same to a distance exc. 50 m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound as per manufacturer's instructions, finished even and smooth on exposed concrete surface without using extra cement complete all as specified and directed. (Note: Water proofing compound shall be measured and paid separately under relevant item as supply only).
M&L for 15 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement including mixing of WPC as per manufacturer's instruction complete all as specified and directed. (NOTE : Polymeric membrane and WPC shall be measured and paid separately under relevant item ).
Supply only integral water proofing compound conforming to IS:2645-1975, complete all as specified and directed.
M&L for water proofing treatment with APP based polymeric membrane comprising with the following courses of treatment/ specification from bottom to top complete all as specified and directed:- (a) Applying bitumenous primer @ 0.25 ltrs/ sqm over plastered surfaces of roof including parapet surfaces. (Note :- Bituminuous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd./STP) (b) Over the priming coat 3mm thick APP based polymeric membrane weighing not less than 3.50Kg/Sqm reinforced with polyster non woven fabric weight not less than 160 gms/sqm. Membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based polymeric membrane shall be done thermo fused by flame torch all as per the method of manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm shall be given at the end and sides of the membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (c) Applying two coats of aluminium paint over APP membrane @ 100 gms /sqm. Make of APP membrane:-Dr Fixit manufactured by M/S Pidilite Industries/ MOPLY FP 3MM manufactured by M/S Texsa India Limited/ Hyperplus by IWL India Ltd.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan to any radius built in cement mortar (1:4) as in half brick thick wall complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
S&F anodised aluminium frame for partition, doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and as directed.
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays, hinges , suitable handle complete all as specified and directed.
M&L for anodized aluminium push pull type partly paneled and partly glazed door shutter having top rail of section 85.00mmx44.45mmx2.00mm, bottom rail of section 85.00mmx44.45mmx2.00mm thick, door verticals of section 44.45mmx44.45mmx2.00mm thick and lock rail of section 85.00mmx44.45mmx2.00mm thick with aluminium anodized chowkats of section 63.50mmx33.10mmx2.50mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle and brass mortice lock 4 lever etc. fitted with 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel complete all as specified and as directed.
S&F PVC insulation panels 10mm with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of aluminium/ GI/ MS as per specification and manufacturers instruction complete all as specified and directed.
S&F 5.5mm thick tinted sheet glass, ordinary quality in square/ rectangular exceeding 0.50sqm in each pane complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laoratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F in repair overhead shower 125mm dia round shape single flow (ABS body chrome plated with gray face plate) with rubit cleaning system complete all as specified and directed. Make :ESSCO model EOS-542A or equivalent model of make Parryware/ CERA/ Hindware/ Prayag.
S&F in repairs bib taps 15 mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
M&L for TMT bars 10 mm dia & over, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed.
M&L for RCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in precast cover slab etc., set in cement mortar 1:4 complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished), bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as specified and directed.
M&L for anti static conductive flooring, 2mm thick colour conductive ESD tiles as per EN 649, one coat of conductive undercoat, copper net with conductive adhesive, 2mm thick epoxy screed and primer after surface preparation by cleaning surface from dust, roughening of concrete surface, dirt, muck, moisture and all foreign material and cleaned by mechanically using mechanical scrubber/grinder, chemical treatment for cleaning of oil, grease if required. Any patch of area needs to be repairing shall be repaired with instant concrete repair compound consisting of specially developed EPU resin and hardener and application as per manufacturer's instructions. Make: POLAM/FORBO/FOSROC /Cipy or equivalent make as approved by AGE(I). Note :(i)Work shall be carried out by authorised applicator of the manufacturer under manufacturer's supervision. (ii) Testing of all the anti static conductive flooring items shall be done as per IS/ASTM before incorporation of materials in the work.
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as in sub base of floor complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, complete all as specified and directed.
M&L for PCC (1:2:4) Type B1, (using 20 mm graded crushed stone aggregate) as in kerbs, coping, benching on top of drain and like including necessary moulds and form work complete all as specified and directed.
Demolition of brick/stone massonry work built in cement mortar as in wall including all quoins, arches, pillars etc complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as specified and directed.
S&F interlocking aluminium power coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and directed.
M&L for Non Asbestos fibre cement building boards 4 mm thick fixed or laid in aluminium frame work with screws as in ceiling complete all as specified and directed.
INTERNAL ELECTRIFICATION Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, complete all as directed.
Materials and labour for concealed point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, drawn through and including PVC conduit 20 mm dia(medium grade) complete with all fittings and accessories, fixed to walls/ceiling, including factory made sunk type mild steel terminal boxes 1.25 mm thick (wall thickness) conforming to IS-5133 (Part-I) suitable for mounting modular cover , base plate with modular switches/ sockets/regulator etc., 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one switch including cutting chases for concealed conduit pinning in making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
All as per item No 48 here-in before but for one 3 pin, 5 Amp socket point on independent board complete all as specified and directed.
All as per item No 48 here-in before but for one 3/5 pin, 16 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor with 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable for earth continuity conductor complete all as specified and directed.
All as per item No 48 here-in before but for one 3/5 pin, 20 Amp switch socket combination on independent board with 4.0 sqmm PVC insulated unsheathed multistranded FRLS copper conductor with 2.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable for earth continuity conductor complete all as specified and directed.
S&F modular switch one way 6 amps, 1 module complete all as specified and directed.
S&F modular switch one way 16 amps, 1 module complete all as specified and directed.
S&F modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed.
S&F modular socket, 6A/16A-2/3 pin combined, 2 module complete all as specified and directed.
S&F modular fan step regulator, 120W, 2 module complete all as specified and directed.
S&F modular wite cover plate with frame , 3 module complete all as specified and directed.
S&F modular wite cover plate with frame , 6 module complete all as specified and directed.
S&F modular wite cover plate with frame , 8 module complete all as specified and directed.
S&F sheet metal single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20Amps, 10KA complete all as specified and directed.
S&F high performance metal body exhaust fan 300 mm sweep, 1400 RPM 230 volts AC 50 Hz, heavy duty with suitable size MS sheet louver including connecting up to ceiling rose by three core sheathed copper conductor cable of suitable size including making hole of proper size and make good the disturbed surface both inner and outer side of wall complete all as specified and directed.
S&F thunderstrom wall fan 450 mm sweep, single phase, 230 volts AC 50 Hz, including connecting up to ceiling rose by three core sheathed copper conductor cable of suitable size complete all as specified and directed. Make :ORIENT or equivalent of USHA/BAJAJ as approved.
S&F ceiling rose, surface bakelite 65 x50 mm three terminals, complete all as specified & directed.
S&F LED batten tube light fittings , 18 W with high quality extruded aluminium housing & integrated LED driver with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F recessed mounted LED luminaire 36 W (2'x2') suitable for grid ceiling with white powder coated CRCA housing & super bright LEDs, seamless front frame with flat white high transmission acrylic cover with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
M&L for sub main wiring with 2 runs (Phase Neutral) of single core 6.0 sqmm (Nominal area) stranded FR PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit not less than 20 mm size including 1 x 6.0 sqmm (Nominal area) FR PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length. (ii) Cutting chasing and make good for concealed conduit shall be measured and paid seperately.
M&L for sub main wiring with 4 runs (Phase Neutral) of single core 10.0 sqmm (Nominal area) stranded FR PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit not less than 25 mm size including 1 x 10.0 sqmm (Nominal area) FR PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: (i) Four runs of 10.0 sqmm cable and one run of 6.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length. (ii) Cutting chasing and make good for concealed conduit shall be measured and paid seperately.
Cutting chases brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring etc., cutting not exc 10cm girth complete all as specified and directed.
S&F MCB DB , TPN 4 way, double door including earth and neutral link ,complete with fixing accessories all as specified and directed.
S&F MCB DB , SPN 8 way, double door including earth and neutral link ,complete with fixing accessories all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as directed.
S&F MCB DP, 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps complete all as directed.
S&F MCB TPN, 415 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps complete all as directed.
AC & REFRIGERATION: Supply and install Inverter series hi wall split type AC (indoor & outdoor unit) with cordless remote control unit with 5 star rating and EER 3.2 of capacity 1.5 Ton connection with 16A plug top to existing socket point complete all as specified and directed. Note. Cost and provision of making holes for necessary connections through the walls, PVC pipe 15 mm bore dia for draining out condensate water, copper tube with insulated material for complete Job and factory made MS bracket and Plumbing and masonry work if any required deemed to be included in unit quoted rates.
Supply and fix voltage stabilizer automatic operated single phase naturally air cooled indoor type & designed for input variation between 150 V to 290 V with output voltage stabilized at 230 V with accuracy of +/-2.5% and suitable for 1.5 Ton AC complete all as specified and directed.
S&F sheet metal single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 10 KA complete all as specified and directed.
M&L for sub main wiring with 2 runs (Phase Neutral) of single core 4.0 sqmm (Nominal area) stranded FR PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through and including concealed PVC conduit not less than 20 mm size including 1 x 4.0 sqmm (Nominal area) FR PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm earth continuity conductor including PVC conduit with plastic terminal boxes shall be measured as one run length. (ii) Cutting chasing and make good for concealed conduit shall be measured and paid seperately.
Cutting chases brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring etc., cutting not exc 10cm girth complete all as specified and directed.
FIRE FIGHTING Supply, install, testing and commissioning PA amplifier with digital player of under mention specifications :- (i) Power output - 250 watt max (ii) Signal of noise ratio - 55 DB (iii) AC 220-240 V 50/60 Hz DC 12-14 V with MP3 Player & USB Reader all as specified and directed
Supply, install, testing and commissioning intelligent addressable fire alarm control panel with original licensed software complying with EN 54 standard & LPCB approved and battery back up to one hours with the speicifications as appended below :- (a) Power - AC 230 v, 50 Hz, 0,5A. (b) 99 devices. (c) 99 detectors and minimum one loop. (d) Relay - Fire Alarm/F.P.E./Fault/Sounder. (e) Network - RS-485 interface (Max 32 Panels) & network card. (f) PC port -RS- 232 interface & communication card. (g) Printer panel & LCD display and inbuilt printer with battery back up of 24 hours in non alarm condition and 15 minutes in alarm condition (battery type 2 x 12 v 21 AH, sealed tupe all as directed by Engr-in-Charge
Supply, install, testing and commissioning electronically addressable intelligent combination of heat and photo electric smoke detector with mounting base complying with EN 54 standard and IS:11360 and LPCB approved with the specification as appended below :- (a) Power - 24 v, < 0.8 mA (standby current) < 5.0 mA (Alarm current). (b) Class A2R. (c) Indicator - red flashes in normal and illuminates in alarm. (d) Ingress Protection IP-22 & Material -ABS all as specified and as directed.
Supply, install, testing and commissioning electronically addressable intelligent Ultra Violet and infrared detector by analyzing ultra violet radiation of flame with mounting base complying with IS:2189 with specification as appended below :- (a) Power - 24 v, < 80 mA (standby current) < 150 mA (Alarm current). (b) Indicator - Normal - Flickering Green LED Fire-red LED. (c) Ingress Protection IP-66 & Material -Cast aluminium LM-6 all as specified and as directed.
Supply, install, testing and commissioning electronically addressable intelligent remote response indicator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below :- (a) Power - 24 v. (b) Material - ABS.
Supply, install, testing and commissioning electronically addressable intelligent sounder/ siren with mounting base, continuous normal operation for atleat 50 minute with sound level 65db - 120db measured at 1.5 mtr with sound output variation + 5db complying with the specification as appended below :- (a) Power - 12/24 v DC or 110/220 V AC, 1Ph,AC 50Hz. (b) Range - 1000 m.
M&L 2 core HR FR PVC insulated cable of 1.5 sqmm 1.1 KV grade in stove enameled steel conduit including bend, tee and other accessories of 25 mm dia on ceiling/wall/floor through galvanized steel clamp/ saddles and stainless steel screw/rowl plug for fire alarm system complete all as specified and directed.
M&L 3 core HR FR PVC insulated cable of 2.5 sqmm 1.1 KV grade in stove enameled steel conduit including bend, tee and other accessories of 25 mm dia on ceiling/wall/floor through galvanized steel clamp/ saddles and stainless steel screw/rowl plug for fire alarm system complete all as specified and directed.
Supply, Installation for design condition 22 ± 2 degree celcius and RH 50 ± 5 % of variable refrigerant flow / variable refrigerant volume (VRF/ VRV) modular type Air conditioning sysyem suitable for cooling and heating by both multiple scroll crompresser controlled by individual inverter complete with indoor and outdoor unit with individual wired and wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas & oil, internal control cabin and fitting and outdoor unit connecting kit etc as per details given inspecifications and having following items. The outdoor units shall be suitable for 3 phase 4 wire system, 415 V ± 10 %, 50 Hz AC supply and indoor shall be suitable for single phase 220 - 240 V, 50 Hz AC Supply, necessery lay out plan to be approved by Engineer in charge complete all as specified and directed. Outdoor units (ODUs) Design, Supply, Installation, Testing & Commissioning of approved make Air cooled type outdoor units (ODU) of variable refrigerant flow (VRF/ VRV) type air conditioning system of 22 HP (01 No) capacities, with DC Fully Inverter based Variable frequency drive & hermetically sealed scroll compressor working with R-410 A or equivalent refrigerant. The system shall be suitable to operate on 3 phase, 415 V (with ±10% variation), 50Hz (with ±3% variation) AC power supply & shall comprise of air cooled axial flow condenser fan (with upward throw) with motor, condenser coils with Aluminium fins, microprocessor control panel, starter controls for all scroll compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes for interconnecting various capacity modules (to meet desired HP rating of the ODU, if required), charging port and all other required accessories & hardware. Machines shall be commissioned by vacuumisation, nitrogen purging and supply of required quantity of refrigerant gas charging. The unit should also consist of inbuilt Internal Thermal protector, Internal Pressure Relief valve, High Pressure cut-out, Low pressure cut-out for compressor protection etc. The ODU should be capable of working with total capacity of connected indoor units without diversity of 100% Full capacity load of ODU capacity. The units shall also be protected against any variations in power supply (over/ under voltage, phase reversal, single phasing etc.) beyond acceptable levels (415 V ± 10%). The entire unit shall be with weather resistant powder coating paint for withstanding all ambient conditions for continuous outdoor operation. Make : Daikin/Hitachi/Voltas
Design, Supply, Installation, testing & Commissioning of following air cooled type 1 Way directional air flow Ductable type Indoor Air Conditioning Units of capacity 11. 0 Tr Ductable AC with wired remote suitable for mounting inside false ceiling, each comprising of cooling coil, blower with multi speed motor, electronic expansion valve, supply & return air grilles, filter, insulated connection of refrigerant circuit, provision for fresh air intake ducting, with electronic level sensor, including wired remote controller etc. All indoor units shall be of the same make & compatible to work with VRV / VRF type condensing unit and should include mounting brackets, supports and a corded remote. All hardware, including but not limited to anchor fasteners and threaded bolts etc complete all as specified and directed
Reff Net or Copper Connecting Kit from Same OEM make only for Indoor Units joints and Outdoor Units Joints complete all as specified and directed
Supply, Installation, testing and commissioning of the ASTM B 280 compliant heavy gauge insulated refrigerant piping for connecting all ODUs with corresponding IDUs (mentioned in item nos. (1) and (2) above of the VRF system as per specifications and layouts submitted by OEM and approved by Engineer In charge. The insulation shall be of appropriate thickness EPDM Nitrile rubber insulation in sleeve form, for gas and liquid sides, throughout the running length of the refrigerant piping complete all as specified and directed.
Supply and laying rigid UPVC drain piping of 25 mm dia (along with all accessories such as tees, bends, couplers etc.) with 9 mm thick black armoured Nitral insulation sleeve and PVC tape connecting drain outlets of all indoor units (using 25 mm branch line) to nearby drain points suspended from the ceiling using proper support complete all as specified and as directed.
Supply & fixing of control cum transmission wiring of Copper conductor 2.5 sqmm along with PVC conduit for looping between indoor & outdoor system & to main Central remote controller system complete all as specified and directed
Supply and fixing of GI perforated cable tray with supported by GI Channel complete.
Supply, Installation and Testing of factory fabricated GI sheet of size 22 SWG for rectangular ducts aswith necessary accessories and supports in accordance with the approved shop drawings and as required by the specifications. Galvanization shall be Class VII – light coating of zinc, nominal 120 gm / sqm surface area. The Duct shall be included with fasteners, threaded rods, nut, Gasket and washers as per specs and ducts supported.
Supply & fixing aluminium extruded with powder coated finish continious grilles of standard size 6 feet by 6 inch complete all as specified and directed.
Supply fixing and testing of flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings complete.
M& L for Leak testing , Nitrogen Flashing and Pressure Checking of complete system as directed
Supply and Charging of refrigerant gas in ODUs after completion of all installation and connection and the working pressure for a minimum 124 PSI for 24 hours for ensuring leakproof piping.
Supply and fix thermal dehumidifier continuous operating complete, with heaters, ducting, electrical connection for required cfm capacity for 11 ton VRF System to maintain RH 45-55% in indoor unit complete.
Supply, install, testing and commissioning of Isolation transformer of 50 KVA, 3 phase Primery 415 VAC, 50 Hz, Secondery 415 VAC (L-L), 50 Hz, Naturally oil cooled, indoor, balanced type, copper wound, metalic body duly powder coated with lifting Hooks two Nos, digital display type, relay free smooth and silent operation with 1st filling of Tranformer oil up to level having following specifications :- Rated Primery voltage : 415 VAC, 50 Hz + 3%, 3 Phase Rated Secondery voltage : 415 VAC at No load line to line Frequency : 50 Hz + 3% Voltage regulation : 4% max Percentage impedance : 4% with tolerance as per IS 11171: 1985/ IS 2026:1977 Insulation class : F Max, temperature rise : 90 Deg C above ambient temperature cooling : Natual Oil-cooled (AN) Dielectric voltage : 3 KV rms 50 Hz for one minute. (i) between primary and secondary Winding. (ii) between shorted windings and frame. Service condition : Altitude, reference ambient temperature wave shape of Supply voltage and symmetry of poly phase supply voltage. Note:- 1. The Transformer shall be tested as routine test as per IS 2026:1977 in presence of AGE(I)/his rep. 2. The contractor shall submit Quality Assurance Programe within 15 days after placement of order for testing of Transformer at factory. Transformer shall be dispatch only after inspection clearance by inspecting officer as detailed by Accepting Officer. 3. The contractor/manufacturer shall furnish original BILL certificate (paid vouchers and test certificate) of the CRGO manufacturer. 4. The contractor/ manufacturer shall furnish the diameter of LV & HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. The percentage of No load and Full load losses shall be as per IS 1180:2014 of Energy effieciency level 2. 5. The contractor shall get the approval of Accepting Officer for the make of the transformer. 6. Separate neutral bushing shall be brought out for earthing. 7. Necessery foundation shall be provided as per manufacturer's recommendation and quoted rate shall be deemed to be included accordingly. 8. Pre-commissioning test by EI/SEI will be carried out and all arrangement shall be done by the contractor at no extra cost.
EXTERNAL WATER SUPPLY S&F galvanized iron pipe, medium grade, 25 mm dia including all fittings laid in trenches, complete all as specified and directed.complete all as specified and directed.
S&F gun metal gate valve with iron wheel head, screwed both ends for iron pipe of size 25 mm dia, complete all as specified & directed.
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 Cm complete all as specified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Cutting of 25mm bore existing steel tubing including Screwing existing steel tubing for alterations or additions or lengthening screw on pipe to from new connector, complete all as directed. complete all as specified and as directed.
Supply, hoisting and fixed in position 500 liters Rotational moulded polyethlene water storage tank (cylinderical vertical with closed top) including ball valve high pressure with polythene float and flynut complete all as specified in SSR Part I and as directed.
EXTERNAL ELECTRIFICATION & DG SET Supply and laying XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 120 sqmm 3.5 core, connecting to LT panels, main switch with suitable size aluminium lugs, complete all as specified & directed.
Material and labour for disconnecting LT incoming and outgoing cables from existing LT panel and taking down the same from existing location (from wall) without any damage and refixing the same on backside of wall with necessary brick works and reconnecting all the incoming and outgoing cables with necessary cable joints and other allied works including making good disturbed wall surface all as specified and directed.
Supply, install, testing and commissioning of 100 KVA servo Voltage stabilizer (Confirming to BIS 9815: Part-I: 1994) for automatic operation three phase 50 HZ, naturally oil cooled, indoor, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks two Nos, digital display type, reply free smooth and silent operation with 1st filling of transformer oil up to level having following specifications :- (a) Input voltage 300V-480V. (b) Output voltage stabilizer at any design/ desired voltage 415 ± 2.5%. (c) Rated frequency 50 Hz. (d) No distortion in wave form. (e) Response time not to exceed 20 miles seconds. (f) Sensitivity +1%. (g) Rate of correction 8 Volts/ second for single phase and 13V/ second for phase to phase. (h) Efficiency more than 95%. (j) Type of load : Three phase, unbalances type. (k) Digital display voltmeter/ Ammeter. Protection :- (a) Over load/ Short circuit protections. (b) High/ Low voltage cut off. (c) By pass arrangement in case of emergency. (d) Single phase sequence change protection.
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth in hard/dense soil and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 Cm complete all as specified and directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Supply and spreading dry coarse sand in trenches as in sand cushioning for cable protection spread to uniform 23 cm thick and punch down gently to 18 cm after laying cable in trenches complete all as specified and directed. (Note: Compacted thickness shall be measured and paid)
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250mmx 150mmx 40mm laid dry and flat complete all as specified and directed.
Supply and laying 50 mm bore galvanized steel tubing, light grade, including all fittings in trenches, road/path or fixed to wall for cable protection, complete all as specified and directed.
Supply, installation, commissioning and testing of diesel engine driven generating set of capacity 40 KVA/32KW Turbo charged water cooled mounted on common base frame conforming to IS:10001/10002 and Alternator as per IS: 13364 with AMF Panel rated 415 volts 50 cycles, 0.8PF complete with relay panel for automatic starting on mains failure and accoustic enclousures as per relevant IS with control panel complete including the following :- A. ENGINE (a) Vertical 3 cylinder, cold starting in accordance with 1500 RPM including :- (i) Fuel filter (Pre & Micro). (ii) Fuel feed pump (on line mono block/PT tube) with governor. (iii) Lubne oil filter. (iv) Lubne oil cooler. (v) Drytype/ oil bath type air cleaner. (vi) Radiator, radiator fan & mounting. (vii) 12 volt electric starter B. ALTERNATOR Alternator, 3 Phase, 415 Volts, 50 Hz, 0.8 PF, 1500 RPM, self excited, self regulated, screen ptotected, drip proof alternator of capacity 40 KVA manufacture with insulation class 'H'. C. ACCESSORIES (i) Suitable channel frame with anti vibration pads. (ii) Storage battery of 12 Volts with suitable AH or as per manufacturers instruction and duly mounted on a MS stand made out of MS angle of size 40 x 40 x 6 mm. CONTROL PANEL The control panel shall be floor mounted type made of CRCA sheet duly fabricated with internal wirings, bus bar etc, and with the following accessories :- MCCB 4 Pole of suitable capacity, Control panel showing Voltage, Current, power factor, lub oil pressure, Fuel Level Indicator, KW, KVA etc. FUEL TANK (i) Fuel tank for suitable capacity for minimum 12 Hrs run. (ii) Fuel piping. NOTE (i) Anti vibration pads of suitable size shall be provided. (ii) Foundation/ platform of DG set to be made as per manufacturers instruction. Provision shall be made to drain out used lube oil during replacement. (iii) Exhaust pipe of engine is to be extended out of the building with suitable dia of MS pipe duly painted with anticorrosive paint and insulated with suitable dia asbestors rope duly claded with plaster of paris, the cost of the same shall deemed to be included in the unit rate of DG set. (iv) Lubricating oil shall be provided by the contractor during testing of engine. the cost for the same shall deemed to be included in the unit rate of DG set. (v) Emission of exhaust as per latest CPCB Norms II.
Supply and laying XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty underground electric cable aluminium conductor 1100 volt grade of cross sectional area 50 sqmm 3.5 core, connecting to LT panels, main switch with suitable size aluminium lugs, complete all as specified & directed.
M&L for PCC, 1:3:6, Type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC, 1:4:8, Type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Earthing complete with galvanized copper earth plate electrode 600cm x 600cmx 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level sorrounded from all sides by 15 cm thick layers of charcoal dust and common salt filling in alternate layers etc and connected to and including 20x 3 mm thick Copper strip upto 7.5 mtr by means of bolts, nut, check nuts and washer, made of galvanized iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 20 mm bore for watering and including funnel wire mesh and RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar @ 100mm c/c and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded stone aggregate) including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 metre and testing after completion all as speicified and shown in electrical plate No 3 of SSR Part-I 2009 complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level sourrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers etc and connected to and including 25 x 4 mm GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded aggregate) including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed.
M/s Nice Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .