| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.9 L+₹85,043.60 (5.65%)Rejected-AOC C O GIVEN GOD NONGTDAU ARBUTHNOT ROAD NONGRIMMAW LAITUMKHRAH SHILLONG PIN 793011 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793011 | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.0 L+₹98,157.60 (6.52%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹17.4 L+₹2.4 L (15.8%)Rejected-AOC C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
24 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
MISC BR REPAIR IN CERTAIN BUILDINGS OF DOMESTIC AREA AT AFS KUMBHIRGRAM
2021_MES_416705_1
CWE (AF)/KUM/TOKEN-47 OF 2020-21
Open Tender
Construction Works
Item Rate
180 days
Kumbhirgram
As per tender document
8 documents required · 8 mandatory
₹500
AGE I AF Kumbhirgram
₹36,000
Yes
5 Apr 2021
28 Jan 2021
26 Feb 2021
28 Jan 2021
24 Feb 2021
10 Feb 2021
60 days
Amount
Taking down chowkats or frames exceeding 1.5 SQM but not exceeding 4 SQM each (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) not exceeding 1.50 Sq.m each complete all as specified and directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick/stone massonry work built in cement mortar as in wall including all quoins, arches, pillars etc complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge/thickness in roof or wall covering complete all as specified and directed.
Demolition of cement concrete (unreinforcement ) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
Dismantling of unframed timber fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section complete all as specified and directed.
Dismantling unframed timber scantling 40Sqcm and over in section in any position complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed trusses etc. complete all as specified and directed.
Half brick thick wall with old size, sub class ‘B’ bricks (locally available best quality) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed.
Brick work with old size, sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
All as per item No 15 above but except bricks (using old serviceable bricks obtained form demolition after cleaning).
Supply and fix in repair factory made PVC kitchen cabinet frame of size 75mm x 40mm with wall thickness of 5mm, made out of extruded 5mm thick plain/prelam PVC sheet of density 600Kg/cum, reinforced with 15mm x 15mm MS Square tubes of 19 gauge thickness throughout the frame and miter cut at two corners and jointed with 2 Nos of 15mm long brackets of 10mm x 10mm MS Square tubes. The door frame shall be fixed to the wall using 65/100 long brass screw though the frame by using PVC fasteners, minimum of 4 Nos of brass screw to be provided for each vertical member and minimum of 2 Nos of brass screw to be provide horizontal member etc. complete all as specified and as directed.
Supply and fix in repair PVC Kitchen cabinet Shelves/Partition of required size consisting of 18mm thick PVC Ply panel and for supporting the shelf/Partition and shall provided 3 edges of size 18mm x 18mm as per required length. The front side of the edge visible in the front of the shelf/Partition to be lipped by 18mm width x 1mm thick sheet of density 600kg/Cum , fixed with using solvent cement and brass screw etc. complete all as specified and as directed.
Supply and fix in repair PVC Kitchen Cabinet Shutter of 30mm thick consisting of frame made out of MS Tubes of 19 gauge thickness and size 19mmX19mm covered with 5mm thick PVC 'C' channel of size 30mm x 50mm forming stiles, top and bottom rails. Paneling of 5mm thick plain/prelam PVC Sheets of density 600 to 700Kg/cum density, fitted in the M.S Frame and sealed to the front stiles and rails (which should have 5mmx30mm wide PVC strips) and attached to back of stiles and rails (which should have 5mm 45 degree bend portion as beading) and 10mm decorative PVC beading is used on the front side of panel externally impact perfact finish to the the shutter and joined together with solvent cement adhesive and 10mm thick (5mmx2x12mm wide PVC sheet is used as gap insert for top and bottom rail, 18mm x 1mm PVC edge lipping is done on top and bottom side. An additional of 5mm thick PVC strip of 12mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete all as specified and as directed.
Continuous piano hinges, mild steel, bright finish or electrogalvanised, 40mm flap width when open all as specified and directed.
Aluminium handles, cast type, anodized, 75mm size all as specified and directed.
Aluminium anodized barrel tower bolts of extruded section, 100 mm long all as specified and directed.
Non skid ceramic joint free coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Glazed ceramic coloured/printed tiles of size 300x200x6 to 7 mm thick as in vertical surfaces such as skirting, dado etc.,set & jointed in neat cement slurry and pointed with white cement mixed with pigment to match the colour of tiles including backing layer of 10 mm thick screed in cement mortar (1: 4) complete all as specified and directed.
Rendering 15 mm thick cement mortar (1:4) on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra lime or cement ,complete all as specified and directed.
Rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Applying two coats of oil emulsion distemper over a coat of cement primer on newly plastered surfaces of wall including preparation of surfaces, complete all as specified and directed .
Mild steel works as in bands, straps; hold fast; wall ties; plain angle cleats for securing purlins to rafters; Knee piece inserts; plate washers and similar small articles conforming to Fe 290Gde-E-165 complete all as specified and directed.
Second class hard wood, plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and directed.
Factory made 35 mm thick, second class hard wood plain framed, panelled shutters (any number of panels), with panels of 12 mm thick veneered particle board medium density, with commercial face veneers, fitted to chowkhats; size of various components as specified in SSR Part-I Section-8, complete all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces exceeding 10Cm in width or girth including preparation of surface complete all as specified and directed.
Plain cement concrete, (1:3:6) type C1 using 20mm graded stone aggregate as in hold fast block including necessary form work complete all as specified and directed.
25 mm thick plain cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate as in floors, finished even and fair complete all as specified and directed.
Fixing only galvanised corrugated mild steel sheeting with two corrugation side lap and fixed with L type or J type hook or cranked hook bolts and washers in roof/wall etc., (using old serviceable sheets obtained from dismantling) complete all as specified and directed.
Corrugated galvanized steel sheeting 0.63mm thick ( 275 gram galvanization per Sqm) with two corrugation side laps and fixed with L type or J type hook or cranked hook bolts and washers in roof/wall etc complete all as specified and directed.
Pre - painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre - painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screws complete all as specified and directed.
Taking down tarfelt with tiles and cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50 m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust complete all as directed.
15 mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, finished even and smooth without using extra cement complete all as specified and directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item ).
PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, finished even and smooth on exposed concrete surface without using extra cement complete all as specified and directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item as supply only).
Supply only integral water proofing compound conforming to IS:2645-1975\, complete all as specified and directed.
Water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.25 ltrs per Sqm over plastered surfaces of roof including parapet surface. (Note :- Bituminuous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd./STP) (b) Over the priming coat laying one layer of APP based polymembric membrane of approved manufacturer, 3 mm thick weight not less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done with torch application method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints with suitable adhesive as per manufacturer's instruction. (iii) APP bassed polymeric membrane shall be "MOPLY FP 3MM" manufactured by M/S Texsa India Limited/STP. (iv) Applying two coats of Aluminium paint over APP membrane.)
Preparation of new steel surface over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old painted steel surfaces of any description, not otherwise described for, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in lintel upto 1.50 metre clear span, cills, steps, seismic and other simillar bands, plinth courses, string courses, lacing cources, parapets and railing upto 60 cm in height , copings, kneelers, appex stones bed plates, water troughs and the like including weathering slightly rounded for chamfered angles and throating including form work complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Second class hard wood in scantlings clean sawn timber framed work fixed with nails complete all as specified and directed.
Non Asbestos fibre cement building boards 4 mm thick fixed or laid in aluminium frame work with screws as in ceiling complete all as specified and directed.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw or laid in aluminium frame work complete all as specified and directed.(Note:Aluminium frame shall be measured and paid seperately).
Interlocking aluminium power coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and directed.
Rilled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. including necessary fabrication, cutting to shape, drilling and welding complete conforming to Fe-410-W (Gde E-250) quality A complete all as specified and directed.
Erection and fixing only MS roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings etc. including necessary fabrication, cutting to shape, drilling and welding complete all as specified and directed.(Note:-Old serviceable structural steel obtained from dismantling shall be used).
110mm dia PVC (SWR) pipes, Type 'A' single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
110 mm dia PVC (SWR) bends of any radius with access door complete all as specified and directed.
110 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
Mild steel sheet eaves gutters, galvanised, class 3, half round with rounded edges 150mm dia and sheet thickness 1.25mm complete all as specified and directed.
Fixing only mild steel sheet eaves gutters, galvanised , half round with rounded edges of any dia and sheet thickness complete all as specified and directed.(Note:-Old serviceable gutter retrived from dismantling shall be used).
Supply and fix in repair angles (internal or external) or nozzle pieces (Out lets) 150mm dia with sheet thickness 1.00mm complete all as specified and directed.
M/s J. C. CONSTRUCTION
Shri Jyotibrata Chakrobarty
Bhuiya Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .