Loading…
Loading…
Tender ID
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
18 Feb 2026, 6:00 pmClosed
Ex.Eng (O&M) Valsad Rural Division
Tender For Supply and installation of 11/22 KV distribution Transformer HT/LT Terminal Protector and Supply of HT/LT Booting, Transformer Earthing, Sleeves (Conductor Cover), Bird Guard in Any Scheme for Transformers (Including Installation) of Rumla Sub-Division Under Valsad Rural Division.
273983
DGVCL/VALSAD-R DO/E-TENDER/2025-26/106
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹1,180
Yes
DGVCL, Payable @ Valsad
₹20,000
Yes
7 Feb 2026
7 Feb 2026
7 Feb 2026
18 Feb 2026
7 Feb 2026
-::- SCHEDULE-B -::-
The Rates inclusive of PF and Exclusive of GST
Item Code Item Unit FY 2024-25
Binding of messenger Conductor at with a
distance not more than 0.75 mtr with 6 turns
minimum on XLPE Cable with single strand
binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV
2 9926000086 PER SET
Resistance) with using 95/120/150 sq.mm long
barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of
bare conductor by HT ABC conductor (DO bottom
3 9926000087 side to transformer) after removal of PER SET
semiconductor by HT ABC (6 inch both side). HT
ABC to be supplied by DGVCL. (1Set = 3 Nos i.e.
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 2000 mm Electrode Length as per the
Tender Specifications and Drawing. (All Materials
Will Be Supplied by Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 3000 mm Electrode Length as per the
Tender Specifications and Drawing. (All Materials
Will Be Supplied by Agency)
Supply and Installation of 25 X 3 mm GI Strip
having hot dip- galvanized-zinc coating of 80-100
microns without any joints or welding. Both the
end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving
separate earthing connections to
6 9926000090 (1) Neutral of the transformer Meter
(2) MS structures of the transformer center
(Approximately 25-meter GI strip per transformer
- as per requirement and instruction of Engineer
in- charge) (All Materials will be supplied by
Supply and Installation of uPVC standard make
Pipe of 1.25" diameter for covering GI strip with
UV protected Cable Ties of 550 X 7.6 mm size to
7 9926000092 bind with pole face (Approximately 25-meter Meter
uPVC pipe for GI strip covering per transformer
center -as per requirement and instruction of
Engineer in-charge.
Supply & fixing of up to 33 kV Conductor sleeve
for Busbar to Drop out Fuse and Drop out fuse to
8 9926000093 Transformer H.T. including Busbar (12 mm sleeve) Meter
as per technical specification. (All Materials will
be supplied by Agency)
Supply & fixing of up to 33 kV Conductor sleeve
for Busbar to Drop out Fuse and Drop out fuse to
10 9926000094 Transformer H.T. including Busbar (15 mm sleeve) Meter
as per technical specification. (All Materials will
be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather resistant, Non-
11 9926000095 conductive bird guard OD=300 MM, ID=33 MM, NO
Width =1.25 MM, one side cut from ID to OD. (All
Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e.
Re-useable boot (LT Side 1.1 kV) including LT (1.1
kV) insulating taps. All live part at LT side shall be
covered with fixing of LT insulating taps.
13 Nylon Net around Transformer Center
13.1 9926000097 Nylon Net (12 * 15 ft) Per Net
13.2 9926000098 Nylon Dori Per TC
Labor charge for fitting Nylon Net (All fabricated
13.3 9926000099 material for fitting nylon net shall be provided by Per TC
1. DGVCL will provide key material like M.S.
materials, ABC/Bare conductors, SC/RSJ Poles,
Insulators, Fabricated materials etc. to the
contractor.2.All fabricated items shall be
fabricated as per DGVCL approved drawing and
by welding rods confirming to the relevant ISI
specification and as directed by Engineer in
charge.3.Necessary electricity connection for
fabricated items shall be provided by DGVCL on
payment of required charge for connection &
electricity bill of the same shall be paid by the
agency.4.All the rates are inclusive of PF and
Exclusive of GST applicable time to time.5.All steel
material are to be painted as below:(a) Scrubbing
of rusted surface properly before applying the
paints on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles is must.(b) Two coats
of approved ISI mark red oxide (primer) is to be
properly painted for the RSJ poles & steel
fabricated materials of RSJ/PSC poles. (c) Two
coats of approved ISI mark silver paint (i.e. triple
mangoes or equivalent quality silver paint) is to
be properly painted on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
Total of schedule B….
(+) _______%Above, (-) _______%Below, Rate to Rate….
Net Total of Schedule B:
Amount in Words: (Twenty lacs only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Rumla Sub-Division under Valsad-Rural
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary
accessories to the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and
crediting in to store & dismantling of service lines from LT bare conductor and to
provide service connections on ABC by insulated pierce connectors through service
connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as
credit the dismantle material to the DGVCL store at their cost.
1. DGVCL will provide key material like M.S. materials, ABC/Bare conductors, PSC/RSJ
Poles, Insulators, Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevant ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabricated items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by the
4. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5. All steel material is to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is must.
(b) Two coats of approved ISI mark red oxide (primer) are to be properly painted for
the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint)
are to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Executive Engineer (O&M)
Valsad Rural Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
GENERAL TERMS and CONDITIONS.pdf
Notice Inviting Tender.pdf
TECHNICAL BID.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
Amend an Arbitration Clause.pdf
Schedule-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .