| 1 | L1₹26.1 LAccepted-Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | ₹26.1 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹26.2 L+₹10,300 (0.39%)Accepted-Finance | ₹26.2 L+₹10,300 (0.39%) | L2 | Accepted-Finance 2nd Lowest Bidder |
Tender Value
₹26.2 L
EMD Value
₹52,500
Closing Date
9 Dec 2023, 5:00 pmClosed
AEE(Electrical)
CSIR-IHBT, PALAMPUR
Con of 12 No Type iv Staff Quarters at CSIR IHBT SITC of 01 No 13 Passenger Machine Room Less Gearless Elevator
2023_CSIR_175983_1
5-306/ws/2023
Open Tender
Electrical Works
Works
90 days
CSIR-IHBT Palampur
2 documents required · 2 mandatory
₹500
Director
₹52,500
12 Jan 2024
29 Nov 2023
11 Dec 2023
29 Nov 2023
9 Dec 2023
30 Nov 2023
29 Nov 2023 - 9 Dec 2023
Amount
Supply, installation, testing and commissioning of Machine Room Less, Gear Less,13 Passenger Elevator, 884 Kg capacity, having 05 Floors, 05 Stops, 05 Openings, 05 Levels (All on same side) with approx. travel 12 Mtr of TK Elevator (ThyssenKrupp)/KONE/SCHINDLER/ MITSUBISHI/OTIS as per detailed technical Specifications (from page 77 to 79 as mentioned in Tender Document).
Supplying and fixing of LED Bulk Head Fitting 10W. (Make: Panasonic /Bajaj/ Wipro/ Crompton ).
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West, FRLS copper wire make: Anchor/ Finolex/KEI/Polycab/ Havells) i) Group C
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required.(FRLS copper wire make: Anchor/ Finolex/KEI/Polycab/ Havells) i) 2x2.5 sqmm + 1x2.5 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required.(FRLS copper wire make: Anchor/ Finolex/KEI/Polycab/ Havells) i) 4x10 sqmm + 2x6 sqmm earth wire
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed stell/ PVC conduit as required. (FRLS copper wire make: Anchor/ Finolex/KEI/Polycab/ Havells) i) 4x6 sqmm
Supplying & fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit ar required. i) 25 mm
Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Providing and fixing following rating and breaking capacity and pole MCCB with adjustable thermal setting, thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 100A, 16KA, TPMCCB
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( But without MCB/RCCB/Isolator) (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 4 way (4 + 12), Double Door
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Single pole
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Tripple Pole & Neutral pole
Supplying & fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole & earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess with chained metal cover for the socket out let and complete with connection, testing and commissioning etc as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ).
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing & laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI Pipe from earth electrode including connection with copper thimble excavation & refilling as required.
Providing and fixing 4.00 mm dia. Copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submaain wiriring/cable as required.
PRAGATI ELECTRICAL & ELECTRONIC CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .