Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.0 L+₹28,453 (1.81%)Rejected-Finance | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹17.9 L+₹2.2 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Rejected due to L3 | |
| 4 | L4₹18.2 L+₹2.5 L (15.7%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L4 | Rejected-Finance Rejected due to L4 | |
| 5 | L5₹21.5 L+₹5.8 L (36.9%)Rejected-Finance MANGERIYA MANGERIYA BHOPALGARGH JODHPUR 342901 | JODHPUR | JODHPUR | RAJASTHAN | 342901 | L5 | Rejected-Finance Rejected due to L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Jun 2025, 6:00 pmClosed
AGE (Contracts)
Military Engineer Services, Garrison Engineer (Army) No 2 Jodhpur, Multan Lines, Army Area Jodhpur -342010
REPAIR/ REPLACEMENT/ MAINT OF INTERNAL WIRING, FITTINGS AND FIXTURES IN OTM ACCN AT SHIKARGARH AND ADJOINING AREA UNDER GE (ARMY) NO 2 JODHPUR
2025_MES_707028_1
8800/25-26/10/05/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (Army) No 2 Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (Army) No 2
₹70,000
Yes
19 Jul 2025
8 May 2025
7 Jun 2025
8 May 2025
5 Jun 2025
22 May 2025
8 May 2025 - 15 May 2025
Amount
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and as directed.
M&L for point wiring (Modular point wiring if required with modular accessories cover plate etc.) One light/Fan/bell point/Exhaust Fan controlled by one switch one way complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes,cover plate etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover complete all as specified and as directed by Engineer-in-Charge.
All as per items srl No 2 above but for One socket out let 5 Amps 5 Pin on same board with other switch.
All as per items srl No 2 above but for One socket out let 5 Amps 5 pin on independent board.
All as per items srl No 2 above but for One light point controlled by two switch two way.
All as per item No 2 here in before but with single core multistranded cable of size 4.0 Sqmm for one 15 Amps socket outlet on independent board and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge.
Material and labour for point wiring One light/Fan/bell point/exhaust fan complete with 1.5 sq mm single core multi stranded copper conductor PVC FRLSH insulated unsheathed 1100 Volt grade cable in and incl PVC FRLS new casing capping of size (ISI Marked) with accessories including new pressed steel terminal boxes (sunk in wall ) with 3.00 mm thick plastic laminated sheet top cover or PVC FRLSH board including PVC FRLSH top cover or Modular sunken box with modular plate and cover with 1.50 sq mm insulated unsheathed PVC FRLSH multistranded covered copper conductor for common earth and connecting to earth dolly and making good disturbed surface of wall incl matching the colour of wall/ceiling with extisting wall/ceiling colour all as specified and directed
All as per items srl No 4 above but for One socket out let 5 Amps 5 Pin on same board with other switch
All as per items srl No 4 above but for One socket out let 5 Amps 5 pin on independent board
All as per items srl No 4 above but for One light point controlled by two switch two way.
All as per item No 4 here in before but with FRLSH multistranded cable of size 4.0 Sqmm and multistanded insulated copper earth continuity conductor of size 4.0 Sq mm all as specified and directed by Engr-in-Charge for one socket outlet 15 Amp power point on Independent board.
Material and labour in replacement for Elect bell AC 230 Volts single phase musical type complete all as specified and as directed.
Material and labour in replacement for bell push flush type 5 Amps complete all as specified and as directed.
Supply and fixing in replacement switch piano flush type 5 Amps single pole one way complete all as specified and as directed.
Supply and fixing in replacement switch piano flush type 5 Amps single pole two way complete all as specified and as directed.
Supply and fixing in replacement socket out let 2 in 1 multi pin 5 Amps flush type complete all as specified and as directed.universal
Supply and fixing in replacement switch piano15/16 Amps one way 240 volts complete all as specified and as directed.
Supply and fixing in replacement socket outlet in repair 2 in 1, 3 pin, 5 and 15 Amps socket outlet 240 volts complete all as specified and as directed.
S&F in replacement modular bell push 6 Amps single module complete all as specified and as directed.
Supply and fixing in replacement modular switch 6 Amps single module one way complete all as specified and as directed.
Supply and fixing in replacement modular switch 6 Amps single module two way complete all as specified and as directed.
Supply and fixing in replacement modular socket 6 Amps 5 pin double module complete all as specified and as directed.
S&F modular switch 16 Amps single module complete all as specified and as directed.
Supply and fixing in replacement modular socket 6&16 Amps 5 pin double module complete all as specified and as directed.
Supply and fixing in replacement modular Fan step regulator 120W, two module complete all as specified and as directed.
M&L concealed Modular metal flush box upto upto 6 module and making good all disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed.
All as per items srl No 20 above but for 4 module complete all as specified and as directed.
All as per items srl No 20 above but for 3 module complete all as specified and as directed.
All as per items srl No 20 above but for 1 module complete all as specified and as directed.
S&F in repairs Modular white cover plate with frame upto 06 module complete all as specified and directed by engineer-in-charge
All as per items srl No 21 above but for 04 module complete all as specified and as directed.
All as per items srl No 21 above but for 03 module complete all as specified and as directed.
All as per items srl No 21 above but for 01 module complete all as specified and as directed.
Supply and fixing in replacement on off push 25A, two module with plate complete set complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and as directed
Supply and fixing in replacement Ceiling rose on PVC FRLS board size 65 X 50 mm three terminal complete all as specified and as directed
Supply and fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps B curve type ,230 volts, 10 KA complete all as specified and as directed
Supply and fixing in repair Lamp Holder, PVC FRLS/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in replacement of old unsv LED Tube light1 X 20 watt (04 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed. Make : CROMPTON , BAJAJ/HAVELLS/PHILLIPS
S&F in replacement of old unsv LED Tube light1 X 10 watt (02 feet), decorative ultra slim type, with integral driver, complete with all accessories and making necessary electric connection from ceiling rose to fitting terminal, complete all as specified and directed Make : CROMPTON , BAJAJ/HAVELLSPHILLIPS
S&F in replacement of old unsv LED 15 watt Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head LED luminaire comprising of high brightness LEDs, IP54 protection complete all as specified and as directed. Make : CROMPTON , BAJAJ/HAVELLS/PHILLIPS
S&F in replacement of old unsv LED Decorative wall light fixture made up of Polycarbonate, suitable for LED Bulb 09/12W(B-22 base) complete all as specified and as directed. Make : CROMPTON , BAJAJ/HAVELLS/PHILLIPS
M&L for in repair/replacement sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for in repair/replacement sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for in repair/replacement sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10 Sqmm and one run of 10Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
S&F in replacement of old unsv LED Tube light 20 watt batten emergency type with high quality materials polycarbonate and tranlucent serrated milky white diffuser to get glare free, smooth light distribution, thermoplastic aluminium housing enhance safety and luminaire is pre-wired with high effiency electronic driver and LED lamp power backup of 3 to 4 hrs including up with three core flexible copper conductor cable suitable size complete with all accessories and necessary connection complete all as specified and as directed. Make : CROMPTON , BAJAJ/WIPRO/HAVELLS/HPL/PHILLIPS
S&F in replacement of old unsv LED Tube light 10 watt batten emergency type with high quality materials polycarbonate and tranlucent serrated milky white diffuser to get glare free, smooth light distribution, thermoplastic aluminium housing enhance safety and luminaire is pre-wired with high effiency electronic driver and LED lamp power backup of 3 to 4 hrs including up with three core flexible copper conductor cable suitable size complete with all accessories and necessary connection complete all as specified and as directed. Make : CROMPTON,BAJAJ/HAVELLS/HPL/PHILLIPS
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 08 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS
Supply, fixing, connecting & testing sheet metal enclosures double door, single pole and neutral, 12 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing complete all as specified and as directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS/ABB
S&F in replacement of Vertical Distribution Board (Concealed flush to wall), double Door, suitable for 'A' Frame FP MCCB 125 A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 4 way, 415 volts with bus bar rating 250 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS/ABB
S&F in replacement of MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 25 kA, 415V, 125 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed.
Supply, fixing, connecting & testing sheet metal enclosures double door, TPN 04 way DBs,415 V, DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating with IP-42 protection complete including taking down existing all as specified and directed. Note : Rates are deemed to be included for flushing in wall concealed complete making good and matching existing surface. Make:- Legrand /C&S /L&T /INDOASIAN /Havells/ABB
Supply and fixing in replacement 415V, 16 KA 'C' curve miniature circuit breaker (MCB) of triple poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS/ABB
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS/ABB
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and neutral current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. Make:- Legrand /C&S /L&T /INDOASIAN/HAVELLS/ABB
M&L for Earthing complete with GI steel earth plate eletrode 60 cm X 60 cm X 6.0 mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metres below level ground,connected to Gl iron or steel earth wire 4 mm dia (8 SWG) by means of nuts,bolts checks nuts and washers made of Gl iron or steel earth wire protected by Gl iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6:) type C1, pre-cast RCC coverslab 30 cm X30 cm X 10 cm with one lifting handle made of 8 mm dia ms bar funnel wire mesh,20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges,necessary excavation and earth work in any type of soil complete all as shownin electrical plate No 3 of MES schedule part-I and testing after completion.
DURGA ENGINEERING COMPANY (BID ID -3313803)
M/S VENUS BUILDER (BID ID -3308024)
M/s Shiv Builder and Suppliers (BID ID -3306333)
M/s JOG SINGH MATERIALS (BID ID -3308680)
Surendra Singh (BID ID -3307927)
M/S KAUTILYA GARG (BID ID -3313915)
Nikhat nirman (BID ID -3313093)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .