EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
ENGINEERING COMPLEX RAJBAGH NEAR SILK FACTORY SRINAGAR
Construction of 04 roomed double storied school building at Govt. UPS Gundidervash including toilet/ electrification B.W.O providing internal electrification facility.
2026_PWDJK_306072_1
NIT No.323/2025-26 Dt/12/03/2026
Open Tender
Electrical Works
Percentage
ZAINAPORA
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹5,458
13 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
23 Mar 2026
13 Mar 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha /eq. standard make as desired by engineer incharge .), modular plate,suitable GI box, deep junction etc and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha / equivalent as directed by engineer incharge)
Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha / equivalent as directed by engineer incharge.)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required.
(b) 2 X 10sq. mm + 1 X 6 sq. mm earth wire ( sub main wire from main panel to Individual DB's)
Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena / equivalent as directed by engineer incharge.)
Sub Head-2 - Fixtures and Fittings
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Phillips/ trulux/ wipro/ eq. make to be approved by EIC. sample to be approved before installation..
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including Fan Junction complete . USHA /Havells /Crompton/ eq. make, sample to be approved before installation..
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral / equivalent as directed by engineer incharge.
Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls ABB SB200/Legrand Dx3/Seimens Betaguard/ Schneider Acti_9/equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK / equivalent as directed by engineer incharge) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
10 way, Double door
Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.
S/L , testing and commissioning of, XLPE Insulated, PVC alluminium cable ( unarmoured) 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
a) 16 sq.mm 2 core
Earthing with G.I earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt) as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply installation testing and comm. Of control pannel outdoor type duly manufactured from (CPRI approved panel manufacturers) sheet steel 16SWG powder coated phosphatised having angle iron stand/ wall mounted fitted with following accessories to be grouted in the cement concrete, complete job (As per approved Design)
Supply installation testing and comm. Of control pannel outdoor type duly manufactured from (CPRI approved panel manufacturers) sheet steel 16SWG powder coated phosphatised having angle iron stand/ wall mounted fitted with following accessories to be grouted in the cement concrete, complete job (As per approved Design) a) 200 amp 2 strip bus 2 No. b) A/V meters set/indicators c) space for 6 way MCB's d) 100 amp DP MCCB 25K Legrand/ Shinider/ L&T / equivalent as directed by engineer incharge. 1 NO.
Supply, Installation, testing and commissioning of relay based, wall mount, 2KVA voltage stabilizer suitable for 1600 VA inverter, operating from input voltage 90-260 Volts thereby producing output voltage of 220 volts +/- 3 % ( 2 KVA) ( Vguard/ Livgaurd/LG / equivalent as directed by engineer incharge)
Supply installation testing and comm.of invertor battery 180 AH/12 V Exide invatubular/ eq. standard make as directed by engineer incharge.
Supply installation testing and commissioning of Sine Wave Inverter, Capacity 1000VA, ,Supporting 1 no. battery,24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide make. The job also includes the PVC Trolly suitale to hold 1No. Battries and the inverter. ( Complete job)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
BOQ_993992.xls
BOQ • 0.31 MB
corrigendumNIT323-324.pdf
PDF • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .