Loading…
Loading…
Tender Value
₹26.7 Cr
EMD Value
₹14.8 L
Closing Date
27 Jan 2026, 12:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
24 conditions · 13 needing a document upload
Financial Eligibility Criteria Criteria (Para-10.2 (Pt-I) of GCC April 2022):The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per AnnexureVIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Bid capacity: For tenders having advertised value more than Rs 20 crore wherein eligibility criteria includes bid capacity also, the tenderer will be qualified only if its available bid capacity is equal to or more than the total bid value of the present tender. The available bid capacity shall be calculated as under: Available Bid Capacity = [A x N x 2] - 0.33xNxB Where, A = Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender), taking into account the completed as well as works in progress. N= Number of years prescribed for completion of work for which bids has been invited. B = Value of existing commitments and balance amount of ongoing works with the tenderer as on date one month prior to the tender closing date to be completed in next 'N' years. Note: (a)The Tenderer(s) shall furnish the details of - (i)Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender) for calculating A, and (ii)Existing commitments and balance amount of ongoing works with tenderer as per the prescribed proforma of Railway for statement of all works in progress and also the works which are awarded to tenderer but yet not started upto the date of inviting of tender for calculating B. In case of no works in hand, a 'NIL' statement should be furnished. The submitted details for (i) and (ii) above should be duly verified by Chartered Accountant. (b)In case if a bidder is JV, the tenderer(s) must furnish the details of (i)Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender) by each member of JV for calculating A, and (ii)Existing commitments and balance amount of ongoing works with each member of JV either in individual capacity or as a member of other JV as per the prescribed proforma of Railway for statement of all works in progress and also the works which are awarded to each member of JV either in individual capacity or as a member of other JV but yet not started upto the date of inviting of tender for calculating B. In case of no works in hand, a 'NIL' statement should be furnished. The submitted details for (i) and (ii) above should be duly verified by Chartered Accountant. (c)Value of a completed work/work in progress/work awarded but yet not started for a Member in an earlier JV shall be reckoned only to the extent of the concerned member's share in that JV for the purpose of satisfying his/her compliance to the above mentioned bid capacity in the tender under consideration. (d)The arithmetic sum of individual "bid capacity" of all the members shall be taken as JV's "bid capacity". (e)In case, the tenderer/s failed to submit the above statement along with offer, their/his offer shall be considered as incomplete and will be rejected summarily. (f)The available bid capacity of tenderer shall be assessed based on the details submitted by the tenderer. In case, the available bid capacity is lesser than estimated cost of work put to tender, his offer shall not be considered even if he has been found eligible in other eligibility criteria/tender requirement.
Technical Eligibility Criteria: The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Definition of similar work: "(1) Erection of 33KV or above voltage level sub-station" Or "(2) Erection and commissioning of 33KV or above voltage level line (overhead or underground)". Tender not accompanied by documentary evidence in support of eligibility criteria for similar nature of work will be summarily rejected. (For complete details of the technical eligibility criteria for similar nature of the work, please refer clause 2.0, chapter-3 of the tender document).
(b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfilment of technical eligibility criteria for different components.
(b) (2) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity.
(b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contract or through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing.
Tender not accompanied by documentary evidence in support of eligibility criteria for similar nature of work will be summarily rejected. (For complete details of the technical eligibility criteria for similar nature of the work, please refer clause 2.0, chapter-3 of the tender document).
Contractors should have valid electrical contractors license for the required voltage level or above the required voltage level issued from any state/Central government licensing board. The intended participant shall upload the valid Electrical contractor's license along with the offer/tender as credential.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Regarding technical and financial eligibility criteria, scanned copies of supportive documents/certificates from competent officials are to be submitted along with their offer.
Scanned copies of documents in support of formation/registration of the company/firm/legal authorization of the person to deal with the tender/notarized/registered copies of the documents wherever required as per tender conditions are to be submitted along with offer.
If a bidder has successfully completed a work as subcontractor and the work experience certificate has been issued for such work to the subcontractor by a Govt. Organization or public listed company as defined in Note for Item 10.1 Para 10 of the Tender Form (Second Sheet), the same shall be considered for the purpose of fulfillment of credentials.
During the execution of work, all materials brought to site by the Contractor must be offered for inspection within advance notice of one month prior to actual date of inspection. Inspection of materials will generally be done by RITES. If volume of material of nature does not fall in the category of RITES inspection, then inspection of material will be done on the basis of MTC & GC ( Manufacturer's TC & GC ). All site acceptance of material must be maintained in one material receipt & issue Register which may be verified by any agency at any time
28 conditions · 16 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers shall note that the submission of other supporting documents namely- Constitution of firm/JV firm, Work in hand, Arbitration/Court cases,Tools & Plants, Technical Personnel/Man Power and Association of railway Officers, at the time of on line bidding of tender, is important and they shall ensure the same. However Railways may seek clarifications/details/documents in this regard.
Tenderers shall note that the submission of other supporting documents namely- Constitution of firm/JV firm, Work in hand, Arbitration/Court cases,Tools & Plants, Technical Personnel/Man Power and Association of railway Officers, at the time of on line bidding of tender, is important and they shall ensure the same. However Railways may seek clarifications/details/documents in this regard.
PLEASE FILL IN REQUIRED INFORMATION ASKED FOR IN THE SPECIFIED SPACE IN THE E-TENDER. TENDER WILL BE OTHER WISE TREATED INCOMPLETE AND HENCE WILL BE LIABLE FOR REJECTION.
THE QUANTITY SHOWN IN THE SCHEDULES ARE APPROXIMATE AND ARE LIKELY TO VARY ON EITHER SIDE (+/-) AS PER CLAUSE- 2 OF SPECIAL CONDITIONS OF CONTRACT.
As this is a running contract, work order shall be issued as and when site is available. Contractor to plan for supply, erection and commissioning based on work order & handed over sites and approved layout of these sites.
Running contract for removing of HT (33/11KV) & LT over head electrical lines of SBPDCL/other authorities and other electrical associated work coming in alignment of proposed new line in between Bihta (Excl.)-Anugrah Narayanroad (Excl.) including Bihta ROR, 3rd-4th line between Baktiyarpur-Fatuha & Punarakh-Barh- Baktiyarpur section and any other location under CEE/C/S/MHX.
ELCSMHX-ETEN-05-25-26~ECR
ELCSMHX-ETEN-05-25-26
Open
Works - General
24 Months
Purbi Champaran, Bihar
₹0
₹14.8 L
27 Jan 2026
2 Jan 2026
13 Jan 2026
84 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | 150.00 | — | — | ||
| Supply at site BFB type (6"x6") dip dalvanised mast 9.5/ 11 mtr long. | — | — | — | 1,70,09,959.5 | |
| — | 225.00 | — | — | ||
| Erection and casting of foundation for Rail/tubular pole/GI mast with earth exevation with PCC 1;3:6 ratlo (Cement,Sand,Ballast) as per Org. No.EL/T/5/76. | — | — | — | 5,32,631.25 | |
| — | 225.00 | — | — | ||
| Muffing of foundation of Rail/tubular pole/GI mast of (0.45x0.45x1)m with cement concrete mixture etc. with 1:3:6 ratio. | — | — | — | 1,02,894.75 | |
| — | 128960.00 | — | — | ||
| Supply, fabrication and fixing of G.I channel/angle of the required sizes including fastener. | — | — | — | 1,53,72,032 | |
| — | 22.00 | — | — | ||
| Drawing of HT/LT overhead with ACSR conductor (per running km) including binding insulators, jumpering terminals with suitable size PG clamp & aligning properly. | — | — | — | 95,460.64 | |
| — | 22.00 | — | — | ||
| Supply and delivery of ACSR conductor 6+1/3.00 mm at site. | — | — | — | 5,64,091.22 | |
| — | 11000.00 | — | — | ||
| Supply & delivery of 8 SWG GI wire for guarding and lacing at site. | — | — | — | 10,15,740 | |
| — | 22.00 | — | — | ||
| Drawing of guard wire and lacing wire including stretching, tensioning & stringing, lacing with 8 SWG GI wire at lest 5 nos in each span complete etc. as required. | — | — | — | 90,432.32 | |
| — | 46.00 | — | — | ||
| Supply ,installation, testing & commissioning of 11KV lightening arrester on top of the post with supply & fixing of 100mmx50mm M.S. channel including separate earthing arrangement by 2x50mm dia . Medium gauge G.I. pipe TATA/Jindal make 3 m long as per CEE/CCC's specification as 4 SWG GI wire from earthing station to L.A. (Each set containing 3Nos of LA). | — | — | — | 2,00,362.66 | |
| — | 46.00 | — | — | ||
| Supply ,fixing, connection, testing & commissioning of GOS of 11KV , 3 pole, 400A with locking arrangement and all other accessories including supply of 100mmx50mm channel & other hardware materials for fixing of GOS complete etc. as required. Make ADCO/BHEL or similar ISI approved make. | — | — | — | 7,36,534.98 | |
| — | 4500.00 | — | — | ||
| Supply and delivery of 3 Core, 185mm2, 11KV XLPE insulated, armored alluminum conductor cable. (Make: Gloster, Crystal, Polycab, Havels, MP cab or similar ISI marked IS: 7098 (Pt.II)/1985 or CEE's/ER/NER approved make. | — | — | — | 1,81,58,175 | |
| — | 12000.00 | — | — | ||
| Supply and delivery of 3 Core, 300 mm2, 11KV XLPE insulated, armored alluminum conductor cable. (Make: Gloster, Crystal, Polycab, Havels, MP cab or similar ISI marked IS: 7098 (Pt.II)/1985 or CEE's/ER/NER approved make. | — | — | — | 6,93,89,160 | |
| — | 184.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of outdoor type heat shinkable/epoxy cable end terminal box complete with kit & jointing compound ( including jointing and sealing ) suitable for armored cable including connection of the cable with overhead conductor by supplying suitable size aluminum sockets , jumpers and P.G/U-clamps, suitable for 11KV 3-core, 185 mm², XLPE insulated Al-conductor armored cable. (Make :M-Seal ,Raychem,Denson) | — | — | — | 15,60,643.84 | |
| — | 60.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of outdoor type heat shrinkable straight through jointing kit suitable for 11KV 3 core, 185mm², XLPE insulated Al- conductor armored cable. (Make :M-Seal, Dension,Raychem) | — | — | — | 10,72,176.6 | |
| — | 276.00 | — | — | ||
| Supply and fixing of 11 KV Disc insulators complete with bolted type tension clamp & all other accessories.(The tension clamp should be of suitable size and conform to ISI specification. | — | — | — | 2,13,011.28 | |
| — | 270.00 | — | — | ||
| Supply and fixing of 11 KV pin insulators long with necessary hardware . | — | — | — | 91,033.2 | |
| — | 600.00 | — | — | ||
| Supply & fixing of MS galvanized anchor rod of size 3/4" dia & 8' long complete with anchor plate (300x300x10)mm including foundation with P.C.C 1:3:6 along with supply & fixing of stay wire 7/10 SWG stay insulator, clamp made of M.S flat 65mm x 6mm and suitable fasteners, turning screw on both sides including tensioning of guy set. | — | — | — | 14,49,210 | |
| — | 300.00 | — | — | ||
| Supply & erection of earthing station as per CEE/CCC's specification with GI earth electrode , 50mm dia and 3m long medium gauge ISI marked G.I pipe brackets at both ends and provided with alternate layer of charcoal and salt in the pit and connection with 6 SWG , G.I. wire from earth electrode to panel /octagonal pole along with masonry work encasing the pit. | — | — | — | 6,01,062 | |
| — | 3.00 | — | — | ||
| Supply & delivery of AAAC Panther conductor having size 37/3.15 mm at site | — | — | — | 12,94,800 | |
| — | 72.00 | — | — | ||
| Supply & fixing of 33KV pin insulators 278mmx242mmx280mm size one bracket complete with large steel head G.I. Pipe nuts bolts washer etc. as required. conforming to IS:731/1963 with latest amend no. 4BS:137 IEC:383 Make-Joy shree/REE/BHEL or any ISI marked. | — | — | — | 1,03,039.92 | |
| — | 36.00 | — | — | ||
| Supply and fixing of 33 KV Disc insulators complete with bolted type tension clamp & all other accessories. (The tension clamp should be of suitable size and conform to ISI specification) | — | — | — | 1,14,968.16 | |
| — | 32.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of outdoor type Heat shrinkable/ epoxy cable end terminal box complete with kit & jointing compound (including jointing and sealing) suitable for armored cable including connection of the cable with overhead conductor by supply suitable size aluminium sockets, jumpers and P.G/U-clamps, suitable for 33KV 3-core, 400mm2, XLPE insulated Al-conductor armored cable. (Make :M-Seal, Raychem, Denson) | — | — | — | 19,08,715.52 | |
| — | 8.00 | — | — | ||
| Supply, installation, connection, testing and commissioning of outdoor type heat shrinkable straight through jointing kit suitable for 33KV 3 core, 400mm², XLPE insulated Al- conductor armored cable. (Make :M-Seal, Dension,Raychem). | — | — | — | 7,27,042.08 | |
| — | 3200.00 | — | — | ||
| Supply and delivery of 3 Core, 400mm², 33KV XLPE insulated, armored aluminium HT conductor cable.(Make: Gloster /Crystal/CCIL/MPCab/Havells , or similar ISI marked IS: 7098(Pt.II)/1985 or CEE's ER/NER/ECR approved make) | — | — | — | 3,19,95,616 | |
| — | 4500.00 | — | — | ||
| Supply of medium gauge TATA/ JINDAL/ Bansal/ ISI marked G.I. pipe for protection of cable. (Fixing Cost included in laying of cable). (a) 150 mm dia | — | — | — | 54,20,025 | |
| — | 8500.00 | — | — | ||
| Supply of medium gauge TATA / JINDAL make Or any ISI marked G.I. pipe for protection of cable. (Fixing Cost included in laying of cable). (a) 100 mm dia | — | — | — | 80,68,880 | |
| — | 6500.00 | — | — | ||
| Insertion of GI/HDPE pipe by horizontal drilling pipe pushing method. | — | — | — | 1,01,15,495 | |
| — | 6500.00 | — | — | ||
| Supply of heavy gauge HDPE pipe 150mm dia for protection of cable | — | — | — | 27,21,680 | |
| — | 8500.00 | — | — | ||
| Supply and delivery at site of PVC insulated (Heavy duty) of 4 Core, 185 mm², 1100V PVC/ XLPE insulated, armored Aluminium conductor cable.(Make: Gloster, Crystal , Havells, M cab or approved by CEE/CON/ECR) | — | — | — | 2,16,66,500 | |
| — | 8500.00 | — | — | ||
| Supply and delivery at site of PVC insulated (Heavy duty of 4 core,70 sqmm ,650/1100V PVC/XLPE insulated ,armored aluminium conductor cable(Make: Gloster/Crystal/ Havells/RR Kabel/Mescab/Polycab/MPCab or simillar ISI marked IS 7098(Pt.I)/1988 or CEE/ECR approved make) | — | — | — | 58,38,055 | |
| — | 12000.00 | — | — | ||
| Supply and delivery of 4 Core, 120mm², 650/1100V PVC/ XLPE insulated, armored aluminium conductor cable.(Make: Gloster /Crystal/CCIL/MPCab/Havells , or similar ISI marked IS: 7098(Pt.I)/1993 or CEE's ECR approved make) | — | — | — | 1,28,68,200 | |
| — | 8000.00 | — | — | ||
| Supply & delivery at site of Aluminium conductor XLPE insulated armoured overall PVC sheathed 4 core 300 sq mm 1100 volt grade Power Cable Conforming to IS :1554/7098( part- I)1988 with latest ammendment.(Make: Gloster /Crystal/Polycab/Havells ISI Marked | — | — | — | 1,81,96,240 | |
| — | 200.00 | — | — | ||
| Fabrication & supply of heavy gauge steel tubular pole of 9.5 m long as per 410 SP 39 & IS-2713/980 bottom size 165.1 mm dia & 5.40 mm thick, middle 139.7 mm dia & 4.5 mm thick, top 114.3 mm dia & 3.25 mm thick along with Anchor base plate 400 mm x 400 mm x 6 mm, | — | — | — | 27,59,426 | |
| — | 200.00 | — | — | ||
| Erection and Casting of foundation for Rail/tubular pole/GI mast with earth excavation with PCC 1:3:6 ratio (Cement, Sand, Ballast) as per Drg. No EL/T/5/76 | — | — | — | 4,73,450 | |
| — | 9.00 | — | — | ||
| Supply, installation, testing and commissioning of3 phase, 50Hz, 100KVA out door ONAN typedistribution transformer conforming to IS:2026provided with off load tape changer on HV side +5% to -5% in steps of 2.5% of rating 11KV/415 Vas per CEE/CCC's specification (Make:ALSTHOM/BHEL/SIEMENS/CGL/ALIND/CG/Eastern Transformer or similar) | — | — | — | 30,92,976 | |
| — | 7.00 | — | — | ||
| Supply, installation, testing and commissiong of 3 phase, 50Hz, 250KVA, out door type distribution transformer conforming to IS:2026 provided with off load tape changer on HV side + 5% to -5% in steps of 2.5% of rating 11KV/433 V as per CEE's specification . (Make: ALSTHOM/BHEL/SIEMENS/CGL/ALIND/ Crompton greaves/Swadesi/ Eastern transformer Pvt Ltd/Stanlec) (70% payment will be made against supply of material) | — | — | — | 52,33,234.02 | |
| — | 45000.00 | — | — | ||
| Laying of cable {4+1(spare)to be layed for single core cable}partly through trench at a depth of 1m and filling with sand, brick work (16 nos. of bricks per meter run ) or under the road by laying of G.I./HDPE pipe at depth of not less than 1m or either in existing masonary trench or on cable tray or fixed on wall/post with suitable MS flat 35x6mm clamp and saddle including supplying and fixing suitable end termination with cable gland and aluminium lugs wherever required as per instruction of engineer -in-Charge, and refilling with earth etc. complete as required.(Cable supplied by Rly) | — | — | — | 59,30,100 | |
| — | 4.00 | — | — | ||
| Supply, fixing, connection and testing of AT output points consisting of 1 no ICTPN 63Amps switch enclosed in MS hinged box with locking arrangement. | — | — | — | 10,552 | |
| — | 50.00 | — | — | ||
| Supply and erection of cable route marker complete etc. as required. | — | — | — | 9,969.5 | |
| — | 800.00 | — | — | ||
| Supply & fixing of large size L.T Pin / Shakle insulators.( as per ISI specification). | — | — | — | 63,632 | |
| Each Span | 60.00 | — | — | ||
| Dismantling of ACSR from insulators etc. and retensioning properly, jumpering with suitable size PG/U lamps of existing crossing under shut down from JSEB/BSEB authorities. | — | — | — | 59,078.4 | |
| — | 35.00 | — | — | ||
| Cutting of Rail post including dismantling of brackets, Insulators etc. | — | — | — | 11,487.35 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .