| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.8 L+₹2.1 L (5.42%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.7 L+₹5.0 L (12.9%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹47.0 L+₹8.3 L (21.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹47.7 L+₹8.9 L (23.1%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹48.6 L
EMD Value
₹97,300
Closing Date
9 Mar 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-63/2019-20 MANNING AND OPERATION OF ESC POWER HOUSE, RACE COURSE POWER HOUSE, OPERATION OF DG SET AT NGCCM, 702SU, DARIN-II INCLUDING ALLIED WORKS AT AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_320780_2
GE AF/AMB-63/2019-20
Open Tender
Civil Works
Item Rate
330 days
GE AF AMBALA
ALL AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹97,300
Yes
23 Mar 2020
24 Feb 2020
11 Mar 2020
24 Feb 2020
9 Mar 2020
25 Feb 2020
Amount
Manning & Operation of switchgear / breaker including attending external electric complaints of HT/LT electrification including, OH lines, etc. by providing 01 (one) qualified electrician, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 electricians) on all days including Sundays and holidays for technical area at ESC power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of switchgear / breaker including attending external electric complaints of HT/LT electrification including, OH lines, etc. by providing 01 (one) qualified electrician, in 03 (three) shifts of 8hours each (round the clock 24hrsx3 shifts = 3 electricians) on all days including Sundays and holidays at Race Course power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge
Manning & Operation of substation with 1No. DG set 250kVA including operation of LT panel, AMF panel by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for NGCCM complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG sets 125kVA, 1No. DG set 75kVA and 1No. DG set 62.5kVA including operation of LT panels, AMF panels by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for 702SU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 2Nos. DG sets 62.5kVA, 1No. DG set 250kVA including operation of LT panels, AMF panels by providing 01 (one) FGM, in 02 (two) shifts of 8hours each (0800 to 1600hrs & 1600hrs to 2400hrs) = 2 FGMs on all days including Sundays and holidays for Darin-II and SES bay complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Notes for serial item Nos. 1 to 5: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) 'NIL'or 'Zero' quoting of rates against any items will be treated as 'Non Bonafide'. (iii) The rate quoted shall not be less than minimum fair wages as notified by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable. In case, the rates quoted by the bidder are less than the minimum fair wages as notified by the Government of India / State Government / Local body / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, his tender will be treated as 'NON BONAFIDE' and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) The minimum wages as derivied by the Deartment including all statutory provision such as ESIC, Bonus, GST, taxes, etc. except the Contractor's profit for skilled person works out to Rs. 705/-per person per shift and for un-skilled person Rs. 552/- per person per shift (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase will be passed over to the workers
M&L for servicing & calibrating damaged / faulty (overload current/ earth fault, etc.) VCBs of any make, at site on location, immediately on situation of any fault, and restoring funcionality with and including replacing of minor parts viz. HRC fuses, indicator lamps, control wiring, etc. oiling, greasing, cleaning with blower from inner and outer sides, decarburizing of the links with CRC spray, etc. checking serviceability complete all as specified and as directed Notes: (i) Work of overhauling, servicing, testing, etc. shall be got done through Engineer/ Technician of manufacturer (ii) Overhauling & servicing shall be done to the tune of complete serviceability / functionality of the VCB (iii) All costs of technician/Engineer on hire, minor spares, any sort of conveyance of man and material, testing & calibrating equipment, etc. shall be deemed to be included in the quoted rate
Supply, install, testing and commissioning 66kV class station heavy duty metal oxide gapless type LA for use with effective ground natural system with insulating base including surge monitors for 66kV with all accessories meeting and catering the requirement detailed as under complete all as specified and as directed (a) Nominal system voltage- 66kV (rms) (b) Highest system voltage - 72.5kV (rms) (c) MCOV 52kV (d) Nominal discharge current- 10KAP (e) Line discharge- Class 3 (f) High current discharge- 100KAP (g) Maximum residual voltage- 165KVP at 01KAP
Supply, install, testing and commissioning battery bank 110V /100AH , as per relevant IS complete all as specified and as directed with and including the following:
(i) Battery dry type 2Volt 100AH- 55Nos (ii) M6 x 25mm Hex headbolt SS 304- Passi- Kun 80- 115Nos (iii) M6 F washer SS 304 (6.5x19.0x3mm)- P- 115Nos (iv) M6 spring washer SS 304 (6.1x11.8x1mm) - 115Nos (v) Bottom support 10/120/200/240Ah- WG - 02Nos (vi) 12 CL- IP 6005/7005 PVC front cover - RT- 05Nos (vii) 110x20x2mm ICC connector (H) - 35Nos (viii) 73x20x2mm ( ICC (V) connector - 14Nos (ix) 118x20x2mm- ICC connector - 11 PL(V) - 04Nos (x) Serial No. 1- 56 sticker - 01No (xi) M8x 25 Hex bolts GI - 14Nos
(xii) M 10 flat washer GI (11.0x22x2.5mm) - 28Nos (xiii) M8 Hex nuts GI (13.0x6.5mm) - 14Nos (xiv) I&C manual for stand by -Ip series -01No (xv) System indentification lable for 100Ah - 03Nos (xvi) Petroluem jelly - 20G - 0.040kg (xvii) Front cover fixing leg for new type FC - 22Nos (xviii) -VE UPTPA12 CITRAY05PL- 25x3mm -MS-WG- 01No (xix) +VE DOWNTPA 12CITRAY05PL-25x3mm-MS-WG- 01No (xx) 135x20x2mm IMC/ECC connector - 02Nos (xxi) Stack top plate -PC- New (12x30 Slt) - 01No (xxii) 25sqmm 300mm elaston C connector (6.4mm) - 0 No
Notes: (a) Batteries shall be located inside trays of MS HRCA sheet, painted with RAL 7040 (window grey colour), (b) Trays shall be mounted on Penguin legs (c) All cell connectors shall be made of lead coated copper busbars (d) All connectors shall be designed for 27A current rating (e) All connectors shall be designed for 3hrs discharge rating
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of electric cable, 3.5 core 240sqmm, 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
S&F in repairs epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/50/5VA for 11kV complete all as specified and as directed
S&F in repairs epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 50/25/5VA for 11kV complete all as specified and as directed
S&F in repairs battery charger 24V 50Hz charging range 6 to 24volt with trickle / boost charging mode with ammeter and voltmeter complete all as specified and as directed
Supply only silica gel in 5/10kg sealed packets complete all as specified
M&L for danger notice plates, for LT of size 25x20cm, made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts including takind down old / damaged notice plates and disposing off complete all as specified and as directed
S&F in position 50mm bore GI tubing, light grade, ISI marked with fittings for cable protection laid in trenches, floors or fixed to walls, poles with and including suitable sized clamps made from FI 40x3mm with all required nuts, bolts, washers, etc. including taking out old / unserviceable tubing and disposing off complete all as specified and as directed
S&F in repairs aluminium thimbles complete all as specified and as directed of the following sizes:
M&L base assembly of suitable size as per existing size and make of VCB after disconnecting, taking out VCB and replacing VCB, reconnecting and testing on installation complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core, 120 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core, 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 120 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 120 to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 240 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F gang operated air break switch from two pole / four pole structure, triple pole, mechanically operated, mounted on suitable insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200A, outdoor type, HT 11kV, with fixed contacts of phosphorous and bronze and a set of dropout HT fuse assembly, fuse carrier fitting, 9 insulator type mounted on MS channel operating rod with pad lock arrangement conforming to relevant IS, including dismantling, taking down and disposing off old / unserviceable air-break switch complete all as specified and as directed
--ditto-- all as per item No. 44 hereinabove but 400A
S&F in repairs IDMT relay with numerical relay for VCB tripping system for E/F (10% to 400% in step of 1%), O/C (1% to 20% in step of 1%), having ability to record 20 to 30 fault records and 200 to 250 events records with modbus protocol for communication operated on 24V DC/110V AC all as per per existing complete all as specified and as directed Note: Existing relays are IDMT electromagnetic type hence any modification in the wiring and panel sheet enclosure shall be done to get system operational. Cost for all such aspects shall be deemed to be included in the quoted rate
Supplying, designing, fabrication and fixing MS trolley suitable for VCB /ACB, fabricated out of MS angle iron pipe and MS sheet to required size as per site having wheels on all four legs including all welding, cutting, bending, locking arrangements, nuts, bolts, washers, etc. taking out and disposing off old / unserviceable trolley complete all as specified and as directed Note: (i) Design and fabrication data shall be in accordance to existing trolley (ii) VCB / ACB shall be pulled out, placed in new trolley and shall be replaced in position including all connecting up (iii) All lifting, loading, unloading, etc. required to replace old trolley shall be deemed to be included in the quoted rate
S&F feeder pillar box of size 1200x1200x1200mm, outdoor type, double door, front & back openable, suitable of 3 phase 415V, fabricated out of 3.15mm thick MS sheet with suitable size of MC & HT 11kV aluminium busbar, fitted with and including HT 11kV base type insulators, provisioning of suitable locking arrangments, duly placed over and including angle iron (50x50x6mm) frame stand grouted in base foundation duly embedded in ground having height 500mm above ground in PCC 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connection with thimbles nuts, bolts, lugs, cable glands, etc. painting all over with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, including suitable danger notice plates on all four sides and dismantling old unserviceable feeder box / panel and disposing off complete all as specified and as directed
S&F single side information board of size 0.9x0.6m, made out of PVC / acrylic sheet with 2mm thick aluminium sheet backing duly inserted in angle iron 35x35x5mm frame allround, duly welded with 2Nos. 40mm OD pipe, heavy duty stainless, 1.8m hgh, with retro-reflective high intensity grade with writing MES/SL No, make/ capacity, date of installlation, SM No, area, etc. grouted in ground with PCC 1:2:4 type C1 including taking out and disposing off old unserviceable information board at any location / position complete all as specified and as directed Notes: (i) Information to be written, font, height of fonts, colour, etc. shall be as directed by the Engineer-in-charge (ii) Retro-reflective tape and sheet shall be as approved by the GE
S&F in repairs on load change over switch 415V 250Amp 4 Pole with front handle operation as per exising make and size complete all as specified and as directed
S&F in repairs on load change over switch 415V 400Amp 4 Pole with front handle operation as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 160Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 250Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
S&F in repairs off load change over switch 415V 400Amp 4 Pole with side handle operation in sheet metal enclosure as per exising make and size complete all as specified and as directed
Supplying, fixing, connecting, testing and commissioning MCCB 125A, FP, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 315A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting complete all as specified and directed
S&F in repairs panel mounting voltmeter 3phase 0-500V digital type in 96x96sqmm display, flush mounted, class1.0 complete all as specified and as dirtected
S&F in repairs panel mounting ampere meter 3phase 400A rating, digital type in 96x96sqmm display, flush mounted, class1.0 complete all as specified and as dirtected
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 40mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications and taking down and disposing off old unserviceable earthings complete all as specified and as directed
Notes: (i) The cost of GI earth continuity conductor with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
R D Bansal
Esha Engineers
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
Raman Electric Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .