Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC KHURDA KHORDHA ODISHA 751015 UDYAM OD 19 0011250 | KHORDHA | ODISHA | 751015 | L1 | Accepted-AOC Qualified in the Lottery | |
| 2 | L2₹13.9 L+₹3.2 L (29.4%)Rejected-AOC SHOP NO 17A CT MARKET SECTOR SEC 06 ROURKELA | L2 | Rejected-AOC Not Qualified in the Lottery | |
| 3 | L2₹13.9 L+₹3.2 L (29.4%)Rejected-AOC AT A 48 NABAKRUSHNA NAGAR PO SONAPARBAT PS TANGARPALI ROURKELA ODISHA 769016 | SUNDARGARH | ODISHA | 769016 | L2 | Rejected-AOC Not Qualified in the Lottery | |
| 4 | L2₹13.9 L+₹3.2 L (29.4%)Rejected-AOC | L2 | Rejected-AOC Not Qualified in the Lottery | |
| 5 | L2₹13.9 L+₹3.2 L (29.4%)Rejected-AOC CHHEND ROURKELA | KENDRAPARA | ODISHA | 754217 | L2 | Rejected-AOC Not Qualified in the Lottery |
Tender Value
₹13.9 L
EMD Value
₹13,900
Closing Date
3 Jul 2026, 9:30 amClosed
Divisional Officer
Office of Superintending Engineer Rourkela R and B division
Provision of DG Panel, Battery for Online UPS, installation of solar Panel stand, LT line interposing pole and internal Electrical fitting at Govt. ITI Rourkela as per Lr. 4473 Dt. 31-03-2026 of DTET Buildings.
2026_EICCL_132676_1
NIT 08 of 2026-27
Open Tender
Electrical Works
Percentage
30 days
Sundergarh
2 documents required · 2 mandatory
₹6,000
₹13,900
Yes
13 Oct 2026
23 Jun 2026
4 Jul 2026
23 Jun 2026
3 Jul 2026
23 Jun 2026
23 Jun 2026 - 30 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply ,Installation,testing & commissioning of LTDB plinth mounted both side openable made out of CR sheet of 16 SWG and boarder angle frame to provide above panel with proper space,hinged door must be painted one coat of powder coating and two coat of enamel grey paint including wiring with appropriate size FRLS PVC single core multistrand copper cable,cable alley and connector with following arrangement.having hinged door and compartmental arrangement for each equipment & busbar chamber on the top of the panel running horizontally; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused and complete in all respect as per the direction of Engineer-in-charge/ Owner . (Depth 15 cm to 30 cm) size (36 x 36 x11)=(0.9 x 0.9) sq.mtr | 1 | nos | 22,680 | ₹22,680 |
| 2 | S/F of 630A ,50KA MCCB -1 NO. | 1 | set | 71,995 | ₹71,995 |
| 3 | S/F of 250A 36KA-3 N0S | 3 | set | 45,280 | ₹1,35,840 |
| 4 | S/F of 12V 42AH on line UPS Battery(Make- Amaron/Quanta/Excide) | 1 | nos | 5,330 | ₹5,330 |
| 5 | Supply,erection and transportation of 9 mtr PSC Pole | 2 | nos | 5,682 | ₹11,364 |
| 6 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty flexible conduit (POINT EXTRA SUBMAIN/INVERTER)(2X1.5+1X1.5) Internal work Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZH insulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, in recessed PVC conduit Heavy duty FRLS of mentioned size (AKG/Anchor/Kinjal or equievalant ISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials | 60 | mtr | 159 | ₹9,540 |
| 7 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG) (2X2.5+1X1.5) | 150 | mtr | 173 | ₹25,950 |
| 8 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit . (2X4+1X1.5) (AC POINT AND 16A SOCKET) | 200 | mtr | 191 | ₹38,200 |
| 9 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5) | 50 | mtr | 222 | ₹11,100 |
| 10 | LT Panel: Supply ,Installation,testing & commissioning of main control panel plinth mounted both side openable made out of CR sheet of 16 SWG and boarder angle frame to provide above panel with proper space,hinged door must be painted one coat of powder coating and two coat of enamel grey paint including wiring with appropriate size FRLS PVC single core multistrand copper cable,cable alley and connector with following arrangement.(Depth 15 cm to 30 cm) size (36'' x 36''x11'')=(0.9 x 0.9) sq.mtr DIGITAL INSTRUMENT:- Voltmeter, Ameter,selector switch& Indicating lamp (R-Y-B) digital,CT coil up to 400 Amp 250 Amp 4 pole MCCB ,36KA(L&T/Havells) 315 Amp TPN Changeover switch in open execution (Havells/L&T) 63 Amp 4 pole MCCB , 36 KA(L&T/Havells) -10 63 Amp 4P MCB-4No, 32A DP MCB -03Nos (Havells/HPL/L&T) | 1 | set | 2,09,008 | ₹2,09,008 |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_597514.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.66 MB
Tendernotice_2.pdf
PDF • 1.31 MB
BOQ_597514.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .