Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 CrAccepted-AOC GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹13.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹14.3 CrRejected-Finance | ₹14.3 Cr | L2 | Rejected-Finance Rejected
Being L2 |
| 3 | L3₹14.3 CrRejected-Finance | ₹14.3 Cr | L3 | Rejected-Finance Rejected
Being L3 |
| 4 | L4₹14.5 CrRejected-Finance | ₹14.5 Cr | L4 | Rejected-Finance Rejected
Being L4 |
| 5 | L5₹14.7 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹14.7 Cr | L5 | Rejected-Finance Rejected
Being L5 |
Tender Value
₹13.7 Cr
EMD Value
₹10.1 L
Closing Date
17 Mar 2020, 6:00 pmClosed
CE NW Kochi
Kataribagh, Naval Base, Kochi-04
PROVISION OF CERTAIN DEFICIENT MCPOs/CPO MD ACCN FOR SAILORS AT KOCHI
2019_MES_310863_1
890926
Open Tender
Civil Works
750 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹3,000
GE (P) (NW) Kochi
₹10.1 L
Yes
30 Apr 2020
31 Dec 2019
19 Mar 2020
1 Jan 2020
17 Mar 2020
2 Mar 2020
1 Jan 2020 - 13 Jan 2020
Amount
LIST OF WORKS
Schedule A Part I( to Part XI)
Total amount of Sch 'A' part-I (Buildings & Structures)
Total amount of Sch 'A' part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' part-III (Internal Electric Supply)
Total amount of Sch 'A' part-IV (Internal Water Supply)
Total amount of Sch 'A' part-V (External Electric Supply)
Total amount of Sch 'A' part-VI (Externall Water Supply)
Total amount of Sch 'A' part-VII ( Fire Fighting)
Total amount of Sch 'A' part-VIII (Lightening Protection)
Total amount of Sch 'A' part-IX(Area Drinage)
Total amount of Sch 'A' part-X (Road/Path/Hardstanding)
Total amount of Sch 'A' part-XI(Sewage Disposal)
Total amount of Sch 'A' part-XII(Stand by DG Set)
Sch 'A' Part- XIII (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 750mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items . (ii) The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test.
RCC with ready mix concrete(RMC) M30 as per IS 456 with using 20mm graded stone aggregate in cast in pile cap, grade beam/tie beam/under reamed pile complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 10mm dia as in stirups for pile caps and gared beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 10mm dia conforrming to IS - 1786 as in Helical for piles cut to length, bent to shape required and binding with 0.90 m dia MS annealed wire or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over up to and including 10mm dia as in Ring/Stiffener for piles all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed..
Providing testing equipment & load and testing of 750mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 750mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m deep or not exceeding 3.0m deep area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of excavated soil to a distance exceeding 1.5 KM but not exceeding 5.0 KM and deposited whereever directed at a level not exc 1.5 m above starting point all as specified and directed..
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified and shown on drawings.
INTERNAL ELECTRIFICATION:Ceiling fan 1200 mm sweep copper wound having minimum 5 star rating , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan. Note : The rate included the rate of suitable down rod of any length. Where ceiling height is high, bottom height of ceiling fan will be decided bythe Engr in charge.
Ceiling Fan 5 speed step regulator, 120W-2 module 230 Volts,50Hz, ISI marked with valied CML No complete all as specified and as directed
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound complete all as specified and directed at site.
LED Tube light 1X22 Watt universal battern type with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting from ceiling rose to fitting. copmplete all as specified and directed at site Note: (a) Fitting: Havells Cat Part No REGALBATTERN8UPTOP1X22WWSSBSWH or equivalent make of CG/Philips. (b) Lamp: Havells Cat Part No CRYSTAL1213T8DSTL20LED865SGLASS or equivalent make of CG/Philips.
Sleek LED mirror light 1X10 Watt with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting. copmplete all as specified and directed at site Note:- Fitting WITH LAMP: Havells Cat Part No LUMILINEPLUSNSI0WLED865SPCSS or equivalent make of CG/Philips.
Decorative wall light fitting with and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor color of sheve matching to fitting and connecting from ceiling rose to fitting. copmplete all as specified and directed at site Note: (a) Fitting : Havells Cat Part No LHFHCHEITLIW020 or equivalent make of CG/Philips. (b) Lamp: Havells Cat Part No LHLDEUHEML8R009 or equivalent make of CG/Philips.
Street light new generation energy saving and environmental friendly long life LED streetlight made of pressure die cast alluminium housing with hogh power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1sqmm PVC insulated multistranded copper cunductor wire conecting pvc terminal/ Ceiling rose up to fitting. (Make Havells 25W LED IP66 security light Model No.ENDURAPEARL25WLED757SASYTOPCor equivalent make of CG/Philips).
MCB SPN 40-63 Amps 10 kA with chareterestic curve "C" Curve C curve complete all specified and as directed
MCB SPN 6-32 Amps 10 kA with chareterestic curve "C" Curve C curve complete all specified and as directed
MCB SP 6-32 Amps 10 kA with chareterestic curve "C" Curve C curve complete all specified and as directed
TV Co - axial socket 1 module with base pate and outter cover complete allas specified and directed.
Telephone socket RJ 11 with shutter 1 Module with base pate and outter cover complete allas specified and directed.
GI flush box 2 module complete all as specified and as directed
Internal Water Supply :- Angular stop cock with wall flange, chromium plated, cast copper alloy, screwed down, screwed for iron pipe 15 mm dia bore. Make Jaquar Code No CQT-23059 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Stop cock with wall flangeceramic disc cartridge with pain knob , screwed down, screwed for iron pipe 25 mm dia bore. Make Jaquar Code No CQT-24081 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Bip tap with wall flange complete of make Jaguar Cat part No CQT-23047 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Stop cock long body combination of exposed part kit of consealed stop cock with fitting sleave, operating knob, adjustable wall flange and regular body consealed stop cock suitable for 15mm pipe line with protection cap. Complete of make Jaguar cat part No CQT-23082K and ALD083 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Hot water braided pipe 450mm long with two 15mm nuts and rubber washer without nipple, Complete of make Jaguar cat part No ALD805B or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Health faucet/ hand shower with 8 mm dia, wall hook and easy flexible tube in crome finish1.5m long with nuts. Complete of make Jaguar cat part No ALD573 and SHA571 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Over head shower rose 100mm dia round shape single flow ABS body chrome plated wirh grey face plate and Rubi/ cleaning system and shower arm casted120mmlongheavy body round shape for wall mounted shower with wall flange complete of make Jaguar cat part No OHS1989 and SHA-487 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
2 way wall mixer tap wall mounted 2 in 1 system with provision for over head shower with 115mm long bend pipe on upper side connecting legs & wall flanges, complete of make Jaguar Cat part No CQT 23073UPR or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
CPVC pipe, Schedule 80 & Plain CPVC Schedule 80 fittings 100 mm Inner diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed.
CPVC pipe, Schedule 80 & Plain CPVC Schedule 80 fittings 75 mm Inner diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed.
CPVC pipe, Schedule 80 & Plain CPVC Schedule 80 fittings 62.5 mm outer diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed.
CPVC pipe, SDR-11 & Plain CPVC SDR 11 fittings 50 mm outer diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed. Make : Astral / Reliance
CPVC pipe, SDR-11 & Plain CPVC SDR 11 fittings 40 mm outer diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed. Make : Astral / Reliance
CPVC pipe, SDR-11 & Plain CPVC SDR 11 fittings 32 mm outer diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed. Make : Astral / Reliance
CPVC pipe, SDR-11 & Plain CPVC SDR 11 fittings 20 mm outer diameter on wall / floor / ceiling and making good the disturbed surface all as specified and directed. Make : Astral / Reliance
External Electric Supply:- XLPE LT cable insulated screened PVC bedded, galvanised steel strip or wire armoured, electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor cables of following sizes fixed in wall/ roof or laying in trenches etc, complete all as specified and as directed.
150 sqmm 3.5 core
95 sqmm 3.5 core
10 sqmm 2 core
35 sqmm 3.5 core
Outdoor type Ring main Unit 11 KV, 630 Amps, 20 KA, Motor operated compact, Indoor, both isde Extensible, Non drawn out ype +CCV+(02 Nos Load break Switch outgoing and 01 No fixed type motor operated Vacuum Circuit breaker (VCB) SAFEPLUS compact gas insulated Ring Main Unit, All live Parts enclosed in a robotically welded stainless steel tank IP 67 class of protection with Battery and Battery charger, make and model matching with the existing switchgear including extension of busbar of existing VCB/RMU, including connection and testing complete all as directed at site.
Compact substation with and including following plants of following ratings. (A) 11 KV 630 Amps load break switch with 400 amps DO set and earth switch complete with all fixing arrangements as per manufacturers design and latest IS code. (B) Transformer step down, Indoor type, copper wound, 11KV on HT side and 433 Volts on LT side at no load, 3 phase, 4 wire, 50 c/s AC supply of 100 KVA, Dry type, delta connected on HT side and star connected on LT side, corresponding to vector group DY-11 with neutral brought out separately for earthing, off load, changing tap arrangements up to +/- 2.5%. The transformer shall be resin cast dry type transformer complete with all accessories for compact /package type substation with standard fittings confirming to prevailing IS and its amendments, all as specified. (All steel work for staging and poles shall be measured and paid for separately). (C) Factory made and CPRI tested in door type Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 400 Amps for phases and 400 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal as required using angle iron size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back open able type adequate space all around
accessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings accessories. (D) OUTINGS (a) MCCB 415 Volts, 160 Amp rating, 4 Pole microprocessor based control (Service Breaking Capacity 16 KA 1 No. (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs. (F) NOTE: (1) The entire unit of compact substation with indoor HT breaker, transformer, capacitor panel and LT panel shall be CPRI approved. 2) The cost of testing and transporting from factory to (CPRI lab and from CPRI lab to proposed site is deemed to be included in unit rate. (3) The contractor shall submit foundation/ plinth drawing from the manufacturers for obtaining approval be for erecting of compact/ package substation. (4) Cost of plinth as per manufacturer’s directions shell be deemed to be included in unit rate.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded conductor, 11000 volts grade of size 3 core 185 sqmm
Cable end termination outdoor heat shrink type complete with jointing materials and accessories suitable for XLPE 11 KV grade armoured aluminium conductor of size 3 core 185 sqmm
Cable end termination indoor heat shrink type complete with jointing materials and accessories suitable for XLPE 11 KV grade armoured aluminium conductor of size 3 core 185 sqmm
Factory made CPRI approved outdoor type hood/ canopy on top pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 250 Amps for phases and 250 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work duly painted with 2 coats of synthetic enamel paint of japan black color over a coat of red oxide primer. the panel shall be both front and back openable type, adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
INCOMINGS:- (a) MCCB 125 Amp ,4 Pole,415 Volts 25 KA- 01 No. OUTGOING:- (a) MCCB 63Amp, 4 Pole, 16 KA- 03 Nos(one spare), (b) LED Indication lamp RYB-01 sets, (c ) Digita; multi meter with all accessories - 01 (d) Digital Ammeter (0-100A) including CTs with ratio 100/5A - 03 Set
Factory made CPRI approved indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work duly painted with 2 coats of synthetic enamel paint of japan black color over a coat of red oxide primer . the panel shall be both front and back openable type, adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
INCOMINGS:- MCCB 63 Amps 4 pole 16 KA 415 Volt - 01 No OUT GOING:-(a) MCCB 40 Amps 4 pole 16 KA-03 Nos (b) MCCB 32 Amps 4 Pole 16 KA, 415 Volt (Spare) (c) MCB 40 Amp TPN 10 KA -01 (d) LED indication lamp RYB-01 sets (e) Digital multi meter with all accessories 01 (f) Digital Ammeter (0-100A) including CTs with ratio 100/5 A - 03 Set
Factory made CPRI approved indoor type wall mounted. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process, the panel shall be both front openable type, adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
INCOMINGS (a) MCCB 415 Volts,100 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 18 KA 1 Nos. b) Digital volt meter 0-500 Volts-01 (c) (c) Digital Ampere meter 0-300 Amps with and including CTs-01 No. OUTGOING (a) RCCB 40A, 30mA TPN 4 module - 01 No. (b) Internal wiring of panel with stranded copper cable of suitable size. (c) Neon phase indicating lamp(Set of three)-02 Set. (d) All standard accssories which are left out herein above be cosiderd to make the panel functional. (e) Stenceling of pannel board including marking of distribuitions
Factory made CPRI approved indoor type wall mounted. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process, the panel shall be both front openable type, adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-
INCOMINGS (a) MCCB 415 Volts,63Amp , rating 4 Pole, Thermal Magnetic release (Service Breaking Capacity 18 KA)- 01 Nos. b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs-01 No OUTGOING (a) MCB 32 Amp TP 10 KA - 02 Nos (a) MCB 10 Amp TP 10 KA - 03 Nos. (b) Internal wiring of panel with stranded copper cable of suitable size. (c) Neon phase indicating lamp(Set of three)-02 Set (d) All standard accssories which are left out herein above be cosiderd to make the panel functional. (e) Stenceling of pannel board including marking of distribuitions (f) space for providing starter for pump and motor-02 Nos
LED street/Security light fittings, new generation energy saving and environmental friendly long life versatile die-cast aluminium IP 66 luminaire with high power LEDs 70/75 watts heat resistant toughened glass with frame including suitable size copper multistranded cable for connection from junction box at the bottom of the pole, suitable size GI tubes maximum up to 1.5 meter and all as directed.
Steel tubular swaged pole type 410 SP- 31, 9 meter long complete with base plate, finial and swan neck including foundation and all connected earth works complete all as directed.
Thermoplastic junction boxes IP 55 with metric knockouts for cable entry including four terminals suitable for LT cable up to the size 4 core 50 sqmm and the size of the box is 210mm x 310 mm
Dismantling existing feeder pillar of any type/ size without damaging by disconnecting all cables and handover to GE (NS) Kochi.
Taking out existing old UG cables of sizes upto 70 Sqmm including all connected earth works
Taking out existing UG cables of sizes above 70 Sqmm including all connected earth works
External Water Supply:- Valve chamber 900X900X900 mm size internally built with brick work in CM 1:6 plastering complete with CM 1:4 including necessary earth work, PCC 1:4:8, 100 mm thick as in foundation concrete including provision of cast iron hinged cover with using 2mm thick steel with "FH" empossed and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed
Supplying and laying in trenches centrifugally cast (spun) ductile iron pipes of 150mm dia including specials suitable for pressurized water delivery with spigot & socket end, class 'K-9' conforming to IS 8329/2000 (latest version) - blast furnace slag cement with portland cement properties suitable for (push on) rubber gasket jointing with inside cement mortar lining and black bitumen external coating, duly ISI marked in any length including testing and commissioning all as specified and directed.
CPVC pipes with CPVC schedule 80 pipes & plain CPVC schedule 80 fittings in trenches or laying in floors of inner diameter 75 mm including all fittings complete all as specified.
CPVC pipes with CPVC schedule 80 pipes & plain CPVC schedule 80 fittings in trenches or laying in floors of inner diameter 62.5 mm including all fittings complete all as specified.
CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches/walls all as specified of size 50mm outer dia complete all as specified and directed.
CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches/walls all as specified of size 40mm outer dia complete all as specified and directed.
CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches/walls all as specified of size 32mm outer dia complete all as specified and directed.
CPVC pipes SDR 11 and plain CPVC SDR 11 fittings in trenches/walls all as specified of size 25mm outer dia complete all as specified and directed.
Taking up ductile iron/CI water mains upto 150mm bore including all fittings with spigot and socket ends and, lead joints including burning out joint complete all as specified and directed. Note: Lead joints retrieved shall be reused for rejoining of pipes.
Laying only DI/CI pipes from various stacks of pipes are indicated at site to required site/ along the trenches, complete all as directed at site. Note: Cost of equipments including specials for handling and transportion shall be deemed to be included in unit rate.
Lead wool joint complete all as specified and directed.
Electric driven Multistage mono block centrifugal pump sets set with bronze impeller of capable of delivering 10 LPS at 40 Meter head coupled with three phase 415 volt 3000 RPM not less than 15 HP complete of cat Part No KDS 1360* Suc. 65mmX Del 50 mm of Make Kirloskar Brothers. The work also includes the followings:- (a)M&L for Lowering of GI suction pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the sucttion of pumps from foot valve at suction pit to pumps (b)M&L for of GI dilvery pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the pumps from Pump butterfly valve and from butterfly valve to NRV. (c) M&L for MS 'C' chanel for clamp made out of MS flat 100x12 mm for lowering/installation of pump set complete- 02 Nos (c) Supplying, fixing and testing of Brass reflux valve (NRV) of suitable dia flanged joint complete with nuts, bolts and washers complete all as specified. (d) Supply and fixing of slim seal butterfly valve with iron wheel head both ends flanged for iron pipe and fixed complete with nuts, bolts and washers complete all as specified. (e) Pressure gauge diaphragm type up to 50 Kg/Cm2-1 No. (f) M&L for air release valve 15mm
Car door with 1 hours fire rating and landing door 2 hours fire rating, 900 mm x 2000 mm (lift car clear entrance opening), Car size (WxDxH)- 2000 mm (W) x 1100 mm (D) x 2200 mm (H), Minimum clear car height below false ceiling to be 2200 mm, Aluminium Sill, fire man safty switch , Stainless steel hair line finish Car operating panel inside car with floor destination buttons along with door open/close, emergency alarm, press and speak type intercom and attendant switch to be provided with 16 segment LED/Dot Matrix Dynamic Car Direction display and Digital position indicatiors,Stainless steel hair line finish for narrow door frames or as approved. (c) PARAMETERS COMMON TO LIFT : - 3 phase, 415 V/220V, 50 Hz Power Supply, Acceptable Voltage Fluctuation +10 to -10% , Rate of acceleration/Deceleration 0.6-1.5 M/S2 , Jerk 0.7-1.6 (m/Sec3) , Horizontal vibration - a(xmaxPtP) & a(ymaxPtP)- Max 20mg, a(xA95) & a(yA95) - Max 15mg, Vertical vibration: - a(xmaxPtP) & a(ymaxPtP)-Max 20mg, a(xA95) & a(yA95) - Max 15 mg, Airborne noise level in Car (ISO 18738:2003)- L (Aeq) - Max 48 dB (A), L (P)- Max 57 dB(A), Airborne noise level at landing door- Door movement noise L (p_door)- Max 52 dB (A), Pass by noise- L(p_landing)- Max 48dB(A), Stopping accuracy & Leveling Accuaracy - +/- 3 mm to +/- 5mm, Direct drive doors with PM motor and closed loop VVVF door control,Car panel and door panel thickness- At least 1.50 mm.
(d) FIXTURES/SIGNALS INSIDE CAR (Stainless steel car operating panel with following buttons and indications) : - Door open/door close buttons with symbol markings. Door hold button for service lifts, ARD operation audio/Visual indication in car,Emergency alarm button with bell symbol and the same should be at distinct distance from the call buttons. Emergency alarm button to be located along-with door open and close buttons at a height of 900 + 10 mm from floor level. Yellow pictogram to be provided, Alarm sound shall be siren type audible from at least 50 meters from the ground floor landing, Ventilation fan ON/OFF switch with auto switch off feature after 120 seconds lift at idle condition, Two position key operated attendant switch for with/without attendant operation, LED illuminated tactile braille buttons of micro motion type corresponding to the floors served. The push buttons to be of robust SS vandal resistant type, Three-way built in press and speak type with 1 master and 2 slave units in security room/control room. Additionally, wiring provision for connecting building EPABX with car phone with rechargeable batteries,16 segment, LED/Dot matrix car direction display and digital position indicators located at a conspicuous height above car door for passenger Lift (Bidder to provide inputs on car displays),
(d) Emergency light with rechargeable sealed maintenance free battery with 30minute backup, Emergency alarm with rechargeable sealed maintenance free batteries rated for 30minute backup, Audio/visual over load warning indicator, Floor position voice announcement with back ground music. (e) LANDING INDICATORS : - Two landing buttons with position indicator in all floor,Chime on car (f) PROVN OF HANDICAP FRIENDLY FEATURES IN PASSENGER LIFTS: - Mirror, SS hand rail on rear side only, Braille marking buttons on car operating panel and landing push buttons have braille inscriptions, Voice announcements to announce the floor position, Multi beam infrared protection device to reverse the closing door in case of slight obstruction in the door way. (g) SAFETY FEATURES AND OTHER INCLUSIONS : - Fire man’s switch for the lifts at ground floor level. The lifts to have fire man mode – stage 1 and fire lift to be with stage 1 and 2, Multi beam infrared protection device to reverse the closing door in case of slight obstruction in the door way, Automatic phase reversal device, Overload, non-start and overload protection device, Spring buffers, Electro mechanical type safety governor for car, DO’s and Don’ts with emergency contact numbers engraved on a SS face plate displayed in the car as for safety instructions, Terminal and final limit switch provn for Over travel protection, Controller/driver/motor protection -
Trip device for over current, under voltage and over voltage than the rated capacity +/- 10%, Motor over load/over torque, Instantaneous over current, Ground fault, Under voltage, Over voltage – 3 phase, Output & input phase loss, Phase reversal, Output short circuit , Over speed, Spike and surges. ARD battery operated with and including of any maintenance free batteries of suitable capacity and battery charger with optimum direction in start operation and requiring no human intervention, rescue clearing, power/system failure with latest IGBT power devices, Landing door to have 2 hour fire resistance rating. Car doors as per requirements, Intercom connection in Car and control room and also in security room., Provision of suitable cables along the travelling cable for fire detector and music inside the car, Provn of one car blower to be connected through power supply, Full height fascia plates and sill angles to be provided. Apron of min height 750 m to be provided at car side, epoxy coated MS pit ladder of height more than lift pit to be provided and securely fastened inside the pit, System memory should be retained in the event of power failure or disturbance. Lifts should not go in to correction mode or correction run to the lowest floor/highest floor to update its position and memory,Safe landing feature-
If a car has stopped between floors due to some equipment malfunction, the controller checks the cause, and if it is considered safe to move the car, the car will move to the nearest floor at low speed and the door will open. Ascending over speed protection device, Unintended car movement protection device,Earth quake operation if required under lift act for Kochi region- Seismic sensors and auto isolation arrangement for safety & Counter weight derailment device or displacement switches to be provided. Other functions – anti nuisance, car call cancellation, next landing, bye pass, self levelling, door time adjustment, independent operation and return operation. Misc - Elevator (lift) related civil work and steel work required for installation of lift, Note:- (1) The work of lift design, supply installation testing and commissioning will be executed by the lift manufacturers as per the makes mentioned above in BOQ.The manufacturers of these lifts be refered as OEM for lifts only in this tender. (2) The OEM or the agency authorised to carry out maintenance of lifts by OEM as per Sch 'A' provisions and relevant items of BOQ will be permitted to undertake maintenance of lifts.
Fire Fighting :- Steel water tubing heavy duty galvanised ISI marked of 100mm bore with all fittings of with flanged ends fixed on walls/ floors/ roof etc including fixing with clamps gasket, GI nuts and bolts etc on wall for the wet riser including painting with approved synthetic enamel paint all as directed.
Steel water tubing heavy duty galvanised ISI marked of 150mm bore with all fittings of with flanged ends fixed on walls/ floors/ roof etc including fixing with clamps gasket, GI nuts and bolts etc on wall for the wet riser including painting with approved synthetic enamel paint all as directed.
Hose reel swinging wall mounted type comprising rubber hose 20mm dia 30m long high pressure double braided bearing IS-444 type 'A' 5 mm bore PVC shut off nozzle and 25mm gunmetal inlet valve conforming to relevant IS and connected to wet riser complete all as specified and as directed. Make Minimax/Mahavir/Newage
Landing valve (internal hydrant) single headed gunmetal bearing ISI mark grade 63 mm female instantaneous outlet complete with PVC blank cap and chain and having suitable flanges for 100 mm dia wet riser complete confirming to IS 5290-1993 all as specified and as directed. Make Newage/ Winco/ Tulsi/ Aaag
Gun metal branch pipe 63mm dia male instantaneous inlet threaded outlet fitted with hexagonal based nozzle of 12.5/15 mm dia heavy duty conforming to IS-903-1993 complete all as specified and as directed. Make Newage /Winco/ Tulsi/ Aaag
Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard
63 mm dia 15 meter long hose conforming to IS 636:1988 complete with male and female coupling conforming to IS 903:1993
Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
100mm bore conforming to IS 13095, ISI marked complete all as specified and directed at site
Flanged sluice valve, class PN 1.6, 100mm dia with brass spindle and CI operating wheel, ISI marked and complete all as directed.
Flanged sluice valve, class PN 1.6, 150mm dia dia with brass spindle and CI operating wheel, ISI marked and complete all as directed.
100mm dia valve reflux,ISI marked, with bypass arrangement complete all as specified and directed.
150mm dia valve reflux, with bypass arrangement complete all as specified and directed.
Inteliigent addressable manual call point with inbuilt turbo Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required, duly approved by EN54/LPCB/VDS/FM
2 x 1.5 sq.mm Copper armoured FRLS cable with accessories including glanding complete all as specified and directed.
Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia.
Networkable 2Loop Micro processor based 2 wire fault tolerant loop with optional redunadant network module ,each loop shall have the cpability of connecting 126devices.The fire alarm control panel shall have built in degarde mode function.The panel should have inbuilt TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The Panel Shall have 99 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators.The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications and Duly Approved by EN54/LPCB/VDS/FM
Fire Alarm Sounders/Sirens Electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5m with sound output variation of +5 db 500m range
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM
Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12717 :1989 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz, 36 Mtr head discharge 900 LPM.
Factory made and CPRI tested outdoor type Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 100 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 40 x 40 x 5 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties. (a) MCCB 4P 40 Amps 4 pole with thrmal mangnetic relay, service breaking capacity 10kA as incoming -1 No (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs-01 No (d) MCB TPN 32 Amps 4 pole with service breaking capacity 10kA as outgoing -2 No (e) star delta starter suitable for booster pumps here in above (f) Phase indicating lamps R, Y, B - 1 Set (LED type)
AVIATION OBSTRUCTION LIGHT:- Supply and fix aviation obstruction light LED type including necessary cabling all as specified and directed.(Make Bajaj Cat No. BGAV 302 LED) or equivalent makes in CG / Philips
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured power cable (Heavy duty) 1100 V grade with stranded aluminium conductor of size 2 core 10 Sqmm on poles /walls as cable for aviation obstruction light all as specified and directed.
MCB DB SP 2 way single phase 240 volt without bus bar complete all as specified and directed.
6 Amps SPN MCB complete all as specified and directed.
Stand by DG set :- Static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set Canopy type capable of delivering 32KW/ 40 KVA, Air cooled cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Kochi. (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , CRDI ,cylinders as per manufacturers guideline ,four stroke, confirming to ISO 3046/BS 5514, aircooled cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 32KW/ 40 KVA at outdoor atmospheric conditions at Kochi. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/ fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . (ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 32 KW/ 40 KVA Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
(v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vi) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M (vii) External/ internal cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. Note:- (i) First filling of lubricants/ engine oil/ diesel for 10% overloading for one hour in twelve hours duration by salt water load test or artificial load testing run deemed to be included in the rate quoted for the item. (ii) Necessary RCC and PCC foundation alongwith one meter plinth protection including connected earth work for installation of DG set shall be provideed as per manufacturer's instructions
and cost deemed to be included in the rate quoted for the same. (iii) Necessary 10% overload test shall be carried out in the presence of the Engr-in-Charge or an testing officer nominated by the Accepting Officer.
Wall mounted LED EXIT signage luminaire, lift up from main supply with a rechargable Ni-Cd battery capable of emergency backup up to five hours make Crompton Greeves Cat No LSSRSW or equivalent in Bajaj/Philips
Storage type water heater (geyser) 25 ltr capacity, AC, 230 V having minimum 5- star rating with outer body made out of rust proof ABS material with PUF insulation, inner tank, made out of high quality steel with enamel coating suitable for multi-storeyed building with working pressure not less than 8 KG per cm2 with all safety devices.
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of electrically operated gearless passenger lift through OEM for 884 Kg capacity lift to serve ground plus four upper floors (G+4) all as mentioned in relavent items of this BOQ complete all as specified and as directed for First year after expiry of defects liability period.
All as per item No.143 here in before but for Second year after expiry of defects liability period.
All as per item No.143 here in before but for Third year after expiry of defects liability period.
PPJOHN
VARAHA INFRA LIMITED
Hemant Construction Co.
Mecone Construction Contractors
UBC Engineers Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid