Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 139 B B SEN ROAD CHANDANNAGAR HOOGHLY WEST BENGAL 712136 | CHANDANNAGAR | HOOGHLY | WEST BENGAL | 712136 | ₹1.4 Cr | L1 | Accepted-AOC ACCEPTED AOC |
| 2 | L2₹1.4 Cr+₹2.2 L (1.52%)Rejected-Finance | ₹1.4 Cr+₹2.2 L (1.52%) | L2 | Rejected-Finance Quoted Higher Rate |
| 3 | L3₹1.5 Cr+₹4.1 L (2.91%)Rejected-Finance KREENG SUDIN SHOP NO GH GROUND FLOOR B B ROY LANE COOK S COMPOUND PURULIA PIN 723102 | PURULIA | PURULIA | WEST BENGAL | 723102 | ₹1.5 Cr+₹4.1 L (2.91%) | L3 | Rejected-Finance Quoted Higher Rate |
| 4 | Rejected-Technical MANBAZAR NAMOPARA | MANBAZAR | PURULIA | WEST BENGAL | 723131 | - | - | Rejected-Technical Due to Affidavit -X not in order |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
24 Jan 2026, 10:00 amClosed
Sr. SE,WC,SS,P.W.Dte.
Office of the Sr. SE,WC,SS,P.W.Dte, Suryanagar, Jagatberh, Burdwan
Construction of Latapara Primary Health Centre (PHC) at Bandwan Block in the district of Purulia under XV-FC-HG for FY 2025-2026. (2nd_Call)
2025_WBPWD_980034_1
WBPWD/SS/SRSE/WC/NIT-06-2nd-Cl
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
270 days
Latapara PHC
Please refer Tender documents.
4 documents required · 4 mandatory
₹2.7 L
Yes
Office of the Sr. SE,WC,SS,P.W.Dte.
27 Feb 2026
26 Dec 2025
27 Jan 2026
29 Dec 2025
24 Jan 2026
3 Jan 2026
31 Dec 2025
STRUCTURAL WORKS Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
d) Add extra for excavation in morum soil .
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(B) Do - by fine sand
Pre-Constructional Anti-termite measures: (c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
Post Constructional Measures : (b) Anti-termite treatment to the outside of foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight, drilling 12mm. dia holes in concrete or masonry apron at an interval of 300mm. to a depth, of 300mm or more as close to the plinth wall as possible and the chemical emulsion pumped into those holes to soak the soil below at a rate of 2.25 litres per linear metre complete as per specification laid down in para 4.3.1.1 of Code I.S.-6313 (Part-III)-1981.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
First Floor
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety Ground Floor
First Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel JSW/JSPL/SHYAM Ground Floor
First Floor
Labour for Chipping of concrete surface before taking up Plastering work.
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor
First Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 1:6 cement mortar (b) 20 mm thick plaster Ground floor
First Floor
(i) With 1:6 cement mortar (b) 20 mm thick plaster Ground floor
First Floor
(ii) With 1:4 cement mortar (c) 10 mm thick plaster.Ground floor
First Floor
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. Ground Floor
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (GroupBIa) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with WaterAbsorption (av.) ≤ 0.08%] infloor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using [email protected]./sqmat the back sideof the tiles and laid over the mortar bed sing 0.2kg/sqm of White ement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost ofmaterials, Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) Ground floor
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N Ground floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i)Coloured decorative Ground floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground Floor
First Floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Ground Floor
First Floor
Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP anel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (a) Slab Thickness 20 to 25 mm
Supplying, fitting & fixing granite slab 15 mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm(avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40 Kg per Square meter before placing of granite and jointed with white cement slurry @2.0 Kg pers quaremeter with necessary pigments and complete as per direction of Engineer-in-charge includingcost of curing and roughening of concrete surface complete. (b) Area of each Granite slab 0.6 to 1.0 Square meter.Ground Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local. Ground Floor
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (b) 25mm thick shutters (single leaf)
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor.(i) 32 mm thick Ground Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately (a) 40mm X 6mm, 250mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:
Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.
Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units
(v ) Louvered window
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.ii) 4mm thick coloured / tinted / smoke glass.
viii) 8mm thick coloured / tinted / smoke glass.
Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesn't exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturer's specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)
Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:
Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in- Charge fitted and fixed complete including all incidental charges.
ii) Godrej Hydraulic door closer fitted and fixed complete.
Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(vii) 225mm long x 10mm dia.
(iv) 150mm long x 10mm dia.
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(b) 250 mm long.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.Ground Floor
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150 mm apart complete in all respect as per design including cost of all labour and materials.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Ground Floor
(ii) Grill weighing above 16 Kg./sq.mtr and above Ground Floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. (A) In 10-12 Micron thickness Annodizing film I) Natural white For 2-Track window :
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing film I) Natural white i) Top, bottom and side member.
ii) Louvered Section.
iii) Cleat angle ( Non-annodized).
g) Fixed glazing i)Top, bottom and side member.
ii) Mulion
iii) Glazing clip.
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board,
b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm (unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.0 Kg per Sq.M]
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (a) 300 mm long
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-(iv) fixed glazing
v ) Louvered window.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) (iv) Two coats (with any shade except white)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (b) On steel or other metal surface : With super gloss (hi-gloss) (iv) Two coats (with any shade except white)
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coat Ground floor
First Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat) b) Premium 100% Acrylic EmulsionGround Floor
First Floor
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) Two Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (iii)160 mm. Dia.
B) UPVC Fittings: a)Plain Tee (iii) 160 mm. Dia.
B) UPVC Fittings: c) Bend 87.5 degree (iii) 160 mm. Dia
B) UPVC Fittings: d) Shoe (iiI) 160 mm. Dia.
Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge. All floor
2 H.P. SUBMERCIBLE PUMP Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) a) For Exposed Work PVC Pipes 32 mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia) 20 mm
PVC Pipes (Dia) 32 mm
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (vi) 32 mm dia
Supplying, fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (iv) 32 mm dia
Supplying, fitting and fixing check valve (vertical) G.M. tested to 21 kg per sq. cm. (iv) 32 mm dia
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).) (A) P.V.C. Pipes (Dia)>>200mm.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
SANITARY AND PLUMBING WORKS Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992 (It. No.-23, P-68) A) i) single socketed 3 mtr length -- (Soil Pipe) b)110 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (PAGE NO- 68, ITEM NO- 23) (A) (i) Single Socketed 3 Meter Length (waste pipe) a) 75 mm
(ii) Plain Tee(a) 75 mm
iii) Plain Y(a) 75 mm
iv) Bend 87.5º(a) 75 mm
xxxiv) Multi Floor Trap without Top tile & Strainer 75 mm
xvii) W.C. Connector (150 mm long) 125 X 110(W/WC Ring) 75 mm
xxx) Cleaning Pipe (a) 75 mm
xvi) Pipe Clip (a) 75 mm
(ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (It. No.1-24, P-74) A) Above ground (ii) 75 mm dia.
A) Under ground(ii) 110 mm dia.
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. (JSW/JSPL.....)
Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. (P-87 ; I-1; 6Th. corr. P-1,It.-1) a)with 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia. For-JSW/JSPL…..(P- 89 ; I-4 ; 6Th. corr. P-6,It-4)
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C......... (P- 88 ; I-3; 6Th corr. P-4,It-3) (ii) For 20 users(A) With Pakur Variety (JSW/JSPL…...)
Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. (i) 225 mm X 150 mm with 230 mm gratings
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) 32mm Dia
50mm Dia
(b) For Concealed Work (Dia)15mm Dia
20mm Dia
25mm Dia
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Concealed Work CPVC Pipes Class-1,SDR-11 a)15mm
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). 15mm Dia
25mm Dia
32mm Dia
50mm Dia
Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer. (P-37; I-6) 1500 litre capacity
Labour for hoisting plastic water storage tank. (P-37; I-10) (i) upto 1500 litre (a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank up to 50 mm dia. (P- 38; I-13)
Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. (Item-2 Page-79) a)with 'P' trap
Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. (Item- 2 Page-36)
Supplying fitting & fixing closet seat of approved make with lid & C.P hinges,rubber beffer & brush screw complete. (Item-10 Page-81) (a) E.W.C. (ii) Plastic (hallow type) white
Supplying fitting & fixing 32 mm. dia. flush pipe of approved make with necessary fixing materials & clam complete. (Item-11 Page-81) i)Polythene flush pipe.
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (Item-2 Page-41) ii) 550 mm X 400 mm size
(iv) Angle back wash basin 400 mm X 400 mm
(i) 450 mm X 300 mm size
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm (Item-19 Page-82)
Supplying, fitting and fixing shower of approved brand and make. (i) (2) Chromium plated overhead Rain shower (Round), size-200mm dia. with revolving joint (Model Code No. F7010601 of CERA or equivalent) [Item-3 Page-4]
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (Item- 5.b Page-42) (b) Laboratory sink with rim and overflow (ii) 500 mm X 300 mm X 150 mm
Supplying, fitting and fixing C.P. chain and stay with rubber plug.. (Item-11, Page-43) (ii) 32 mm dia. of plug
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia. (Item-9, Page-43) i) 450mm long
Suppling fitting & fixing approved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clamps (Item-10, Page-43) i)900mm long
(i) Supplying, fitting and fixing liquid soap container c) fibre glass (PWD SOR: 82/17)
Supplying, fitting and fixing bib cock or stop cock. (It-7, P-6) (b)iii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm (Stop Cock) (i) for Basin
(ii) for Toilet main line
Supplying, fitting and fixing pillar cock of approved make. b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). (P-45, I-19) for toilets
f) (i) CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR or similar brand). For Laboratory sink
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass 25 mm dia. and 600 mm long (It-22 a(i) P-82) (Nurse, MOIS Room)
(i) 25 mm dia. and 450 mm long (Labour Room)
Suppling fitting & fixing c.i round grating i)100mm
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (i) 75 mm dia. (P-64, I-9)
Supply fitting and fixing Fire Exyinguisher Conforming to ISI marked ( IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 kgs. Capacity , with initial filling in brand new cylinder with poder coated finish , fitted with gun metal union , discharge hose , wall mounting bracket and suitable sinage etc. complete ( Make: Fire Shield / New age / De Flame / Andex or equivalent ). A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted )
Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.)
Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.)
Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White
Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for bettr grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.) 750 mm long
Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent).
PARKING AREA & HORITCULTURE Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Fine sand
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety] i) In Ground floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes a) M-20 grade with Pakur variety i) In ground floor and foundation.
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. i) In foundation & ground floor
Brick work with 1st class Bricks with cement morter (1:6) (a) In foundation and plinth
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (ii) 25 mm. thick i) In ground floor
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%)
Spreading of sludge, dump manure,/farm yard manure/animel dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc. xxvii) Areca Palm 4 - 5 suckers of height 120 cm to 135 cm in earthen pots of size 25 cm.
Rangon Hy-Breed Healthy plant
Bougainvillea ( mix variety) of height 30cm to 90 cm in polybag of size 10 cm -15 cm
COMMON COLLECTION SITE Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trench in all sorts of soil (including mixed soil but excluding laterite of sand stone) including the spoils with in a lead of 75,m as directed. The includes necessary trimming the sides of trenches leveling dressing and ramming the bottom bailing out water as required complete. (a) Depth of excavation not exceeding 1.5m
Earth work in filling in foundation trenches or plinth with good earth,in layers not exceeding 150 mm. including watering & ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished qty. of work ) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Fine sand
Single Brick flat soling of picked jhama brick including raming and dressing bed to proper level and filling joints with powdered earthor local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) M-20 grade with Pakur variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel JSW/JSPL/SHYAM
Brick work with 1st class bricks in cement mortar (1:6) In foundation & plinth
In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Labour for Chipping of concrete surface before taking up Plastering work.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20 mm thick out side plaster (with 1:6 cement morter)
15 mm thick inside plaster (with 1:6 cement morter)
10mm th. (1:4) Ceiling
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (Roof)
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department].
Neat cement punning about 1.5mm thick in wall, dado, window,sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative
M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame ) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete , as directed. In ground floor.
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm). In ground floor. (b)25 mm mesh
Priming one coat on timber or plaster surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand paering etc.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamael paint of approved make and brand including smoothening surface by sand paering etc. including using of approved putty etc. on the surface if necessary On steel or other metal surface : With super gloss (hi-gloss)- Two Coats ( With any shade except white )
Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) (b) For Concealed Work PVC Pipes (Dia) 15 mm
(a) For Exposed Work 40 mm
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia. (Rain Water)
a) Plain Tee (ii) 110 mm. Dia.
b) Plain Y (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (a) 500 litre capacity
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect
Roof Top Rain Water Harvesting Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (JSW/JSPL..........)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Fine sand
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes a) M-20 grade with Pakur variety i) In ground floor and foundation.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. JSW/JSPL/SHYAM/RINL i) In foundation & ground floor
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. i) In foundation & ground floor
Brick work with 1st class Bricks with cement morter (1:6) (a) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. b) 15 mm. thick plaster (6:1) i) In ground floor
Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All type of soils. 23.1.1.3 400 mm Dia
23.1.2 For Rocky Strata including Boulders 23.1.2.3 400 mm Dia
Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well Casing (CM) pipe of required dia, conforming to IS 12818, including required hire and labour charges, fittings & accessories etc.. all complete, for all depths,, as per direction of Engineer-in-charge. 23.3.1. 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.3. 200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia.
R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. In ground floor (a) 50 mm. Thick panels JSW/SHYAM/JSPL/RINL
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
a) Plain Tee(ii) 110 mm. Dia.
c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia) 100 mm
Renewing gully grating. (i) 375 mm X 300 mm X 40 mm X 18 kg (Rate multiply by 100/105 for new work)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm (Vent pipe)
xv) Vent Cowl (b) 110 mm
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 23.13.3 200 mm dia
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
DG SET Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety] i) In Ground floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes a) [Pakur Variety]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. JSW/JSPL/SHYAM/............
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work
Brick work with 1st class Bricks with cement morter (1:6) (a) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. a) 20 mm. thick plaster (6:1)
2 H.P. SUBMERCIBLE MOTOR SET Supply & installation of three phase, 415V, 2.00 HP Submersible pump Motor set (KSB-CORA 2C/21, CORA 100 + UMAI-100, 1.10/22, 1.1 KW)
Supply & installation of three phase starting Device suitable for KSB 2.0HP Submersible pump Motor set with three phase prevention facility on iron legs on wall (Starting Capacitor- 100-120 MFD, Running Capacitor-40 MFD).
Supplying & fitting 200 mm dia tube well cover made of 3 mm thick of MS plate incl. necessary drilled holes, GI bends ets as reqd.
Supplying & fitting 50 mmx 6mm MS half round type holding clamp with 4nos. Drilling holes on each half including S & F necessary nuts & bolts.
Supply & laying 1.1 KV grade 4.0 core 25 sq. mm. PVC/ Ar Al cable from meter room to outdoor kiosk.
Supply & Fittings water proof 3 core 2.5sq. Mm. flat for pump from starter near panel to pump.
Mobilization of machinery and equipments required for drilling, lowering the assembly, developing, perform yield test including supplying the all labour, transport, tools, and tackles complete.
Charges for conducting vertical eletrical sounding using a resistivity meter for ground water exploretion including all labour charges, trasportetion at VES data.
Drilling Bore Hole by a suitable DTH cum mud rotary combination rig with foam and mud drilling including collection of Litho- Logical surplus with maintaining the time log for drilling through different points as directed by E.I.C. a) Drilling 250mm dia. borehole suitable for lowering 200mm internal dia. casing pipe lowering through over burden of clay / consolidated moorum / consolidated laterite fragmented granite formation including lowering the casing pipe through over burden up to a depth of 30 mtr. Below ground level.
b) Drilling through fissured consolidated hard rock prists with necessary valve for hammer and with necessary air pressure (not less than 200 sit) from 30 mtr. to 200 mtr.
Development of the tube well and making yield test complete by a suitable diesel driven pump set and generator as per direction of E.I.C. (02 days). This work will be including the cost of hire charges of pump set, Generator set, required length of suction and delivery pipes, measuring instruments, making derrick arrangements, lowering and withdrawing charges of pump and column pipes, supply of fuel and lubricants, labour charges and all other materials including carrying charges.
ELECTRICAL INSTALLATION WORKS SUB-HEAD 1--Distribution Wiring Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC] Average run 8 mtr
Average run 6 mtr
Distn. wiring in 3x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V, 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC) On Board
Average run 3 mtr
SUB-HEAD 2-- PLUGS & SOCKETSSupply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [ Computer Board ]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [16 Amp Plug Point]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (For 2x5A Points) 6 Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required (For 2x5A Points)
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For 2x5A Points)
Supply & Fixing 240 V 20 A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required (For Geyser Point)
Supply & Fixing 240 V, 20 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For Geyser Point)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/5(a)]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17/5(b)]
Supplying & Fixing Industrial Plug & Socket board with 240V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SPMCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary conection.
SUB-HEAD 3--BDB,PDB,VTPN, SFU ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make: Legrand/ABB/SIEMENS/Schneider/L&T] 2+14 way
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: Legrand/ABB/SIEMENS/Schneider/L&T] 6 way
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: Legrand/ABB/SIEMENS/Schneider/L&T] 6 way- Up to 160A
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [Make: Legrand/ABB/SIEMENS/Schneider/L&T] 415V, 63 A FP
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [Make: Legrand / ABB /SIEMENS/Schneider/L&T] 160A
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make: Legrand / ABB /SIEMENS/Schneider/L&T] 6-32 SP MCB
32 A TP MCB
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical / SPNDB enclosure with IP-42/43 protection as per GS. 4/6/8/12 Way (Vertical)
4/6 Way (Horizontal)
Supplying and fixing 415V, DP TPN SFU with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F DIN type HRC fuse as per rating. [Make: Legrand / ABB /SIEMENS/Schneider/L&T] 32A DP M/S( Compound light, Pump )
63A TP M/S
160 a TPN M/S
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. 160A ( L&T/ Havells/ Standard/ Siemens)
SUB-HEAD 4-- Polythene pipe and wires Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. [Make- Finolex/Polycab/RR Kabel/KEI] 3 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
4x126/0.4 (16 sqmm) + 2x80/0.3 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5sqmm
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws. 150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
SUB-HEAD 5---SUPPLY OF LIGHT FITTINGS Supply and Delivery of 4 feet twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply & Delivery of 240V, Rechargeable Emergency LED lamps of following wattage having minimam 2200 mAh Lithium Ion battery with glare free light distribution having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 10W LED Bulb B22/E27 Base
Supply & Delivery of 240V LED lamps of following wattage with glare free light distribution having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 10W LED Bulb B22/E27 Base
Supply & Delivery of minimum10-12 Watt LED Bulkhead light fittings complete with all accessories having die cast aluminium housing finished in premium white powder coating with CCT (5700K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Fixing of MS Down Rod of 5.5/6 ft length ,14SWg thick with both ends threded and providing with check nuts,split pin, holes as required including complete 2 coat painting,fixing, alignment, testing, commissioning as per direction of EIC.
SUB-HEAD 6-- FIXING OF LIGHT FITTINGS Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only lamp
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only bulk head/ Wall Bracket light fitting on wall /ceiling by screws etc.
SUB-HEAD 7 -- SUPPLY OF FANSSupply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories including safety wire and P2 Capacitor. (Make- Crompton / Usha striker plus / Orient Newbreeze or summercool/ Polar Approved by EIC [BEE star rated] Sweep Size- 1400 mm (56"), Wattage ≤ 75 Watt, R.PM ≤ 350, Air Delivery ≥ 260
Sweep Size- 1200 mm (48"), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220
Supply & Delivery of 240V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated] 230 mm (12"), 4 Blade, RPM ≤ 1400 , Wattage ≤ 55 Watt, Noise level ≤ 55 dB
230 mm (9"), 4 Blade, RPM ≤ 1500 , Wattage ≤ 45 Watt, Noise level ≤ 50 dB,
Supply & Delivery 4-blades, Metal Body AC wall bracket fan (Orient: Wall-II Tornado) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [C-4/29] 16 inch
SUB-HEAD 8-- FIXING OF FANSSupplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [D-14/29]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Engraving the deptt. number with 10 mm lettering on the body as per GS.
Extra for additional one letter incl. hifen, stroke and stop
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter. 23 cm Exhaust fan (12")
23 cm Exhaust fan (9")
Supply & Fixing GI sheet (20 SWG) metal cowl with MS flat iron frame & GI wire mesh on wall with necy. Bolts & nuts(6 mm dia x 62 mm lng) louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm Exhaust fan (12")
23 cm Exhaust fan (9")
Fixing of Metal Body AC wall bracket fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [C-4/29] 16 inch
Sub Head 9 : SITC of Air Conditioning Machines Supply & Delivery of fixed speed wall mounted type split airconditioners with rotary compressorhaving following major specifications Rated Cooling at 100% Capacity : 5300 W or Higher Rated Power Consumption at 100% capacity : 1400 W or lower ISEER Rating : 3.8 or Higher BEE star Rating : 3 star or Higher Air-flow/IDU-800 CFM or Higher Evaporator & Condenser Coil- Copper made Refrigerent -R410A/R407C/R32(Green Refrigerant) Capacity-1.5 Tr or Higher Power Supply :220v, 50Hz,1Ph AC (with applicable tolarance) [ Make-Fujitsu General (ASGA18 BUTA-B) / Mitshubishi Electric (MS/MU-AGZ18VF or equivalent model of Mitshubishi Heavy Industries]
Supply & Delivery of fixed speed wall mounted type split airconditioners with rotary compressorhaving following major specifications Rated Cooling at 100% Capacity : 6700W or Higher Rated Power Consumption at 100% capacity : 1800W or lower ISEER Rating : 3.8 or Higher BEE star Rating : 3 star or Higher Air-flow/IDU-800 CFM or Higher Evaporator & Condenser Coil- Copper made Refrigerent -R410A/R32(Green Refrigerant) Capacity-1.9 / 2 Tr or Higher Power Supply :220v, 50Hz,1Ph AC (with applicable tolarance) [ Make-Fujitsu General (ASGA24BUTA-B) / Mitshubishi Electric (MS/MU-AGZ24VF or equivalent model of Mitshubishi Heavy Industries]
Supply, Installation, testing and commissioning Extra copper pipes required for installation of units including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for the system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required [Cu. Pipe Make : Nippon/Mandev/Ryoku][Insulation Make-K-Flex/Accroflex/Suprime] 6.35 mm (1/4") dia (OD)with tube thickness0.8mm with 9mm thick nitrile insulation for liquid line for 2/1.5 Tr split AC Machine
15.9 mm (5/8") dia (OD) with tube thickness 0.8 mm with 9 mm thick insulation for suction line for 2/1.5 Tr split AC machine
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex) a) Liquid Line (1/4" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply, laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (Make:-Finolex/Havells/Polycab)Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex) a) 3 core 2.5 sq.mm communication cable
Installation Testing and Commissioning of wall mounted fixed speed split AirConditioners by making scaffolding arrangement as per site condition, Supply of necessary Refrigerant, connecting Control & power cabling, Angle brackets and plates required for fixing outdoor and indoor unit & other necessary materials to complete the job.
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. a) 25 mm dia
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections
SUB-HEAD 10 --MISCELLANEOUS Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
SITC of following capacity vertical/ horizontal type water geyser having following specification and accessories: Closed water geyser, Class- I, 230V, 50 Hz AC, BEE 5 Star Rating, Blue Diamond Glass Lined tank and Glass Coated Incoloy heating element, outer container should be made with mild steel and having water proof powder coating to protect from rust & corrosion with the facility of “Green” & “Red” indicator, Superior polymer coated tank, with the safety of Thermostat, Thermal cut out, Temperature controlled facility, Multi function valve & sacrificial anode & must be protected against galvanic corrosion, Manufactured in modern automated plant using European Technology. (Make- Venus/ Racold/ AO Smith/ Bajaj/ Crompton/Havells/ V-Guard/Orient) [No Geyser has been considered for Qarters, occupants of the quarter will install the Geyser at own expense if needed ) 15 Litre
SUB-HEAD 11--Supplying & Laying of Cable Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells as approved by E.I.C] 4 core 70 sqmm
4 core 25 sqmm
2 core 10 sqmm
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Supplying and Fixing medium gauge GI pipe (ISI- medium) protection with necessary fittings and jointiung materiuals as required. 40 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 70 sqmm
4 core 25 sqmm
2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 70 sqmm
4 core 25 sqmm
2 core 10 sqmm
SUB-HEAD 12 -- EARTHING INSTALLATION :-Excavation of soil for installation of Earth Electrode and filling & ramming. (For Morrum Soil)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 25 mm x 6 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments body to earth busbar incl. S & F 20 mm x 3 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Supplying & fixing sheet metal (16SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars 415 V, 100 A, Dimension of Al. bars [600 mm long]: 4 x 50x5mm , Dimension of Sheet Metal Box 750x150mm.
SUB-HEAD-13 Compound light Supply of 09 mtr long ST pole (Model-410 SP-25).Overall length 09 mtrs & planting depth 1.5 mtrs.Length of section bottom-5 mtr,middle-2 mtr and top 2 mtr long out side thickness of section bottom 11 4. 3x3 .6 5 mm,middle-88 .9x 3. 25 mm and top 76 .1x 3. 25 mm with base plate as per direction of EIC.Approx weight of pole-78 Kg. (M-Calcutta Pole/Bansal
Supply and Fixing of Double arm header assembly fabricated from 40mm dia. GI Pipe (ISI-M) of following length rigidly welded with 80 mm dia. GI Pipe (ISI-M) of 0.3 Mtr. long as pole sleeves at an angle of 105⁰ including S/F 3 Nos ½” MS jam nut each with 1No. ½” dia. through bolt, pole cap and painting as to GS of the entire assembly. (Make- Transrail/ Bajaj/ Bansal)
Supply & fixing of 240V, 90W LED street lights with optic lens and polycarbonate diffuser having following wattage, in white powder coated pressure die cast aluminium housing with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Erection of Single Steel tubular pole of length up to 9 mtr with sole plate etc. in CC foundation (Proportion 4:2:1 and dimension 0.6x0.6x1.7 mtr) having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.Upto 9.0 mtr. Size 0.6x0.6x1.70 mts[H-1/1.(a)]
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level ,neatly cemented (3 mm thick)at the base pole(In lieu of CCmuffing) suitable for alkathene/polythene pipe as directed for street light wiring . Without loop box(I-1,item-13(a)
S&F 65 mm dia . GI pipe pole (Tata Make- Medium) of 1.5 mtrs long with sole plate on roof incl.CC (6:3:1) muffing 0.45x0.45 x600mm. in size or equivalent cylindrical muffing above roof level incl. 3mm.thick neat cemented finish and G.I. earth bolt, Cable entry after making holes on pole incl. S&F 250x250 x100mm. GI (2 mm thick) loop box in pole muffing and S&F single arm brackets assembly made of 80mm dia 0.3mtr long welding with 32 mm dia 1.5 mtr long steel pipe 3.64mm thick including painting with synthetic enamel paint as per GS. [NS]
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. 250 x 250 x 100mm
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole[H-2/7.A(a)] (i) One coat of red lead/Zinc chromate priming
(ii) 1st coat of synthetic enamel paint over the primer
(iii) 2nd coat of synthetic enamel paint over the 1st coat
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe(G1/2) incl. all necy arrangement asper direction of EIC.
Supply & Delivary LED Decorative Post Top light fitting in Pressure die cast Aluminum base with Prismatic polycarbonate diffuser having following wattage, with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 40,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 40 Watt
Supply & Fixing of 80/40mm dia GI pipe (ISI-M) of 1.5M long on the existing piller of GATE including making arrangement for CC construction upon the piller for fixing of GATE light and making necessary connection.
Sub-Head-14: TIMER DB & LED SIGN BOARDS&F of 250V, 25A timer controlled single starter for controlling compound lights in SS double door 2+10 way DB enclosure (L&T / ABB / Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm2 copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall incl. necessary connections as per direction of EIC : - 25A DP MCB (L&T / ABB / Legrand make) – 1 no. 24Hr x 7 days programmable Digital timer (L&T make Cat no 67DDTO) – 1 no. 3-pole power contactor (L&T make Cat no MNX22 / 250V) – 1 no. 1-Module 10A Modular switch (Make Legrand / Myrius) – 1 no. 3-module plate with cover (Make Legrand / Myrius) – 1 no. 25A Auto-Off-Bipass SPDT toggle switch (approved reputed make) – 1 no. LED indication lamp (approved reputed make) – 1 no. Outgoing bakelite connector 32A (Reputed make as approved by EIC) – 2 nos.
LED SIGNAGE :- Supply, Installation, Testing and commissioning of LED Illumination sign board fabricated by required size of 5" (inch) depth ACP box supported with 1"x1" MS hollow square pipe or Aluminium Hollow square pipe of 18 swg. All around. The 3 mm ACO facial should be provided with Laser cutting 6 mm laser cut Acrylic letters out of which 5 mm rising and border line of the front side shold with cover 1" Alluminium channel as per the direction of EIC. The sign board should be glow by 1.5 W LED module cool white in colour including 12 V 250 W power supply. Back side of the board should be covered with 26 swg GI sheet to protect rain water. The sign board should be fixed at the wall by using nut, bolt, washers etc. after making MS structure and grouting the same at wall and mending good the damages as per direction of EIC. The cost of transportation and scaffolding charges are included. inscription of the sign board should be as per direction of authority and as per direction of EIC.
Supply and Fixing of Hylam sheet of suitable size ( minimum 12 mm thick), ISI marked, for mounting switchgear/ fuse units. Fixed on wall with brass screws and washers, complete as required as per direction of EIC.
SITC of Water Purifier Supply, fixing, commisioning and Testing including all necessary arrangements for complete installation of wall mounted water purifier having storage capacity - Not less than 8Litre, RO+UF+TDS control + UV in Tank + Copper water Purifier, purification production Rate- Not less than 15 L/ hr with 1 year warranty + 3 Years Extended Sevice Free. ( Including all taxes ) ( Make : Kent/ Lg/ Ureka forbes )
ADD GST @ 18 % (Excluding Sl No. 199 to 208)
Add L.W. Cess @ 1% (Excluding Sl No. 199 to 208)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.89 MB
Tendernotice_2.pdf
PDF • 1.27 MB
BOQ_2389128.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .