| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.5 LAccepted-AOC | ₹55.5 L | L1 | Accepted-AOC Lowest offer |
| 2 | L2₹73.2 LRejected-Finance | ₹73.2 L | L2 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | SMBS INFRA DEVELOPERS L1 | KUMARAN KUDIL CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00BOQ | |||||
| 1.01 | EARTH WORK EXCAVATION IN ALL SOILS AND SUB SOILS EXCLUDING ROCK INCLUDING BACKFILLING IN SIDES OF FOUNDATIONS AND BASEMENT, WATERING, CONSOLIDATION, INCLUDING DEWATERING WHEREVER NECESSARY, ETC., AND DISPOSING OFF THE SURPLUS EARTH WITHIN A LEAD OF 40 MTRS AS DIRECTED IN DEPTH FROM GROUND LEVEL TO | 550 | CUM | 150 ₹82,500 | 150 ₹82,500 |
| 1.02 | EXCAVATE AND REMOVE HARD ROCK REQUIRING CONTROLLED BLASTING AT ALL LEVELS (40% TO BE DEDUCTED IN STACK MEASUREMENTS OR ACTUAL EXCAVATED HARD ROCK PRE-MEASUREMENT WILL BE TAKEN INTO ACCOUNT WITHOUT STACKING) INCLUDING DEWATERING AND DISPOSE OFF WITHIN A LEAD OF 40 MTR AS DIRECTE | 10 | CUM | 800 ₹8,000 | 1,000 ₹10,000 |
| 1.03 | EARTH CUTTING, TRANSPORTATION WITHIN THE PREMISES, UNLOADING, SPREADING, LEVELLING AND CONSOLIDATION WITH 10MT ROAD ROLLER TO A LEAD OF 2KM. | 180 | CUM | 150 ₹27,000 | 160 ₹28,800 |
| 1.04 | PROVIDING ANTI-TERMITE TREATMENT AS PER IS 6313 WITH THE TERMITICIDES CURRENTLY ALLOWED UNDER THE INSECTICIDES ACT 1968 BY THE INSECTICIDES BOARD INCLUDING COST OF TERMITICIDES OF IS STANDARD, LABOUR, ETC., THE CHLOROPYRIFOS OR IMIDACCOPRID MIXED WITH WATER AS PER MANUFACTURER SPECIFICATION - DRILLING HOLE 12MM DIA AT THE JUNCTION OF FLOOR & WALLS, 150MM DEEP AT 300MM INTERVAL IN THE CONCRETE FLOOR INSIDE / OUTSIDE AS THE CASE MAY BE TO REACH THE SOIL BELOW AND FILL DILUTED CHEMICALS. | 350 | SQM | 50 ₹17,500 | 70 ₹24,500 |
| 1.05 | CEMENT CONCRETE 1:4:8 USING 25MM DOWN GAUGE BLUE GRANITE AGGREGATE IN FOUNDATIONS, MUD MAT, FLOORING EXCLUDING SHUTTERING BUT INCLUDING RAMMING, LEVELLING, CURING ETC., COMPLETE. | 55 | CUM | 3,300 ₹1.8 L | 3,500 ₹1.9 L |
| 1.06 | SUPPLY AND LAYING OF FLY ASH BRICKS IN CM 1:6 IN FOUNDATIONS AND BASEMENT UPTO +0.00 MTR INCLUDING CURING, ETC., COMPLETE. | 30 | CUM | 6,300 ₹1.9 L | 6,500 ₹1.9 L |
| 1.07 | SUPPLY AND LAYING OF FLY ASH BRICKS IN SUPER STRUCTURE IN CM 1:6 INCLUDING SCAFFOLDING, CURING ETC., COMPLETE ABOVE +0.00 MTR TO +7.00 MTR | 70 | CUM | 6,600 ₹4.6 L | 6,800 ₹4.8 L |
| 1.08 | CEMENT CONCRETE M25 USING 20MM SIZE BLUE GRANITE AGGREGATE FOR ALL CEMENT CONCRETE ITEMS SUCH AS FOOTING, RAFT, PLINTH BEAM, ETC., EXCLUDING SHUTTERING BUT INCLUDING LEVELLING, CURING, ETC., COMPLETE BELOW GROUND LEVEL AND UPTO FFL. | 75 | CUM | 3,600 ₹2.7 L | 3,700 ₹2.8 L |
| 1.09 | CEMENT CONCRETE M25 USING 20MM SIZE BLUE GRANITE AGGREGATE FOR ALL CEMENT CONCRETE ITEMS SUCH AS COLUMN, BEAM, SUNSHADE, SHELL WALL, ROOF SLAB, STAIRCASE, ETC., EXCLUDING SHUTTERING BUT INCLUDING LEVELLING, CURING, ETC., COMPLETE ABOVE FFL TO +7 MTR LEVEL. | 95 | CUM | 4,000 ₹3.8 L | 3,900 ₹3.7 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
12 Feb 2026, 3:00 pmClosed
General Manager (Projects and Energy)
PMD Office, TNPL Unit I, Kagithapuram.
Expansion of the Nursery and Primary school building (Phase III) at TNPL Unit II
2026_TNPL_646528_1
TNPL/PMD/CIV/CB/UNIT II/252623004030
Open Tender
Civil Works
120 days
TNPL Nursery and Primary School, Mondipatti, Trichy
As per Part 1 - Invitation for Bids of Bid Document
8 documents required · 8 mandatory
₹590
₹55,000
6 Mar 2026
23 Jan 2026
12 Feb 2026
23 Jan 2026
12 Feb 2026
23 Jan 2026
EARTH WORK EXCAVATION IN ALL SOILS AND SUB SOILS EXCLUDING ROCK INCLUDING BACKFILLING IN SIDES OF FOUNDATIONS AND BASEMENT, WATERING, CONSOLIDATION, INCLUDING DEWATERING WHEREVER NECESSARY, ETC., AND DISPOSING OFF THE SURPLUS EARTH WITHIN A LEAD OF 40 MTRS AS DIRECTED IN DEPTH FROM GROUND LEVEL TO
EXCAVATE AND REMOVE HARD ROCK REQUIRING CONTROLLED BLASTING AT ALL LEVELS (40% TO BE DEDUCTED IN STACK MEASUREMENTS OR ACTUAL EXCAVATED HARD ROCK PRE-MEASUREMENT WILL BE TAKEN INTO ACCOUNT WITHOUT STACKING) INCLUDING DEWATERING AND DISPOSE OFF WITHIN A LEAD OF 40 MTR AS DIRECTE
EARTH CUTTING, TRANSPORTATION WITHIN THE PREMISES, UNLOADING, SPREADING, LEVELLING AND CONSOLIDATION WITH 10MT ROAD ROLLER TO A LEAD OF 2KM.
PROVIDING ANTI-TERMITE TREATMENT AS PER IS 6313 WITH THE TERMITICIDES CURRENTLY ALLOWED UNDER THE INSECTICIDES ACT 1968 BY THE INSECTICIDES BOARD INCLUDING COST OF TERMITICIDES OF IS STANDARD, LABOUR, ETC., THE CHLOROPYRIFOS OR IMIDACCOPRID MIXED WITH WATER AS PER MANUFACTURER SPECIFICATION - DRILLING HOLE 12MM DIA AT THE JUNCTION OF FLOOR & WALLS, 150MM DEEP AT 300MM INTERVAL IN THE CONCRETE FLOOR INSIDE / OUTSIDE AS THE CASE MAY BE TO REACH THE SOIL BELOW AND FILL DILUTED CHEMICALS.
CEMENT CONCRETE 1:4:8 USING 25MM DOWN GAUGE BLUE GRANITE AGGREGATE IN FOUNDATIONS, MUD MAT, FLOORING EXCLUDING SHUTTERING BUT INCLUDING RAMMING, LEVELLING, CURING ETC., COMPLETE.
SUPPLY AND LAYING OF FLY ASH BRICKS IN CM 1:6 IN FOUNDATIONS AND BASEMENT UPTO +0.00 MTR INCLUDING CURING, ETC., COMPLETE.
SUPPLY AND LAYING OF FLY ASH BRICKS IN SUPER STRUCTURE IN CM 1:6 INCLUDING SCAFFOLDING, CURING ETC., COMPLETE ABOVE +0.00 MTR TO +7.00 MTR
CEMENT CONCRETE M25 USING 20MM SIZE BLUE GRANITE AGGREGATE FOR ALL CEMENT CONCRETE ITEMS SUCH AS FOOTING, RAFT, PLINTH BEAM, ETC., EXCLUDING SHUTTERING BUT INCLUDING LEVELLING, CURING, ETC., COMPLETE BELOW GROUND LEVEL AND UPTO FFL.
CEMENT CONCRETE M25 USING 20MM SIZE BLUE GRANITE AGGREGATE FOR ALL CEMENT CONCRETE ITEMS SUCH AS COLUMN, BEAM, SUNSHADE, SHELL WALL, ROOF SLAB, STAIRCASE, ETC., EXCLUDING SHUTTERING BUT INCLUDING LEVELLING, CURING, ETC., COMPLETE ABOVE FFL TO +7 MTR LEVEL.
FORM WORK - WROUGHT AND PUT UP WITH GOOD QUALITY MARINE GRADE PLYWOOD FOR ALL TYPES OF SHUTTERING WORKS LIKE FOOTING, RAFT, PLINTH BEAM, ETC., AS "PLASTER FREE FINISH" BELOW GROUND LEVEL AND UPTO FFL.
FORM WORK - WROUGHT AND PUT UP WITH GOOD QUALITY MARINE GRADE PLYWOOD FOR ALL TYPES OF SHUTTERING WORKS LIKE COLUMN, BEAM, SUNSHADE, SHELL WALL, ROOF SLAB, STAIRCASE, ETC., AS "PLASTER FREE FINISH" ABOVE FFL TO +7 MTR LEVEL.
TAKE DELIVERY OF HIGH STRENGTH RIBBED DEFORMED BARS/ MS BARS ISSUED BY TNPL FREE OF COST, CUT, BEND AND TIE UP IN POSITION INCLUDING COST OF SUPPLYING NECESSARY 18 GAUGE BINDING WIRE FOR ALL TYPES OF RCC WORKS AT ALL LEVELS.
PREPARE SURFACES OF CEILING AND PLASTER IN CEMENT MORTAR 1:4, 12MM THICK AT ALL LEVELS INCLUDING NECESSARY SCAFFOLDINGS AND CURING ETC., COMPLETE.
PREPARE SURFACES OF WALLS AND PLASTER INTERIOR, EXTERIOR AND TOP FACES WITH CEMENT MORTAR 1:4, 12MM THICK AT ALL LEVELS INCLUDING NECESSARY SCAFFOLDINGS AND CURING ETC., COMPLETE.
THOROUGHLY PREPARE SURFACES OF THE FLOOR, SUPPLY AND LAYING OF TILES 4' X 2' DOUBLE CHARGED / GLAZED VITRIFIED TILES WITH SPACER JOINT OVER THE FLOOR OF APPROVED SHADE AND COLOUR WITH TILE ADHESIVE COMPOUND WITHOUT ANY WAVINESS FOR FLOORS AND SKIRTING AND GROUTING WITH APPROVED TILE GROUT OF MAKE (BOSTIK /MYK LATICRETE / WEBER) CURING ETC., COMPLETE AT ALL LEVELS.
SUPPLYING AND FIXING OF CERAMIC FLOOR TILES ANTI SKID OF SIZE 600 X 300MM X 8MM THICK OF APPROVED MAKE AND SHADE WITH BED MORTAR IN CM 1:3, 20MM THICK TO DESIRED SLOPE AND POINTING THE JOINTS WITH TILE MAT COMPOUND, CURING, ETC., COMPLETE AT ALL LEVELS.
PREPARE SURFACES OF BASE COURSE BY REMOVING ALL LOOSE MORTAR BY HACKING AND LAY TO REQUIRED SLOPE 50 MM THICK GRANO FLOOR OF MIX 1:1.5:3 USING 10 TO 12 MM GRANITE CHIPS INCLUDING FINISHING THE TOP LAYER WITH A POWER TROWEL AT ALL LEVELS.
SUPPLYING AND FIXING OF ONE SIDE POLISHED GRANITE SLAB 16MM THICK OF APPROVED COLOUR AND FIX IN POSITION OVER CEMENT SLAB IN CM 1:3, 12 MM THICK AND POINTING THE JOINTS FREE WITH TILE MATT COMPOUND, NOSING OF EDGES, CURING ETC., COMPLETE AS DIRECTED BY ENGINEER IN CHARGE.
SUPPLYING AND FIXING OF APPROVED COLOUR COATED ALUMINIUM WINDOW (SLIDING TYPE ) OF FRAME SIZE 63MM X 45MM X 1.5MM THICK WITH NECESSARY LOCKING ARRANGMENT, RUBBER GASKET, BEADING ETC., INCLUDING 5MM THICK PLAIN GLASS FOR THE SAME (MAKE JINDAL OR INDAL SECTION).
PROVIDING AND FIXING IN POSITION COUNTRY WOOD (PILLAMARUDU / MALASIASAL / VENTEAK) DOUBLE LEAF PANELLED DOORS OF SIZE 1500 X 2400 WITH 100 X 65 MM SEASONED COUNTRY WOOD FRAMES WITH NECESSARY HOLD FASTS, AND SHUTTERS MADE OF 32MM THICK CW STYLES AND WIDTH AT TOP AND VERTICALS 125 MM, BOTTOM 230 MM AND LOCK RAILS 125 MM AND PANELLING WITH 12 MM THICK PLYWOOD BWR INCLUDING NECESSARY ALUMINIUM FITTINGS, SCREWS ETC., COMPLETE .
SUPPLYING AND FIXING IN POSITION OF MS GATE / GRILL USING SQUARE (OR) RECTANGULAR BAR INCLUDING NECESSARY WELDING AND APPROVED DESIGN INSTRUCTED BY ENGINEER INCHARGE INCLUDING APPLYING ONE SHOP COAT OF RED OXIDE PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT OF APPROVED COLOUR ETC., COMPLETE.
PROVIDING BORDERS WITH CM 1:3, 100MM WIDE, 20MM THICK INCLUDING FINISHING NEATLY, ETC, COMPLETE AT ALL LEVELS.
SUPPLYING AND FIXING OF SS 304 HANDRAILS WITH 40MM DIA AS VERTICAL AND TOP RAIL & 25 MM DIA IN THREE ROWS IN THE MIDDLE INCLUDING GROUTING THE LEGS WITH EPOXY MORTAR, BUFFING, POLISHING, ETC., COMPLETE.
SUPPLY AND APPLICATION OF ONE COAT OF BIRLA WHITE / JK WHITE OR EQUIVALENT QUALITY OVER WALL OR CEILING SURFACES INCLUDING COST OF SCAFFOLDING, ALL MATERIALS, LABOUR AND OTHER INCIDENTAL CHARGES ETC. COMPLETE AT ALL LEVELS.
THROUGHLY PREPARE THE SURFACES AND APPLY ONE COAT OF WALL PRIMER OF APPROVED MAKE OVER WALL PUTTY SURFACES AND APPLY TWO COATS OF ACRYLIC EMULSION IST QUALITY OF APPROVED COLOUR AND MAKE INCLUDING MATERIAL COST AND ALL CONSUMABLES LABOUR CHARGES, SCAFFOLDING ETC. COMPLETE AT ALL LEVELS.
SUPPLY AND APPLICATION OF ONE COAT OF WEATHER PROOF EXTERIOR PRIMER AND TWO COATS OF EXTERIOR EMULSION OF APPROVED COLOUR SHADE INCLUDING SCAFFOLDING, LABOUR ETC., COMPLETE AT ALL LEVELS. (ASIAN OR BERGER).
THOROUGHLY PREPARE THE SURFACES AND APPLYING SYNTHETIC ENAMEL PAINT TWO COATS OVER ONE COAT OF PRIMER FOR JOINERIES, ETC., AS DIRECTED INCLUDING NECESSARY SCAFFOLDING WHEREVER REQUIRED, ETC., COMPLETE AT ALL LEVELS.
PROVIDE AND FIX IN POSITION 110MM DIA PVC RAIN WATER PIPES INCLUDING NECESSARY CLAMPS, SWAN NECKS, BENDS, SHOES, TW BLOCK ETC., COMPLETE. (PRESSURE CAPACITY: 6 KG/ SQ.CM).
SUPPLY OF 25MM DIA THREADED U.PVC PIPE 40 SH OF FINOLEX MAKE AND LAYING IN POSITION INCLUDING NECESSARY SPECIALS LIKE BEND, ELBOW, CLAMPING, COUPLING INCLUDING NECESSARY EARTH WORK IN CASE OF UNDER GROUND LINE AND CONCEALING WORKS WHEREVER REQUIRED ETC., COMPLETE.
WIRING FOR SINGLE CONTROL LIGHT POINT WITH 2 X 1.5 SQ.MM, PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH 1 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AS EARTH WIRE IN RECESSED /SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANISED / CADMIUM PLATED MS SWITCH BOX, 6A SINGLE WAY MODULAR TYPE SWITCH ON MODULARPLATE AND MAKING NECESSARY CONNECTIONS ETC. COMPLETE AS REQUIRED AS PER SPECIFICATION.
WIRING FOR ADDITIONAL LIGHT POINTS WITHOUT SWITCH, SWITCH BOX WITH 2 X 1.5 SQ.MM, PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH 1 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AS EARTH WIRE IN RECESSED/SURFACE PVC CONDUIT AND MAKING NECESSARY CONNECTIONS ETC.
WIRING FOR CALL BELL POINT WITH 2 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR WIRE ALONG WITH 1X 1.5 SQ. MM. PVC INSULATED AS EARTH WIRE IN RECESSED/SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANIZE/CADMIUM PLATED MS SWITCH BOX, 6A SINGLE WAY MODULAR TYPE BELL PUSH ON MODULAR PLATE AND MAKING NECESSARY CONNECTION ETC. COMPLETE AS REQUIRED.
WIRING FOR TWO WAY CONTROL LIGHT POINT WITH 2 X 1.5 SQ. MM. FRLS PVC INSULATED STRANDED COPPER CONDUCTOR WIRE ALONG WITH 1 X 1.0 SQ. MM FRLS PVC INSULATED STRANDED COPPER CONDUCTOR WIRE AS EARTH WIRE IN RECESSED/SURFACE 2 MM THICK PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANIZED/CADMIUM PLATED MS SWITCH BOX, 6A TWO WAY MODULAR TYPE SWITCH ON MODULAR PLATE AND MAKING NECESSARY CONNECTION ETC., (SINGLE LIGHT POINT CONTROLLED BY ONE SET OF ( TWO NOS). TWO WAY SWITCHES AT TWO DIFFERENT LOCATIONS.)
WIRING FOR TWO WAY FAN POINT WITH 2 X 1.5 SQ. MM. FRLS PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH 1 X 1.5 SQ. MM. FRLS PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AS EARTH WIRE IN RECESSED/SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANISED / CADMIUM PLATED MS SWITCH BOX, 2 NOS.6A MODULAR TYPE SWITCH AND 2NOS. 300 W ELECTRONIC REGULATOR ON MODULAR PLATE AND MAKING NECESSARY CONNECTIONS ETC. COMPLETE AS REQUIRED AS PER SPECIFICATION.
WIRING FOR FAN POINT WITH 2 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH 1 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AS EARTH WIRE IN RECESSED/SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANISED / CADMIUM PLATED MS SWITCH BOX, 6A MODULAR TYPE SWITCH AND 300 W ELECTRONIC REGULATOR ON MODULAR PLATE AND MAKING NECESSARY CONNECTIONS ETC. COMPLETE AS REQUIRED AS PER SPECIFICATION.
WIRING FOR EXHAUST FAN POINT WITH 2 X 1.5 SQ.MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH 1 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AS EARTH WIRE IN RECESSED/SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING GALVANISED / CADMIUM PLATED MS SWITCH BOX, 6A MODULAR TYPE SWITCH (ALONG WITH OTHER SWITCHES), 6 A 3 PIN MODULAR TYPE SOCKET OUTLET WITH 6A PLUG TOP IN A GI /MS PLATED CADMIUM BOX ON MODULAR PLATE NEAR THE EXHAUST FAN AND MAKING NECESSARY CONNECTIONS ETC., COMPLETE AS REQUIRED AS PER SPECIFICATION.
WIRING FOR DEPENDENT 6 A, 3 PIN SOCKET OUTLET WITH 2 X1.5 SQMM PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AND 1 X 1.5 SQMM PVC INSULATED STRANDED CU.CONDUCTOR CABLE AS EARTH WIRE, IN RECESSED/SURFACE PVC CONDUIT, INCLUDING PROVIDING AND FIXING CADMIUM PLATED / GALVANISEDMS SWITCH BOX, 6 AMPS MODULAR TYPE SINGLE WAY SWITCH, 6 A 5 PIN, MODULAR TYPE SHUTTERED SOCKET OUTLET ON MODULAR PLATE AND MAKING CONNECTIONS ETC., COMPLETE AS REQUIRED AS PER SPECIFICATION. ( SWITCH BOARD PLUG )
WIRING FOR INDEPENDENT 6 A, 3 PIN SOCKET OUTLET WITH 2 X 1.5 SQ. MM. PVC INSULATED STRANDED COPPER CONDUCTOR CABLE AND 1 X 1.5 SQ. MM. PVC INSULATED STRANDED CU. CONDUCTOR CABLE AS EARTH WIRE, IN RECESSED /SURFACE PVC CONDUIT INCLUDING PROVIDING AND FIXING CADMIUM PLATED /GALVANISED MS SWITCH BOX, 6 AMPS SINGLE WAY MODULAR TYPE SWITCH, 6A 5 PIN, MODULAR TYPE SHUTTERED SOCKET OUTLET MODULAR PLATE INCLUDING MAKING CONNECTIONS ETC., COMPLETE AS REQUIRED AS PER SPECIFICATION.
SUPPLY AND FIXING IN RECESS / SURFACE CADMIUM PLATED / GALVANISED M.S SWITCH BOX INCLUDING PROVIDING AND FIXING 16 A ONE WAY MODULAR TYPE SWITCH, 5/15 A 6 PIN MODULAR TYPE SHUTTERED SOCKET OUTLET ON MODULAR PLATE INCLUDING MAKING CONNECTIONS AS PER SPECIFICATIONS (FOR POWER PLUGS).
SUPPLY AND FIXING OF 20 AMPS., 240 VOLTS, SPN, INDUSTRIAL TYPE METAL GLAD SOCKET OUTLET NEAR THE AC UNIT AND METAL ENCLOSED PLUG TOP AND SEPARATE 20 AMPS., DP MCB, IN SHEET STEEL ENCLOSURE/20A 30MA DP ELCB, ON SURFACE OR IN RECESS, WITH CHAINED METAL COVER FOR THE SOCKET OUTLET, AND COMPLETE WITH CONNECTIONS, TESTING AND COMMISSIONING ETC. COMPLETE AS REQUIRED (FOR AIRCONDITIONER UNIT).
WIRING FOR CIRCUIT /POWER / SUB MAIN/DG POWER WITH 2 X2.5 SQMM + 1 X 1.5 SQMM (E) PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH PVC INSULATED STRANDED CU. CONDUCTOR CABLE AS EARTH WIRE IN RECESSED / SURFACE PVC CONDUIT INCLUDING MAKING CONNECTION ETC., AS PER SPECIFICATION.
WIRING FOR CIRCUIT /POWER / SUB MAIN/DG POWER WITH 2 X 4 SQMM +1 X 2.5 SQMM (E) PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH PVC INSULATED STRANDED CU. CONDUCTOR CABLE AS EARTH WIRE IN RECESSED / SURFACE PVC CONDUIT INCLUDING MAKING CONNECTION ETC., AS PER SPECIFICATION.
WIRING FOR CIRCUIT /POWER / SUB MAIN/DG POWER WITH 5 X 10 SQ. MM. + 1 X 4 SQ. MM (E) PVC INSULATED STRANDED COPPER CONDUCTOR CABLE ALONG WITH PVC INSULATED STRANDED CU. CONDUCTOR CABLE AS EARTH WIRE IN RECESSED / SURFACE PVC CONDUIT INCLUDING MAKING CONNECTION ETC., AS PER SPECIFICATION.
SUPPLY AND ERECTION OF 3 PHASE 6 WAY TPN DOUBLE DOOR DB (DISTRIBUTION BOARD) THE NECESSARY ANGLE FRAME, BOLT & NUT INCOMING SUITABLE ADAPTER BOS & EARTHING: INCOMING - 63A 4P RCCBO - 1 NO, AND OUTGOING : 32 DB MCB - 1 NO, 16A SP MCB - 10NOS & 6A SP MCBS -06 NOS.
SUPPLY AND FIXING OF 20 MM SIZE EMPTY PVC CONDUIT ALONGWITH THE ACCESSORIES IN SURFACE/RECESS INCLUDING CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED
SUPPLY AND FIXING OF 25 MM SIZE EMPTY PVC CONDUIT ALONGWITH THE ACCESSORIES IN SURFACE/RECESS INCLUDING CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED
SUPPLY AND FIXING OF 32 MM SIZE EMPTY PVC CONDUIT ALONGWITH THE ACCESSORIES IN SURFACE/RECESS INCLUDING CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED
SUPPLY AND FIXING OF GI/CADMIUM PLATED ADOPTOR BOX OF SIZE 300 MM X 200 MM X 100 (D) TO RECEIVE 16 NOS.OF 25/32 MM CONDUIT FROM THE INDIVIDUAL FLOOR WITH PHENOLINIC LAMINATED SHEET COVER COMPLETE AS REQUIRED
SUPPLY AND FIXING OF GI/CADMIUM PLATED ADOPTOR BOX OF SIZE 500 MM X 200 MM X 100 (D) TO RECEIVE 16 NOS.OF 25/32 MM CONDUIT FROM THE INDIVIDUAL FLOOR WITH PHENOLINIC LAMINATED SHEET COVER COMPLETE AS REQUIRED.
SUPPLY AND FIXING OF GI/CADMIUM PLATED ADOPTOR BOX OF SIZE 300 MM X 200 MM X 100 (D) WITH SUITABLE CONNECTOR 4C*35 SQMM AL AR CABLE TERMINATION WORK.
EARTHING WITH GI ("B" CLASS) EARTH PIPE 4.5 MT. LONG X 40 MM. DIA. INCLUDING ACCESSORIES, AND PROVIDING MASONARY ENCLOSURE WITH COVER PLATE HAVING LOCKING ARRANGEMENT, PAINTING AND WATERING PIPE ETC. WITH CHARCOAL ,SALT AND SAND COMPLETE AS REQUIRED
SUPPLY AND FIXING OF 50X6 MM GI FLAT ON SURFACE OR IN RECESS FOR CONNECTIONS ETC. AS REQUIRED.
SUPPLY AND FIXING OF 25X3 MM GI FLAT ON SURFACE OR IN RECESS FOR CONNECTIONS ETC. AS REQUIRED.
SUPPLY AND FIXING OF 1X40W LEDLUMINAIRE
SUPPLY AND FIXING OF 1200 MM BLDC CEILING FAN WITH NECESSARY ACCESSERIES AS REQUIRED.
SUPPLY AND FIXING OF 20 A MCB WITH WEATHER PROOF COVER WITH BASE COVER
SUPPLY AND FXING OF PENDAT HOLDER.
SUPPLY AND FIXING OF JB BASE COVER.
SUPPLY AND FIXING OF CEILING ROSE WITH BASE COVER
SUPPLY AND FIXING OF 70 W LED STREET LIGHT FITTING
SUPPLY & FIXING OF 2 X 2 LED DECORATIVE LIGHT FIXTURE
SUPPLY AND LAYING OF 4CX35 SQ.MM AR.AL CABLE
CABLE TERMINATION OF LT CABLES ON BOTH ENDS/STRAIGHT THROUGH JOINT AFTER LAYING 35 SQ MM CABLE (WHETHER CABLE SHOULD BE ARMOURED / UNARMOURED, COPPER / ALUMINIUM, 4C/3C CABLE)
EXCAVATION UPTO A DEPTH OF 600MM FOR LAYING THE ABOVE CABLES SIZES, 2" SAND CUSHIONING AND 3 SIDE BRICK LAYING REFILLING TRENCH INCLUDING COST OF SAND, BRICK ETC.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_774991.xls
BOQ • 0.34 MB
BidDocument_252623004030_Signed.pdf
Tender Documents • 14.47 MB
Download all tender documents and submit your bid