Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹35.0 L+₹13,860 (0.40%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹35.3 L+₹42,951 (1.23%)Rejected-AOC | L3 | Rejected-AOC Other than the lowest bidder | |
| 4 | L4₹36.8 L+₹2.0 L (5.76%)Rejected-AOC | L4 | Rejected-AOC Other than the lowest bidder | |
| 5 | L5₹37.4 L+₹2.6 L (7.43%)Rejected-AOC VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | L5 | Rejected-AOC Other than the lowest bidder |
| Sl No | Description | Qty | Unit | Papai Enterprises L4 | REMCO L2 | azad enterprise L5 | PIONEER TRADING L6 | ChakrabortyTraders L7 | ELECTRO COMMERCIAL CO L1 | SHARMA CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Checking of Instrument Panel internal wiring connections with relay,instrument transformers, metering instrument, indicating instrument, selector switches & circuit breaker control switches,CT/PT circuit wiring, earth fault circuit wiring wire not less than 1.5,2.5 4.0 sqmm etc the connections shall be securely made with the help of suitable connecting lugs duly crimped with the conductor and testing complete all as specified and directed | 4 | Each Job | 1,500 ₹6,000 Lowest | 1,955 ₹7,820 | 6,500 ₹26,000 | 2,500 ₹10,000 | 6,000 ₹24,000 | 1,500 ₹6,000 Lowest | 2,050 ₹8,200 |
| 2.00 | Supply and fix in repairs 11 KV HT VCB operating mechanism with motor operated spring charged system assembly including coil assembly with 24 Volts DC auxiliary supply system works satisfactorily and testing complete all as specified and directed | 1 | Each Job | 2,200 ₹2,200 | 3,500 ₹3,500 | 8,500 ₹8,500 | 3,000 ₹3,000 | 4,000 ₹4,000 | 1,600 ₹1,600 Lowest | 2,700 ₹2,700 |
| 3.00 | Supply and fix in repairs manual charging of closing spring and emergency hand trip assembly and testing complete all as specified and directed | 1 | Each Job | 1,600 ₹1,600 | 2,745 ₹2,745 | 5,600 ₹5,600 | 2,500 ₹2,500 | 2,800 ₹2,800 | 1,200 ₹1,200 Lowest | 2,100 ₹2,100 |
| 4.00 | Supply and fix in repairs HT bus bar with insulators as suitable for existing rating current in three phase with proper moisture proof with nuts, bolts and washer and suitable lugs with proper crimping and adequate clearance between the bus bar and earth and any fabrication as required as per site conditions by the contractor at its own cost | 12 | Set of Three | 2,200 ₹26,400 | 3,000 ₹36,000 | 1,860 ₹22,320 | 3,300 ₹39,600 | 2,500 ₹30,000 | 1,200 ₹14,400 Lowest | 2,650 ₹31,800 |
| 5.00 | Supply and fixing in repairs of 11 KV HT CTs( Primary and secondary) as per existing suitable ratio, whether wound ring or bar type with complete settings with relay, short circuit instrument, earth volt rating fault instrument ,metering equipment with transformer ratio adjustment with burden,accuracy and Overhauling of primary injection by artificial load through CT's & secondry injection of over current earth fault relays/release on each multiple setting readjustment and testing comlete all as specified and directed | 1 | Set of Three | 26,000 ₹26,000 | 20,000 ₹20,000 Lowest | 35,000 ₹35,000 | 32,000 ₹32,000 | 30,000 ₹30,000 | 24,000 ₹24,000 | 25,000 ₹25,000 |
| 6.00 | Supply and fix in repairs of 11 KV PT's both ( Primary and secondary) and apply multi grease for mechnical parts, inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts,replaced damaged insulators and testing, and assembling, allienemts of components and testing complete all as specified and directed. | 1 | Each Job | 24,000 ₹24,000 | 30,000 ₹30,000 | 36,000 ₹36,000 | 26,000 ₹26,000 | 20,000 ₹20,000 | 3,000 ₹3,000 Lowest | 22,000 ₹22,000 |
| 7.00 | Supply and fixin repairs of 11 KV HT contact assembly such as auxillary contactor(2 No+2NC) with burnt coil and all accessories and checking of electrical wiring system,and testing complete all as specified and directed. | 1 | Each Job | 1,900 ₹1,900 | 1,000 ₹1,000 Lowest | 13,500 ₹13,500 | 2,500 ₹2,500 | 2,000 ₹2,000 | 1,500 ₹1,500 | 2,150 ₹2,150 |
| 8.00 | Supply and fix in repairs phase indication 'RYB' neon lamps with all connected accessories and including LED lamp <110 volt at inside of the VCB with electrical wiring system and testing complete all as specified and directed. | 1 | Each Set | 500 ₹500 | 300 ₹300 Lowest | 1,890 ₹1,890 | 790 ₹790 | 1,200 ₹1,200 | 2,000 ₹2,000 | 600 ₹600 |
| 9.00 | Supply and fix in repairs tripping shaft assembly with coil and including springs,strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed. | 1 | Each Job | 1,800 ₹1,800 Lowest | 2,450 ₹2,450 | 3,620 ₹3,620 | 2,300 ₹2,300 | 2,500 ₹2,500 | 16,000 ₹16,000 | 1,800 ₹1,800 Lowest |
| 10.00 | Supply and fix in repairs closing shaft assembly with coil and including springs, close strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed. | 1 | Each Job | 2,500 ₹2,500 | 4,000 ₹4,000 | 5,600 ₹5,600 | 3,300 ₹3,300 | 2,500 ₹2,500 | 1,000 ₹1,000 Lowest | 2,650 ₹2,650 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
12 Feb 2026, 6:00 pmClosed
CWE (S) Barrackpore
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
REPAIR AND MAINT OF HT SWITCH GEAR, VCBs, TRANSFORMER, AB SWITCHES, 2/4 POLE STRUCTURE, HT CABLES AT BARRACKPORE CANTT UNDER GE BARRACKPORE
2026_MES_749722_1
CWE/BKP/13 OF 2025-2026
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Barrackpore
₹86,000
Yes
25 Mar 2026
23 Jan 2026
20 Feb 2026
23 Jan 2026
12 Feb 2026
6 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Checking of Instrument Panel internal wiring connections with relay,instrument transformers, metering instrument, indicating instrument, selector switches & circuit breaker control switches,CT/PT circuit wiring, earth fault circuit wiring wire not less than 1.5,2.5 4.0 sqmm etc the connections shall be securely made with the help of suitable connecting lugs duly crimped with the conductor and testing complete all as specified and directed | 4 | Each Job | - | - |
| 2 | Supply and fix in repairs 11 KV HT VCB operating mechanism with motor operated spring charged system assembly including coil assembly with 24 Volts DC auxiliary supply system works satisfactorily and testing complete all as specified and directed | 1 | Each Job | - | - |
| 3 | Supply and fix in repairs manual charging of closing spring and emergency hand trip assembly and testing complete all as specified and directed | 1 | Each Job | - | - |
| 4 | Supply and fix in repairs HT bus bar with insulators as suitable for existing rating current in three phase with proper moisture proof with nuts, bolts and washer and suitable lugs with proper crimping and adequate clearance between the bus bar and earth and any fabrication as required as per site conditions by the contractor at its own cost | 12 | Set of Three | - | - |
| 5 | Supply and fixing in repairs of 11 KV HT CTs( Primary and secondary) as per existing suitable ratio, whether wound ring or bar type with complete settings with relay, short circuit instrument, earth volt rating fault instrument ,metering equipment with transformer ratio adjustment with burden,accuracy and Overhauling of primary injection by artificial load through CT's & secondry injection of over current earth fault relays/release on each multiple setting readjustment and testing comlete all as specified and directed | 1 | Set of Three | - | - |
| 6 | Supply and fix in repairs of 11 KV PT's both ( Primary and secondary) and apply multi grease for mechnical parts, inspecting HT bushing male and female and apply dry graphite conductive sealant for contacts,replaced damaged insulators and testing, and assembling, allienemts of components and testing complete all as specified and directed. | 1 | Each Job | - | - |
| 7 | Supply and fixin repairs of 11 KV HT contact assembly such as auxillary contactor(2 No+2NC) with burnt coil and all accessories and checking of electrical wiring system,and testing complete all as specified and directed. | 1 | Each Job | - | - |
| 8 | Supply and fix in repairs phase indication 'RYB' neon lamps with all connected accessories and including LED lamp <110 volt at inside of the VCB with electrical wiring system and testing complete all as specified and directed. | 1 | Each Set | - | - |
| 9 | Supply and fix in repairs tripping shaft assembly with coil and including springs,strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed. | 1 | Each Job | - | - |
| 10 | Supply and fix in repairs closing shaft assembly with coil and including springs, close strips and connected accessories for functional requirement with electrical wiring system and testing complete all as specified and directed. | 1 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER17.pdf
Tender Documents • 1.01 MB
BOQ_839638.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .