| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-AOC PLOT NO 77 78 SECTOR I I D C ESTATE 05 SIDCUL HARIDWAR | L1 | Accepted-AOC Post Reverse Auction Bidder has emerged as the L1 bidder. | |
| 2 | L2₹75.8 L+₹7.8 L (11.5%)Rejected-AOC | L2 | Rejected-AOC Post Reverse Auction Bidder has emerged as the L2 bidder. | |
| 3 | L3₹78.9 L+₹11.0 L (16.2%)Rejected-AOC 0 BAHRAICH CITY MONTESSORI SHCOOL KANOONGOPURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-AOC Post Reverse Auction Bidder has emerged as the L3 bidder. | |
| 4 | Rejected-Technical J 99 SHIVALIK NAGAR BHEL HARIDWAR | - | Rejected-Technical As per Tender Committe recommendations | |
| 5 | Rejected-Technical | - | Rejected-Technical As per Tender Committe recommendations |
| Sl No | Description | Qty | Unit | AR Enterprises L3 | BHARAT RADIO & ELECTRIC WORKS L2 | M/s. Supertech System India Pvt Ltd L1 |
|---|---|---|---|---|---|---|
| 1.00 | WIRING FOR LED FOCUSSING LIGHT POINT WITH 2.5 SQ MM, 1100 VOLT GRADE PVC INSULATED SINGLE CORE STRANDED COPPER CONDUCTOR WIRES IN RECESSED MSHGBE CONDUIT, CHASING THE WALL, MAKING GOOD THE SAME AND COMPLETE WITH 1 NO. 12 SWG GI WIRE FOR LOOP EARTHING ETC. COMPLETE AS REQUIRED. | 10 | NO | 3,105 ₹31,050 | 2,450 ₹24,500 | 1,950 ₹19,500 Lowest |
| 2.00 | WIRING FOR MEDIUM BAY FIXTURE LIGHT AND VENTILATION FAN POINT WITH 4 SQ MM 1100 VOLT GRADE PVC INSULATED SINGLE CORE FIRE RESISTANT STRANDED COPPER CONDUCTOR WIRES IN RECESSED MSHGBE CONDUIT, CHASING THE WALL, MAKING GOOD THE SAME AND COMPLETE WITH 1 NO. 12 SWG GI WIRE FORLOOP EARTHING ETC. COMPLETE AS REQUIRED. | 112 | PT | 4,715 ₹5,28,080 | 2,950 ₹3,30,400 | 2,630 ₹2,94,560 Lowest |
| 3.00 | INSTALLATION, TESTING AND COMMISSIONING OF WALL MOUNTED TYPE DISTRIBUTION BOARD ON A SUITABLE SIZE OF ANGLE IRON FRAME INCLUDING THE SUPPLY OF ANGLE IRON FRAME WITH REQUIRED HARDWARE, MAKING CONNECTION, EARTHING AND PAINTING OF FRAME COMPLETE AS REQUIRED.THE DB SHALL COMPRISE OF THE FOLLOWING: INCOMER 100A/200A, OUTGOING 6/24 WAY. (ONLY DB WILL BE PROVIDED BY BHEL FREE OF COST) | 12 | NO | 2,070 ₹24,840 | 1,500 ₹18,000 | 1,080 ₹12,960 Lowest |
| 4.00 | INSTALLATION, TESTING & COMMISSIONING OF 16/25/35 SQ.MM ALUMINIUM/COPPER CABLE 1.1KV GRADE PVC INSULATED, PVC SHEATHED, ARMOURED/ UNARMOURED CABLE CONFORMING TO IS:1554(PART 1) LAID IN EXISTING CABLE TRENCH/CABLE DUCT/ PIPES/ ALONG THE WALL INCLUDING ALL OTHER ASSOCIATED WORKS SUCH AS CLAMPING, PAINTING ETC.AND PROVIDING CABLE IDENTIFICATION MARKERS AND CABLE NUMBER FERRULES/MARKERS OF APPROVED DESIGN, MADE OF G.I AFTER EVERY 20 METERS COMPLETE AS REQUIRED. ONLY CABLE WILL BE SUPPLIED BY BHEL FREE OF COST.ALL OTHER MATERIALS TO BE SUPPLIED BY THE CONTRACTOR.ALL WORK, CABLE ROUTE ETC. SHALL BE DONE AS PER THE INSTRUCTIONS OF ENGINEER INCHARGE AT SITE. | 2,000 | MR | 52 ₹1,04,000 | 70 ₹1,40,000 | 50 ₹1,00,000 Lowest |
| 5.00 | SUPPLY, DELIVERY, LAYING, CONNECTING, TESTING AND COMMISSIONING OF 50MM X 10MM EARTHING STRIPS, FIXING ALONG G.I PIPE/WALL/DUCT/FLOOR/IN GROUND PROVIDING G.I PIPE AND NECESSARY EARTH WORK WITH ALL ACCESSORIES, MAKING GOOD THE SAME CONFORMING TO IS:3043 AS REQUIRED | 420 | MR | 580.75 ₹2,43,915 | 900 ₹3,78,000 | 560 ₹2,35,200 Lowest |
| 6.00 | SUPPLY, DELIVERY, LAYING, CONNECTING, TESTING AND COMMISSIONIG OF 40X5MM EARTHING STRIPS, FIXING ALONG G.I PIPE/WALL/DUCT/FLOOR/IN GROUND PROVIDING G.I PIPE AND NECESSARY EARTH WORK WITH ALL ACCESSORIES, MAKING GOOD THE SAME CONFORMING TO IS:3043. | 125 | MR | 258 ₹32,250 | 450 ₹56,250 | 185 ₹23,125 Lowest |
| 7.00 | WIRING FOR 3 PHASE AIR CIRCULATING/MAN COOLER FAN POINT WITH 4 SQ MM, 1100VOLT GRADE PVC INSULATED SINGLE CORE STRANDED COPPER CONDUCTOR WIRES IN RECESSED MSHGBE CONDUITINCLUDING AIR CIRCULATING FAN BRACKET, CHASING THE WALL MAKING GOOD THE SAME AND COMPLETE WITH 1 NO. 12 SWG GI WIRE FOR LOOP EARTHING ETC. COMPLETE AS REQUIRED. | 30 | NO | 6,100 ₹1,83,000 | 1,250 ₹37,500 | 850 ₹25,500 Lowest |
| 8.00 | SUPPLY, DELIVERY, ERECTION, TESTING & COMMISSIONING OF 1.4 KVA SINEWAVE INVERTER 2X12 VOLT DC, MAKE- SU-KAM/MICROTEK OR EQUIVALENT WITH 150AH EXIDE BATTERY OR EQUIVALENT FOR ABOVE COMPLETE WITH ACCESSORIES LIKE MOUNTING BRACKET, WIRE GUARD, CONNECTORS, EARTHING, PAINTING ETC. COMPLETE AS REQUIRED. | 2 | NO | 31,625 ₹63,250 | 24,000 ₹48,000 Lowest | 32,000 ₹64,000 |
| 9.00 | SUPPLY, ERECTION, TESTING AND COMMISSIONING OF DOL STARTER OF L&T / SIEMENS / BCH /ABB OR EQUIVALENT MAKE (SUITABLE FOR 2 / 3 HP 415 V COLUMN FAN) MOUNTED ON WALL / COLUMN COMPLETE WITH MOUNTING BRACKET ETC.CONNECTIONS, EARTHING, PAINTING ETC. COMPLETE AS REQUIRED. | 34 | NO | 2,530 ₹86,020 | 2,900 ₹98,600 | 1,750 ₹59,500 Lowest |
| 10.00 | SUPPLY, TRANSPORTATION, ERECTION, TESTING AND COMMISIONING OF LED FLOOD LIGHT 40 WATT INCLUDING MOUNTING THE FIXTURE FLUSH TO CEILING WITH SUITABLE MOUNTING HOOK / BRACKET COMPLETE WITH MAKING CONNECTIONS AND LOOP EARTHING ETC.AS REQUIRED. MAKE PHILIPS/SYSKA/CROMPTON/WIPRO/BAJAJ/HAVELLS/ POLYCAB. | 10 | NO | 2,242.5 ₹22,425 Lowest | 3,000 ₹30,000 | 2,670 ₹26,700 |
Tender Value
Refer Docs
Closing Date
30 May 2025, 12:00 pmClosed
Rajeev Kumar Verma
WEX HEEP BHEL Haridwar
Internal Shop Electrification and Earthing Work for The Extension of Machine Shop and Assembly Shop Bays Under SRGM CAPEX Phase-3 In BHEL HEEP Haridwar
2025_BHEL_48303_1
BHEL/HEEP/WCS/1030/202405211
Open Tender
Miscellaneous Works
Works
420 days
BHEL HEEP Haridwar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
16 Sept 2025
12 May 2025
30 May 2025
12 May 2025
30 May 2025
12 May 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .