| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.3 L+₹1.1 L (3.76%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹31.4 L+₹2.2 L (7.56%)Rejected-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹31.5 L+₹2.3 L (7.88%)Rejected-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹32.0 L+₹2.9 L (9.88%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L5 | Rejected-AOC REJECTED |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
24 Aug 2020, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
IMPROVEMENT OF STREET LIGHT AND SECURITY LIGHT, RENEWAL/ REPLACEMENT OF DG SET AND PROVISION OF 07 IN NO AIR CONDITIONERS IN VARIOUS OFFICES AT CGDHQ-15 OKHA UNDER GE I CG PORBANDAR
2020_MES_363193_1
8534
Open Tender
Civil Works
Item Rate
150 days
DHQ-15 OKHA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I CG PORBANDAR
₹54,000
Yes
3 Nov 2020
23 Jul 2020
27 Aug 2020
23 Jul 2020
24 Aug 2020
10 Aug 2020
Amount
SCHEDULE 'A'
Excavation in trenches n.exc. 1.5 mtr wide or not exceeding 10 Sqm on plan & n. exc. 1.5 mtr deep in soft/loose soil & getting out all as specified
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply, laying, Jointing and testing 16 Sq mm 4 core XLPE insulated, Extruded PVC outer sheath and inner sheath, galvanised steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade and laid in trenches/pipe / ducts or on pole complete all as specified and directed Make: Havells/Polycab/Finolex
Supply, laying, Jointing and testing 95 Sq mm 3.5 core XLPE insulated, Extruded PVC outer sheath and inner sheath, galvanised steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade and laid in trenches/pipe / ducts or on pole complete all as specified and directed Make: Havells/Polycab/Finolex
Taking out unserviceable LT UG cables of 16 Sqmm 2 Core from trenches all as spd.
Taking out unserviceable LT UG cables of 95 sq mm 3.5 core from trenches all as spd.
Supply and install 7m long Octagonal hot dip galvanized iron pole with base plate, 300mm long weather proof reinforced door opening with junction box mounting arrangement, inbuilt junction box, 'J' shape, EN8 foundation bolt with nuts template including RCC foundation as per manuacturer's design conforming to IS 1786. The foundation shall extend above surrounding levels by 200mm all as directed by Engineer-in-charge. Make :Wipro/ Surya/ Crompton Greaves/ Bajaj / Utkarsh NOTE :The contractor should submit manufacturer's foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate. Location: DHQ No. 15 Okha
Dismantling of concrete Poles/ Struts of any size
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings complete all as spd and directed.
Supply and fix and testing Street Light automatic Nature switch for three phase load of 5 KW using infrared sensor based Timer switch including the sensor should have part night operation facility of minimum 04 hrs to maximum 12 hrs, the sensor along with 03 Nos ctactor each of 20-25 A incoming MCB and out going MCB's of 20-25 A (03 Nos) and auto maunual (senser by Pass), size of circuit should be multistanded FRLS min size of 10 SqmmWall Mounted / Pole mountable enclosure made of rust proof, electric shock proof, (sitex made SMC Junction box) confirming to IP 54 and Model Swadeep 02 EC 5KW 3P, all as specified and directed. Make: Nature switch: Kakatiya Energy system/ Bajaj/ Healer.
S & F 35/36 Watt LED street light luminaire, spun housing, aluminium/ die cast grey finish power coated body, clear arcylic cover, rated Voltage 240 Volt ,50 HZ, operating voltage Range 120-270 Volt , nominal lumen efficiency 120 lm/watt, IP-65/66 Prtotection with mounting clamps, bolts and nuts, fixed to vintage type bracket as specified with pole complete all as specified and as directed Make: Philips (BRP052 LED 036 CW HP SLA FG S1 PSU GR)/Wipro (Skyline+LR13-501-xxx-57-xx)/Osram Lux power ST G2 35 Watt CW 20 x 1 AM 3100100GF
M&L sub main wiring with three runs of 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T.
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
Supply, Install, test and commission of 100 KVA capacity diesel Engine driven generating set , 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enlcosures (should have slient features) modular bolted construction & pure polyster based coating to ensure long life in all weather conditions& for outdoor appliaction/installation, integrated deisgn, thereby facilating/easy handling all as specified & comprising of following Specification :- (a) ENGINE- Water cooled diesel engine 1500 RPM, 126 HP (Min) , as per IS:10000/10002 direct injection turbo charged after cooled, Governing type G3, including standard accessories with engine control panel comprising of microprocessor based controller, 12V electrical system with battery. (b) ALTERNATOR - Alternator, cap 100 KVA, 3 phase, 4 wire, 415 volts, 1500 rpm brushless, self excited, self regulated with automatic voltage regulator, excitation band or voltage +/-1 % from no load to full load clas H insulation, PF 0.8 with standard accessories and confirming to IS (c) Acoustic Enclosure: Sound proof acoustic enclosure fo DG Set mounted on AVM with silencer and SS Exhaust below suitably optimized to meet stringent sound emission standards as laid down by CPCB-II Noise limit < 75 dbA,at 01 Metre distance (d) AMF Panel: Automatic starting on main failure, control panel with LCD Dispaly parameters (oil pressure, Fuel level, Voltage, Current, PF, Battery voltage, RPM, Coolant temp, KWhr and KW), Audio coolant Temp) including hinged door, with copper bus bar,200 Amp, 3 Phasr 4 wire system, including (i) MCCB 160A, FP, 36 KA, microprocessor based -02 Nos, (ii) Power contractor FP 160 A-02 Nos (iii) Microprocessor based Relays etc. MAKE FOR ENGINE : GREAVES / KIRLOSKAR / ASHOK LEYLAND /CUMMINS MAKE FOR ALTERNATOR : CG,JOYTI, STAMFORD
NOTES FOR ITEM NO 15 : (i) Cost of PCC foundation as per manufacturer design deemed to be included in unit rate. (ii) AMF Panel should be enclosed in Acoustic enclosure. (iii) Cost of control cable deemed to be included in unit rate. (iv) DG set shall be procured from OEM mentioned above.
M&L Earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI Wire 4mm dia as earthing lead (upto the test point ) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected upto test point and GI pipe light grade 20mm bore for watering and including funnel , wire mesh , PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, RCC pit cover type B-1 including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and as directed by Engineer-in-charge. NOTE : Earth wire upto 7.5mtr length is deemed to be included in quoted rate.
Supply and lay 90 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cables with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Geminii
Supply and lay 63 mm outer dia double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cables with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) Make: Rex/Poly/Geminii
Supply install and test 2.0 ton capacity split type AC consisting indoor/outdoor units, with cordless remote control unit, Inverter type, with copper condenser ,3 star rating, EER not less than 4.5, indoor noise level <50db with standard fitments and outdoor unit fixed with wall mounted bracket and accessories all as directed by Engineer-in-Charge. Make : Voltas (243VEZL), Carrier (Copper Esko+Hybridjet INV R410 CAI 124EK3R49F0 White), Hitachi (RMC322HBD)
SS& F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB DP 20A,10 KA C Series complete all as spd and directed Make Legrand/Siemens/Schneider
Gatral Construction Co.
vijay infraprojects pvt ltd
Harsh Infrastructure
OM ENGINEERING
SHREE CHAMUNDA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .