Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.9 Cr+₹39.5 L (11.4%)Rejected-Finance | ₹3.9 Cr+₹39.5 L (11.4%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹3.9 Cr+₹45.9 L (13.3%)Rejected-Finance | ₹3.9 Cr+₹45.9 L (13.3%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹4.4 Cr+₹91.2 L (26.4%)Rejected-Finance | ₹4.4 Cr+₹91.2 L (26.4%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹4.4 Cr+₹97.8 L (28.3%)Rejected-Finance | ₹4.4 Cr+₹97.8 L (28.3%) | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹7.1 L
Closing Date
21 Jun 2021, 3:00 pmClosed
CCERnD SOUTH SECUNDERABAD
CCERnD SOUTH PB NO 1569 AKBAR ROAD SECUNDERABAD 500009
PROVISION OF CIVIL WORKS AND ALLIED SERVICES FOR CONSTRUCTION OF PRODUCT DISPLAY CENTRE AT NSTL, VISAKHAPATNAM
2021_DRDO_631408_1
83598/NSTL/CIV/CON
Limited
Civil Works
Item Rate
365 days
NSTL VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹2,000
Yes
CCERNDSOUTH
₹7.1 L
Yes
16 Nov 2021
28 May 2021
22 Jun 2021
28 May 2021
21 Jun 2021
12 Jun 2021
29 May 2021 - 7 Jun 2021
Amount
SUB HEAD-1 - BUILDING INCLUDING INTERNAL SERVICES SUB HEAD-I - EARTH WORK & ANTI-TERMITE TREATMENT
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
SUB HEAD-II - REINFORCEMENT AND PLAIN CEMENT CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand(Zone III) derived from natural souces : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural souces : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Extra for shuttering in circular work
Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of engineer In Charge for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level, Concrete of M25 grade with cement content of 330 kg /cum
All works above plinth level upto floor V level, Concrete of M25 grade with cement content of 330 kg /cum
Extra for providing richer mixes at all floor levels.
Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
SUB HEAD-III - BRICK & STONE WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 12mm dia and below. M.S. bars at every third course of half brick masonry.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand ).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
SUB HEAD-IV - STEEL & WOOD WORK
Providing and fixing rubber wall buffer for doors of size 50mm. Long including necessary screw etc. Complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing pressed steel door frames conforming to IS: 4351, from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile C
Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of as per required size, joints mitred and welded by angle iron as per required flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings, the directions of Engineer-in-charge and details adhering to approved shop drawing, submitted by the contractor. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws. (Glazing, paneling and dash fasteners to be paid for separately) :
For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber, wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately, Only weight of aluminium sections to be measured for payment).
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Float glass panes
4 mm thick glass pane (weight not less than 10 kg per sqm)
Extra for providing etched glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding,
cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.96 to 102)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and fixing glass reinforced concrete pattern, design thickness and color of M\S (G.R.C) Screens in approved size, UniStone make or equivalent, The Screens be made ’53 grade’ White Portland cement by JK Cement’ or equivalent, Quartz, fine silica sand, alkali resistant glass fiber by Saint Gobain’ or equivalent , super plasticizers by BASF or equivalent polymers by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation by BAYFERROX (Germany), or equivalent. The material casting should take place in synthetic rubber/ FRP Mould by ‘Reckli’ or equivalent. The fixing or screens should be dry fixing i.e. to be done with stainless steel ‘L’ shaped clamps, dash fasteners and pins.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
SUB HEAD-V- FLOORING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand ), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Tiles should be of premium quality as approved by Engineer -In-Charge
Providing and laying antiskid rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand ), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.Tiles should be of premium quality as approved by Engineer -In-Charge.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Tiles should be of premium quality as approved by Engineer -In-Charge.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Tiles should be of premium quality as approved by Engineer -In-Charge.
Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
18 MM. thick polished grenite stone work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
SUB HEAD-VI - ROOFING WORK
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes
110 mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand ) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm
and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
SUB HEAD-VII - PLASTERING &FINISHING WORK
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand )
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand finished rough with sponge.
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand
Extra for providing and mixing water proofing material in cement .Per bag plaster work in proportion recommended by the manufacturers
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Dsitemper should be of premium quality as approved by Engineer -In-Charge
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with textured exterior paint of required shade :Paint should be of premium quality as approved by Engineer -In-Charge
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade :
New work (three or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
French spirit polishing :
Two or more coats on new works including a coat of wood filler
SUB HEAD-VIII - INTERNAL WATER SUPPLY & SANITARY INSTALLATIONS WORK
Providing and fixing white vitreous china wall mounting water closet of size 570x340x360 mm of approved shape including providing & fixing PVC concealed cistern of Size 460x450x80mm with dual flush plate fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc including painting of fittings and cutting and making good the walls and floors wherever required : complete.make Hindware cat Nos-92097
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and .
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm. make JAQUAR ACN-1111N or eqv.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing soap Dish Holder with concealed fitting arrangements.Make Jaquar ACN-1131N or eqv.
Providing & fixing CP brass Health faucet with PVC Flexible Tube with wall hook.( JAQUAR MODEL NO-573 or Equilent.)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing unplasticised Polyvinyl Chloride (UPVC) pipes, having thermal stability for hot & cold sewage supply including all UPVC plain fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, & testing of joints complete as per direction of Engineer in Charge.Toilet Sanitary pipe work
100 mm nominal inner dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
32 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
25 mm diameter pipe
32 mm diameter pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
SUBHEAD-IX- INTERNAL ELECTRIFICATION
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class FRLS PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.
Group-C
Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 2mm thickness FRLS PVC ISI mark conduits concealed in wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
Two Lights point controlled by one 6A switch.
Four Lights point controlled by one 6A switch.
Exhaust fan point controlled by one 6A switch including ceiling Rose.
One ceiling fan point controlled by one 6A switch With 100W step type Electronic regulator including Concealed MS fan hook box.
Call bell point with 6A Bell push with Buzzer
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed heavy FRLS PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 1 nos. 15/16 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting with Lamp Control Gear & Fixing Accessories. All fixtures shall be white colour & supplied with white lamps. All the light fixtures will be finally approved by Architect / Consultant/ Department. Architect / Consultant / Department reserves the right to reject the fittings suggested by the contractor.
18W (4Feet) LED Light Fixture (Philips : BN021C LED40S PSU CDL GR)
15W LED surface mounted fixture (Philips : SM251C LED20S SLEEK SURFACE)
80w,DuraLED Highbay ,Aluminum die–cast, Gray color, Safety class I (I), 50 Hz, 140-270 V, IP66 [ Dust penetration-protected, jet-proof], IK08 [ 5 J vandal-protected], Surge protection level until 4 kV, Philips Cat No.- BY325P LED100S CW PSU GR FG NB XTFCL V1
36W LED recess mounted fixture (Philips : RC380B LED30S-6500 L60W60 PSD OD S1)
8W Mirror light Surface Mounted MAKE-PHILLIPS CAT NO. BN021C LED22S PSU CW GR or eqvl.
Philips EnduraLED Bulkhead,IP-66, WT202W LED10S CW PSU S3 PC
Ceiling Fans
Supply and fixing of Ceiling fan of following sweep (white colour), suitable for operation on 230 / 240V, 50 Hz, single phase, A.C, supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
1400mm Sweep Ceiling fans
Exhaust Fans
Supply, Installation & Testing of following 900 RPM exhaust fan suitable for single phase, 240V, AC supply complete with motor, MS louvers, mounting brackets all accessories etc complete.
300mm Sweep
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummys for spare ways in the DB (No claim shall be allowed for the same).
6Way TPNMCBDB with 40A, 100mA 4Pole RCBO as incomer and 15nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings.
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUB HEAD-2- FURNITURE
Providing and placing in position multti purpouse table of Size 1800x900x740mm. The work top should be 25mm thik pre-Lemineted particle board with post foming profile edge of required colour and texture as approved by Engineer-in-charge. Fixed on 35x35x3mm Stainlees steel 202 angle frame the Legs & footrest should be of 38mm dia Stainlees steel pipe with adjustable nylon bullet. the welded joint should be ground smooth and polished complete Make: Godrej, Model. Insight 1800W all as per the directions of Engineer-in-charge.
Supplying and placing in position of Revolving chair of size 760w x 760D x 850-950H mm. the seat & back made from 12mm thick hot pressed plywood and upholsterd with frabic and moulded polyurethane foam. The back foam is designed with contoured lumber support for extra comfort. the seat size: 470W x 480D mm and back size 470mm W x 580mm H . The HR polyurethane foam is moulded with density of 45+/-2kg per meter cube and hardness load of 16 +/-2kgf as per IS 7888 for 25% compression. The Armerest should be of one-piece armrest are fitted to the seat are injection moulded black copolymemer. there should be a synchrnous tilt mechanism designed with 360 degree revolving type and upright locking.there should be gas lift having height adjustment of stroke of 120mm. Below should have 3 piece telecopic type and injection moulded in black polypropylene. the ped should be injection in black 30% glass-filled nylone and with 5 twin wheel castore in injection moulded type of black nylon. the ped of 660mm +/- 5mm pitch-center dia. approved make: Godrej Modal BRAVO or eqv. as approved by Engineer-in-charge
Supply and placement of leatherite Double seater sofa of size 1100mm (L) x 800mm (D) x 800mm (H) made out of 19mm ply wood frame work partially upholstered having seat and back with foam of 30kgs/cum and 28 kgs/cum with no spring in the base/seating.Seat shall have the foam thickness of 100mm and back with 60mm thk.Arm width and height shall be 100mm x 600mm.Seat and back rest are permanantly fixed with the frame structure.Seat cushion shall have a length of 1000mm with a width of 510mm. Back cushion shall have a length of 1050mm with a width of 508mm etc; (Make Godrej Model pisa.)complete all as per the directions of Engineer-in-charge.
Supply and placement of leatherite Single seater sofa of size 850mm (L) x 850mm (D) x 750mm (H) made out of 19mm ply wood frame work partially upholstered having seat and back with foam of 30kgs/cum and 28 kgs/cum with no spring in the base/seating.Seat shall have the foam thickness of 100mm and back with 60mm thk.Arm width and height shall be 100mm x 600mm.Seat and back rest are permanantly fixed with the frame structure.Seat cushion shall have a length of 1000mm with a width of 510mm. Back cushion shall have a length of 1050mm with a width of 508mm etc;(Make Godrej Model pisa.)complete all as per the directions of Engineer-in-charge.
Supply of Centre Table of size 900 x 525 x 400 mm made out of 50 x 50 mm teakwood legs with necessary frame work, top to have 10mm thick glass fixed to SS studs etc., (make Godrej)complete with Melamine polish and all as per drawing and as directed by Engineer -in-charge.
SUBHEAD- 3 - AIR CONDITIONING VARIABLE REFRIGERANT FLOW ( VRF)
OUT DOOR UNITS ( CONDENSING UNIT)
Supply, Installation, Testing and commissioning of VRF system with DC inverter compressor technology. The system shall be complete with indoor unit, condensing unit, Controls, Micro-processor controls, individual temp control of each indoor unit, control panel, wiring, refrigerant piping, insulated Drain pan low noise condenser fan coupled with variable speed motor, auto check-function for connection error, auto addressing Including required no. of multi connection piping kit . and all accessories required for smooth operation of the system. The Refrigerant gas should be R410A and capable of cooling as well as Heating ( Heat pump ) The system shall be complete with inrconnected refrigerant piping , full charge of R-410 refrigerant gas & oil, control cabling, M S framework for mounting the condensing unit, on terrace Fabricated out of steel channels of adequate st rength. The unit shall be mounted on framework by means of 8mm thick neoprene type vibration isolators.etc.
Supply, Installation, Testing and Com missioning of condensing units with air cooled condenser with scroll compressor, Inverter Control with stepless modulation for precise capicity control of frequency differential of 1 hz, system should have oil seperation and return mechanism to ensure complete oil recovery & outdoor units should have minium 20-27 steps / VFD in ODU fan motor for the stability of suction and discharge pressure and quick response to IDU temperature control, scope includes inrconnected condenser refrigerant piping, control panel cabling etc. The prices should include lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/ oil required for first charge should be included in the individual price quoted below.
22 HP Out Door Unit (2Working + 1 Stand By)
28 HP Out Door Unit (Double floor height area Working )
INDOOR UNITS ( EVAPORATIVE UNIT)
Supply, Installation, Testing and Commissioning of indoor units complete with blower, cooling coil, insulated drain pan, air filter of efficiency 80% down to 20 microns. Scope includes supporting framework for mounting of indoor unit fabricated out of steel channels of adequate strength complete as required. The entire framework shall be duly primer coated and painted black. The Min Capacity of IDUs shall be as specified under. (Min Capacity)
4-Way Cassette Unit complete with drain pump.
Ceiling Suspended Ductiable AC
Supply, installation, testing & commissioning of Air Cooled VRV/VRF Ceiling mounted built-in type/ ductable type Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, electronic expansion valve, outer cabinet, drain pan, insulation, including y joints pipe connections, control and power panel with codeless remote control etc. of various capacities as per specifications & drawings.
Treated Fresh Air Unit complete with drain pump.
Supply, Installation, Testing and Commissioning of Ceiling hung ductable indoor unit with evaporator coil, fan section with low noise fan, multispeed motor, outer cabinet, drain pump, drain pan, spring isolators for hanging arrangement, corded remote controller mounted inside powder coated MS box, pre-filter, silicon coated flexible duct connection, etc. complete as required. The minimum fan external static should be 200Pa. Each IDU shall have mixing box for connecting fresh air to unit complete with provision to clean filters. (Remote to be quoted separately)
Supply, Installation, Testing and Commissioning of Y-joints and T joints of required sizes for SUB & connections of refrigerant pipes to units.
Controller
Supply, Installation, Testing and Commissioning of corded remote controller
Supply, Installation, Testing and Commissioning of cordless remote controller
Supply, Installation, Testing and Commissioning of 4 star Inverter Hiwall split unit complete with ODU & IDU. The condensing unit shall be with air cooled condenser with scroll compressor, with Hi wall indoor unit consisting blower, cooling coil, air filter of efficiency 80% down to 20 microns & insulated drain pan. Indoor units should have wireless / corded Remote Cont roller as a standard accessory. (Min Capacity)The prices should include lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/ oil required for first charge should be included in the individual price quoted below.
Refrigerant Piping
Supply, Laying, testing and commissioning of copper refrigerant piping inside the building (including circuit of liquid & suction-0.8 mm thickness for soft pipe up to 19.1 mm dia and 1.0 mm for hard pipe above 19.1 mm dia) duly insulated with 19 mm / 13mm thick pre-formed moulded sections of closed cell XLPE insulation of class 'O' fire rating having uniform density not less than 25 kg/cum, with necessary support & accessories complete in all respects for following sizes.
31.8 mm dia / 19 mm thick insulation
28.6 mm dia / 19 mm thick insulation
25.4 mm dia / 19 mm thick insulation
22.2 mm dia / 19 mm thick insulation
19.1 mm dia / 13 mm thick insulation
15.9 mm dia / 13 mm thick insulation
12.7 mm dia / 13 mm thick insulation
9.5 mm dia / 13 mm thick insulation
6.4 mm dia / 13 mm thick insulation
Drain piping
Supply, Installation, Testing and Commissioning of Hard PVC Drain piping with drain t rap & insulated with 6mm thick make Nitrile Rubber Sleeve insulation with necessary tees, elbows and fit t ings. All drain piping shall be firmly supported by M S painted angles from ceiling.
25mm Dia
32mm Dia
AIR DISTRIBUTION :-
Supply, Fabrication, installation, testing, balancing and commissioning of GSS sheet metal ducting complete with elbows, split ters, vanes, hangers, supports and rubber gasket sealing as per approved drawings. GSS ducting :- as per IS- 655/ 1963 revised t ill date required for dehumidified air distribution.
Supply, installation, testing & commissioning of extruded aluminium constructed continuous linear Grill.
Supply, installation & balancing of Volume control device at supply / return air grill complete with nuts bolts, screws, linkage, flanges etc.
Supply, installation & balancing of duct mounted Volume control dampers at supply / return air duct complete with nuts bolts, screws, linkage, flanges etc.
Providing & fixing fire proof double layered canvass cloth connection for Ductable split indoor unit outlet complete with flanges made out of 22G G.S.S sheet complete with nuts, bolts etc.
Supply, installation, testing & commissioning of Fresh air intake louvers duly powder coated (of approved colour) made of extruded aluminium profiles construction, complete with Box type volume control damper in aluminium construction with 3-5% leakage at 50mm pressure differential, multi-layer wire mesh filter
INSULATION :-
Supply and application of Thermal insulation of supply air ducting with factory faced Al. foil Nitryl rubber insulation material 13 mm thick.
Supply and application of Acoustic lining of supply air ducting complete with G.I frame, t issue paper, 28G perforated al. Sheet , 25mm thick 32kg/ cu.m fibreglass insulation of thickness
ELECTRICAL
Supply, installation, testing and commissioning of following MCBs including outdoor box & electrical connections etc complete.
63Amp 16 KA TPN MCB for 24 HP & 28HP ODUs
Supply , laying , Testing and Commissioning of 2C x 1.5sqmm copper multistrand wire in & including 25 mm dia FRLS PVC conduit as per manufacturers specifications.
Supply, laying , Testing and Commissioning of following PVC insulated Copper conductor armoured cables 1100 volts complete in cable tray, clamps, saddles, cable glands, thimble etc. including effecting proper connection to the equipment as required.
4c x 25 Sq.m m for 24 HP ODUs
ELECTRICAL Panel
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted outdoor panel MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 25KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only.
ODU panel. ( on terrace )
Incomer - 250A 4P MCCB (25 KA) with Microprocessor based release unit with Protection:-1 set
0-500 Volts, digital Voltmeter and shall be protected by 2Amps MCBs. -1 set
0-250 Amps digital Ammeter -1 set
Phase indicating lamps and shall be protected by 2Amps MCBs.
Each incomer / outgoing multifunction meter with RS485 connectivity.
Bus Bar:
300 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves - 1 set
Outgoing:
All Outgoing Shall have 16 KA rating .
15 Nos. 10 Amps DP MCB 16KA with For IDU with ON/OFF Indication.
5 nos 63Amp TPN MCB for ODUs
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD-4 - POWER WIRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed heavy class FRLS PVC conduit as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummies for spare ways in the DB (No claim shall be allowed for the same).
6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 21nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings.
Supply installation testing and commissioning of Vertical type MCB Double door Distribution boards dust and vermin protected and AC supply operation including incoming MCCB/ MCB/ ELCB / RCBO as per specifications and required capacity Neutral bar and Earth Terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface on wall including all fixing materials required. All MCBs shall be "C" Curve
4Way VTPN MCBDB with 100A, 25kA 4 Pole MCCB as incomer and 3Nos 63A 4TP MCBs, 1 Nos 40A 4TP MCBs, as outgoing.
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD -5- SHOP ELECTRICALS
Supply and laying of following dia. NP2 grade RCC hume pipes with collars for road crossings, laid 750mm below ground level including excavation, back filling etc., complete.
100mm dia.
300mm dia.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
80 mm dia
100 mm dia.
Supply and fixing of following HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461, Steel wire mesh cable trays with internal dimensions & load bearing capacities as given below, including couplers, mounting accessories with including all fixing accessories and including 2runs of 25x5mm GI strip along with cable tray etc., complete as required.
150mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 29.51KG/meter at the span of 1.5Meter.
300mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 57.66KG/meter at the span of 1.5Meter
RACEWAY
Supply, installation, testing and commissioning of following sizes PVC raceway with cover - above and below floor/ceiling / wall as per direction of engineer in charge with necessary supporting to distribute Power, Data and Telecom cables including junction box, riser, coupler etc including all accessories.
100 x 38mm two compartment
150 x 38mm three compartment
MV Panel
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/ Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength / ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door. Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/ Hylam/ Bakellite sheet inside the panel for partitions or any other purpose.
Incoming :
400A, 50KA 4pole MCCB with O/C, S/C & ELR with CBCT & 400A FP Power contactor - 1sets
Busbars :400A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
250A 25KA TP+NL MCCBs –2no for AC System. (1 Spare)
100A 16KA TP+NL MCCBs – 1nos (For V.DB )
40/63A 10KA TP+NL MCCBs – 1nos ( For Area Lighting Future Provision
65A AC1 Contactor with 230V Coil and a Time
Switch similar to L&T TSQ 100 -1set
63A 16KA TP+NL MCCBs – 3nos (For 2nos fire panals +1 lift +1 Spare )
40A 16KA TP+NL MCCBs – 2nos (For 1 equipment.+1 Spare )
40A 10KA DP MCBs - 1nos (Spare)
Note: All incoming & outgoing Metering instrument Complete as required
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD - 6 - TELEPHONE CONDUITING
Supply and laying of 25mm dia, heavy duty FRLS PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required.
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate etc. complete as required.
Supply and laying of following pair 0.5mm dia PVC insulated unarmoured copper conductor Telephone wire in existing conduit conforming to DOT Specifications.
Supply and installation of following size Krone connectors in MS box complete as required.
Supply and laying of following pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and fixing of Data outlet (RJ45) with anodised GI box with front plate etc. complete as required
Supply and laying of UTP 4 Pair CAT 6 LAN Cable in existing conduit complete as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 150 mm X 60 mm deep
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
80 mm dia
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD - 7 - EARTHING
Providing maintenance free Earth station with consisting of
- 65mm dia, standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs.
- Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule.
- Brick chamber & CI Cover complete.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and laying of bare GI tape off the following earthing clamped to wall with suitable clamps saddles and fixing bolts/soldering /riveting in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043:1987. All joints shall be tined.
50 x 6 mm GI strip
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD -8- FIRE ALARM SYSTEM
Supply and fixing of Double Loop addressable control panel with Loop Driver card, complete with Batteries for 30 mins backup in normal condition + 10 mins backup with 25% Loop under fire condition. Complete as required
Supply and laying of twisted pair 1.5sq.mm shielded FRLS insulated copper conductor flexible wire through existing MS Conduit.
Supply and fixing of 25mm dia 16SWG MS conduit concealed/ Surface in wall/ Ceiling/ above false ceiling including painting with 2 coats of Red colour paint for exposed part and all fixing accessories/ materials
Supply and fixing of Multi-sensor combined optical smoke sensor and thermal sensor in a single housing with base .
Supply and fixing of Remote response indicator having twin LED flush mounted on false ceiling/wall of same make as detectors and panel.
ADDRESSABLE BEAM DETECTOR
Supply and fixing of Intelligent Addressable Double Action (One Stage) Fire Alarm Station MCP (manual call point).
Supply and fixing of Addressable horn-strobe, hi/lo db with base .
Supply and fixing of Intelligent Addressable Output control module for fire integration with Access control, PAC, Gas suppression etc. and third party fire alarm panel integration.
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD -9- LIGHTING PROTECTION SYSTEM
Supply and installation of vertical air termination with 40mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper rod including PCC block and all fixing accessories.
Supply GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Supply and laying of following size earth strips the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth necessary interconnections with earth station and equipments.
50 x 6 mm GI Strip laid in Ground
Supply and laying of following size earth strips with all fixing accessories when laid on the parapet & terrace with necessary interconnections with earth station and equipments.
25X5mm Aluminium strip conductor with DMC Insulated Supports
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUB HEAD -10- FIRE FIGHTING SYSTEM
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal end section top discharge centrifugal close coupled pump set CI casing Bronze impeller SS shaft pump set with all accessories complete as required and directed by Engineer In-charge
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
450lpm 35m head ( 1Working + 1 Stand By)
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal /Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
100mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
100mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 Meter
Providing and fixing ISI Marked of approved make Fire Extinguishers complete with all accessories as per manufacturer's specifications.
CO2 gas nozzle type - 4.5 Litre capacity (IS:15683).
Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+ -10%) containing lumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats anchor fasteners etc. complete in all respacts as diercted by Engineer-in-charge
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUBHEAD -11- LIFT SYSTEM
Supply, erection, testing and commissioning of electic passenger lift of 544 Kgs. capacity to serve Ground to first floors ( total two stops & two opening ) with a total travelling length of approximately 8.0 mtrs. including elevator, VVVF drive, machines, controllers, car body, car guides, landing doors, counterweights, main suspension steel rope, cabling, safety device, three side glass panel and governer, automatic sliding doors for car and landing hoist way with full height IR sensor, buffers for car and accessories including intermediate supporting channels/ brackets for car guides with all allied works and scaffolding etc. and supply, erection, testing and commissioning of automatic rescue device (ARD) system operating on 4x12 V - 24 AH dry maintenance free batteries with 10 second actuation time and automatic switch over facility including all neccessary cables and termination etc. complete.
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUB HEAD-12- ROADS , PAVEMENTS AND DRAINS
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:4 (1 cement: 4 fine sand)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Good earth
Moorum
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate,watering and compacting to the required density .
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler,cleaning and preparing the existing road surface as per specifications :
On W.B.M. @ 0.75 Kg / sqm
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.
New work (Two or more coats)
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints etc. complete :
150 mm dia. R.C.C. Pipe
300 mm dia. R.C.C. Pipe
450 mm dia. R.C.C. pipe
SUB HEAD-13- EXTERNAL WATER SUPPLY
Supply, erection, testing and commissioning of G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External work
32 mm dia nominal bore
50 mm dia nominal bore
Making connection of G.I. distribution branch with existing G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
32 mm nominal bore.
50 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand ) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
32 mm diameter pipe
50 mm diameter pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
300 mm dia. R.C.C. Pipe
Supply and fixing water supply route marker with route indication on 150 mm. dia. Cast iron disk bolted in 40x40x3mm. angle iron grouted in 1:3:6 concrete block 150x150x300mm. deep including two coarse of aluminum paint on metal work.
SUBHEAD-14 - EXTERNAL ELECTRICAL POWER SUPPLY
MV Cables
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable.The cable shall conform to IS 7098/ Part I.
3.5C X 300 Sq.mm
3.5C X 120 Sq.mm
3.5C X 70 Sq.mm
3.5C X 25 Sq.mm
4C X 16 Sq.mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUMEI METAL pipe as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and fixing cable route marker with route indication on 150 mm dia cast iron disk bolted to 40x40x3mm angle iron grouted in 1:3:6 concrete block 150x150x300 mm deep including two coats of aluminium paint on metal work.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 240 sq. mm (62mm)
3½ X 120 sq. mm (45mm)
4 X 25 sq. mm (28mm)
4 X 16 sq. mm (28mm)
Note: 1. The models indicated in each item are for reference only. Any equivalent or superior model may also be proposed. 2. In any case the model shall be of premium quality and approved as per the directions of Engineer-in-Charge
SUB HEAD-15 - SEWAGE DISPOSAL
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement :1 fine sand ) including testing of joints etc. complete :
100 mm diameter
150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
100 mm diameter S.W. Pipe
150 mm diameter S.W. Pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150 x 100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints etc. complete :
250 mm dia. R.C.C. Pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of cass designation 7.5
Extra for depth for manholes
Size 120x90 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
SUB HEAD-16-ARBORICULTURE/ LANDSCAPING
AVENUE TREE PLANTATION
Digging of pits / holes of size 1m dia and 1m deep in all kinds of soil and refilling the with the excavated earth & supplied good earth whenever required mixed with manure or sludge in the ratio of 2:1 by volume (2 part of good earth : 1 part of manure ) additives , anti-termitetreatment and manure (cost include). Flooding with water , dressing include removal of rubbish and surplus excavated earth, if any with all leads and lifts (extra gooth earth if needed to be paid for separately after the reduction by 20% )
Supply & plantation of flowering or foilage or desired ,well grown Tree of 6'-8' height sapling with disease / insect free , good foilage and stem girth. Staking theTree sapling with bamboo stakes of same height & 25mm thick, treated with anti termite solution & fixing in position, tie with stick at two suitable places. After plantation tree saplings & bamboo staking are to be maintained for 180 days as the minimum guarantee period including replacing the casualties with the same size and girth of tree sapling if any.
List of trees are as following :-
(i) Avenue Flowering Tree:- Rain Tree / Peltophorum / Cessea semia / Bottle Brush or equivalent.
(ii) Decorative Tree:- Bottle Palm / Fish tail Palm / Pougoville / Traveller Palm / Ashoka / Plumeria Alba / Ficus benjamina / F.Rejnold & equivalent.
HEDGE PLANTATION
Preparation of beds/ trench for hedging by excavating 60 cm deep x 45 cm wide x RM in length in all type of soils. Refilling the excavated earth after breaking clods and mixing with sludge or organic manure in the ratio of 5:1 (Five part of good earth and one part of organic manure ) flooding with water, filling with earth if necessory ( good earth paid for separately on actual measurement basis after the reduction of 20% its volume). Levelling and fine dressing for planting hedge sapling .
Supply and plantation of approved hedge species like Golden duranta / Cholorodendron inermie sapling in staggard condition of 1' height after the plantation, about 1-2 years old with well grown, disease / insect free and plantation the minimum 07 number of sapling per running metre. Maintenance for a period of 180 days as the minimum guarantee period.
ORNAMENTAL PLANTS
Supply and plantation of ornamental plants including digging of pits size 60 cm dia and 60 cm deep. Mixing of organic manure in the ratio of 3:1 (three part of good earth and one part of organic manure ). Plantation of the approved varieties of Ornamental plant sapling, it should be well grown, disease / insect free. After plantation plants are to be maintained for a period of 180 days including replacing the casualties with same size & age of plant if any.
Washingtonia palm 3'-4' ht..
Ficus Black 5-6' ht, bushy & well developed
SEASONAL FLOWER BED
Preparation of bed as per the item 2 (a) shrub plantation in beds except the plantation seedlings of seasonal flowers with 10 cm to 30 cm (small to large flower sapling) apart Seasonal flower beds to be shown freshly in every flowering season.
NOTE: 1) Certain Scheduled items like Earth Work , PCC (1:2:4, 1:4:8), RCC, Reinforcement steel, RR Masonry, pointing, etc.,,,repeated in various sub heads, Bidder is requested to quote the same rate for similar items. However , if there is any veriation in rates quoted by Bidder in similar items under different sub heads, the lowest rate shall be considered. 2) Wherever written for sand should be read as sand.
K Kumar Raja Projects Pvt Ltd
RIC Projects Pvt. Ltd.
B. DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
Hi-Tech Infrastructure
NIMMA NARAYAN ENGINEERS & CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .