Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.4 L+₹5.4 L (33.7%)Rejected-AOC 3 VIJAY PARK CHAKRATA ROAD DEHRADUN 248 001 UK | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
15 Dec 2020, 6:00 pmClosed
GE IMA DEHRADUN
GE IMA DEHRADUN
PROVN OF SHED SAND PIT RAIN WATER DRAIN PIPES VARIOUS ATTACHMENTS IN SANITARY ANNEXE GARBAGE BINS AND INTERLOCKING TILES AT DIFFERENT LOCATION AT IMA DEHRADUN
2020_MES_390904_1
GE/IMA/61/2020-21 9005/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA DEHRADUN
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA DEHRADUN
₹38,000
Yes
12 Jan 2021
29 Oct 2020
17 Dec 2020
30 Oct 2020
15 Dec 2020
1 Dec 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in post holes each n.exc 0.5 cum and getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layers watering & removing surplus soil to a distance n.exc 50m & making good surface in any type soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
PCC 1:3:6 typeC-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
Rolled mild steel work in joist, channel, angles or tee section fixed independently without connecting plates etc complete all as specified and directed.
Mild Steel work as in angle/Tee/ hollow/ tubular section as in vertical post, rafter, purlin etc including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S 1161 Gde st 240 complete all as specified and directed.
Rolled mild steel work in roof trusses (framed), trussed, purlin crane gantries, rails and fastenings etc including distance pieces plates cleats etc complete all as specified and directed.
Mild steel plates (plain or chequered) channels square cut or notched (ordinary or counter sunk forming holes with rveted bolts or welded attachment confirming to FE-290 Gde E-165 complete all as specified and directed.
Expanded metal or welded steel wire fabric, cut to length bent to shape as required and tying with and including anneded mild steel wire not less than 0.9 mm dia or fixing with galvanised steel stapple weight exceeding 4 kg per Sqm supplied and fixed to wood or steel member, complete all as specified and directed.
Rolled mild steel sections as in framing for cladding glazing and like, fixed with angle cleats and connecting plates etc conforming to completea all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Pre- painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
Pre- painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding ridges to wall, fixed with self tapping screws etc complete all as specified and directed
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Brick work with fly ash’ bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures instructions, complete all as specified and directed Note- WPC will be measured paid as supply only under respective items separetely.
Rendering 10mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick plaster in CM (1:3) on concrete surface of ceiling finished even & smooth without using extra cement complete all as specifiied and directed.
Preparing new or previously untreated surface of wall and applying three coats of white wash complete all as specified and directed.
Preparing new or previously untreated surface of ceiling and applying three coats of white wash complete all as specified and directed.
Preparing new or previously untreated surface of wall and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
Spreading and levelling under floor in layers n exc. 25 cm thick, well ramming including watering as required etc complete all as specified and directed. Note:- Earth obtained from excavation shall be used under this item of work
PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in coping, benching, cills, PCC gola, holdfast and the like including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as specified and directed.
Hard core of broken stone/boulder of gauge.exc 63mm but n exc100 mm deposited spread and levelled in layer n.exc 15cm thick watered and levelled in layer n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
100 mm thick PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in floor finished even and smooth using extra cement including spike rolling or making impression of expended metals while the concrete is green complete all as specified and directed.
Forming construction joint 30 mm deep x10 mm wide filled with sealing compound Grade 'A ' etc complete all as directed.
Mild steel screw bolts machine made with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed ends to be fitted with washers & one hexagonal or square nut 11 to 15mm dia meter of neck n.exc 5cm long complete all as specified and directed
75mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with sealing compound grade 'A' including necessary formwork etc complete all as specified and directed.
PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in surface channels and drains etc complete all as specified & directed.
Extra forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends complete all as specified and directed.
RCC 1:1.5:3 using using 20mm graded crushed stone aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves and the like complete all as specified and directed.
RCC 1:1.5:3 using 20mm graded crushed stone aggregate as in beams, cantilever bressummers lintel over 1.5 m span etc complete all as specified and directed
Use & waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick for fair finish surface complete all as specified and directed.
Use and waste of formwork to sides and soffits of floors or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports etc. and similar work of fair finished flat surface of concrete complete all as specified and directed
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
Sand filling under floors or in foundations including watering and consilidation complete all as specified and directed.
Cutting holes into or through brick wall built in cement mortar superficial area n. exc 150 Sq.cm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and directed.
75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches with MS clamp etc complete all as specified and directed.
PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm bore outlet complete all as directed.
PVC (SWR) bends any radius 75 mm bore complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick cement sand screed in CM (1:6) as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing complete all as specified and directed.
Mild steel works as in bands, straps, hold fast, angle cleats and similar small articles etc complete all as specified and directed.
15mm bore 2-way long body bib cock with wall flange chromium plated complete all as directed. Make:ESSCO (Jaquar) cat No. SQT-512AKN or equivalent of Make cera/Hindware
15mm bore stainless steel jet spray with 1.00meter PVC tube complete all as directed. Make: ESSCO (Jaquar) Cat No. ALE-547 or equivalent of make Cera/Hindware
40 mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in floor finished even and smooth using extra cement complete all as specified and directed.
40mm thick Damp proof course to horizontal and vertical surface including necessary form work in PCC 1:2:4 type B0 using 12.5 mm graded agg complete all specified and directed .
Machine pressed precast coloured concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade laid, jointed and pointed in grey cement with pigment to match the shade of tile with and including 25mm thick sand cushioing layer complete all specified and directed.
Supply only liquid water proofing compound complete all as specified & directed.
Glazed ceramic coloured tiles of size 300 mm x 200 mm x 7mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 10 mm thick rendering in cement mortar 1:4 finished rough surface to receive tiles complete all as directed.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete complete all as directed.
Rubberised chequered cement concrete coloured tiles 25 cm X 25cm X 20 mm thick, set, jointed & pointed in neat cement slurry in floor with grey cement & pigment to match the surface of tiles over & including 15 mm thick screed bed in CM 1:6 complete complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube & edges will be painted to match with printed sheets complete all as specified and directed.
Factory made solid panel PVC moulded door with wood free EPS shutter 28 to 30mm thick(style) with 2,4, or 6 raised panels designed with 2mm thick moulded PVC sheet on back face, supplied and fixed to frame at site as per specified and drawing with partical board core as per drawing in SSR Part II 2010 etc complete all as directed
Steel ventilators with top hung shutter including hinges, steel peg stay as per Drg No TD 032 Sh 1/10 to 10/10 complete all as specified and directed.
Butt hinges, 100mm long, medium weight, cold rolled, stainless steel complete all as directed
150mm long aluminium anodized handle cast complete all as directed.
200mm long aluminium anodized barrel tower bolt of extruded section complete all as directed.
250mm long aluminium anosized sliding door bolt with hasp staple (bolt type) and fixing clips to sheet cast or extruded section of cast aluminium complete all as directed.
3mm thick figured glass pin head type glass ordinary quality type & glazing with wooden beads in squares not exc 0.5 Sqm in each pan, complete all as directed.
15mm bore short body bib tap chromium plated with wall flange and aerator complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-511KN or equivalent of Cera/Hindware
500 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting complete all as specified and directed.
Ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms complete all as specified and directed.
Brass chromium plated towel rail 600mm long complete all as directed. Make : ESSCO (Jaquar) Cat No. AEC-1111 or equivalent of make Cera/Hindware
Overhead shower round shape 100mm dia round shape singlei flow (ABS body chrome plated with grey face plate) with with rubit cleaning system with including 115 mm long shower arm r complete all as directed. Make:-ESSCO (Jaquar) Cat No. EOS-542N or equivalent of make Cera/Hindware
15mm dia chromium plated concealed stop cock, heavy body with cap complete all as specified and directed. Make: ESSCO (Jaquar) cat No.SQT-514AKN or equivalent of Make cera/Hindware
20mm bore gun metal globe/gate valves, with iron wheel head, screwed both ends for iron/GI pipe complete all as directed. Make: Zoloto/Leader/Kirloskar/Upadhyay/Audco
20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete complete all as directed.
15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete complete all as directed.
Shelf of PTMT fixed with and including CP brass screws and wooden or plastic cleats complete all as specified and directed.
Aluminium hat pegs solid body, 125mm to 175mm fixed with screws complete all as specified and directed
Granite stone of any colour (of any type) 18mm to 20mm thick machine cut (table rubbed & polished), as in wall lining (veneering to wall) over 12mm thick cement mortar 1:3 and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite stone complete all as directed.
Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:3 for laying floor finishes complete all as directed.
50mm tube bore medium grade steel water tubing, galvanized (ISI Marked) including pully hook with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete complete all as directed.
2nd class hard wood plain fillets, sectional area 13sq cm & not exceeding 25 Sq cm, square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified & directed.
5 Ply 9mm thick plywood grade BWR BB fixed with screws to timber frame work as in wall panelling complete all as specified & directed.
3 Ply 4mm thick veneered decorative plywood grade 1(with BWR resin) with decorative face veeners on one face, fixes with nails to timber frame work complete all as specified & directed.
1st class soft wood plain fillet square rectanular exc 6 & n. exc 13 Sqcm fixed with nails complete all as specified & directed.
Chamfers, splays, grooves, rebates rounded angles rounded nosings tongued and grooved edges (each tongue and each groove measured) etc, exc 3mm but n. exc 75mm girth on softwood complete all as specified & directed.
Preparing surfaces of wood & wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote complete all as specified and directed.
Preparation of old wooden surfaces of any description, not other wise described over 10cm width or girth and apply one coats of varnishing complete all as directed
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including concealed non metallic rigid PVC conduit 25mm dia or higher with all fitting and fixing accessories and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6mm thick, 60mm deep of required size factory made for mounting switch, regulators etc with and including 3mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following:- Make of wire : Finolex, Havells, Polycab, Grandlay. Make of conduit : Finolex/Ess Ess Kay/ICL Note:- (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light/fan point /exhaust fan point controlled by one switch, one way switch 5/6 Amp
One3 pin/ 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
Switch piano, flush type, single pole one way, 5/6 Amp complete all as specified and directed. Make:- Anchor/Legrand/Havells/C&S.
Socket outlet multipurpose, 2 in 1 , 5 pin ,5/6 Amp flush type complete all as specified and directed. Make:- Anchor/Legrand/Havells/C&S.
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all as specified and directed. Make:- Anchor/Legrand/ Havells/C&S
Wall mounted LED batten fitting 22W LED 230 volts AC, cool white not less than 1200 x 108 x 62 mm extruded aluminium heat sink provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with and including 22W LED tube rod complete and connected the same with using PVC sheathed and insulated three core flexible23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls complete all as specified and directed. Make:- Havells cat part nos ENDURALINEARNEOBS22WLED830SPCHW or equivellent of /Philips/C&S.
25Watt LED cool white, energy saving IP66, environment friendly, long life, LED street light made up of pressure die-cast aluminium housing with high power LEDs as lighting source and lens embedded PC cover having top opening seperate driver compartment suitable for pole dia 43mm (max) including suitable size of bracket bent in shape including 2 Nos clamps, nut, bolts etc and fixing on walls etc complete all as specified and directed. Make:- Havells cat part No ENDURAPEARLSL25WLED 757 SASYTOPCMP or equivellent to Philips/C&S
Heavy duty exhaust fan 300 mm sweep with louvers single phase 240 volts, white in colours including necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and directed Make-,Havells model TERBO Force SP or equivellent Bajaj / Usha/CG
MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type and IP 43 degree protection complete all as specified and directed. Make:- Indo asian cat part no - 811807or equivellent of Legrand, L&T, ABB, Schneider
MCB isolator SP 240 Volts, 50 Hz capacity 6-32 Amp all as specified and directed.
MCB isolator SP 240 Volts, 50 Hz capacity 40 Amp all as specified and directed.
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 10 sqmm 2 core laid in trenches /duct /wall /floor etc complete all as specified and directed. Make: Finolex/Havells/Polycab/Gloster/plaza
Un-reinforced precast concrete cable cover class LV type1 flat size250 mmx 150 mm x40 mm as protection to under ground cable laid dry flat adjjoining each other complete all as specified and directed
Supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
GI pipe light grade ISI marked 40mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah with calmps, bolts, nuts & washers etc complete all as specified and directed. Make:- Tata/Jindal /Prakash
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
M/S RAJESH KUMAR GOYAL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .