Lt Col Bhamre Kiran S
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
PROVN OF GUARD POST, WEATHER SHELTER, ADDN/ALTN TO SHOPPING COMPLEX AND CERTAIN OTHER MAJOR REVENUE AND SPECIAL REPAIR WORKS AT AF STN SAMANA UNDER GE (AF) JAMNAGAR NO.1
2021_MES_431408_3
8793/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹78,000
Yes
19 Jul 2021
13 May 2021
28 May 2021
13 May 2021
27 May 2021
13 May 2021
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts wells cesspits manholes pier holes etc, nexc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified.
Returning filling in including spreading levelling watering & well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated material exceeding 250 m but not exceeding 500m & depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams and similar works for flat rough finished surface complete all as directed.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in foundation, footings, plinth Beam and similar RCC works all as specified and directed.
Use & waste form work to sides of pillars, posts and columns for rough finished surface square/rectangular of concrete complete all as directed.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts & similar RCC works all as specified and directed.
Use & waste of Form work to sides and soffits of floor or roof beams,lintiles cantilever etc for flat rough finished surface complete all as directed.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels & similar RCC works all as specified and directed.
Use & waste of Form work to soffits of suspended slabs such as roof slabs floor slab landing and similar work for flat rough finished surface complete all as directed.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like & similar RCC works all as specified and directed.
Use & waste of Form work to edges of suspended slabs n.exc 20 cm thickness for fair finished surface complete all as directed.
M & L for precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exe 10 cm thick, in width (with plain or inter locking joints as directed) set in CM 1:6 complete in wall or pillars all as specified and directed.
M&L for steel reinforcement of TMT bars (FE-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for steel reinforcement of TMT bars (FE-500 Grade) 6 to 8 mm dia cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for steel reinforcement of TMT bars (FE-500 Grade) not exc 8 mm dia as in stirrups cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surface of slab, beam & ceiling surfaces finished even and fair all as specified and directed.
M&L for rendering 10 mm thick on brick wall or concrete surface in cement mortar 1:4 finished even & fair all as specified and directed.
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and surface finished even and fair without using extra cement.
M&L for rendering 15 mm thick on other than fair faces of brick wall or concrete surface in cement mortar 1:6 finished even & fair all as specified and directed.
M&L for Preparation of old distempered / decorated surfaces of walls including washing, rubbing down and stopping holes, trading oil and greasy spots and applying two coats of Distemper oil emulsion complete as specified and directed.
M&L for preparation of old decorated surfaces of ceiling by booming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc. and applying one coat of white wash all as specified.
M&L for preparation of old decorated surfaces of walls including pilasters / cornices etc and applying one coat of Acrylic emulsion (exterior weather coat) paint of any tint as approved applied as per manufacturer's instruction complete.
M&L for preparation of wooden surfaces, exc 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by Engineer-In-Charge.
M&L for preparation of plastered surface of wall and applying two coats of Distemper oil emulsion over one coat of primer, after application of cement base wall clear putty all as specified & directed.
M & L for newely prepared steel surfaces and applying two coats of synthetic enamel paint over a coat of Red oxide of any description, over 10cm in width or girth, not otherwise described.
M&L for preparation of new plastered surface of walls including plaster / cornices etc and applying two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete.
M&L for preparation of new plastered surface of walls including plaster / cornices etc and applying two coats of oil bound distemper emulsion over one coat primer over and including one coat of cement base wall care putty applied as per manufacturer's instruction complete.
M&L for preparation of plastered surface of walls and applying two coats of Distemper oil emulsion over application of 3mm cement base wall clear putty all as specified & directed.
M&L for preparation of old plastered surface of walls and applying one coat of oil bound distemper all as specified and directed by engineer in charge.
M&L for preparation of old painted steel surfaces, exc 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed by Engineer-In-Charge.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed by Engineer-In-Charge.
M&L Cutting holes into or through in stone wall ex 150 sq. cm but n exc 400 sq. cmbuilt in cement mortar or cement lime mortar and walls of cement concrete in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required.
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m
M&L for glazed ceramic tiles coloured printed tiles 450X300X7mm thick set and jointed with neat cement slurry and pointed with coloured cement on vertical surface including 10mm thick backing coat in C M 1:4, complete all as specified & directed.
M&L for outdoor coloured vitrified paving tiles, joint free (edge cut) of size 300 mm x 300 mm x 8 to 10 mm thick as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete. Make - HR Johnson - Endura series or equivalent type of make mention in Appx 'B'
M&L for 600mmx600mmx10 mm thick vitrified Light shade ceramic tiles shade as approved flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
M&L for machine cut kota stone slab for shelf 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, moulding on edge and polishing over including cutting of wall as per directed by Engineer-in-Charge.
M &L for 18 to 20 mm thick machine cut & machine polished Kota stone slab as in flooring laid over and including 20 mm thick cement screed base in CM 1:6, laid, jointed & pointed with grey cement slurry including rubbing and mirror polishing complete
M&L for joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square / rectangular) polished area of each tile exc 0.11 Sqm but n. exc 0.18 sqm as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colure) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed.
(a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370).
Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B. (ii) Floor door spring & lock will be measured & paid separately.
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead jointing cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, including taking down old steel window complete all as specified and directed.
(a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20832) (c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55mm (Section No 20738) ... ...(d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45mm (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55mm (Section No 20736) Note:-Section No given above are of make Jindal.
S&F aluminium powder coated minimum thickness of power coated 50 micron of approved colour ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including supply and fixing S.S wire gauge of 0.36mm dia and 1.40 width of aperture with 25x3mm think aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position including taking down old steel ventilator complete. Note:- (i) Section No given above are of make Jindal.
S&F Double action floor door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position. Make:- Godraj / Sandhu / Everest
S&F 15 mm bore GI tubing medium grade including all fittings & fixture fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm bore GI tubing medium grade including all fittings & fixture fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply and fix / laid in trenches 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line complete all as specified and as directed by Engineer-in-Charge.
Supply and fix / laid in trenches 40 mm bore galvanised steel water tubing, light grade including necessary fittings such as GI bends / elbow, tee, union etc complete and connecting to water supply pipe line complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 25 mm size gun metal gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed complete.
S&F CI nahani trap plain with S/S grating including jointing with solvent cement dia of outlet 75mm ISI Marked.
M&L for 150x100mm Salt-glazed stoneware gully traps, square or round mouthed, type 'P' complete as all specified and directed by Engg-in-Charge.
S&F 75 mm dia Cast iron sand cast iron pipe, for soil, waste and vent in any length , laid in trenches, with cement joints, complete.
S&F 100 mm dia Cast iron sand cast iron pipe, for soil, waste and vent in any length ,with or without ears, laid in trenches, with cement joints, complete.
S&F 75 mm dia bore CI oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete.
S&F 100 mm dia bore CI oval access door bend (any radius) diminishing pieces or tapers (Larger bore measured) complete.
Supply and fix 100 mm cast iron Cowls complete all as specified and directed by Engg-in-Charge.
Supply and fix 100 mm dia Sand cast Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete.
M&L for providing 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars.
M& L for providing 600mm dia reinforced concrete pipes class NP2 laid and jointed completed with collars complete all as specified and as directed by Engr In Charge
M&L for Concrete bed to drain pipes type C2 1:4:8 bore of pipe 150 mm including packing under, and haunching against the sides of pipes after they are laid and tested
S&F for 500 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and providing 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) and dismantling of water tank etc.
S&F 20 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing.
S&F Factory Made Solid PVC Moulded Door Shutter with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face, fixing to frame with 100 mm stainless steel hinges at site as per specification & drawing.
M&L for 150mm long aluminium handles fabricated type anodised all as specified.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to complete all as specified and directed by Engg-in-Charge.
M&L for 150 mm aluminium anodised barrel tower bolts of extruded section and fixed.
Supply and fix cast iron P trap 100 mm complete all as specified.
M&L for providing Wash down water closet pan (Pedestal pattern) fixing to floor complete all as specified.
S&F Angular stop cock cast copper alloy fancy type chromium plated fixed to pipe complete all as specified.
S&F in repair shower arm casted 190 mm long light body round shape for wall mounted showers with flange including fixing complete all as specified.
S&F in repair overhead shower 100 mmm round shape multi flow (ABS body chrome plated with gray face plate)with Rubit cleaning system.
S&F in repair brass chromium plated wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs & wall flanges fixed in position complete. Make:- Jaquar-FUS-29273UPR or equivalent of make mentioned in Appendix 'B
S&F in repair 15 mm size cancelled type stop cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete.
S&F PVC connections 15mm size with PTMT nuts of length 450mm.
S&F PVC valveless 10 ltr capacity, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets.
S&F for chromium plated two way bib cock 15 mm, cast copper alloy with screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F bib cock 15 mm and Bib taps 15 mm, cast copper alloy with screwed down, screwed for iron pipe or for brass ferrule and fixed.
Supply and fix wash basin white size 190x575x470 including half pedestal fixing to wall and connection to waste pipe complete all as specified.
S&F 15 mm Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F Soap dish holder fixed to wall complete all as specified.
Supply and fix single towel rail 600 mm long fixed to wall complete all as specified.
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 450 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 400 x 550 x 200 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, 750 mm long PVC waste pipe, PVC connection pipe, 15 mm size and 450 mm long with PTMT nuts and washer at both end etc. complete.
S&F in repair Stainless Steel Grating square 150 mm x 150mm size with waste hole complete.
Supply and fix 32 mm dia waste coupling with full threading 80 mm height fixed to wash basin and waste pipe complete all as specified. Make :Jaquar ALD- 705
S&F 32 mm dia LDPE pipe of pressure rating 6 kgf/cm2 fixed complete to wall ,ceiling or floors including all fittings complete.
S&F white vitreous china urinal full stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securinfal to plugs with and including 60 mm long brass screws pointing around urinal back in white cement complete.
S&F urinal spreader of brass chromium plated suitable for 15mm dia pipe complete.
Excavation in post holes in soft / loose soil (or similar holes) each n.exc 0.5 cum, getting out, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil removing surplus soil to a distance n exc 50 m complete all as specified and directed.
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and as directed.
Supply only Liquid water proofing compound.
Hardcore of broken stone or boulder gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick watered and rammed to true surface.
M&L for providing 25 mm thick cement concrete type B1 1:2:4 using 20 mm graded aggregate complete all as specified and directed.
M&L light shade double charged colour vitrified ceramic tiles 10mm thick (square/rectangular ) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
All as above but laying of tiles as in dado / skirting over and including backing coat 10 mm thick in cement mortar 1:4
M & L for 75 mm thick plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate as in plinth protection surfaces finished even and smooth without using extra cement including filling the joints by bitumen and sand mixed in the ratio 1:1 by weight complete all as directed.
M&L for Granite stone slab 16 to 18 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade, laid over and including 15 mm thick cement screed bed in CM 1:6 complete.
M&L for 18 to 20 mm thick pre polished Green marble slab, machine cut bedded, jointed with neat cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match as in window cill, risers / Treads of steps over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
S&F in repair 1.25 mm thick steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type complete all as specified & directed.
S&F in repair mild steel framed work as in door chowkhats , shutters of angles or other section with gusset plates, rails, braces etc complete drilling welding for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hooks and hinges for steel door fittings (exclusive of steel sheeting or other covering running rails or guides) and hanging also fastening and fixing (Fe-290-Gde-165) complete all as specified & directed.
S&F 35 mm thick second class hardwood factory made Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass / gauge, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fitted to chowkats complete.
S&F 35 mm thick factory made second class hard wood (rail & style) factory made plain framed panelled shutter two nos of panels with lock rail and panels of 12 mm thick veneered particle board with commercial veneering on both faces the size of rail and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified & directed.
S&F 35 mm thick Plain, framed, panelled shutters (any number of panels),second class hardwood kiln seasoned and chemically pressure treated with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F for 200 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed.
Surface excavation n.exc (not exceeding) in soft loose soil 30cm deep and averaging 15 deep and getting out.
Removing excavated soil to distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L Moorum filling in pavings of road, laid in layers n.exc. 15cm thick spread, levelled and rammed including watering.
M&L for 75 mm thick plain cement concrete 1:4:8 type B2, using 40 mm graded stone aggregate, as in sub base to floors and paving etc all complete all as directed.
M&L for 100 mm thick plain cement concrete 1:4:8 type B2, using 40 mm graded stone aggregate, as in sub base to floors and paving etc all complete all as directed.
M&L for 150 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring / path / hard standing etc. all specified and directed.
Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, top layer with white cement and pigment laid over and including 25 mm thick (compacted thickness) sand screed bed complete all as specified and as directed by Engg-in-Charge.
M&L for 100 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base / path / flooring complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4, type B2 using 40 mm graded stone aggregate as in as in floor / path / hard standing, and similar works, finish the surface fair & even all as specified and directed.
M&L for PCC1:3:6 type C-2 (40mm graded aggregate) as in walls etc all as specified.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation fillings and mass concrete complete
M&L for cement concrete 1:2:4 type B 0 using 20mm graded stone aggregate as in foundation filling and mass concrete complete
Demolition of plain cement concrete in ground floor and pavings of any description exc 15 cm thickness below or above ground level, complete. All as specified and as directed by Engineer-in-Charge.
Demolition of brick / stone / PCC block masonry/cemented jaali built in cement mortar including all quoins, pillars, arches etc. including removal of debries to a distance exc 1.5 km but n.exc 2 Km, all as specified and as directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area n.exc 1.5 Sqm each, complete all as specified and directed
Taking down Shutters of any description exc 1 sq.m but not exc 2 sqm each.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 km but n.exc 2 Km, all as specified and as directed.
S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections of GDE Fe410-0 or Fe 310-O all as directed by Engr-in-charge
Removing and shifting including refixing of wooden cupboard of size n exc4 Sqm with complete fixing at a distance n exc 50 m as per specified by Engr- in - Charge.
Removing and refixing of glass door of size n exc 4 sqm at other place including floor spring distance n exc 50 m all as specified by Engr-in-Charge.
S&F in repair stainless steel sink 1.00 mm thick (SS grade 304 AISI 18/8) IS embossed (IS:13983) for kitchen or laboratory, with plug, washers, waste pipe including bedding in cement mortar on to draft wall or including fixing cantilever brackets, connecting union to pipe etc, overall size 915 mm x 460 mm, with bowl size 410 mm x 330 mm x 160 mm with including waste coupling, waste pipe complete all as specified and directed.
S&F Mortice lock vertical type of mild steel 4 levers of size 100 mm all as specified. Make : Godrej, ozone or equivalent.
S & F sliding glass of 5 mm including frame and lock for shelf as per direction of Engr- in-Charge.
S&F false ceiling of 10 mm thick of cemented board of size 600 mm x 600 mm fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium frame work will be supported on side wall with the use of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long, including two coats of synthetic enamel paint over a coat of pink primer complete all as specified directed by the Engineer-in-Charge.
M&L for providing and PVC Vinial flooring for Badminton court of 4.50 mm thick. Each roll of size 1.80 mtr x 15.00 mtrs litchi patterns with green colour court with white colour marking all as specified and all as directed by Engr In Charge
M&L for Steel work in tubular trusses fabricated with rectangular including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-310
S&F Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M & L for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including super deluxe casing capping (not less than 25 mm wide) with all its accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire and plastic laminated white top sheet cover 3.0 mm thick for:
a) One 3 pin socket out let 5 Amps on the independent board.
b) One light point/Fan/exhaust fan point controlled by one way switch
All as per item No 140 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC concealed conduit wiring not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover complete.
All as per item no.142 above for 5 Amps socket outlet on same board
All as per item no.142 above for 5 Amps socket outlet on independent board
All as per item No.142 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including Steel conduit not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S & F Switch socket combination out let 2 in 1 multipurpose 5 pin 5 Amps, flush type, 230 / 250 Volts complete. Make -Leader/Anchor/SSK
S & F switch socket outlet combination out let 2 in 1 white poly carbonate body combination ,6A/16A-230 Volts, multipurpose including connecting complete all as specified and directed.
M&L Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M&L for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting complete.
Supply and fix LED aviation light for helipad of specification wattage 50 watt ,230 V, 50 HZ of white color, IP rating 66 all as directed by Engr-in-charge Make:- Lokozo part no AVX-AX-50
Supply and fix NVG compatible Portable helipad light of wattage 10 , works on 12 V dc having battery including battery cahrger adapter. Part No NVG 305A/IAF-AFLS-NVG-CPHL:-00012
Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, including taking down old cable complete.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. (Note: for measurement purpose any punned thickness of sand will be considered.)
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed by Engr-in-Charge.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 6 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s single pole & neutral, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 amps.
Supply and fix stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete.
S&F high intensity ,long range,weather & dust proof security light with highly polished stainless steel reflector-cum body, suitable heat sinks, toughened front glass, retaining ring, MS cradle and passaiveted bolts. The search light would be supplied with 230 V 150 Watt LED COB lamp and its electronic driver in cast aluminium housing . The search light fitting woulkd be suitable for installing on the roof the watch tower cabin with arrangement for both vertical and horozontal operational control from inside the cabin. Make:- SIGMA Type 24441- CCA
S & F in repair LED Flood Light fitting 250 watt, High Efficiency IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on bracket of any description complete all as directed by Eng-in-charge. Make :- Crompton/Wipro/C&S Cat part No.:- Crompton LHB-250-CDL/60, C&S LTLHB250WLED
Supply and fix Energy efficient recessed mounted LED 36 watt luminaries suitable for 600 mm x 600 mm grid ceiling along with flat diffuser along with constant current electronic driver all as specified and directed by Engg-in-charge . Make:- Philips/havells/Crompton or equivalent Cart Part No.:- Crompton LPCL-36-CDL(2x2)
M&L for shifting of split Ac along with its outdoor unit including with its connecting pipe .
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated Make:- Crompton/Havells/V guard Cat Part No:- Havells GHWEBETWB025 & cromtpon ASWH1025
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Supply and fix ceiling fan five star rated of 1200 mm sweep compete with blades, down rod conopy electronic type regulator etc including hanging in position and connecting with 3 core, 0.50 Sqmm copper conductor PVC insulated and PVC sheathed round cable from ceiling rose to fan complete all as specified and directed by Engg -in-Charge. Make Havells cat No. ES -50 or equivalent of Make Bajaj, Crompton, Usha
Supply and fix Ventilating fan 300 mm sweep AC, 240 volts, metal body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete. Make Havells or equivalent of Make mention Appendix B.
Supply & fix ceiling mounted cabin fan complete of specificatoion 300 mm sweep ,230 V,50 Hz, button control , adjustable wind direction, protective grill and three speed control regulator along with connection wire complete. Make Havells/Bajaj or equivalent of Make mention in Appx B
M&L for cutting existing pipe line and inserting tee of equal size 25x25 for making arrangement of extension of pipe line.
sanu enterprise
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .