| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bid | |
| 2 | L2₹17.1 L+₹31,444.60 (1.87%)Rejected-Finance | L2 | Rejected-Finance Bing Higher Bid | |
| 3 | L3₹17.4 L+₹56,312.60 (3.35%)Rejected-Finance | L3 | Rejected-Finance Bing Higher Bid | |
| 4 | L4₹18.9 L+₹2.1 L (12.3%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L4 | Rejected-Finance Bing Higher Bid | |
| 5 | L5₹21.5 L+₹4.7 L (28.1%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L5 | Rejected-Finance Bing Higher Bid |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
11 Mar 2021, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REPAIR / REPLACEMENT OF INTERNAL WIRING AND REPAIR OF SOLAR WATER HEATER AND CONNECTED WORKS AT 7 A AREA (OTM AND MD ACCN) AT MIL STN PITHORAGARH
2021_MES_421924_1
8361/PGH/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Pithoragarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹47,000
Yes
5 Apr 2021
13 Feb 2021
13 Mar 2021
13 Feb 2021
11 Mar 2021
27 Feb 2021
13 Feb 2021 - 27 Feb 2021
Amount
DESCRIPTION OF ITEMS
Taking down old point wiring (Light fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc) removing materials from site and making good disturbed surface of walls, floors etc, complete all as specified and directed.
M & L for point wiring Surface type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non metallic PVC surface conduit 20mm or higher dia, heavy grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly, screwed with screws, cup washers complete all as specified and directed for the following :-
(a) One light point/ fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps.
(b)one socket outlet three pin 5 amps control by one switch on the same board
(c)one socket outlet three pin 5 amps control by one switch on independent board
(d) One light point controlled by two, two way switch of 5/6 amps
All as per Item No 2.00 above but with 2.5 Sqmm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete all as specified and directed.
M & L for point wiring concealed type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non-metallic exhusting PVC concealed conduit 20 mm or higher dia, heavy grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly ,screwed, cup washers complete all as specified and directed for the following :-
(a) One light point/ fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps.
(b)one socket outlet three pin 5 amps control by one switch on the same board
(c)one socket outlet three pin 5 amps control by one switch on independent board
(d) One light point controlled by two, two way switch of 5/6 amps
All as per Item No 4.00 above but with 2.5 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete.
Supply and Fix Switch piano, flush type, white finish, 5/6 amps, single pole, one way complete all as specified and directed.
Supply and Fix Socket outlet 5 pin, 5/6 amps and flush type, non shutters, non inter locking type, complete all as specified and directed.
Supply and Fix Switch piano, flush type, white finish, 5/6 amps, single pole, two way complete all as specified and directed.
Supply and Fix Switch piano flush type, white finish, 15/16 amps, single pole, one way, complete all as specified and directed.
Supply and Fix Socket outlet 2 in 1, 5/6 pin, 5 and 15 amp flush type, complete all as specified and directed.
Supply and Fix in repair of bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed.
Supply and Fix in repair of bell electric Ding Dong type, AC, SP 240 volts, complete as all specified and directed.
Supply and Fix in repair Switch piano, flush type, white finish, 5/6 amps, 230 volt grade single pole, one way complete all as specified and directed.
Supply and Fix in repair Switch piano flush type, white finish, 15/16 amps, single pole, 230 volt grade single pole, one way complete all as specified and directed.
Supply and Fix in repair Socket outlet 5 pin, 5/6 amps flush type, non shutters, non inter locking type, complete all as specified and directed.
Supply and Fix in repair Socket outlet two in one 2 pin 5/6 amps and 3 pin 15/16 amps (multipurpose), flush type, non shutters, non inter locking type, complete all as specified and directed.
Supply and Fix in repair of bell electric multi music type, AC, SP 240 volts, sound as approved complete as all specified and directed.
S&F in repair Electronic fan regulator flush type, 300 W Step type, 230 volts ISI marked. icomplete all as specified and directed.
Supply and Fix ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.
Supply and Fix in repair lamp holder, insulated body with back plate suitable for batten /angular fittings and making connection etc complete all as specified and directed.
S& F in replacement Electronic Balast 36/40 Watt, complete all as specified and directed.
Supply only tape roll insulation (25 mtr long) suitable for 1.1 KV grade best quality, good adhesive as sample held with AGE office complete all as directed.
S& F in replacement Florecent tube rod 36/40 Watt,complete all as specified and directed.
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with including one single pole MCB of 20amp all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure TPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure , SPN, 8 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure for DB, SPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and
Supply and Fix in repair MCB single pole, 240 volts, 6-32 Amps of 10 KA ‘C’ series 240 Volts complete all as specified and directed.
Supply and Fix in repair MCB single pole & Neutral ‘C’ series 240 Volts, 6-32 amps, of 10 KA complete all as specified and directed.
Supply and Fix in repair MCB Triple pole & Neutral ‘C’ series 240 Volts, 63 amps, of 10 KA
Supply and Fix in repair MCB Triple pole & Neutral ‘C’ series 240 Volts, 100 amps, of 10 KA
S & F in repair plug top 15A, 240 volts
S & F in repair plug top 5A, 240 volts
Supply, instalation and teasting in replacement of electric temper proof energy meter ,ISI marked, single PH 230V 2 wire 10-60 Amp with optical poat facility including sealing wire and sealing bits , Accuaracy-class complete all as specified and directed. (Note: Old unsv meter shall be deposited by contractor in MES store yard.)
Supply and fix in replacement of LED Integrated Batten with Polycarbonate housing, surface mounted, (1x9 Watt) prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
Repair of exhaust fan AC single phase 230/240V of size 250/300 mm sweep with rewinding super enameled copper winding wire of suitable size and proving with suitable insulation including repalcement of wornout nut bolt washer blade split pin etc reassembling and testing on completion complete all as specified and directed
Repair of exhaust fan AC single phase 230/240V of size 400/450 mm sweep with rewinding super enameled copper winding wire of suitable size and proving with suitable insulation including repalcement of wornout nut bolt washer blade split pin etc reassembling and testing on completion complete all as specified and directed
Material & Labour for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn in existing PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed. Note: Three runs of 4 Sqmm shall be measured as one unit.
Material & Labour for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x6 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn in existing PVC conduit along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed. Note: Three runs of 6 Sqmm shall be measured as one unit.
Supply and Fix in repair of 1x20 watt LED security light fitting, pressure die-cast aluminium including fixing the same of GI pipe 25mm dia bore light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x 4mm duly painted and suitable size of nut & bolts etc. and making electric connection with two core copper flexible wire of 0.50 Sqmm complete and including taking down old fitting all as specified and directed.
S & F in repair recess mounting LED 2x2 luminaire 34W, slim ceiling light with extruded aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed.
S & F in repair LED bulk head 10 Watt with PDC aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed.
Supply and Fix in replacement of LED Linner & compact 9W mirror lightwith decorative grey end caps, polycarbonate body and ribbed opal diffuser, 9W 6000K complete all as specified and directed.
M & L for earthing in replacement complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 5 of MES schedule 1991 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed.
Supply and fix in repair of LED Integrated Batten T5 box type surface mouted, (1x18 Watt) prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
Supply & fixing in repair of 1100 volts grade heavy duty cable with PVC insulated aluminiuum conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core 10sq mm solid conductor.
Supply and laying in repair XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 3.5 core x 35 Sqmm including laying, testing and commissioning complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engr-in-Charge.
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engr-in-Charge.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection incliding levellling and consodilation complete all as specified and directed by EIC.
M&L for laying well burnt bricks,as in protection of cable laid dry, flat aboutting each other wide wise all as directed by Engineer-in-Charge.
S & F in replacement GI tubing 40 mm dia light grade for cable protection all as specified and directed
Checking of fault in Solar water Heater of area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items like screw, insulation Taps, flexible twin core cable upto 1 mtr approx or any electrical accessories of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified and directed by Engineer-in-Charge. Notes: (a) Replacement of solar heater items, if required shall be measured and paid separetely in relevant items. Unserviceable items retrived form complaints shall be abstracted under sch of credit. (b) The fault shall be attended within one day, otherwise recovery shall be charged Rs. 50/- per complaint per day. (c) Electrician and plumber shall obtain the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments. (d) Descaling chemical shall be measured and paid separately.
Supply only Heating element 2 KW
Supply only Heating element 3 KW
Supply only Thermostat
Supply only EIS-DA (descaling chemical for all type metal)
Supply only Temperature guage
Supply only Toughened Glass
Supply only Makeup tank of Stainless steel as per sample
Supply only NRV of makeup tank
Supply only Elbow 15mm
Supply only Elbow 20mm
Supply only Elbow 25mm
Supply only Tee 15mm
Supply only Tee 20mm
Supply only Tee 25mm
Supply only Socket 15 mm
Supply only Socket 20 mm
Supply only Socket 25 mm
Supply only Union 15mm
Supply only Union 20mm
Supply only Union 25mm
Supply only Reducer elbow 20mm
Supply only Reducer elbow 25mm
Supply only Reducer Tee 20mm
Supply only Reducer Tee 25mm
Supply only Reducer Socket 20 mm
Supply only Reducer Socket 25 mm
Supply only Hex nipple 15 mm
Supply only Hex nipple 20 mm
Supply only Hex nipple 25 mm
Supply only Tank nipple 15 mm
Supply only Tank nipple 20 mm
Supply only Tank nipple 25 mm
Supply only Plug 15mm
Supply only Plug 20mm
Supply only Plug 25mm
Supply only Nipple 15 mm
Supply only Nipple 20 mm
Supply only Nipple 25 mm
Supply only Ball valve 15mm
Supply only Ball valve 20mm
Supply only Ball valve 25mm
Supply only GI pipe medium grade 15 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 20 mm, ISI marked all as speficied and directed
Supply onlyGI pipe medium grade 25 mm, ISI marked all as speficied and directed
Supply only clamps as per sample
Supply only flexible hose pipe 20 mm as per sample
Supply only gasket as per sample
Supply only of M-Seal
Supply only float valve 20 mm
Supply only float valve 25 mm
M & L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on complete copper tubing in solar water heater and after completion of job reassembling the same complete all as specified and directed
M & L for painting of solar water heater of old MS stand with mokey case of tank duly painted of one coat of Black enemaled paint complete all as specified and directed.
Disconnecting existing over head water storage tanks capacity n exc 200 Ltrs for cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes, etc and reconnecting and including one coat synthetic enamel paint on tank of size 450mmx300mm and writing letters ("CLD ON MM-YY") of height 7.5cm complete all as specified and as directed. Note : Cleaning of tank should be done carefully by means no float valve broken or no leakage remains after cleaning.
S & F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge
S & F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs all as specified and directed by Engr-in-Charge
Taking down sub main wire including with earth wire of any size, fixed in any position, complete all as specified and directed.
Shri Siddhi Vinayak Constructions
URBANS CONSTRUCTIONS
SHAHJEE FRIDGE SERVICE
M/s J P Traders
AJA BUILDERS
m/s vishnu kumar agarwal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .