Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC 245 2 RAJPUR ROAD OPPOSITE HOTEL MADHUBAN DEHRADUN | ₹1.3 Cr | 1 | Accepted-AOC lowest bid rates |
| 2 | 2₹1.3 Cr+₹40,910 (0.31%)Rejected-Finance | ₹1.3 Cr+₹40,910 (0.31%) | 2 | Rejected-Finance higher bid rates |
| 3 | 3₹1.3 Cr+₹1.3 L (0.99%)Rejected-Finance A 3 332 SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹1.3 Cr+₹1.3 L (0.99%) | 3 | Rejected-Finance higher bid rates |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
4 Mar 2024, 1:30 pmClosed
Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),Dehradun
Laying spare HT/LT cable and replacement of damage HT/LT line cable for minimizing downtime during any kind of fault at Mall Road, Mussoorie and associated work.
2024_UPCL4_69686_1
Tender No. 23/EDC(U)/2023-24
Open Tender
Electrical Works
Item Wise
120 days
as per tender specification
as per tender specification
4 documents required · 4 mandatory
₹11,800
Superintending Engineer, EDC (Urban),Dehradun
₹2.6 L
16 Mar 2024
16 Feb 2024
4 Mar 2024
17 Feb 2024
4 Mar 2024
19 Feb 2024
Material
11kV 3CX150 sqmm XLPE Armoured Cable
HT Termination Kits - Outdoor - 3C X 150 sqmm
11kV 3CX120 sqmm XLPE Armoured Cable
HT Termination Kits - Indoor - 3C X 120 sqmm
11 kv 3X300 Straight through cable jointing kit
LT XLPE Alu.Armoud Cable 3.5.x 400 sq. mm.
LT XLPE Alu.Armoud Cable 3.5.x 240 sq. mm.
LT XLPE Alu.Armoud Cable 3.5.x 120 sq. mm.
LT XLPE Alu.Armoud Cable 3.5.x 95 sq. mm.
LT XLPE Alu.Armoud Cable 2x10 sq. mm.
LT XLPE Alu.Armoud Cable 4x 16 sq. mm.
LT XLPE Alu.Armoud Cable 4x25 sq. mm.
65 mm HDPE Conduit Pipes ( PE-80, PN-6.0)
160 mm HDPE Conduit Pipes ( PE-80, PN-6.0)
90 mm HDPE Conduit Pipes ( PE-80, PN-6.0)
400Sq. MM LT Al Lugs
240Sq. MM LT Al Lugs
120Sq. MM LT Al Lugs
95Sq. MM LT Al Lugs
45 MM double compression Al LT Glands for 120/95 Sq MM Cable
63 MM double compression Al LT Glands for 400Sq MM Cable
57MM double compression Al LT Glands for 240/120 HtSq MM Cable
45 MM double compression Al LT Glands for 120/95 Sq MM Cable
3.5x240 sqmm LT Straightthrough Kit
Ashida Make OC/EF Relay ( ADR 141c)
LT MCCB 250 A
Zipper Sleeve 400 SQmm
Zipper Sleeve 240 SQmm
Errection
Carriage of Centralize Material
Erection & Laying of HDPE Pipe 160/90/65
Erection and laying of 11 XLPE Alu.Armoud Cable along with Existing HDPE Pipe
Erection and laying of LT XLPE Alu.Armoud Cable 3.5.x 240 sq. mm. along With HDPE Pipe
Erection and laying of LT XLPE Alu.Armoud Cable 3.5.x 400 sq. mm. along With HDPE Pipe
Erection and laying of LT XLPE Alu.Armoud Cable 3.5.x 120 sq. mm. along with HDPE Pipe
Erection and laying of LT XLPE Alu.Armoud Cable 3.5.x 95 sq. mm. along with HDPE Pipe
Erection and laying of LT XLPE Alu.Armoud Cable 2x10 sq.
Erection and laying of LT XLPE Alu.Armoud Cable 4x16 sq. mm.
Erection and laying of LT XLPE Alu.Armoud Cable 4x 25 sq. mm.
Erection & Installation of Cable jointing kit for 11kV XLPE Cable
Testing of faulty HT/LT cable with help of fault finding equipments and ecomplete repairing of cable with using termination kit
Overhauling of VCB / onload changeover of CSS & RMU
Overhauling and maintenance alignment mechanism of 11 KV CB ( SF6) for smooth operation including replacement of all rusted / deform N & B , removing old lubrication , cleaning of all moving Parts & Fresh H.Q Lubrication
Overhauling and maintenance alignment mechanism of 11 KV Onload Isoletor for smooth operation including replacement of all rusted / deform N & B , removing old lubrication , cleaning of all moving Parts & Fresh H.Q Lubrication
Maintenance of operation of 11 KV CB Mechanism ie Tripping spring and closing spring Charging assembly / Auxilary switch assembly with replcement of required parts
Cleaning of Transformer Chamber Ushing Vacumme Cleaner , replacaemnt of Door Packing if required , caliberation of temperature meter , oil level indicator and other proximity sensor, Tightning of All FAstners
Annual Maintenance start after one year of above work ( 03 Month Peridocaly) of 33/11 KV VCB/SF 6 as SOP Prescribed by Manufacturer by Skilled Technician ( Material if need to replced during Maintenance provided by UCPL)
Annual Maintenance of LT Feeder Pannel & Bus Bars (MCCB, ACB,MCB) on quaterly basis ie Tightning of N&B of Pannel & Bus Bars (ACB/MCB/MCCB ) Cleaning of Pannel inner and Outer replacement of damage parts( Material if need to replced during Maintenance provided by UCPL) all work maintaned in Sheduled PM Chart
Testing of 11 KV SF6 breaker with autorised person
Supply and Fixing of Cirucit identification tag on CSS/Feeder Piller /Bus Bar Pannel
Painting of MS Frame / Ladder/Stair/ Railing of Existing CSS and RMU Structure
Disconnection of All connection and Dismentaling of RMU/3 way/4 way/5 way
Removing of RMU from Existing location and shifted to another location with help of crane etc and fixing of RMU in new loaction
Making of All connection of RMU at new Loaction
Making of Connection of LT Cable at CSS/LT Pannel end
Making of Connection of 11 KV Cable at CSS/RMU Pannel end
Earthing of CSS /RMU/Pannel including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor as per drawing No. A) as drawing B, connecting the same with G.I. Strip (to be supplied by contractor ) of size 35x6 mm as per drawing C for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than .2 Ohm.
GI Plate earthing of Power T/F at Substation as per annexure A ( two for Body and two for NeutralWIth GI Plate 1200x1200x60 MM and other required matreial
Excavation of pit for earthing on mix soil / Hard Rock having size depth of 15 feet as per drection of UPCL as per site requirement making and jointing of Cu Strip complete work .
Fixing earth plate vertically at bottom of the Pit & making alternate layer of Charcoal & marconite/Bentonite & salt .
Back filling of pit with farming soil /Fresh Soil including cost of soil and loading unloading.
Disposing of Excavated soil at outer area from Municipality musoriee.
Connecting of Cu Plate earthing with T/F, Pannel with welding /Bolting Etc.
Work of Fixing Jall at top of the structure on CC 1:4:8 after maintaining earthing cover of the ground.
Erection & Installation of 400Sq. MM LT Al Lugs
Erection & Installation of 240Sq. MM LT Al Lugs
Erection & Installation of 120Sq. MM LT Al Lugs
Erection & Installation of 95Sq. MM LT Al Lugs
Erection & Installation of 63 Sq. MM LT Glands
Erection & Installation of 57 Sq. MM LT Glands
Erection & Installation of 45 Sq. MM LT Glands
Errection of Straight Through Joint LT Outdoor Type 3.5 x 240 sq mm
Replacement of Damage LT MCCB
Fiiling of 11 KV termination kit
Dismnetaling of existing damage LT /HT Cable
Overhead HT/LT Line Protection
Supply of Outdoor type totaly enclosed weather proof (IP54) feeder Piller having 400Amps MCCB as incomer as per specifications Type-A as per annexure A
Supply of Outdoor type totaly enclosed weather proof (IP54) feeder Piller having 250 Amps MCCB as incomer as per specifications Type-A as per annexure A
Supply of 200 Amps Aluminium Bus Bar Box dust,moisture & vermin Proof ( IP54) made out of 14/16 SWG CRCA Sheet powder coated with top & botttom removable gland plates.
Insulation Testing of Existing laying HT/LT Cable for with Required T&P
Civil Work
Sub Head I: Earthwork
Earth work in excavation by mechnical means / manual means over areas ( For trench for laying of HT/LT Cable and other work) ,including disposed earth to be levelled and neatly dressed (in all kind of soils / CC road )
Back Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers , consolidating each deposited layer by ramming and watering .
Sub Head III: RCC / PCC Work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All works upto plinth level (i) 1:4:8 (1 - Cement; 4 - Coarse sand; 8 - graded stone aggregate 40mm nominal size).( Foundation, footings, bases of columns, etc for mass concrete)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level (i) 1:1.5:3 (1-Cement; 1.5 - Coarse sand; 3 - graded stone aggregate 20 mm nominal zise). ( For Road Repairing / Other work/Chamber Work)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All works upto plinth level (i) 1:2:4 (1-Cement; 2 - Coarse sand; 4 - graded stone aggregate 20 mm nominal zise). ( Chamber Work)
Sub Head Iv: Brick Work and plastering
Brick work with common burnt clap bricks with cemnt mortar 1:4
Plastering work on Column / Brick Wall / beam in R C ratio 1:4 thickness 1.5 cm
Providing and Fixing of Ceramic Glazed wall tiles fo approved make over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement
Sub Head IV: Steel Works
Providing and fixing hand rail of approved size by welding etc. to steel . For Cable tray /door/etc
Providing and fixing MS Channel/Rail Joist for RMU Structure / Other Base of approved size by welding etc. to steel .
Dispoal of Sand from site to location given by local authority prox 20 km distance including proper Loading and Unloding same
Composite Engineers
Creative Entrepreneurs LLP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .