| 1 | L1₹6.1 CrAccepted-AOC HOUSE NO 2 BYELANE ANJALI UPA PATH AJANTA PATH SURVEY P O BELTOLA GUWAHATI 781028 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781028 | ₹6.1 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹6.9 Cr+₹71.7 L (11.7%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | ₹6.9 Cr+₹71.7 L (11.7%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹7.3 Cr+₹1.1 Cr (18.5%)Rejected-Finance | ₹7.3 Cr+₹1.1 Cr (18.5%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹7.7 Cr+₹1.5 Cr (24.6%)Rejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹7.7 Cr+₹1.5 Cr (24.6%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹8.4 Cr+₹2.2 Cr (36.2%)Rejected-Finance GOKUL APARTMENTS BLOCK C SHIVMANDIR ROAD PUNJABI PARA SILIGURI 734 401 WEST BENGAL | SILIGURI | WEST BENGAL | 734401 | ₹8.4 Cr+₹2.2 Cr (36.2%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹6.4 Cr
EMD Value
₹6.5 L
Closing Date
30 Mar 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF DEFICIENT MARRIED ACCN FOR OFFICERS WITH ASSOCIATED INFRASTRUCTURE AT AIR FORCE STATION TEZPUR (PH-1)
2024_MES_640856_1
88651/TEZ/E8
Open Tender
Civil Works
Lump-sum
545 days
Tezpur
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (AF) TEZPUR
₹6.5 L
Yes
20 May 2024
6 Feb 2024
1 Apr 2024
6 Feb 2024
30 Mar 2024
18 Mar 2024
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (ROAD/PATH) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -X (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIC SUPPLY S&F switch piano flush type 5/6 Amps, 230 volt, single pole, two way complete all as specified and as directed.
S&F TV socket single moudle, polycarbonate type complete with box complete all as specified and as directed.
S&F Telephone socket single moudle, polycarbonate type complete with box complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including street light GI pipe bracket of medium grade 40mm dia. ,1.5m long bend to required size and shape including two coat of aluminum paint over a coat of red oxide primer complete in all respect all as specified and directed.
M&L for LED bulb 10 watt warm white complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. Note : (a) Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate. (For External and Internal Electrification)
INTERNAL WATER SUPPLY S&F brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia. bore complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply and laying of Centrifugally cast (spun) Ductile iron pressure pipes with spigot and socket joint of 100mm bore, Class K-7, bearing ISI mark with specification as IS-8329/2000 (latest revision) suitable for (push on) rubber gasket jointing with centrifugally applied inside cement mortar lining with sulphar resistant cement and external metallic zinc coating with a finishing layer of black bitumen coating on external surface suitable for treated water supply and including rubber gasket joint in any length laid in trenches complete all as specified and directed. Note :- Cost of flanged joint to be included in quoted rate.
S&F ductile iron pipes special fittings (Bends any type, radius an angle tapers any type, straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, 'Y' junction, double branch, cross) all socket and spigot collars type, cap and plugs up to 100mm bore as per site requirement, complete all as specified and directed.
Construction of brick masonry valve pit of size 90cm x 90cm x 90cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level including three coats of white wash on plastered surface providing valve pit 50 x 50 x 6mm angle iron frame all-round the fixed point by means of 4Nos holdfast 150mm long made out of flat iron 40 x 6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) of size 230 x 200 x 100mm including provision of hinges welded with angle iron frame and MS cover 5mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65mm dia pad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in any type of soil complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply and fixing LED street light fitting 70 Watt , 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including street light GI pipe bracket of medium grade 40mm dia. ,1.5m long bend to required size and shape including two coat of aluminum paint over a coat of red oxide primer complete in all respect all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
S&F cable junction box IP-66, halogen free and weather proof for outdoor installation of street lights, of size (155 x 210 x 92) mm fixed on pole complete with terminals suitable for cable size 10 Sqmm 2 core etc. including 6 Amps MCB mounted with suitable bus bar, fixed with suitable size MS clamp including provn of cable glands for street light in each pole complete all as specified and as directed.
Supplying and laying PVC insulated and FR PVC sheathed, Copper conductor, (flexible) industrial cable, 1100 Volts, conforming to IS 694 electric control cable with copper conductor, 1100 volts grade, cross sectional area 1.50 Sqmm 3 Core complete all as specified and as directed.
Supply installation, commissioning and testing in replacement, including providing all necessary electrical connection, LT feeder pannel board (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of 3.15 mm thick MS sheet of size 1.0m (height) x 1.5m (width) x 0.5m (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc. complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed
Serial Item No. 11.17 (Contd....) BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid anodized copper bus bars, rated 400 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - Set of 4, 1 No. INCOMER (a) MCCB 200 A fixed type, 415 Volts 4 pole, 36 KA - 01 No Incoming OUTGOING FEEDERS (a) MCCB 125A fixed type, 415 Volts 3 pole, 25 KA - 02 No. ( 01 Nos outgoing and 01 No Spare) (b) MCCB 80A fixed type, 415 Volts 3 pole, 25 KA - 01 No. outgoing INDICATING DEVICES (a) LED Indicating lamps for main supply indicating 'R', 'Y', 'B' - Set of 3. (b) Digital Voltmeter (96mmx96mm) 0-500 Volt -1No. (c) Digital Ammeter 0 to 200 Amps, square type (96mmx96mm) - 01 No. (d) Internal connection through copper wire (e) Non hygroscopic fiber bushes and brass screws
PRIME COST SUM. The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249. (a) Provide a prime cost of Rs. 10,00,000.00 for Provision of Modular kitchen cabinate with electric chimney in officers quarter (Total - 10 quarters) as approved by GE. (b) The contractor is to quote the amount in the money column i.e. in Col 'M' adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes :- (i) Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit. (iii) Percentage shall be derived automatically by the system in the excel sheet of BOQ based on the amount quoted against this item by the bidder. Percentage (plus/minus) subject to maximum of 15% (on plus side) shall be taken as the PC sum percentage.
Note:- Schedule of credit (Sch 'A' Part- XI amount of Rs 63,000.00 shall be deducted from the total quoted amount of BOQ.
M/S MOHANPASARI
A K BANSAL AND CO
VARNI BUILDERS
M/s KASHMIRA SINGH BARMI AND SONS
AKASH CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .