Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Overall accepted as L1 | |
| 2 | L2₹26.9 L+₹2.2 L (9.02%)Rejected-AOC 288 RANIPUR MORE HARIDWAR 249401 | HARIDWAR | UTTARAKHAND | 249401 | L2 | Rejected-AOC Overall rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical The Bidder did not qualifies the TQR |
| Sl No | Description | Qty | Unit | KARAN SUPER ELECTRICAL WORKS L1 | United Engineers L2 |
|---|---|---|---|---|---|
| 1.00Centrifuging of insulating oil of following transformers installed at 220KV S/s, Kamaluaganja, Haldwani and 132KV S/s, Bhowali including all associated works as per standard procedures including cost of all consumables, labour and T&P complete in all respect. | |||||
| 2.00 | 100 MVA, 220/132 KV Transformer-1st (Haldwani) | 40,700 | Ltr. | 5,20,960 ₹6,14,732.8 Lowest | 5,61,660 ₹6,62,758.8 |
| 3.00 | 100 MVA, 220/132 KV Transformer-2nd (Haldwani) | 40,700 | Ltr. | 5,20,960 ₹6,14,732.8 Lowest | 5,61,660 ₹6,62,758.8 |
| 4.00 | 40 MVA, 132/33 KV Transformer-1st (Haldwani) | 18,000 | Ltr. | 2,30,400 ₹2,71,872 Lowest | 2,48,400 ₹2,93,112 |
| 5.00 | 20 MVA, 132/33 KV Transformer-1st (Bhowali) | 16,000 | Ltr. | 2,04,800 ₹2,41,664 Lowest | 2,20,800 ₹2,60,544 |
| 6.00Pre-comissioning testing (Open circuit test, short circuit test, vector group test, voltage ratio test, stability test, MVT, MCT, IRPI, WRM, insulation test, winding resistance test, tan delta test etc. including testing of HV and LV side bays equipments i.e. CBs. CTs, PTs, C&R Panel, RTCC Panel etc.) of following transformers installed at 220KV S/s Kamaluaganja, Haldwani after completion of centrifuging and submission of test reports in three (03) copies jointly signed with O&M and T&C wing of PTCUL before charging of transformer including cost of all consumables, labour and T&P complete in all respect. | |||||
| 7.00 | 100 MVA, 220/132 KV Transformer-1st (Haldwani) | 1 | Job | 1,28,000 ₹1,51,040 Lowest | 1,35,000 ₹1,59,300 |
| 8.00 | 100 MVA, 220/132 KV Transformer-2nd (Haldwani) | 1 | Job | 1,28,000 ₹1,51,040 Lowest | 1,35,000 ₹1,59,300 |
| 9.00 | 40 MVA, 132/33 KV Transformer-1st (Haldwani) | 1 | Job | 1,28,000 ₹1,51,040 Lowest | 1,35,000 ₹1,59,300 |
| 10.00 | 20 MVA, 132/33 KV Transformer-1st (Bhowali) | 1 | Job | 1,28,000 ₹1,51,040 Lowest | 1,35,000 ₹1,59,300 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
11 Mar 2024, 12:00 pmClosed
Chief Engineer
Office of CE, OandM, Kumaon Zone, PTCUL, Haldwani
Diagnostic maintenance of transformers installed at various substations under 220KV OandM Division, PTCUL, Haldwani
2024_PTC21_70568_1
CE(OandM)/PTCUL/HLD/40/2023-24
Open Tender
Electrical Works
Item Rate
180 days
220KV S/s, Haldwani and 132KV S/s, Bhowali
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,360
EE, 220KV OandM Division, PTCUL, Haldwani
₹88,000
Office of CE, OandM, Kumaon Zone, PTCUL, Haldwani
8 Sept 2025
29 Feb 2024
11 Mar 2024
29 Feb 2024
11 Mar 2024
29 Feb 2024
7 Mar 2024
Centrifuging of insulating oil of following transformers installed at 220KV S/s, Kamaluaganja, Haldwani and 132KV S/s, Bhowali including all associated works as per standard procedures including cost of all consumables, labour and T&P complete in all respect.
100 MVA, 220/132 KV Transformer-1st (Haldwani)
100 MVA, 220/132 KV Transformer-2nd (Haldwani)
40 MVA, 132/33 KV Transformer-1st (Haldwani)
20 MVA, 132/33 KV Transformer-1st (Bhowali)
Pre-comissioning testing (Open circuit test, short circuit test, vector group test, voltage ratio test, stability test, MVT, MCT, IRPI, WRM, insulation test, winding resistance test, tan delta test etc. including testing of HV and LV side bays equipments i.e. CBs. CTs, PTs, C&R Panel, RTCC Panel etc.) of following transformers installed at 220KV S/s Kamaluaganja, Haldwani after completion of centrifuging and submission of test reports in three (03) copies jointly signed with O&M and T&C wing of PTCUL before charging of transformer including cost of all consumables, labour and T&P complete in all respect.
100 MVA, 220/132 KV Transformer-1st (Haldwani)
100 MVA, 220/132 KV Transformer-2nd (Haldwani)
40 MVA, 132/33 KV Transformer-1st (Haldwani)
20 MVA, 132/33 KV Transformer-1st (Bhowali)
Testing of transformer oil (BDV, Acidity, Interfacial Tension, DGA) of following transformers from NABL accredited labs after completion of centrifuging and charging of transformers including collection of transformer oil samples from main tank (top & bottom) and OLTC, its transportation and submission of test results in hard & soft copies as per direction of engineer incharge including cost of all charges, labour and T&P complete in all respect.
100 MVA, 220/132 KV Transformer-1st (Haldwani)
100 MVA, 220/132 KV Transformer-2nd (Haldwani)
40 MVA, 132/33 KV Transformer-1st (Haldwani)
20 MVA, 132/33 KV Transformer-1st (Bhowali)
Condition monitoring of 20 MVA, 132/33 KV Transformer-1st at 132 KV substation Bhowali by conducting following tests and submission of signed reports in hard & soft copies. (a) Capacitance & Ten Delta of Bushing & Windings. (b) Turns Ratio Test. (c) Vector Group Test. (d) Short Circuit Impedence Test. (e) Magnetizing Current Test (Each Tap). (f) Magnetic Balance Test. (g) Winding Resistance Test. (h) Insulation Resistance Measurement. (i) Sweep Frequency Response Analaysis (SFRA). (j) Frequency Respones on Stray Load (FRSL). (k) Leakage Reactance & Impedence Measurement. (l) Online Partial Discharge Measurement Test . (m) Thermographic Measurement Test. (n) Noise Measurement Test. (o) Vibration Measurement Test.
United Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .