Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 4 | Admitted-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | Admitted-Finance |
Tender Value
₹34 L
EMD Value
₹76,000
Closing Date
28 Oct 2020, 6:00 pmClosed
GE (N) TEZPUR
GE (N) TEZPUR
REPAIR/REPLACEMENT OF STREET LIGHTS INCLUDING CONNECTED WORKS AT CERTAIN LOCATION IN ZONE 7,8,9 AND REPAIR/MAINT OF LIGHTING CONDUCTOR CONNECTED ITEMS AT NAA UNDER GE (NORTH) TEZPUR
2020_MES_372086_1
GE(N)/TEZ/2020-21/8429
Open Tender
Civil Works
Item Rate
180 days
TEZPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (N) TEZPUR
₹76,000
Yes
3 Nov 2020
1 Oct 2020
30 Oct 2020
1 Oct 2020
28 Oct 2020
16 Oct 2020
1 Oct 2020 - 15 Oct 2020
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Dismentaling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, integral wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting all as specified and as directed. Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items.
Taking down down/dismantling old/rusted/deshaped cross arms/MS channel or angle for reuse complete all as specified and directed.
Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material complete all as specified and directed.
Dismantling of ACSR conductors of any description,stacking serviceable conductor aside for reuse and removing unsv/broken conductor complete all as specified and directed.
Taking down down/dismantling old/broken stay assembly complete including demolition of concrete, etc. and excavation complete all as specified and directed.
Dismantling /taking down old rusted /broken GI earth wire from feeder or distributor span complete all as specified and directed.
Taking down down/dismantling old/rusted/broken steel poles/struts,removing from site and making good disturbed surface complete all as specified and directed.
Supply & Fixing in replacement of the following spare parts in street lights :-
PVC insulated weather proof sheated alluminium cable 2.5 sq mm 2 core
LED Driver 25 Watt of Make Bajaj/Equivalent
LED Driver 30 Watt of Make Bajaj/Equivalent
LED Driver 45 Watt of Make Bajaj/Equivalent
Supply and Fixing in replacement New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver. suitable for 43 mm dia bracket size ( max) of rating 25W LED including connecting with 3 core aluminium conducor 2.5sqmm with Overhead conductors or UG Cables complete all as specified and directed
Supply and Fixing in replacement New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver. suitable for 43 mm dia bracket size (max) of rating 30W LEDincluding connecting with 3 core aluminium conducor 2.5sqmm with Overhead conductors or UG Cables complete all as specified and directed
Supply and Fixing in replacement New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver. suitable for 43 mm dia bracket size ( max) of rating 45W LED including connecting with 3 core aluminium conducor 2.5sqmm with Overhead conductors or UG Cables complete all as specified and directed
Supply and fixing in replacement of LED Post Top Lantern of New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light sourceof 25 Watt LED including fixing on 40mm dia grouted in post complete with and including angle iron cage as per existing shape and size of piller to protect the any damage by monkeys.all as specified and directed .
Material and Labour for path light LED bollard 7W to 10W in cylindrical shape with opal acrylic diffuser and IP 65 & IK-10 protection with silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landscape enironment fixed on PCC block 1:4:8 type D2 40mm graded all as specified and directed.
M&L for street light bracket made out of 32 mm dia GI pipe medium grade 120 cm long cut to size and bend to shape , fixing on poles with flat iron clamps 40mm x 6 mm – 02 sets including nuts, bolts and washers including one coat of aluminium pait over acoat of red oxide primer including taking down of old unserviceable complete all as specified.
Material and labour for replacement of junction boxes with new Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable off Size 155 X 210 X 92 mm incl busbar fixed in repairs and including Necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes and complete all as specified and directed by Engr-in-Charge. Make Cat No. KF1616G of Hensel or euivalent
Material & Labour for fabrication of Sheet metal enclosure , powder coated of Timelite Distribution Boards for automatic Switching of street lights internally pre wired by using suitable copper lugs including fixing with MS Clamp40X5 mm to steel/RCC poles incl connection consisting of the following (i) ASTRONOMICAL time switch 24 hrs operation 240 Volts Cat Part No.AUTS02AST00 of L&T or Equivalent of Legrand/Scneider (ii)3 pole contactor 40Amps Cat Part No.Cat No. CS 94190 of L&T (iii) MCB FP 32 Amps Cat Part No. Cat No. BB40320C of L&T or Equivalent in Legrand/Schneider
Supply and fixing as in replacement of Time Switch, Digital control,Astronomical type suitable for daily operation in 230 volts AC supply
Supply and fixing as in replacement of three pole power contactor with control relay with AC Coil suitable for operation in 415 volts AC supplywith 230 volt relay coil and current rating 40Amps.
Supply and fixing as in replacement of MCB FP 32A 'C' Type for operation in 230/415 volts AC supply.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 20mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion , complete all as specified and directed.
M/L in replacement for cross arms, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified.
M&L in replacement of shackle type Insulator porcelain vitreous white/ brown or green, 75 mm high and 90mm dia suitable for working pressure of 1100 Volt including Galvanized mild steel straps of size 31x3 mm , nut, bolt of dia 12 mm and washers of suitable size, complete all as specified and directed.
M&L in replacement of pin Insulators Porcelain vitreous white or green including Galvanized mild steel spindle, two GI washers and one GI nut of size suitable for 1100 Volt electric pressure complete all as specified and directed.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 using 40mm graded sone aggregate for foundation and coping with PCC 1:2:4 using 20mm stone aggregate and smooth finish complete all as specified and as directed.
Taking down LT UG Cables of any size from trenches/poles complete after disconnection all as specified and directed
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 2 core.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core.
Supply & fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tap and over all PVC sheadthed in service connection 6 Sqmm flat twin core all as specified and directed.
Supply & fixing 1100 volts grade PVC insulated stranded aluminium conductor single core 1.5 Sqmm with and PVC conduite medium grade notless than 19/20mm dia fixed with RCC/steel tubular pole clamp or by any other means all as specified and directed.Note PVC conduite will be measured and paid seperately.
Supply & fixing PVC conduite along with RCC/Steel tubular poe, medium grade ISI marked not less than 19/20mm dia fixed with ms clamp or by ms wire all as specified and directed.
M&L for 50 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc, or for shafts, wells, cesspits, man holes, pier holes etc not exc 10 sq m on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and directed.
Supply and laying in trenches brick common burnt clay building brick, sub class 'B' designated- 75 with width equal to length of brick for cable protection complete
M&L for PCC (1:4:8) type D2 using 40 mm graded aggregate as in foundations of Poles and filling of mass concrete complete all as specified
Taking down carefully existing aluminium strip of size 25x3mm and GI strip of size 32x6mm fixed in position as lightning conductor from roof/wall and buried in ground including making good the disturbed surfaces etc complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully existing air termination rod any type and size from roof complete all as specified and directed by the Engineer-in-Charge.
Taking down old unserviceable earthing, dismantling of earth pit including other accessories and removing from site of work complete all as specified and directed by the Engineer-in-Charge.
Fixing only aluminium strip of size 25x3mm obtained from item No. 1 above after necessary repairs (like removing denting/bend rejoining tightening properly by GI bolts and nuts securing, tightly by MS clamps of suitable size for roof/conductor/down conductor above ground level including jointing properly by existing GI/Aluminium strips, air termination rod and insulators) complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing aluminium strip 25x3mm size secured tightly on hole by MS clamps of suitable size for roof conductor/down conductor above ground level including making connection with existing air termination rod/GI strip and fixed with insulators/ shaddles complete all as specified and directed by the Engineer-in-Charge.
Materials and Labour for Earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to copper strip 20x3mm as earth lead means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 32 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed complete all as specified and directed.
Material & labour and fixing GI strip of size 32x6 mm buried in ground fixed on poles/MS flat iron clamps of suitable size in trenches including necessary fixing arrangement such as fasteners, nut bolts and washer etc complete all as specified and directed by the Engineer-in-Charge.
Fixing only air termination rod obtained from item No. 2 here-in-before securing tightly to poles/GI pipe on roof strip by clamps of flat iron 25x3mm making connections with aluminium conductors and down conductors complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing air termination single pointed aluminium rod 12mm dia and 30mm long including GI nut 12mm dia 2 Nos GI washers 12mm dia 2 No’s, screwed at bottom and fixed properly to down conductor on pole/GI pipe MS clamp of flat iron 25x3mm complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia, 25mm long hex head screw complete all as specified and directed by the Engineer-in-Charge
Supply and fixing galvanised Iron pipe light grade of size 40 mm dia with all fitting accessories complete all as directed by Engineer-in-Charge. ISI Marked
PURBANCHAL BUILDERS
Flint India
M/S Harjinder Singh Contractor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .