Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAdmitted-Fee/PreQual/Technical/Finance C O SACHINDRA MAJUMDER ASSAMPARA 0 RANIR BAZAR WEST TRIPURA TRIPURA 799035 | WEST TRIPURA | TRIPURA | 799035 | ₹8.7 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹10.3 L+₹1.6 L (18.5%)Admitted-Fee/PreQual/Technical/Finance NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹10.3 L+₹1.6 L (18.5%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Eastern Commerce L2 | CHANDAN MAJUMDER L1 |
|---|---|---|---|---|---|
| 1.00Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU). surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU) copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407, Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 1 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part I1 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only | |||||
| 1.01 | 1.5 TR with 3 Star BEE Rating. | 4 | Jobs | 40,000 ₹1,60,000 Lowest | 41,300 ₹1,65,200 |
| 1.02 | 2.0 TR with 3 Star BEE Rating. | 12 | Jobs | 53,000 ₹6,36,000 | 51,500 ₹6,18,000 Lowest |
| 2.00 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. | 96 | Mtr | 1,900 ₹1,82,400 | 485 ₹46,560 Lowest |
| 3.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes or suitable creadle i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 16 | Nos | 1,600 ₹25,600 | 980 ₹15,680 Lowest |
| 4.00 | Providing hard uPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 97 | Mtr | 90 ₹8,730 Lowest | 95 ₹9,215 |
| 5.00 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Square mm Copper Cable. | 96 | Mtr | 89 ₹8,544 | 75 ₹7,200 Lowest |
| 6.00 | Providing & Charging fresh refrigerant gas (R-410) for 1.5/2.0 TR High wall split AC system as per direction of Engineer -in- charge | 6 | Kg | 1,500 ₹9,000 | 1,250 ₹7,500 Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,675
Closing Date
12 May 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division
Providing installation and commissioning of 1 5 2 0 TR Split Type High Wall Air Conditioning Machines in different office rooms of the establishment of Medical Superintendent Gomati District Hospital Tepania during the year 2025 26
2026_CEPWD_72301_1
106_EE_DNIT_MECHDIVN_AGT_2526
Open Tender
Electrical Works
Works
30 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹19,675
9 Jun 2026
30 Apr 2026
12 May 2026
30 Apr 2026
12 May 2026
30 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU). surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU) copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407, Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 1 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part I1 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only | |||||
| 1.01 | 1.5 TR with 3 Star BEE Rating. | 4 | Jobs | - | - |
| 1.02 | 2.0 TR with 3 Star BEE Rating. | 12 | Jobs | - | - |
| 2 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. | 96 | Mtr | - | - |
| 3 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes or suitable creadle i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 16 | Nos | - | - |
| 4 | Providing hard uPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 97 | Mtr | - | - |
| 5 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Square mm Copper Cable. | 96 | Mtr | - | - |
| 6 | Providing & Charging fresh refrigerant gas (R-410) for 1.5/2.0 TR High wall split AC system as per direction of Engineer -in- charge | 6 | Kg | - | - |
stage.html
html • 0.02 MB
finance_73579.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
DNIT.pdf
Tender Documents • 2.96 MB
BOQ_73579.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .