Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Agreement executed through treasury | |
| 2 | Rejected-Technical | - | Rejected-Technical As per board resolution taken |
Tender Value
₹17.9 L
EMD Value
₹44,650
Closing Date
8 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE, LSGD SECTION, MEPPADI
AE, LSGD SECTION, MEPPADI
CMLRRP 2020-21 KUNNAMANGALAM VAYAL PALAM ROAD AT MEPPADI GRAMA PANCHAYATH
2020_LSGD_365362_2
1/AE/2020-21
Open Tender
Civil Works - Roads
Item Rate
90 days
MEPPADI
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,980
online
₹44,650
Yes
21 Aug 2020
1 Jul 2020
13 Jul 2020
1 Jul 2020
8 Jul 2020
1 Jul 2020
45 days
Amount
CONSTRUCTION OF SMALL BRIDGE
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
3.9.2.A : Excavation in Hard Rock (blasting prohibited)Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5(A)Manual Means
od680857/2020_2021 : DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of<br>2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a<br>depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc<br>complete.
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
od681204/2020_2021 : Providing Weep Holes to Cement Concrete Retaining Wall using 63mm 4kgf/cm2 PVC<br>Pipes, as per the direction of Engineer-in-Charge.
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
12.5.2.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mII.P.C.C. grade M 20 (i)Nominal mix (1:2:4)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
od699865/2020_2021 : Providing concrete for plain/reinforced concrete in super structure (WITH<br>FORMWORK) complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 .P.C.C grade M 10, Nominal mix 1:3:6<br>
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
od683423/2020_2021 : Providing Wearing Coat in CC Drain using plain cement concrete as per drawings and<br>direction of Engineer-in-Charge (11.4.4 Modified) Nominal Mix 1:2:4
11.4.2.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
od683217/2020_2021 : Filling with contractor's own earth ( excluding rock) in OPEN AREAS in layers not<br>exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and<br>lift up to 1.5 m as per direction of site Engineer-in-charge.
od685964/2020_2021 : Construction of Plain Cement Concrete Pavement (WITHOUT FORM WORK):Mord Item 6.4 Modified Construction of Plain Cement Concrete Pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 (M 20 grade),coarse and fine aggregates conforming to IS 383(maximum size of coarse aggregate not exceeding 25 mm)mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side form work(steel channel, wedges,steel plates including leveling the form work as per drawing),laying and fixing of 125 micron thick polythene film, wedges,steel plates including<br>levelling the formwork as per drawing),spreading the concrete with shovels,rakes,compacted using<br>needle vibrators and finished in continuous operation including provision of contraction<br>and expansion ,construction joints,applying debonding strips, primer, sealant, dowel bars, near approaches<br>to bridge /culvert and construction joints, curing of concrete slabs for 14 days ,with water finishing to lines and grade as per drawing and Technical<br>Specifications clause 1501.
10.4.A.3 : Direction and Place Identification signs with size more than 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>3 Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
G. ABRAHAM
Bidder Name
ABILASH.K.K
G. ABRAHAM
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_521731.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .