Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹36.3 L+₹1.5 L (4.34%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹37.3 L+₹2.5 L (7.24%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
Tender Value
₹48.9 L
EMD Value
₹97,700
Closing Date
7 Nov 2023, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
PERIODICAL MAINTENANCE, REPAIR AND REPLACEMENT OF UNSERVICEABLE ITEMS OF DC SUPPLY BATTERY CHARGERS, POWER PACKS, BATTERIES AND OTHER CONNECTED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2023_MES_622461_1
8914/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM Visakhapatnam
₹97,700
Yes
20 Apr 2024
10 Oct 2023
14 Nov 2023
10 Oct 2023
7 Nov 2023
24 Oct 2023
Amount
Disconneting and taking down old damaged lead acid batteries from various sub-stations and supply & fix new maintenance free (VRLA) 2Volts, 200AH, batteries united/ fixed together with copper strips by series connection to make a battery bank of 110 V with initial charging and commissioning complete all as specified and as directed. Make : Amara Raja/Exide Note : Unit rate quoted shall be deemed to be included for providing necessary battery connection links and control wiring from charger to HT panels.
S&F DC power pack on 11 KV VCB, capacity- 230 V AC input, 110V DC output , 150AH including necessary connection from AC input point and out put connection to VCB panel including dismantling taking out unserviceable one complete all as specified and as directed. Make :- Gogate electro systems Pvt Ltd/ Alan Power pack
Supply and fix copper cable single core of size 10 sqmm incl terminals all as specified and directed. Make:- Plaza/Polycab/Finolex/KEI.
Supply only Space heater-100W-240VAC all as specified and directed.
Supply only HBC fuse-slow-50A-660VAC offset tag all as specified and directed.
Supply only Glass fuse-fast-1A-250VAC-20mm all as specified and directed.
Supply only Semiconductor fuse-fast-25A-250V AC all as specified and directed.
Supply only Glass fuse fast 6A 250V AC 20mm all as specified and directed.
Supply only HRC fuse-slow-20A-415/550VAC-clip on all as specified and directed.
Supply only DC Voltmeter 0-150V -1.5-90D-(96) all as specified and directed.
Supply only DC Ammeter-50-0-50A/75mV-1.5-90D all as specified and directed.
Supply only DC Ammeter-0-40A/75mV-1.5-90D all as specified and directed.
Supply only AC Voltmeter -0-500V-1.5-90D-(96) all as specified and directed.
Supply only AC Ammeter-0-25A/5A-1.5-90D-(96) all as specified and directed.
Supply only PCB-MST-ACDB-48VDC all as specified and directed.
Supply only PCB-PLA-RL-130VDC all as specified and directed.
Supply only PCB-MST-UV/OV-RD-110V all as specified and directed.
Supply only PCB-CUR LIMIT-INT.FACE-130V DC all as specified and directed.
Supply only PCB-POWER SUPPLY BD-6P all as specified and directed.
Supply only PCB-REG CTRL-110VDC-6P all as specified and directed.
Supply only PCB GATE PULSE DRIVER-6P all as specified and directed.
Supply only PCBN-PLA-RELAY-12VCB-3C/O CONT all as specified and directed.
Supply only MCB-16A - 2P-DC-10KA all as specified and directed.
Supply only MCB-63A-2P-DC all as specified and directed.
Supply only MCB-32A-3P-10KA-AC-D-Cure all as specified and directed.
Supply only MCB-50A-2P-DC all as specified and directed.
Supply only Resistor-variable-2.5K-25k-25W-wire wound all as specified and directed.
Supply only POT-panel mount-20K-3W-1T all as specified and directed.
Supply only Dual SCR block-slow-25A-600V all as specified and directed.
Supply only PCB alram Bd-26V-43VDC-I/P-ARE02017023 all as specified and directed.
Supply only Short cuircuit in AC Pla relay bases all as specified and directed.
Supply only Fuse trip indicators all as specified and directed.
Supply only PCB volt detect 48VDC TB all as specified and directed.
Supply, fix and testing indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on charger panel board suitable for 240 V AC supply including providing controll wiring and taking down unserviceable indication lamps all as specified and directed. Make - L&T/binay/C&S/Tecnik
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 25 Sqmm 4.0 core and connection complete with aluminium cable lugs incl dismantling taking down unsv one all as specified and directed.
Dismantling taking out LT/HT cable from panel/transformer/floor of sub station for repair or for realingnment and refixing the cables with proper staking and proper alingnment and refixing the cables properly on repaired/existing rack/trench and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3.0/3.5 core 95 sqmm to 185 sqmm 11000/1100 volt grade including required alumium thimbles all as specified and directed Note : Each cable shall be measured separately.
All as per item No. 37 above, but for cable sizes 240 sqmm
All as per item No. 37 above, but for cable sizes 300 sqmm
All as per item No. 37 above, but for cable sizes 400 sqmm
M&L for setting of 3 ph overcurrent + earth fault numerical relays by secondary injection of current to CTs with suitable equipment for overcurrent & earth fault with high set and low set including checking of all other parameters of relays for proper tripping order after disconection of incoming or out going HT XLPE cable connection from VCB CTs and reconnection of cable ends at existing terminals after completion of relay setting complete all as specified and directed. (Note: (a) Relay setting shall be made considering corresponding values of upstream and down stream VCB relays and recorded maximum demand of VCB. Any further adjustment of values as many times require shall be carried out within the quoted rate. (b) Recovery shall be made double the quoted rate if VCB fails to trip in indicated fault and if group tripping recorded)
Supply and applying Si-COAT 570 RTV Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber, testing complete all as specified and directed. Make:- CSL Silicones Inc. Canada or Equivalent
Supply and applying Si-COAT 570 RTV Silicone High Voltage Insulator Coating solution using an Sprayer to the 11KV Indoor VCB panel Cable chamber min 500 micron thickness coating shall carried out for achiving insulation value of 11KV supply complete all as specified and directed. Make:- CSL Silicones Inc. Canada or Equivalent Note for item No. 42 & 43 : (a) Surface preparation: All insulation surfaces of the equipment to be coated shall be made free from dust, grease, oil and any other foreign material without damaging the surface. The surface of the equipment shall be made dry before application of the RTV coating. (b) All the required materials, tools & tackles, testing equipment, consumables etc. for application of HVIC coating shall be in bidders’ scope. (c) As per manufacturing insutructions minimum thickness of 500 microns shall be coated on overall inside panel body, busbars, expoxy items for achiving dilectric/insulation strength of 11KV supply
Supply & fixing 132KV, horizontal double break isolators "GRPS" make, 132 KV, triple pole, 31.5 KA centre post rotating horizontal double break type isolators suitable for upright mounting with manual operated mechanism for main switch and earth switch (i.e. mechanically gang operated) with all accessories required for normal operation of the isolator, but without support insulators, without supporting structure and without terminal connectors with following configuration (copper design) : - a) For 800 Amps with one earth switch. b) Support insulators for the above isolators. One stack consisting of 325 KV having a creepage distance of 4495 mm and cantilever strength of 6 KN as manufactured & tested (31mm/KV) (Per No.). c) Terminal connectors for the above isolators a set of 06 Nos. Rigid type bimetallic terminal connectors suitable for single ASR Zebra conductor.
M&L for cleaning of HT indoor cable kit at VCB end after opening VCB panel back side cable cover and bottom cable entry plate after disconneting all cable end from busbar/CT, taking out from VCB cable chamber, checking for serviceability, cleaning & decarbonising complete cable kit and aluminium cable lugs using CTC and refixing the same to original position, with new or old nuts, bolts & washers and making cable entry point totally sealed with putty complete all as specified and directed. Note: Required CTC, new nuts, bolts, washers shall be inclusive of quoted rate. Serviceable cable ends will only be measured.
CHINNI ELECTRICAL ENGINEERING WORKS
UV POWER TECH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .