| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 26 NETAJI STREET DEHRADUN UTTARAKHAND | ₹3.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.4 Cr+₹29.1 L (9.47%)Rejected-Finance 11 NARENDRA VIHAR BALLUPUR ROAD DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹3.4 Cr+₹29.1 L (9.47%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.7 Cr+₹60.4 L (19.6%)Rejected-Finance | ₹3.7 Cr+₹60.4 L (19.6%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹3.6 Cr
EMD Value
₹7.3 L
Closing Date
28 Sept 2022, 5:00 pmClosed
Superintending Engineer
Office of Superintending Engineer Construction Circle UKPJN Dehradun
Construction of civil engineering laboratory at kamla nagar dehradun
2022_MDPEY_49177_1
Letter No. 3356/Nivida/663, dated 05.09.2022
Open Tender
Civil Works
Item Rate
365 days
Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer Construction Division UKPJN
₹7.3 L
Dehradun
3 Oct 2023
8 Sept 2022
30 Sept 2022
8 Sept 2022
28 Sept 2022
14 Sept 2022
12 Sept 2022
Amount
EARTH WORK Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Carriage of material by Mechanical Transport including loading,unloading and stacking of lead 15 Km.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level:: M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth and upto floor V level: M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
REINFORCED CEMENT CONCRETE WORK(M25) Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement, including admixtures inrecommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
Centring and shuttering including strutting,ropping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. sqm
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
MARBLE WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeGranite of any colour and shade:Area of slab over 0.50 sqm
DOOR & WINDOWS
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). each
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Renewal of old putty of glass panes (length)
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. : Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete.
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : 25 mm dia
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
FINISHING
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm thick cement plaster in cement mortar 1:6 on Rough Side of brick wall including supply of all material , labour and T&P etc.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
G.I. PIPES
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.. External work
80 mm dia nominal bore
G.I. UNION
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
80 mm dia nominal bore
BALL VALVE
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
NON-RETURN VALVE
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
50 mm nominal bore : Horizontal
LONG BIB COCK
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
STOP COCK
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
ANGLE COCK
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supply and fixing of kIRLOSKER Centrifugal Self Priming Mono block Pump (KIRLOSKAR & SP2HM) Pump Type Self Priming Mono block Pump, Size (Dia) of solids in liquid to be handled 15.5 millimeter, Suction Pipe size (Nominal) 50 millimeter, Delivery pipe size (Nominal) 50 millimeter, Speed in RPM 2900 Impeller Material Cast Iron, Motor Type AC Motor ISI Marked 3 Phase , 415 V ± 10%, 50Hz±3%Hz complete in all aspects as per direction of Engineer In-charge
INDIAN W.C
EUROPEAN W.C.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
WASH BASIN
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap
LABORATORY SINK
1 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
MIRROR
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
TOWEL RING
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
SOAP DISH
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
SOIL PIPES
Providing and fixing soil , waste and vent pipes: Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
100 mm dia
75 mm dia
CLAMPS
Providind and fixing M.S.holder bat clamps of approved design to sand cast iron/cast iron (squn) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1cement :2coarse sand :4graded stone aggregate 20mm nominal size ) including cost of cutting holes and making good the walls etc:
for 100 mm dia pipe
for 75 mm dia pipe
BENDS
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
100 mm diameter pipe
75 mm diameter pipe
Providing and fixing 100 mm sand cast iron S&S plain bend of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
100 mm diameter pipe
75 mm diameter pipe
Providing and fixing heel rest sanitary bend.
100 mm diameter pipe
75 mm diameter pipe
Providing and fixing double equal plain junction of required degree. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
100x100x100x100 mm
75x75x75x75x75 mm
Providing and fixing single equal plain junction of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing double unequal plain junction of required degree: Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
100x100x75x75 mm
Providing and fixing single unequal plain junction of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing double equal plain invert branch of required degree: Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
100x100x100x100 mm
Providing and fixing single equal plain invert branch of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing single unequal plain invert branch of required degree : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing Hubless centrifugally cast iron offsets epoxy coated inside & outside as per IS:15905
130 mm offsets With 100 mm dia
FLOOR TRAP
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989
Providing and fixing C.P. brass bottle trap for wash basin including CP waste fittings complete 32 mm dia complete in all respect of approved quality.(Jaquar)
TERMINAL GUARD
Providing and fixing terminal guard 100 mm Sand cast iron S&S as per IS - 1729
COLLAR
Providing and fixing collar :
Providing and fixing on wall face unplasticised Rigid PVC rain water pipe:- 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories :-coupler 110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories :-Bend 87.5° 110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes :- 110 mm
Providing and fixing Gyeser (Water Storage Heater) 25 Litres Capacity make Jaquar
DRAINAGE
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 600 mm dia RCC pipes.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded 300 mm diameter S. W. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for manholes Size 120x90 cm With F.P.S brick class designation 75
ELECTRICAL WORK
SUB HEAD - I SCHEDULED ITEMS
WIRING
WGSTLPT Point wiring in PVC conduit, with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
WGSTLMIDTC Twin Control point wiring in PVC conduit, with modular type switch:
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
WGSTLPP2 Power plug wiring in PVC conduit (2x4 sq. mm)
Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
WGSTLSB Circuit/ submain wiring in PVC conduit:
Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
TLWGEC Telephone wiring in PVC conduit:
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
PVCCON S/F PVC conduit:
Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required.
MB S/F metal boxes:
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
75 mm X 75 mm X 60 mm deep
PTSWEB S/F modular type switch/ socket:
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Telephone socket outlet
MODFREB S/F modular type electronic fan regulator:
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
LPACCPT S/F light plug point modular type accessories:
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
PPACCPT S/F power plug point modular type accessories:
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
CREB S/F ceilling rose:
Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
BRHOLD S/F brass holder:
Supplying and flxing brass batten/angle holder including connection etc. as required.
ITCFFSUR ITC fluorescent fitting directly on surface:
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITCCFFC ITC ceiling fan with cover on fan box:
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
ITCEF450 ITC exhaust fan upto 450 mm sweep:
Installation of exhaust fan upto 450 mm sweep in the existingopening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
LOUSHEF Fixing louvers/shutters for exhaust fan:
Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes.
BOARD & DB'S
PWTPMCBDB S/F TP MCB DB:
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
6 way (4 + 18), Double door
MCBTPIS S/F TP MCB isolator:
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required.
MCBC S/F 'C' curve, SP MCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
CABLE TRAY
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
600 mm width X 50 mm depth X 2.0 mm thickness
EARTHING
EARGIPL G.I earth plate elctrode:
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required..
EARG125X6 S/L 25 mm x 5 mm G.I. earth strip in ground:
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
SUB HEAD - II (NON SCHEDULED / EXTRA ITEMS)
CEILLING FAN
Supply and fixing of 1200MM SWEEP Ceiling Fan with Regulator Model : Double Ball Bearing, Sweep : 1200mm, Body : Cast Aluminium (Both top and bottom) Colour : White, Accessories : Complete Body with Blades, Downrod, Canopies (2 numbers), Fixing Clamps & Rubber Bush. Regulator : Resistance / Switch type Electronic Input supply : Single phase 230VAC +/-10% ; 50Hz +/-5%, Make : Usha / Orient / Khaitan / Crompton Greaves/Havells / Bajaj / Almonard / Calcutta Fans complete in all aspects as per direction of Engineer In-charge
1200 mm sweep
Supply and fixing of 200MM SWEEP exhaust fans Sweep size 200 mm, No. of blades 6, Switch No, Guard No, Motor speeds (No.) 1, Motor type Normal Speed, Remote control option No, Oscillation No, Body colour White, Finish Glossy, Blade finish Opaque, Blade design Aerodynamically designed & Balanced Blade, Air delivery 520 m³/h, Rated Speed 1350 revolution per minute, Noise level 42 dB, Power consumption 32 W, Rated voltage 230 V, Rated frequency 50 Hz, Packaging dimensions WxHxD 33 cm x 15.5 cm x 33.3 cm, Weight 1.5 kg, Motor protection through thermal overload protection device N0, Guarantee 2 Year. complete in all aspects as per direction of Engineer In-charge
200 mm sweep
Supply and fixing of 18 Watt/1800 lumen 6500 K LED Tubelight, Type of Tube Light Cap G-13 Bi-pin, Ingress Protection in IP IP 20, Lamp Shell material Polycarbonate, Length of tube light 1220mm, LED lamp efficacy (Lm/W) 100, Colour Rendering Inde (CRI) > / = 80, Total Harmonics (%) < / = 15%, Beam Angle (Degree) > / = 120 degree, Operating Voltage range (Volt) 100-300, Driver Efficiency (%) more than 85%, Surge Voltage withstand (KV) 2.5 KV, LED Chip Efficacy (Lm/W) 130, Rated Voltage for Performance and life (Volt) 220-240, Lumen Maintenance at 25 deg;C after 6000 hrs (%) 80%, LED Chip Wattage (Individual) (Watt) 0,25, Power Factor > / = 0.9, complete in all aspects as per direction of Engineer In-charge
Supply and fixing of LUMINOUS 2 KVA Without battery 3 Star without trolley Sine Wave Inverter,Rating in KVA & Min. VAH Capacity of Battery: 2 KVA Without battery,Technology : MOSFET-PWM, complete in all aspects as per direction of Engineer In-charge
Supply and fixing of LUMINOUS 12.0 Volt Volt Lead Acid Battery, Types of Lead Acid of Battery : Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1,2 & 3) with latest amendments, Nominal Voltage of Battery (volts) : 12.0 Volt, Rated Capacity at C20 discharge (AH) : 150, Warranty (Years) : 4 Years, complete in all aspects as per direction of Engineer In-charge
Supply and fixing of ANJURI RO Fully automatic with auto cut RO +UV Portable Water Purification System (10 LPH), Type of water purification technology: RO +UV, Minimum inlet pressure : 0.3 KG/CM2, Maximum inlet temperature : 35 DEGREE, Total Dissolved Solids Removal Percentage from RO Membrane : 90%, perticulate Filter Porosity : 5 micron, power supply : 230 Volt single phase, Installation Type : Wall mounted, 1 year warranty.
Supply and fixing of LAB EQUIPMENTS as per Quote, SOIL TESTING MACHINE,CALIFORNIA BEARING RATIO TEST APPARATUS , CORE CUTTER TESTAPPARATUS , SAND REPLACMENT, COMPACTION TEST, RAPID MOISTURE METER, HOT AIR OVEN, SOIL PRTMRBILITY APPARATUS, TRIAXIAL TEST APPARATUS,SWELL TEST APPARATUS, SPT TEST APPARATUS, HOT PLATE, SIEVES SET FINE, AUTOMATIC COMPACTOR ELECTRICALLY OPERATED, DIGITAL BALANCE, LIQUIDE LIMIT, CEMENT TESTING MACHINE -BLAIN AIR PERMEBILITY, VICATE APPARATUS, LE CHATELIER MOULD, DIGITAL WATER WATH, LE CHATERIER FLASK, SLUMP CONE,AIR ENTRAINMENT METER, FLOW TABLE,PLANETARY MIXER, TROWEL, CEMENT AUTOCLAVE, LENGTH COMPARATOR, SHRINKAGE BAR MOULD, VIBRATING MACHINE, MOULD 70.6, DIGITAL BALANCE, CONCRET TESTING MACHINE- Digital COMPRESSION TESTING MACHINE 2000 kn, CONCRETE MIXER 40 LITER drum type, VIBRATING TABLE ,CONCRETE PERMEABILITY, LOS ANGELES ABRASION TEST,AGGREGATE IMPACT VALUE TESTING APPARATUS, SPECIFIC GRAVITY,DIGITAL OVEN,THICKNESS GUAGE ,ELONGATION GUAGE, BULK DENSITY APPARATUS, AGGREGATE CRUSHING VALUE, SHIVES SHAKER MOTORIZED, CORE CUTTING MACHINE, CONCRETE CUBE MOULD MODEL 150X150MM, BEAM MOLUD , CURING TANK , ENAMAL TRAY , METAL SCOOPE , TROWELS, DIGITAL VERNIER CALIPER MODEL AROSPACE, SIEVE SET [COURSE] , Cylindrical mould , DIGITAL BALANCE , UNIVERSAL TESTING MACHINE , Hydrostatic pressure testing machine , Rebound Hammer , WATER TESTING MACHINE- PH METER, TDS METER, DIGITAL TURBIDITY METER, SPECTRO PHOTOMETER, HOT PLATE, HEATING ELEMENT, Water Testing Lab- BOD Incubator, COD Incubator, Humidity Chamber, Tensile Testing Machine , Digital Thickness Gauge, Softening Point for PVC pipe.Microprocessor-Based Spectrophotometer. e.t.c (As per the details & specification in the tender document)
Makin Developers Pvt. Ltd.
m/s bansal construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .