Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
22 Apr 2026, 6:00 pmClosed
Municipal Commissionar, AMC
Rate contract for Work of New Electric Service Connection, Extension/Reduction of Load From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories with Liasoning Work (LT & LTMD Services) for Different Category Electric Services of Offices, Buildings of Ahmedabad Municipal Corporation.
290806
2025-26
Open
Miscellaneous Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹900
Municipal Commissioner, Ahmedabad
₹10,000
27 Mar 2026
27 Mar 2026
27 Mar 2026
22 Apr 2026
27 Mar 2026
Name of Work : Rate contract for Liasoning work(LT & LTMD services) for Power Supply Procurement of New Electric Service Connection,
Extension/Reduction of Load,Shifting From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories for Different Category Electric
Services of Different Offices, Buildings of Ahmedabad Municipal Corporation.
RATE IN Total Amount in
RATE IN Total Amount in
Sr.No. DESCRIPTION UNIT Qty
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of
2.1 (E) in existing pipe
2.2 (a) 2 wire 1.5 sq. mm Mtr. 1 46.00
2.3 (b) 2 wire 2.5 sq. mm Mtr. 1 62.00
2.4 (c) 3 wire 1.5 sq. mm Mtr. 1 62.00
2.5 (d) 3 wire 2.5 sq. mm Mtr. 1 91.00
2.6 (e) 4 wire 1.5 sq. mm Mtr. 1 81.00
2.7 (f) 4 wire 2.5 sq. mm Mtr. 1 114.00
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
3.1 (E) in existing pipe
3.2 (a) 2 wire 4 sq. mm Mtr. 1 86.00
3.3 (b) 2 wire 6 sq. mm Mtr. 1 120.00
3.4 (g) 4 wire 4 sq. mm Mtr. 1 154.00
3.5 (h) 4 wire 6 sq. mm Mtr. 1 238.00
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC insulated conforms to
4 IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control wiring) with required size
of copper lugs, nuts and bolts if required.
4.1 (e) One wire 6.00 sq. mm Mtr. 1 56.00
4.2 (f) One wire 10.00 sq. mm Mtr. 1 91.00
4.3 (g) One wire 16.00 sq. mm Mtr. 1 141.00
4.4 (h) One wire 25.00 sq. mm Mtr. 1 234.00
4.5 (i) One wire 35.00 sq. mm Mtr. 1 298.00
4.6 (j) One wire 50.00 sq. mm Mtr. 1 466.00
4.7 (k) One wire 70.00 sq. mm Mtr. 1 663.00
4.8 (l) One wire 95.00 sq. mm Mtr. 1 910.00
4.9 (m) One wire 120.00 sq. mm Mtr. 1 1167.00
4.1 (n) One wire 150.00 sq. mm Mtr. 1 1447.00
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to
A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply
c/s. with all internal connections, spreader tinned copper & complete erected in
existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea. 1 6112.00
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A.
with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper & complete erected in existing
G.M.S. housing.
ICS=100% of ICU only Cat III Ea. 1 7976.00
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating
200A.with variable Thermal & magnetic release suitable to work on A.C.supply
c/s. with all internal connections, spreader tinned copper & complete erected in
existing 16 G.M.S.housing
ICS=100% of ICU only Cat III Ea. 1 16061.00
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. and above at 415 V . having normal current
rating 250A. with variable thermal & magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader tinned copper & complete erected in
existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea. 1 20739.00
Name of Work : Rate contract for Liasoning work(LT & LTMD services) for Power Supply Procurement of New Electric Service Connection,
Extension/Reduction of Load,Shifting From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories for Different Category Electric
Services of Different Offices, Buildings of Ahmedabad Municipal Corporation.
RATE IN Total Amount in
RATE IN Total Amount in
Sr.No. DESCRIPTION UNIT Qty
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 50 KA and above at 415 V having Normal current
rating 400A. with variable Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.
ICS=100% of ICU only Cat III Ea. 1 24979.00
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 50 K.A. and above at 415 V having normal current
10 rating up to 630A. with variable thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing
ICS=100% of ICU only Cat III Ea. 1 27895.00
Providing and erecting Approved make Earth fault Relay (ELR) suitable to mount with
inter connection suitable to following size of moulded case circuit breaker having CT
11 ratio & MCCB rating as following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing..
12 Providing and erecting following additional parts for panel mounting MCCBs
(A)Extended operating rotary handle with pad lock with three position trip,off,on Ea. 1 865.00
suitable for 25A to 250 A panel mounting cat-III
(B)Extended operating rotary handle with pad lock with three position trip,off,on Ea. 1 1298.00
suitable for 400A to 630 A panel mounting cat-III
Providing & erecting additional parts for Air Circuit Breakers as follows:
(H) Shunt Release Type EA1 : 240V AC Ea. 1 2035.00
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark
Cat.III Ea. 1 111.00
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C
15 Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
following capacity
15.1 (A) 6 to 32 Amp. Cat III Ea. 1 297.00
15.2 (B) 40 Amp. Cat.III Ea. 1 327.00
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve)
16 having 10KA breaking capacity & confirms to IS :8828 in existing box having following
16.1 (a) 6 to 32 Amp. Cat.III Ea. 1 590.00
16.2 (b) 40 Amp. Cat.III Ea. 1 662.00
16.3 (c 63 Amp. Cat.III Ea. 1 730.00
Providing and erecting Sheet Steel powder coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
17 DBs should be used of same company of MCB to be used) suitable for
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43)
17.1 (i) Single phase 4way SS Double door (IP-43) Ea. 1 623.00
17.2 (ii) Single phase 6way SS Double door(IP-43) Ea. 1 877.00
17.3 (iii) Single phase 8 way SS Double door(IP-43) Ea. 1 1141.00
17.4 ( iv ) Single phase 12 way SS double door(IP-43) Ea. 1 1478.00
(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)
(b) sheet steel double door
(i) Three phase 4 way SS Double door for single phase outgoing horizontal box Ea. 1 2316.00
(ii) Three phase 6 way SS Double door for single phase outgoing horizontal Ea. 1 2885.00
(iii) Three phase 8 way SS Double door for horizontal single phase outgoing Ea. 1 3379.00
providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
18 operation on single phase 240 V,50Hz. having characteristic of quick action &
tripping with all advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed
Name of Work : Rate contract for Liasoning work(LT & LTMD services) for Power Supply Procurement of New Electric Service Connection,
Extension/Reduction of Load,Shifting From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories for Different Category Electric
Services of Different Offices, Buildings of Ahmedabad Municipal Corporation.
RATE IN Total Amount in
RATE IN Total Amount in
Sr.No. DESCRIPTION UNIT Qty
18.1 (i) 25 Amps.DP Cat. III Ea. 1 1950.00
18.2 (ii) 40 Amps. DP Cat. III Ea. 1 2213.00
18.3 (iii) 63 Amps. DP Cat. III Ea. 1 2628.00
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for
19 operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action &
tripping with all advance feature & do not incorporate any electronic component for
following Max. rating erected as directed.
19.1 (i) 25 Amps.FP Cat. III Ea. 1 2544.00
19.2 (ii) 40Amps. FP Cat. III Ea. 1 2611.00
19.3 (iii) 63Amps. FP Cat. III Ea. 1 3010.00
19.4 (iv) 100Amps. FP Cat. III Ea. 1 4272.00
Providing and erecting metallic vitrified danger notice board as per language Ea. 1 69.00
20 suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as
Providing and erecting metallic vitrified danger notice board as per language Ea. 1 81.00
21 suggested by engineer incharge for HIGH VOLTAGE installation to be erected as per
Providing & erecting Medium Voltage Danger Notice Board sticker as per language Ea 1 26.00
suggested by engineer incharge of standard size as per IS-2551
Providing & erecting High Voltage Danger Notice Board sticker as per language Ea 1 35.00
23 suggested by engineer incharge of standard size-as per IS
Providing and erecting required size HOT deep Galvanised iron strip for earthing of Kg. 1 77.00
24 H.T. , OCB / ACB / Transformer LT panel board, Motors etc. using proper clamp.
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB / Kg. 1 787.00
Transformer, LT panel board, Motors etc. using copper clamp.
26 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. Kg. 1 787.00
27 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg. 1 77.00
Supplying & erecting earth pit of minimum bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to
28 submit test certificate including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil Ea. 1 4546.00
28.1 Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
(b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Ea. 1 5703.00
28.2 Back filling Compound :1 no. Bag of 25 Kg.
Supplying & erecting funnel type earthing having earth plate of following size burred
in specifically prepared earth pit 3 mtr. below ground with 40 kg. charcoal and salt
with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with Funnel with a wire
mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS
3043 with necessary length of double Galvanised Iron / copper earth wire No 6 SWG
bolted with lug to the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long
complete connected to the nearest switch gear with end socket as per direction &
duly tested by earth tester confirming to IS (As per drawing) with following
(A) With 30 x 30 x 0.35 cms: C.I. earth plate E.a. 1 2289.00
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
30 conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench
/ pipe of following size of cables
30.1 (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) Mtr. 1 182.00
30.2 (B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) Mtr. 1 218.00
30.3 (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core) Mtr. 1 282.00
30.4 (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) Mtr. 1 375.00
30.5 (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) Mtr. 1 486.00
30.6 (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Mtr. 1 535.00
30.7 (G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) Mtr. 1 724.00
30.8 (H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) Mtr. 1 896.00
Name of Work : Rate contract for Liasoning work(LT & LTMD services) for Power Supply Procurement of New Electric Service Connection,
Extension/Reduction of Load,Shifting From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories for Different Category Electric
Services of Different Offices, Buildings of Ahmedabad Municipal Corporation.
RATE IN Total Amount in
RATE IN Total Amount in
Sr.No. DESCRIPTION UNIT Qty
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand
31 Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand
32 Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
32.1 (A) 4 core 16 Sq. mm Mtr. 1 150.00
32.2 (B) 4 core 25 Sq. mm Mtr. 1 187.00
32.3 (C) 4 core 35 Sq. mm Mtr. 1 251.00
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
33 conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench
/ pipe at road crossing or floor of following size of cables.
33.1 (A) 3 1/2 core 25 Sq. mm ( 10 Sq. mm 1/2 core) Mtr. 1 1332.00
33.2 (B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) Mtr. 1 1845.00
33.3 (C) 3 1/2 core 50 Sq. mm ( 25 Sq. mm 1/2 core) Mtr. 1 2409.00
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) Mtr. 1 3535.00
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) Mtr. 1 4510.00
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Mtr. 1 6355.00
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid
Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
trench / pipe at road crossing or floor of following size of cables.
34.3 (B) 4 core 6 Sq. mm Mt 1 503.00
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
35 conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench
/ pipe at road crossing or floor of following size of cables.
35.1 (A) 4 core 10 Sq. mm Mtr. 1 667.00
35.2 (B) 4 core 16 Sq. mm Mtr. 1 975.00
35.3 (C) 4 core 25 Sq. mm Mtr. 1 1486.00
Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating Mtr. 1 55.00
36 the fault all over the run and back filling the same and making the surface as normal
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required Mtr. 1 74.00
37 depth for laying any size of cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
Drilling the road without breaking the road surface (Asphalt) for laying of cable for
38 feeding power supply by making up to following size of holes at both ends complete.
38.1 (A) Up to 100 mm bore dia Mtr. 488.00
38.2 (B) Up to 150 mm bore dia Mtr. 610.00
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for laying of cable. below ground
/ road surface for enclosing cable
39.1 (A)50 mm outer dia Mtr. 1 62.00
39.2 (B)63mm outer dia Mtr. 1 73.00
39.3 (C))90 mm outer dia Mtr. 1 95.00
39.4 (D)120 mm outer dia. Mtr. 1 136.00
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for
40 PVC insulated armoured cable complete with out going tails, insulating tape etc for
following size of cables.
40.2 (B) 2 to 4 core 6 Sq. mm Ea. 1 38.00
40.3 (C) 2 to 4 core 10 Sq. mm Ea. 1 38.00
40.4 (D) 2 to 4 core 16 Sq. mm Ea. 1 47.00
40.5 (E) 2 to 4 core 25 Sq. mm Ea. 1 51.00
Providing and, fixing heavy duty flange type brass double compression type
41 cable gland with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of cables.
Name of Work : Rate contract for Liasoning work(LT & LTMD services) for Power Supply Procurement of New Electric Service Connection,
Extension/Reduction of Load,Shifting From T.P.L. & U.G.V.C.L With Supply of related Electric Accessories for Different Category Electric
Services of Different Offices, Buildings of Ahmedabad Municipal Corporation.
RATE IN Total Amount in
RATE IN Total Amount in
Sr.No. DESCRIPTION UNIT Qty
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner.
Solder less crimping type Copper lugs conforming to IS suitable for cable of following
size evenly crimped with high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved manner.
Disconnecting the cable connection and Providing straight joint with PVC mould
using heat shrink /cast resin type epoxy compound Insulating material and making
45 the joint complete using necessary in line connectors, hardener, earth continuity
connection, spacers etc. and reconnecting the same & ensure the joint resistance
within the limits as per IS.
45.1 (A) up to 25 Sq mm Cable Ea. 1 1073.00
45.2 (B) 35 to 95 Sq. mm cable. Ea. 1 1535.00
Providing , erecting , fabricating the M.S. structure as per requirement on site Kg. 1 77.00
incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly painted with one coat of
red oxide with erection on site as per direction of engineer in charge with necessary
grouting, cementing, plastering & finishing complete.
Liasoning work for power supply procurement/to resume the service In case of
47 Service cut due to Electrical Break down, with Site Visit, Test Report Submission,
Meter Connection,fault rectification in T.P.L./U.G.V.C.L. and Also all necessary work
Single site only one service connection Per Service 1 3000.00
Single site more than 1 up to 10 No.of Service Connection Per Service 1 2000.00
Single Site more than 10 No.of Service Connection Per Service 1 1500.00
Note: The Applicable GST will be given separately by AMC.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
VOL- 1 TECHNICAL BID 27.03.2026.pdf
VOL-2 PRICE BID 27.03.2026.pdf
Download all tender documents and submit your bid