Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹39.9 L+₹2.3 L (6.07%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest amount quoted | |
| 3 | L3₹42.2 L+₹4.6 L (12.3%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Other than lowest amount quoted | |
| 4 | L4₹43.4 L+₹5.8 L (15.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest amount quoted | |
| 5 | L5₹44.0 L+₹6.4 L (16.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest amount quoted |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
26 Jan 2019, 6:00 pmClosed
GE (NS) Kochi
Katari Bagh, Naval Base Post Kochi 682004
REPAIR/MAINT OF INTERNAL WIRING, ELECTRICAL FITTINGS AND FIXTURES AT ND SCHOOL, SIGNAL SCHOOL, ASW SCHOOL, NIAT, NIETT, MWC, JOC, SEAMANSHIP SCHOOL, DIVING SCHOOL, DIVING SCHOOL AND OTHER OFFICES OF INS VENDURUTHY AT NAVAL BASE KOCHI
2018_MES_185670_1
GE(NS)/KOCHI/8575
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
INS Vendurthy
Class D
Category b i
8 documents required · 8 mandatory
₹500
Yes
GE (NS) Kochi
₹88,000
Yes
26 Nov 2020
29 Dec 2018
28 Jan 2019
29 Dec 2018
26 Jan 2019
11 Jan 2019
29 Dec 2018 - 11 Jan 2019
Amount
Taking down copper/aluminium point wiring (light,fan,socket or power etc) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good the disturbed surface of wall to match with existing surface complete all as specified.
M & L Point wiring using FRLS PVC insulated and unsheathed cable 1.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC casing and caping of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch one way complete all as specified.
M & L Point wiring using FRLS PVC insulated and unsheathed cable 1.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC casing and caping of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one bell point controlled by one 5 Amps bell push complete all as specified.
M&L point wiring using FRLS PVC insulated and unsheathed cable 1.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC Casing and caping of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 5 pin, 5 Amps switch socket outlet point on same board controlled by one switch one way complete all as specified.
M & L Point wiring using FRLS PVC insulated and unsheathed cable 1.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC Casing and caping of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 5 pin, 5 Amps switch socket outlet point on independent board controlled by one switch one way complete all as specified.
M & L Point wiring using FRLS PVC insulated and unsheathed cable 2.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC Casing and caping of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 2.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 5 pin 15 Amps switch socket outlet point on independent board controlled by one switch one way complete all as specified.
M & L Point wiring using FRLS PVC insulated and unsheathed cable 2.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC conduit of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch one way complete all as specified.
M&L point wiring using FRLS PVC insulated and unsheathed cable 2.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC conduit of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 5 pin, 5 Amps switch socket outlet point on same board controlled by one switch one way complete all as specified.
M&L point wiring using FRLS PVC insulated and unsheathed cable 2.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC conduit of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 5 pin, 5 Amps switch socket outlet point on independent board controlled by one switch one way complete all as specified.
M&L point wiring using FRLS PVC insulated and unsheathed cable 2.5 sqmm copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694, drawn through PVC conduit of suitable size, including suitable size 2mm thick MS sheet pressed terminal box fitted with 3mm thick hylum sheet cover for housing switches and sockets etc including 1.5 sqmm copper conductor single core as earth continuity conductor connected to common earth dolly for one 6 pin, 15 Amps switch socket outlet point on independent board controlled by one switch one way complete all as specified.
S & F Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified.
S & F Switch socket outlet combination 2 in 1, 3 pin 5 Amps flush type complete all as specified.
S & F Switch socket outlet multipurpose 20 and 10 Amps, 2 in 1, 5 pin, flush type complete all as specified.
S & F Switch piano, flush type, single pole, one way, 10 Amps, complete all as specified.
S & F Switch socket outlet combination, multipurpose 20 and 10 Amps, 2 in 1, 5 pin, flush type complete all as specified.
S & F Fan regulator, electronic 100 watt, 250 volts, step type complete all as specified.
S & F in repair Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified.
S & F in repair Switch socket outlet combination 2 in 1, 3 pin 5 Amps flush type complete all as specified.
S & F in repair Switch socket outlet multipurpose 20 and 10 Amps, 2 in 1, 5 pin, flush type complete all as specified.
S & F in repair Switch piano, flush type, single pole, one way, 10 Amps, complete all as specified.
S & F in repair Switch socket outlet combination, multipurpose 20 and 10 Amps, 2 in 1, 5 pin, flush type complete all as specified.
S & F in repair Fan regulator, electronic 100 watt, 250 volts, step type complete all as specified.
S & F Bell push, 6 Amps, single pole complete all as specified.
S & F in repair Bell push, 6 Amps, single pole complete all as specified.
S & F Electric Bell, AC 230 Volts, single pole, complete all as specified.
S & F in repair Fan capacitor 2.5mfd, complete all as specified.
S & F in repair Fan capacitor 4.0mfd, complete all as specified.
S & F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten/angle fittings complete all as specified.
S & F PVC ceiling rose surface bakelite 3 terminals complete all as specified.
S & F in repair modular fan regulator, 2 module, electronic rotary, 0-4 steps, step type100 watt, 240 volts, 50 Hz, hum free, complete all as specified.
S & F in repair modular switch, 6 Amps, 230 volts, one way, complete all as specified.
S & F in repair modular socket, 2 module, 6 Amps, 2/3 pin combined , 230 volts, combined, complete all as specified.
S & F in repair modular socket, 2 module, 6/16 Amps, 2/3 pin combined , 230 volts, combined, complete all as specified.
S & F in repair modular switch, AC 230 volts, 20 Amps, one way complete all as specified.
S & F in repair modular Bell push, 6 Amps, 1 module, complete all as specified.
M & L Sub main wiring with 2 runs of 2.5 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including concealed rigid PVC conduit, medium grade of suitable size and its connected accessories and provision of one run 2.5 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 2.5 sqmm copper conductor cable and one run of PVC conduit shall be measured as one unit length.
M & L Sub main wiring with 2 runs of 4.0 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including rigid PVC conduit, medium grade of suitable size, surface wiring, and its connected accessories and provision of one run 4.0 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 4.0 sqmm copper conductor cable and one run of PVC conduit shall be measured as one unit length.
M & L Sub main wiring with 2 runs of 6.0 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including rigid PVC conduit, medium grade of suitable size and its connected accessories and provision of one run 6.0 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 6.0 sqmm copper conductor cable and one run of PVC conduit shall be measured as one unit length.
M & L Sub main wiring with 4 runs of 10.0 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including concealed rigid PVC conduit, medium grade not less than 32mm dia and its connected accessories and provision of one run 10.0 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Five runs of 6.0 sqmm copper conductor cable and one run of PVC conduit shall be measured as one unit length.
M & L Sub main wiring with 2 runs of 2.5 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including concealed rigid PVC casing & caping, medium grade of suitable size and its connected accessories and provision of one run 2.5 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 2.5 sqmm copper conductor cable and one run of PVC casing & caping shall be measured as one unit length.
M & L Sub main wiring with 2 runs of 4.0 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including concealed rigid PVC casing & caping, medium grade of suitable size and its connected accessories and provision of one run 4.0 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 4.0 sqmm copper conductor cable and one run of PVC casing & caping shall be measured as one unit length.
M & L Sub main wiring with 2 runs of 6.0 sqmm, single core PVC insulated multistranded copper conductor, unsheathed 1100 volt grade including concealed rigid PVC casing & caping, medium grade of suitable size and its connected accessories and provision of one run 6.0 sqmm, single core PVC insulated multi stranded copper conductor unsheathed as earth continuity , connected to earth dolly inclusive of all accessories including taking down old sub main wiring complete all as specified. Note: Three runs of 6.0 sqmm copper conductor cable and one run of PVC casing & caping shall be measured as one unit length.
S & F Vertical type DB, DP, 4 ways, double door, with 200 Amps rated bus bar with MCCB 4 Pole, 125 Amps having breaking capacity 36kA and having IP-43 protection with enclosure including taking down old DB complete all as specified. Note: All blank spaces for MCBs shall be covered with blank plates.
S & F Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified. Note: All blank spaces for MCBs shall be covered with blank plates.
S & F Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified. Note: All blank spaces for MCBs shall be covered with blank plates.
S & F Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified. Note: All blank spaces for MCBs shall be covered with blank plates.
S & F Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified. Note: All blank spaces for MCBs shall be covered with blank plates.
S & F in repair MCB, TPN, 63 Amps, 415 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair MCB, TP, 63 Amps, 415 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair MCB, SPN, 32 Amps, 415 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair MCB, SPN, 63 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair MCB, SP, 6-32 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair MCB, SPN, 6-32 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.
S & F in repair Isolator, 4 Pole, 100 Amps, 240 Volt complete all as specified.
S & F MCCB, 4 Pole, 100 Amps, 415 Volts, thermal magnetic release range, having breaking capacity 36 kA, isolation funtion, roto active double break mechanism, Ics = 100% Icu, in sheet metal enclosure including taking down old MCCB complete all as specified.
S & F MCCB, 4 Pole, 160 Amps, 415 Volts, thermal magnetic release range, having breaking capacity 36 kA, isolation funtion, roto active double break mechanism, Ics = 100% Icu, in sheet metal enclosure including taking down old MCCB complete all as specified.
S & F MCCB, 4 Pole, 200 Amps, 415 Volts, thermal magnetic release range, having breaking capacity 36 kA, isolation funtion, roto active double break mechanism, Ics = 100% Icu, in sheet metal enclosure including taking down old MCCB complete all as specified.
S & F MCCB, 4 Pole, 250 Amps, 415 Volts, thermal magnetic release range, having breaking capacity 36 kA, isolation funtion, roto active double break mechanism, Ics = 100% Icu, in sheet metal enclosure including taking down old MCCB complete all as specified.
S & F 60 wattage LED street light fitting, pressure die cast aluminium alloy for housing (heat sink) for ensure effective thermal management, sturdiness and excellent corrosion resistance, high efficiency long life LED chip with lumen efficiency of >130 Lum/watt with lense and light fitting efficiency of >90 Lum/watt for better uniformity of light distribution, spread (Beam angle along the drive way) -130 degree minimum, throw (Beam angle across the drive way) -85 degree minimum, asymmetrical batwing light distribution, epoxy powder coated grey after phosphochromate treatment, in-built electronic driver with APFC and THD <10%, minimum surge protection of 4.5 KV, having IP-66 compliant of Cat No LHETBXU7PA6J0100 of Havells or Cat No SLE UL 100W IP66 LXN of Surya Roshni or Cat No HPLLEDSL10060E of HPL or equivalant of Bajaj/Philip/Instapower/Luker, fixed on pole including taking down old light fitting complete all as specified.
S & F 90 Watt LED Flood Light having IP-66 protection, pressure die cast aluminium housing, high luminious efficacy and high power LED Cat No SLE FL 60W IP65 RFLOOD of Surya / HPLLEDFL6060P of HPL / BJFL 60W LED of Bajaj including taking down old unserviceable flood light complete all as specified.
S & F Batten for LED tube (Double side connection) prewired including Bi-pin holder, Cat No LHEXBLP5PN1W018 of Havells/ Cat No SLE BT 20 MS of Surya Roshni including 18 Watt LED tube light with very high efficacy Cat No LHLDEFXD5L8R020 of Havells/Cat No SLETL-DS 18PC REFORM of Surya Roshni or equivalent of CG/Philips/Benlo including taking down old unserviceable FTL complete all as specified.
S & F in repair Bipin holdersuitable for T8/T5 FTL fitting comlete all as specified.
S & F 15 Watt LED round shape, recessed mounted downlight for indoor application including taking down old fitting complete all as specified.
S & F 16 Watt LED square shape, recessed mounted, downlight for indoor application including taking down old fitting complete all as specified.
S & F 16 Watt LED round shape, surface mounted downlight for indoor application including taking down old fitting complete all as specified.
S & F Integral LED Aviation Obstruction Light (AOL) comprising of aluminium housing with polycarbonate enclosure including taking down old unserviceable AOL complete all as specified.
S & F 36 Watt LED recessed mounted panel lights (600x600mm size) luminaires, comprising of aluminium housing with polycarbonate enclousure including taking down old light fitting complete all as specified.
S & F in repair Louvers /shutters suitable for 300mm sweep exhaust fan including necessary fixing arrangement complete all as specified.
S & F in repair Louvers /shutters suitable for 350mm sweep exhaust fan including necessary fixing arrangement complete all as specified.
S & F in repair Louvers /shutters suitable for 450mm sweep exhaust fan including necessary fixing arrangement complete all as specified.
M & L Preparing the surfaces of 1200 / 1400mm sweep ceiling fan by cleaning and filling the cavities with filler and applying one coat of synthetic enamel paint with spray gun, marking the MES No complete all as specified.
M & L Preparing the surfaces of 300/350/450mm size exhaust fan by cleaning and filling the cavities with filler and applying one coat of synthetic enamel paint with spray gun, marking the MES No complete all as specified.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair, complete all as specified.
Taking down unserviceable Exhaust fan of 300mm/450mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair, complete all as specified.
M & L Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron strip 32x6mm size as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore light grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion and taking down old earth plate complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S & F 14 Watt LED Mirror Lamp, 240V, surface mounted decorative mirror optic type with engineered plastic body and including tube rod and connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal including taking down old light fitting complete all as specified.
S & F SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S & F TPN earth encolsure with a three pin and earth plug with socket complete with one TPN MCB 63 Amp, 415 Volt including taking down old earth plug complete all as specified.
M & L XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 50 sq.mm 3.5 core including taking down old unserviceable cable complete all as specified.
M & L XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 35 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M & L XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 25 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M & L XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area16 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M & L XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area10 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
Jack electrolinks Private Ltd
ANIE JOHN CONTRACTORS
Jyothis Enterprises
P N Enterprises
Super Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .