| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹23.9 L
EMD Value
₹23,870
Closing Date
1 Aug 2023, 12:00 pmClosed
Superintending Engineer (EWCL)
Type-IV/3, Transmission Staff Colony Dewa Road, Chinhat Lucknow
Construction of 33 KV Line from 220/33 KV S/S Gola to 33/11 KV S/S Sikndrabad, Lakhimpur Kheri
2023_MVVNL_824026_1
11/EWCL/2023-24
Open Tender
Electrical Works
Fixed-rate
90 days
220/33 KV S/s Gola to 33/11 KV S/s Sikndrabad, Lak
As per tender documents
2 documents required · 2 mandatory
₹3,540
A/c No. 0758002100009592, IFSC PUNB0586800
₹23,870
7 Aug 2023
25 Jul 2023
1 Aug 2023
25 Jul 2023
1 Aug 2023
25 Jul 2023
Amount
Safe loading carriage including unloading & proper stacking of following store materials from any Electy.Store of Lucknow Zone to 33/11 KV S/S Sikndrabad, Lakhimpur Kheri site (work site).
ST Pole 11 Mt Long-SP-55
ST Pole 13 Mt Long-SP-70
ST Pole 11 Mt Long-SP-55- For Stud Pole
9 Mt. Long PCC Pole
9 Mt. Long PCC Pole for Stud Pole
V-type cross arm 100x50x6 mm, MS Channel 9.6 Kg./mtr
Polymeric 11 KV Disc Insulator B&S. Type 70 KN.
Disc Fittings Dog/ Racoon 70 KN.
Polymeric 33KV Pin Insulator
M.S. Angle Iron 65x65x6mm, 4300 mm long 2/6/8 no. Bracing, with 4/12/16 clamps (5.8 kg./m)
M.S. Angle Iron 65x65x6, 3200mm long, 5.8 Kg/Mtr. for cable with clamp
Top channel 125X65mm, 3200 mm long (13.10 Kg./m) with clamp
MS. Channel 100X50 mm (9.6 Kg/mtr.) for Cable Stand
MS Angle 75x75x6mm (6.8 KG/mtr) for Cable Stand
GI wire 6 SWG for guarding along the line
GI wire 8 SWG for guarding a cross the line
Guarding Angle 75x75x6mm (3500/2200 mm long)
Earthing complete
Single core PVC Cable 1x400 Sq.mm.
Complete Stay (GI Stay rod 20x1800 mm, Stay 7/8 SWG 10 Kg.)
ACSR Dog Conductor
33 KV XLPE Cable 3x300 sq.mm.
33 KV XLPE 3X300 sq.mmm C/J/Kit (Outdoor)
Cost of ACSR Panther Conductor
Cost of 33 KV Bus Isolator
Cost of Post Insulator
Cost of 33 KV Lightening Arrester
Cost of 33 KV VCB 750MVA
Providing & Laying ,welding of G.I. strip 50x6mm size with Line Isolator structure, Lightening Arrester Structure, VCB Structure, Post Insulator Structure.
Fabrication, erection ,grouting & painting (one coat of red oxide primer and two coats of synthetic enamel aluminum) of 33 KV Line Isolator structure as per RESSPO/ Approved Drawing and its, plinth 45cm above ground level as directed by the Engineer Incharge (All steel sections will be provided by Deptt).
Mounting and installation, including Mechnical & electrical fixing and adjusting of the 33 KV Line Isolator on Isolator structure including proper adjustment ( 33 KV Line Isolator to be provided by Deptt.)
Lightening Arrestor & P.I. Structure : Fabrication of Lightening Arrestor & P.I. Structure 3.5 mtr. in height as per Drg. digging of two no pits of size 1.075x0.9x0.3 mtr. providing stone pad at the bottom of the pit and grouting of two legs of the Structure in CC(cement coarse sand and stone grit of 20mm gauge) of the ratio 1:4:8 in block of 1.075x0.3 mtr. including all civil material, T&P complete in all respect. The work includes dragging, shifting up to 40 Mtr., raising and erecting the two legs with runner on proper alignment and level and plumb. Both plinths of the structure shall be properly finished with smoothing of edges.
Fabrication and erection of cable support made of two pieces of MS channel 100x50mm, 3.0 mtr. long joined to each other by means of 5 no. MS Flat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in block of size 300x300x700mm (1:4:8) complete. This includes providing of required MS Clamp made of MS Flat holding the cable including nuts & bolts and fixing of XLPE cable.
Installation of P.I. & Lightening Arrestors : Assembling, installation & mounting of 3 No.(1set) L.A. & Post insulator on the L.A & P.I. Structure/complete with making earth connections (separate) with GI Strip 50x6mm. The work includes fabrication for fixing if required. (All decentralised materials to be provided by Contractor).
Erection of the following support including cutting, making holes, fixing of all types of accessories digging pits complete in all respect as per RESSPO drawing. All type of clamps nut & bolt, washer to be provided by contractor.
33 KV Single support of ST Pole 11mtr long.with X Arm, Pin insulator & other all accessories
33 KV Single support of ST Pole 13 mtr long.with X Arm, Pin insulator & other all accessories
33 KV Single support of PCC Pole 09 mtr long.with X Arm, Pin insulator & other all accessories
33 KV Double pole structure on S.T. Pole 11mtr long complete with Top Channel,bracing.& other all acessories
33 KV Double pole structure on PCC Pole 09 mtr long complete with Top Channel,bracing.& other all acessories
33 KV Cable Expouser Double pole structure on S.T. Pole 11mtr long complete with Top Channel,bracing.& other all acessories
Tri Pole structure on ST Pole 11mtr long complete with Top Channel,bracing.& other all acessories
Tri Pole structure on PCC Pole 9mtr long complete with Top Channel,bracing.& other all acessories
Four Pole structure on PCC Pole 9mtr long complete with Top Channel,bracing.& other all acessories
Stud Pole structure on ST Pole 11mtr long complete with all acessories
Stud Pole structure on PCC Pole 9mtr long complete with all acessories
Erection/fixing for 33 KV Stay set with stay wire 7/8 SWG and clamp as per RESSPO drawing including binding, clambing, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete blast and etc would be provided by contractor.(Stay Set , Stay wire to be provided by Dept.)
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement ,brick ballast and sand in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Laying and sagging of 3 phase ACSR Dog conductor from Double pole uptogantry at 132 KV substation / 33KV substation including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc. in all respect.
Earthing of STP/PCC supports with Earth Electrode 2.5 mtr. length including excavation of pit and driving M.S. Rod upto proper depth and connecting the earth electrode with the help of 6 SWG G.I. Wire and earthing lugs. RESPO/ RES. drawing.Earthing of each section pole is also to be done. All type of nut & bot would be given by the contractor.
Cradle type Guarding of HT/LT/Telephone line/ road/river crossing etc. by providing GI wire No. 6/8 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support. All type of nut bolt ,clamp to be provied by the contractor.
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete of job.
Single Pole of 13 M S.T.P
Single Pole of 11 M S.T.P
Double Pole of 11 M S.T.P
Cable Expouser Double Pole of 11 M S.T.P
Tri Pole of 11 M S.T.P
Stud Pole of 11 M S.T.P
Providing & Fixing of 33 KV SMC Danger board ( as per GTP)with Clamp & Nut Bolt
Providing & Fixing of 33 KV SMC Number Plate ( as per GTP) with Clamp & Nut Bolt
Providing & Fixing of G.I. Barbed wire (2 Kg./pole)
Providing & Fixing of Stone Pad (300x300x75 mm)
Drilling and Laying of 3x300 Sqmm 33 KV, XLPE insulated U/G Cable in HDPE Pipe size of 150 mm dia (Pipe to be laid by HDD method) single circuit below minimum 1.5 mtr. Depth from ground level.(HDPE.Pipe to be provided by contractor)
Laying of 33 KV, 3x300 Sqmm XLPE Cable (single circuit) by digging method depth minimum 1.2 mtr. Below ground level and 750 mm wide by excavation of earth. The work include supplying of fine sand ,bricks,stone slab ,refilling and ramming of the left out soil and levelling etc.
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole including G.I. pipe of size 6" dia 3 M long and its jumpering complete with clamps, nuts and bolts. (GI Pipe,clamps ,nut bolt etc to be provided by contractor,)
Providing & Fixing of Cable Route Marker
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge. About 5 Km.
Electrical safety Department NOC charges documentation & approval fees etc
Forest NOC charges documentation & approval fees etc
High Pressure Testing
Painting of all Sub Station Structure with one coat of red oxide primer and two coats of aluminum white paint of ISI mark.
Chemical Earthing: Earthing of 33 KV Main Meter Cubical Room and LA Structure by lowaring and boring of Chemical Earthing outside of switchyard and connecting through G.I. Strip 50x6mm with indoor/outdoor equipments with making of earth pit of 300x300 mm & 1 feet deep with Cover. (All the material provided by the contractor)
Providing & Fixing of Feeder Name Plate
Providing & Fixing ACSR Panther Conductor PG Clamp
Providing & Fixing T-Clamp
Providing & Fixing Isolator Clamp
DURGESH CHANDEL
A.A. ENGINEERING CO.
SINLESS ELECRICAL CO. PVT. LTD.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .