Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.9 LAccepted-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC accept | |
| 2 | L2₹70.0 L+₹14.1 L (25.3%)Rejected-AOC BELOW SLAUGHTER HOUSE KRISHNA NAGER SHIMLA | SHIMLA | SHIMLA | HIMACHAL PRADESH | L2 | Rejected-AOC accept | |
| 3 | L3₹72.3 L+₹16.4 L (29.3%)Rejected-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L3 | Rejected-AOC accept | |
| 4 | Not Admitted-Fee/PreQual/Technical DHALIWAL | AMRITSAR | PUNJAB | 143001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹52.2 L
EMD Value
₹84,720
Closing Date
11 Nov 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Remodeling of LIS Duhak Dhaniyara from old source in GP Duhak in Tehsil Thural Distt. Kangra
2021_HPIPH_53224_1
THL-KNG05-729 (10860-10915 dated 05.11.2021)
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
365 days
Remodeling of LIS Duhak Dhaniyara from old source
Please refer Tender documents.
10 documents required · 10 mandatory
₹800
₹84,720
Yes
13 Jul 2022
5 Nov 2021
12 Nov 2021
5 Nov 2021
11 Nov 2021
5 Nov 2021
120 days
Amount
Excavation in foundation trenches etc.( for pipes and pits)up to all depths in all kind of soil such , as pick work, jumper work saturated soil including bailing or pumping out water, blasting soft/hard rock or chiselling soft /hard rock where blasting is prohibited in all leads & lifts including triming & dressing of sides levelling of beds to correct grade including shorting struttering planking timbering and dewatering where ever required stacking usable/unusable material / soil separately and after laying jointing and testing of pipes returning the usable soil in trenches in 15cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated earth as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of a diversion for traffic night signals,fixing caution boards crossing over trenches for access to houses fencing etc. as per direction of Engineer-in-Charge with in all leads and lifts.
Providing , laying, jointing with circumfrential butt welded joints by electrical arc welding 94 % (welding thickness shall be equal to pipe wall thickness) and welding 6 % M.S. flanges at every 100 mtr pipes and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007 (latest with upto date amendments) having wall thickness as specified below and capable of withstanding required test pressure in a random length of 5.5 to 6.5 meters, including manufacturing reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (two inner one outer), where ever required as per the directions of the Enginer-in-charge ( Earth work in trenches and the cost of providing flanges i/c nuts & bolts & gasket will be measured and paid for seperately) and all operations such as cutting, welding, jointing, fabrication of tees i.e. lowering & laying in excavated Trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials ( if damaged during laying jointing operation of pipe) made form the parent tube , shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing , DP test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts. Note:- Negetive Tolerance should not be more than +/- 3%.
1st STAGE MSERW pipe 200mm dia with wall thickness of 4.80mm,( FT-5) outer dia 219.10mm ,and every 100 mtr pipe flanged from RD 0 to 115 = 115 Rmt
2nd stage MSERW pipe 200mm dia with wall thickness of 4.80mm,( FT-17) outer dia 219.10mm ,and every 100 mtr pipe flanged from RD 0 to 450 = 450 Rmt
2nd stage MSERW pipe 200mm dia with wall thickness of 4.80mm,( FT-11) outer dia 219.10mm ,and every 100 mtr pipe flanged from RD 450 to570 = 120 Rmt
Stage-1st SUBMERSIBLE PUMP SETS :- Supply Installation Testing & Commissioning with automation (To be paid separately)(KSB /Kalama/Kirloskar/Johnston/Cromption/Lubi) make conforming to BIS; 8034-1976 latest suitable for lifting Raw water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-2 sets of 15.00 HP each,I, Total Head,33.14 Mtrs,ii,Discharge required from each pump.15.32 lps for each pump=30.64 LPS ( Both will work at a time),iii,No. of pump required 2.00 Nos.
Automation:-Supply, Installation, Testing and commissioning of fully automatic panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 Nos pump of rating 15 HP X2 Sets =30 HP automatically through energy saving variable frequency starter. starter should be capable to handle all the faults like short circuit, over current under current over voltage under voltage dry pump protection .It should get on and off command automatically from PLC and HMI. Monitoring and controlling of pump running and tripping status should be mointored and controlled remotely through IOT enabled device. Access should be given to 3 usres Make: Aarmation Electric Private Limited / MAS/ELLES/Adlec. any addtional item required to make the automation functional will be done by contractor with in quoted cost. All the componets of the quotation shall be of approved make and shall got approved from Circle Office. complete in all respect, complete in all respect upto satisfaction of Engineer-In-Charge.
2nd stage CENTRIFUGAL PUMP SETS:-Supply Installation Testing & Commissioning with automation (To be paid separately) of horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, of recommended make such as Mather and Platt/KSB/Kirlosker as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors ( Conforming to energy efficiency code IE2 or higher ) of standard make such as Kirloskar /BHEL /CG POWER /Siemens /ABB /Marathon and suitable for operation on 415 (+6% ) and ( -10% ) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: including Pump sets (working + standby ), necessary piping for suction, delivery & common header, alongwith electrical control panel with soft starters; as per requirement of pumping machinery; Complete work inclusive of all taxes,transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials and wastage etc. It shall include providing and fixing of C.I/C.S Sluice valves of approved make and appropriate class to resist the design pressure and complete as per Tender Specifications and instruction of Engineer in charge. 2 Sets,20 HP Each (2x 40 HP= 80 HP)i,Total Head,93.66Mtrs.,ii,Discharge required from each pump.15.32lps for each pump=30.64 LPS( Both will work at a time),iii,No. of pump required,2.00 Set
Automation:-Supply, Installation, Testing and commissioning of fully automatic panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 Nos pump of rating 40 HP X2 Sets =80 HP automatically through energy saving variable frequency starter. starter should be capable to handle all the faults like short circuit, over current under current over voltage under voltage dry pump protection .It should get on and off command automatically from PLC and HMI. Monitoring and controlling of pump running and tripping status should be mointored and controlled remotely through IOT enabled device. Access should be given to 3 usres Make: Aarmation Electric Private Limited / MAS/ELLES/Adlec. any addtional item required to make the automation functional will be done by contractor with in quoted cost. All the componets of the quotation shall be of approved make and shall got approved from Circle Office. complete in all respect,complete in all respect upto satisfaction of Engineer-In-Charge.
Excavation in foundation trenches etc.( for pipes and pits) in all kind of soil such , as pick work, jumper work saturated soil including bailing or pumping out water, blasting soft/hard rock or chiselling soft /hard rock where blasting is prohibited in all leads & lifts including timbering & dressing of sides levelling of beds to correct grade including shoring shuttering planking timbering and dewatering where ever required stacking usable/unusable material soil separately and after laying jointing and testing of pipes returning the usable soil in trenches in 15cm layers including consolidating of each deposited layer by ramming & watering & then disposing of all surplus excavated earth as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of a diversion for traffic night signals,fixing caution boards crossing over trenches for access to houses fencing etc. as per direction of Engineer-in-Charge with in all leads and lifts.
Cutting in earth work and disposal of excavated earth up to a lead of 20 meters Chiselling / wedging out of rock where blasting is prohibited soft rock 100 % as per direction and to the entire satisfaction of Engineer-in-Charge
Providing and laying cement concrete 1:4:8(1cement:4 sand:8 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth with in all leads and lifts as per direction of Engineer-in-Charge with in all leads and lifts
Providing form work with steel plated 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain concrete work with in all leads & lift.
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. upto 200mm in thickness as per direction and to the entire satisfaction of the Engineer-in-charge.
Edges of slabs and breaks in floors and walls Under 20 cm. Wide complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Sides and soffits of beams, beam haunchings,cantilivers, bressumers andlintels not exceeding 1 meter in depth in all heights from floor complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Columns, pillars posts and struts Circular or curved in plan complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete work 1:11/2:3 (1 cement: 11/2 sand: 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement for reinforced concrete work in :
Foundation and Plinth as per direction and to the entire satisfaction of Engineer-in-Charge
Walls (any thickness but not less than 0.10 metre thickness) including attached pilasters buttersses, plinth and string courses etc. from top of foundation upto floor two level as per direction and to the entire satisfaction of Engineer-in-Charge
Columns pillars, posts and struts upto floor two level as per direction and to the entire satisfaction of Engineer-in-Charge
Lintels, beams girders bressumers and cantilevers upto floor two level etc.as per direction and to the entire satisfaction of Engineer-in-Charge
Providing , laying, jointing with circumfrential butt welded joints by electrical arc welding (welding thickness shall be equal to pipe wall thickness) and welding M.S. flanges at every 100 mtr pipes and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007, steel grade L-415 & L- 210 (latest with upto date amendments) having wall thickness as specified below and capable of withstanding required test pressure in a random length of 5.5 to 6.5 meters, including manufacturing reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (two inner one outer), where ever required as per the directions of the Enginer-in-charge ( Earth work in trenches and the cost of providing flanges i/c nuts & bolts & gasket will be measured and paid for seperately) and all operations such as cutting, welding, jointing, fabrication of tees i.e. lowering & laying in excavated Trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials ( if damaged during laying jointing operation of pipe) made form the parent tube , shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing , DP test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts. Note:- Negetive Tolerance should not be more than +/- 3%. 200mm dia with wall thickness of 4.80mm) outer dia 219.10mm with FT- 5
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel with in all leads and lifts.
Steel work welded in built up sections, trusses and fremed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint In gretings, framed guards, bars ladders railings brackets and similar works as per direction and to the entire satisfaction of Engineer-in-Charge
Finishing wall with water proofing cement paint or approved brand and manufacture and of required shade on undecorated wall surface two coat to give an even shade after throughly brushing. The surface to removal all dirt, dust and removing of loose material complete upto floor two level Tor steel with in all leads and lifts.
Providing and fixing 250mm dia C.I. double flanged Sluice valve (with hand wheel) as per IS : 780 Class upto 300mm dia (including brass spindle and as per IS: 2906 Class-II for dia more than 300mm complete with bolts, nuts, rubber insertion etc. (The tail pieces if required shall be mesured and paid for seprately)80mm as per direction of Engineer-in-Charge with in all leads and lifts.
Providing and laying cement concrete work 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement for reinforced concrete work in : Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level
P/F Of Chain Pully 15 mitric tonne as per direction of Engineer-in-Charge with in all leads and lifts.
SUNIL KUMAR
RAJE ENGINNERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .