Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3 L
EMD Value
₹3,000
Closing Date
7 Dec 2026, 10:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
The Executive Engineer.,(Electrical), PWD
Electrical Division, Salem-636007
Provision of Geyser and Solar Water Heater Arrangements MBC College Boys Hostel Building at Pennagaram in Dharmapuri District.
2026_PWD_728696_1
10/17/2026-27
Open Tender
Electrical Works
Percentage
30 days
Dharmapuri
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹3,000
20 Nov 2026
20 Nov 2026
7 Dec 2026
20 Nov 2026
7 Dec 2026
20 Nov 2026
180 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,erection,testing, commissioning and handling over of 500 LPD Solar Water Heater with the following components. A) TANK & EVACUATED TUBE COLLECTOR HEATER 500 LPD-1 set. The tanks are generally made of Inner Tank and outer cladding cover. The inner tank made of SS 304 grade/MS or any other materials with anticorrosive coating.For SS inner tank thickness may be min. 1mm when using argon arc or metal inert gas for welding & 1.6mm when using other type of welding.For MS and other materials,it will be above 1.5 mm . No leakage under any kind of negative and positive pressure of water shall be ensured.Minimum 50mm thickness of CFC free PUF having density of 28-32 kg/cu.m in case of higher density insulations, the thickness may reduce propotionately.Aluminium /FRP or GI powder coated outer cladding mat be used. M.S may also be used with special anti-corresive protective coatings: Thickness of sheets will be strong enough to avoid any deformations of the cladding.Size of the tank OD 240mm and length is 800mm. Tube length 1800mm, outer tube diameter 58mm, Inner tube 47mm, Glass Thickness 1.6mm, Tranmission Coefficient 89. Reflection Coefficient 8.4%,Absorbtion coefficient 86%, vaccum pressure 5.0 pa, Average Heat loss coefficient 0.85W/m2C minimum 18 nos of ETC Tubes to be used. (B) MOUNTING STRUCTURE OF STORAGE TANK: Supply, Installation & commisioning in position of the hot water storage tank will be mounted on fixed metallic strutures of adequate strength and appropiate design, which can withstand and high wind velocities upto 150 km per hour. The Support structure will be MS powder coated.The Mounting structure should have the following features: i) The Support structure shall be mild steel, powder coating(120 micron) iron for holding the stroage tank. The size of angle iron should not be less than 35x35x5 mm, ii) Each Structure shall be the so fabricated as to be placed on roof on its legs. It will withstand servre cyclone or storm with the speed of 150m/Hr iii)All nuts and bolts should be made of very good quantity and should be correction resistant, iv) The structure should be designed to allow easy replacement of Tank (C) MOUNTING STRUCTURE FOR EVACUATED TUBE COLLECTE HEADER-1 set structure shoul be designed to allow easy replacement of any module. Supply, Installation & commissioning in position of Evacuated Tube Collector will be mounted on fixed metallic strutures of adequate strength and appropriate design, which can withsatand load of tubes and high wind velocities up to 150 km per hour. The support structure used will be MS powder Coated.The " Mounting Structure" Should have the following features: i) The support structure shall be mild steel, powder coating (120 microns) iron for holding the Evacuated tube collector. The size of angle iron should not les than 25x25x25 mm, ii) Each structure shall be so fabricated as to be placed on roof on its legs. It will withstand severe cyclone or strom with the speed of 150Km/Hr, iii) All nuts and bolts should be made of very good quality and should be corrosion resistant, iv) The Structure Should be designed to easy replacement of any ETC Tube. | 2 | Each | 69,200 | ₹1,38,400 |
| 2 | Supply and clamping of 1 inch UPVC pipe line with suitable bends/Tee connectors , Clamps,Fasteners etc for hot water line. | 91 | Metre | 500 | ₹45,500 |
| 3 | Supply and clamping of 1 inch CPVC pipe line with suitable bends/Tee connectors , Clamps,Fasteners etc for hot water line. | 91 | Metre | 500 | ₹45,500 |
| 4 | Supply and clamping of 1 inch CPVC ball value with suitable bends/Tee connectors , Clamps,Fasteners CPVC Union connector for hot water outlet. | 4 | Each | 980 | ₹3,920 |
| 5 | Supply and fixing of 1/2 inch BSP Nickel coated Brass Hot water tap for hot water outlet with necessary CPVC reducers. | 2 | Each | 690 | ₹1,380 |
| 6 | Supply and fixing of 1 no 6/16A two module socket, 1 no 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. Higher End | 1 | Each | 853 | ₹853 |
| 7 | Supply and fixing of 1500 W automatic electric water heater of 35 litres capacity suitable for 230V 50c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection. | 1 | Each | 9,089 | ₹9,089 |
| 8 | Supply and Run of 2 of 4 sq.mm PVC insulated SC unsheathed FRLS copper condutor of 1100 V grade in Suitable PVC rigid pipe on eall and ceiling with continuous eart wire connection of 4 sq.mm copper wire with painting of suitable colour. | 29 | Metre | 255 | ₹7,395 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
eTenderconditionpennagaram.pdf
Tender Documents • 0.57 MB
BOQ_874508.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .