Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC aoc | |
| 2 | L2₹14.7 L+₹1.1 L (7.82%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹15.3 L+₹1.7 L (12.3%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹15.5 L+₹1.9 L (14.1%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹17.1 L+₹3.5 L (25.8%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | COCHIN | ERNAKULAM | KERALA | 682010 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹19.3 L
EMD Value
₹38,600
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R AND D KOCHI
AGE I R AND D KOCHI, THRIKKAKARA, KOCHI 682021
PROVISION OF THREE PHASE POWER SUPPLY FOR WINCH TESTING FACILITY AT ASSP BUILDING AND PRESSURE TESTING FACILITY AT NPOL, KOCHI
2022_MES_525626_2
8107E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KAKKANAD
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
AGE I R AND D KOCHI
₹38,600
Yes
17 May 2025
30 Jun 2022
21 Jul 2022
30 Jun 2022
19 Jul 2022
2 Jul 2022
Amount
Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.0 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 375 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. (LT Panel No- 01 at Work Shop).
Incoming:
(a) MCCB 250 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indicating Lamp Red/Yellow/Blue - 03 Nos (c) SP MCB 6A -03 Nos (d) MFM Metr with CT- 01 No
Outgoings.
(a) 160 Amp 4P MCCB 25 KA Ics=100% of Icu with spreader & rom -02 Nos. (b) 63 A 4P MCCB 25 KA Ics=100% of Icu with spreader & rom -01 No. (c) 16 Amp 4 MCCB 16 KA, Ics=100% of Icu with spreader & rom -01 No.
supply ,install ,test and commissioning of Outdoor type double door LT Feeder pillar box .made out of 3.0 mm thick CRCA sheet Outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front and rear opening suitable locking arrangement having Copper bus bar of 600 Amps capacity for RYB and half for neutral and insulated with insulators, including cnnecting and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level with comprising of the followings. Note: Cost including necessary internal wiring to CT 's and Meters. (LT panel No 02 at ASSP bldg).
Incoming:
(a) MCCB 400 Amp,TPN, 36 KA, Ics =100% of Icu with Spreader & rom-01 No (b) Indicating Lamp Red/Yellow/Blue - 03 Nos (c) SP MCB 6A -03 Nos (d) MFM Metr with CT- 01 No
Outgoings:
(a) MCCB 160 Amp, 4 Pole, 25 KA , Ics-100% of Icu with spreader & rom -03 No (b) MCCB 125 Amp, 4 Pole, 25 KA , Ics-100%of Icu with spreader & rom -01 No (c) 32 Amp 4 MCCB 16 KA, Ics=100% of Icu with spreader & rom -01 No.
M&L for extending the existing LT panel board at LT substation above Central AC Plant of Main Lab with 2.0 mm thick CRCA sheet Factory made Indoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved, with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 480 Amps with necessary supporting insulators so as to match with the existing LT panel board/ Distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel /bus bar including necessary supporting frame /channel fix through existing cable trench from ground with comprising of the followings:-
(a) MCCB 320 Amp , 4Pole, 36KA, Ics-100% of Icu with spreader and rom-01 No (b) Provision for outgoing cable of size up to 150 sq mm from the extended portion of LT distribution panel
M&L for extending the existing LT panel board at T complex LT substation with 2.0 mm thick CRCA sheet Factory made In door type totally enclosed weather dust and vermin proof as per IS , CPRI Approved, with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 750 Amps with necessary supporting insulators so as to match with the existing LT panle board/Distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel /bus bar including necessary supporting frame /channel fix through existing cable trench from ground with comprising of the followings:-
(a) MCCB 500 Amps, 4 Pole, 36 kA, Ics =100% of Icu with spreader and rom-1 No.
(b) Provision for outgoing cable of size up to 300 sq mm from the extended portion of LT distribution panel
Note for SI Item No 01, 02, 03 and 04 :(i) Contractor has to submit the drawing for LT panel board before commencement of work and get it approved from Accepting Officer
ii) Contractor has to take the shutdown from the MRS 11KV Substation at technical area with prior permission for extending of main LT panel at sub stations
ii) Contractor shall be cleaned the existing LT panel before making connections from existing LT panel to new LT panel after shut down
S&F Industrial surface/wall mounting socket 125 Amp 4 pole with straight plug 125 Amp 4 Pole + E400 V IP 67 protection and sockets enclosure as PLEXO3 cabinet IP 65 protection 8 MOD fixed on wall with including incoming MCB TPN 125 Amp FP all as specified and as directed Make: MDS Legrand /L&T/Siemens.
M&L for XLPE insulated, armoured , heavy duty electric cable with aluminium conductor , 1100 Volts grade , in trenches/fixed on wall of following cross-sectional area Note (i) Rate include the cost of lug of proper size and cable gland (ii) Necessary Excavation, PCC cover and sand cushioning shall be measured &paid separately
(a) Cable of size 150 sq mm 3.5 core
(b) Cable of size 70 sq mm 3.5 core
(c) Cable of size 35 sq mm 3.5 core
Excavation in trenches not exceeding 1.5 m deep and 1.5 m width as in soft/loose soil complete all as specified
Returning filling incl leveling watering and well ramming in layer not exceeding 25cm thick complete all as specified& directed by Engineer-in-Charge.
Removal of surface soil to a distance n.exc 50m and deposited where directed at a level n.exc1.5 m above the starting point complete all as directed.
S & L for Sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable (Note: Punned thickness shall be taken for measurement )
Supply and lay unreinforced precast cement concrete cable cover for protection of underground cable in trenches class LV flat size 250 x 150 x 40 mm.
M&L Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of 25x 4mm by means of bolts, nuts, washers etc., GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C1 earth chamber with 40mm x 40mm x 6mm MS angle iron frame, 40mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc., with plastering 15mm thick in CM (1:6) internally and upto 150mm below GL externally, PGI funnel with wire mesh, complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as specified and as directed.
NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre.
Supply and lay in trenches /fixed on wall GI tubing light grade with necessary fittings such as bend , tee, elbow etc complete for the following sizes
80 mm bore
50 mm bore
M&L for PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in mass concrete, filling , etc. complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping including use and waste of form work etc. complete all as specified and directed.
Material and Labour for cross arms. Bracings, supports, clamps and back plates fabricated from structural steel sections including nuts ,bolts, washers, welding bending cold or hot ,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat , one under aluminium coat and one aluminium finishing coat of paint complete all as specified for supporting frame for fixing the single phase enclosure and as directed by Engineer -in-Charge.
ELSOL ENGINEERS
M/s.Rejoy Constructions
WELTRONENGINEERINGSERVICES
ZOOM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .