Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹12,700
Closing Date
16 Dec 2020, 11:30 amClosed
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Repair/renovation of APFC panels and allied works at Shastri Nagar BPS Re-invited
2020_DJB_197401_16
NIT NO. 16 (2020-2021)
Open Tender
Miscellaneous Services
Item Wise
60 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹12,700
23 Dec 2020
10 Dec 2020
16 Dec 2020
10 Dec 2020
16 Dec 2020
10 Dec 2020
S/o APFC Relay, 12 Stage Make:- L&T / Schneider / Epcos / Trinity / DJB Approved
S/o Capacitor, Cylindrical type, 25 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 20 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 15 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 10 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 05 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 03 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o Capacitor, Cylindrical type, 02 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o MCCB 300 Amp TP 50 KA Make:- L&T / Schneider / C&S / DJB Approved
S/o MCB 63 Amp TP Make:- L&T / Schneider / C&S / DJB Approved
S/o MCB 10-32 Amp Make:- L&T / Schneider / C&S / DJB Approved
S/o Contactor Capacitor Duty TP 30 KVAR Make:- L&T / Schneider / C&S / DJB Approved
S/o Contactor Capacitor Duty TP 25 KVAR Make:- L&T / Schneider / C&S / ABB DJB Approved
S/o Contactor Capacitor Duty TP 10 KVAR Make:- L&T / Schneider / C&S / ABB DJB Approved
S/o Contactor Capacitor Duty TP 5 KVAR Make:- L&T / Schneider / C&S / ABB DJB Approved
S/o Contact Block 1 NO 1 NC Make:- L&T / Schneider / C&S / ABB DJB Approved
S/o Indicating Lights Make:- L&T / Schneider / C&S / ABB DJB Approved
S/o Push Buttons Make:- L&T / Schneider / C&S / ABB DJB Approved
Dismantling of all the defected material / Switchgears from each of the two existing APFC Panels after disconnecting all of their connections etc.
Installation /Fixing of 300 A MCCBs in incomer chamber in the both panels and making their required connections including replacing any defected or addition of Bus Bars with modification of doors etc with making complete incoming connections as required.
Installation /Fixing of Capacitors in the both panels and making their required connections including replacing any defected wire / cable with complete incoming /outgoing connections as required.
Installation/ Fixing of MCBs in the both panels along with making complete incoming connections with Bus Bars as per requirement including replacing any defected wire / cable / connections as required.
Installation/ Fixing of contactors in the both panels along with making complete connections with their incoming MCB as per requirement including replacing any defected wire / cable / bus bar with complete incoming /outgoing connections as required.
Installation of APFC Relay in both panels, making required configuration and making its required wiring connections by existing or by replacing any defected wiring for switching the contactors with complete connections as per requirement.
Reconditioning of the metering / indicating system of both panels for replacing any defected material along with supply of required material along with their complete wiring with thimbling etc. as per requirement.
Complete reconditioning of the both Panels including tightening Incoming cable connections, tightening of bus bar joints, replacing of the defected door locks etc. and all other works required for energizing the Panels
S/o Capacitor, Cylindrical type, 25 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o 63 Amp MCB in TP Make:- L&T /Schneider / C&S /ABB DJB Approved
Fabrication / Providing of cubicle box each suitable for housing of two 25 KVAR Capacitors and two 63 a MCBs with fixing of these material in the boxes with complete interconnections of the capacitors and the MCBs as per requirement.
Fixing of the above Cubicle Boxes for each motor / pumps with mounting provisions and with required consumables and materials as per site requirement
Making the required connections of the capacitors with pump / motors by providing copper cables and carrying out all the works required for parallel switching on of the capacitors along with of motors / pumps.
S/o Capacitor, Cylindrical type, 10 KVAR, 440 V Make:- L&T / Schneider / Epcos / ABB DJB Approved
S/o 32 Amp MCB in TP Make:- L&T /Schneider / C&S /ABB DJB Approved
Fixing of the two Nos.10 KVAR rating Capacitors and two Nos. 32 A rating MCB in panels for each of the Two Transformers along with complete wiring connections by providing copper cables / wires with required consumables and materials as per site requirement.
Testing and commissioning of the both APFC Panels including testing for auto manual capacitor switching and relay setting, functioning and other capacitors as per site requirement.
HYDROCON ENGINEERS
Gupta Brothers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .