Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR | NAGPUR | MAHARASHTRA | 440036 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹14.9 L+₹39,550 (2.73%)Rejected-Finance 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹17.9 L+₹3.4 L (23.1%)Rejected-Finance TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹18.9 L+₹4.4 L (30.4%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹19.3 L+₹4.8 L (32.9%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | Tarachand gurudutt L2 | SHYAM AND SONS ENTERPRISES L5 | Bedi Refrigeration Works L4 | GLOBAL POWER SYSTEMS L1 | VATANUCOOL ENGINEERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Inverter Type System
Supply of 100% Inverter units complete with Inverter compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring andrefrigerant piping housed in compact housing duly powder coated, Conformal Coating onPCB, Hydrophilic Blue Fins of following capacities. Eco Friendly
Refrigerant (R-410a)
Cap: 4.0TR Verticool / Tower Unit / Hot and cold Type Outdoor + Indoor units with all accessories Complete all as directed by Engr - in - charge. | 6 | Nos | 2,11,000 ₹12,66,000 | 2,67,500 ₹16,05,000 | 1,95,800 ₹11,74,800 | 1,86,500 ₹11,19,000 Lowest | 2,00,000 ₹12,00,000 |
| 2.00 | Inverter Type System
Installation, testing and commissioning of Outdoor + Indoor units equipped with highly efficient compressor(s), air-cooled condenser, charging of refrigerant (R-410) and lubricating oil delivering the following actual capacities as follows:
Cap: 4.0 TR Verticool / Tower Unit / Hot and cold Type with all accessories Complete all as directed by Engr - in - charge | 6 | Nos | 8,500 ₹51,000 | 25,000 ₹1,50,000 | 30,000 ₹1,80,000 | 7,450 ₹44,700 Lowest | 25,000 ₹1,50,000 |
| 3.00Refrigerant Piping: Supply Installation Testing & Commissioning of High Pressure Interconnecting Refrigerant Pipe work for AC System with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications, all piping inside the room shall be properly supported on GI hangers, lying of GI cable tray (100mm X 50mm X 1.6mm) and PVC sleeves shall be provided wherever pipe is crossing the wall. Ultra-high Pure Nitrogen is to be used while making breezing joints, Breezing Rods Shall be HARRIS (imported),With all accessories Complete all as directed by Engr - in - charge | ||||||||
| 3.10 | 19.1 mm OD, 19 mm thick insulation | 60 | RMT | 1,350 ₹81,000 | 1,200 ₹72,000 Lowest | 5,500 ₹3,30,000 | 2,200 ₹1,32,000 | 3,950 ₹2,37,000 |
| 3.20 | 9.5 mm OD, 13 mm thick insulation | 60 | RMT | 1,300 ₹78,000 | 1,100 ₹66,000 Lowest | 3,100 ₹1,86,000 | 1,500 ₹90,000 | 2,880 ₹1,72,800 |
| 4.00 | Drain Piping Rigid PVC piping complete with fittings, with proper U-Trap and supports and duly insulated with 6 mm thick closed cell nitrile rubber insulation, assuming 08 Meter Each.
(i) 25 mm dia. | 70 | RMT | 100 ₹7,000 Lowest | 300 ₹21,000 | 200 ₹14,000 | 500 ₹35,000 | 252.58 ₹17,680.6 |
| 5.00 | Control wiring
Supply, Laying and testing of following size of control cum transmission wiring to be laid in PVC conduit pipe between indoor & outdoor units.
(i) 2C × .75 Sqmm Copper wire. | 65 | RMT | 100 ₹6,500 | 200 ₹13,000 | 90 ₹5,850 Lowest | 450 ₹29,250 | 124.22 ₹8,074.4 |
| 6.00NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. | ||||||||
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
12 Mar 2026, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
PROVN OF 06 TOWER AIR CONDITIONERS IN ASSEMBLY HALL AT NHO, DEHRADUN
2026_MES_753382_1
GE/CLT/ Of 20256-26
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat b(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹42,000
Yes
9 Jun 2026
19 Feb 2026
19 Mar 2026
20 Feb 2026
12 Mar 2026
5 Mar 2026
Inverter Type System Supply of 100% Inverter units complete with Inverter compressor fitted with Conentrated winding, air cooled condenser with low noise fan having interconnected control wiring andrefrigerant piping housed in compact housing duly powder coated, Conformal Coating onPCB, Hydrophilic Blue Fins of following capacities. Eco Friendly Refrigerant (R-410a) Cap: 4.0TR Verticool / Tower Unit / Hot and cold Type Outdoor + Indoor units with all accessories Complete all as directed by Engr - in - charge.
Inverter Type System Installation, testing and commissioning of Outdoor + Indoor units equipped with highly efficient compressor(s), air-cooled condenser, charging of refrigerant (R-410) and lubricating oil delivering the following actual capacities as follows: Cap: 4.0 TR Verticool / Tower Unit / Hot and cold Type with all accessories Complete all as directed by Engr - in - charge
Refrigerant Piping: Supply Installation Testing & Commissioning of High Pressure Interconnecting Refrigerant Pipe work for AC System with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between indoor & outdoor units as per specifications, all piping inside the room shall be properly supported on GI hangers, lying of GI cable tray (100mm X 50mm X 1.6mm) and PVC sleeves shall be provided wherever pipe is crossing the wall. Ultra-high Pure Nitrogen is to be used while making breezing joints, Breezing Rods Shall be HARRIS (imported),With all accessories Complete all as directed by Engr - in - charge
19.1 mm OD, 19 mm thick insulation
9.5 mm OD, 13 mm thick insulation
Drain Piping Rigid PVC piping complete with fittings, with proper U-Trap and supports and duly insulated with 6 mm thick closed cell nitrile rubber insulation, assuming 08 Meter Each. (i) 25 mm dia.
Control wiring Supply, Laying and testing of following size of control cum transmission wiring to be laid in PVC conduit pipe between indoor & outdoor units. (i) 2C × .75 Sqmm Copper wire.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tenderdocs8318.pdf
Tender Documents • 0.89 MB
BOQ_843832.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .