I. No. Qty Items Unit Rate Per Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra Breacker
including stacking of servicable materials and
disposal of unservicable materials with all lead
and lift.Removal Of Existing Building
a 40 Foundation and Super Structure If Any. 1047.38 Cu.M.
Demolition of Brick work and stone masonry
including stacking of serviceable materials and
disposal of unserviceable materials with all lead
and lift.(ii) In Cement Mortar.Removal Of
Existing Building Foundation and Super
b 60 Structure If Any. 544.95 Cu.M.
Dismentaling of sheet roofing including ridges,
Hips, Valleys, Gutters etc. stacking of
serviceable materials and disposal of
c unserviceable materials with all lead and lift.
i 5 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including distempering
d 2000 and stacking the materials with all lead and lift. 3.63 Kg.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
architraves, hold fasts and other attachment
etc. complete and stacking them with in all lead
e 2 and lift. (i)Notexceeding 3 Sq.M. in area. 185.85 Each
Removing & Scrapping of Old deteriorated
Plaster of any thickness from Masonary /
R.C.C. member including stacking of
serviceable material & disposal of un
f 250 serviceable from site of work with all lead & lift. 19.38 Sq.M.
Dismentaling any type tiled of stone floors laid
in mortar including stacking of serviceable
materilas and disposal of unserviceable
g 50 materials with all lead and lift. 47.25 Sq.M.
Excavation for foundation including sorting out
stacking of useful material & disposing of
excavated stuff upto 50 mt. lead. Loose & Soft
2 soil.Excexuted With Mechanical Effort
a 1349 up to 1.5 mt. depth 115.92 Cu.M.
b 1147 1.5 to 3.0 mt. depth. 128.52 Cu.M.
c 764 3.0 to 5.0 mt. depth 141.11 Cu.M.
Add extra for Disposing off the excavated stuff
d 2000 of above items for lead of (A) 50 m to 100 m 17.28 Cu.M.
Add extra for Disposing off the excavated stuff
e 2000 of above items for lead of (B) 100 m to 200 m 34.56 Cu.M.
Providing and installing cast in situ single under
reamed piles of specified diameter and length
below pile cap, excluding the cost of Concrete,
steel reinforcement but including the cost of
boring with bentonite solution and the length of
the pile to be embedded in pile cap etc. all
complete. (Length of pile for payment shall be
f measured upto to the bottom of pile cap) :
i 10 400 mm dia. Piles 638.83 Rmt.
ii 10 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for providing
additional bulbs in under reamed piles, under
specified diameter excluding the cost of
Concrete, steel reinforcement (only the nos. of
g extra bulbs are to be paid).
t 1 400 mm dia. Piles 813.05 Each
ii 1 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete 1:5:10 (1
cement : 5 course sand : 10 hand broken
aggregates 40 mm nominal size) and curing
complete, excluding cost of form work in
3a 1 foundation & Plinth. 2492.52 Cu.M.
Provdg. & laying cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 hand broken stone
aggregates 40 mm nominal size) and curing
3b complete excluding cost of form work in
353 (A) Foundation and plinth 2976.00 Cu.M.
Supplying of graded hand brocken stone size of
3c 128 90 mm to 127 mm at site (Rubble or Spoul) 609.82 Cu.M.
Labour charges for spreading the spouls 90 mm
to 127 mm thick layer good earth filling in voids
correcting the grade & camber comp. with
rolling, watering, incl. preparing thesurface by
brushing for removing all loose or dirts
3d 554 ect.comp. 16.07 Sq.mt.
Provdg. & laying cement concrete 1:4:8 (1
cement : 4 coarse sand : 8 hand broken stone
aggregates 40 mm nominal size) and curing
complete excluding cost of form work in
4 5 foundation& plinth. 2653.67 Cu.M.
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of foundations
etc. in layers not exceeding 20 cm. in depth
consolidation each deposited layer by ramming
5 2850 and watering. 129.10 Cu.M.
Conveyance charges of earth lime, murrum,
building rubbish, manure, garbage, sludge,
excavated rock, fly ash, aggregate of any kind
a 100 Conveyance charges 0 km to 1 km 46.63 Cmt
b 100 Conveyance charges 0 km to 2 km 60.69 Cmt
c 6000 Conveyance charges 0 km to 5 km 100.44 Cmt
Extra For Lead on Above Item Above 5 km &
d 6000 upto 6 km 9.26 Cmt
Extra For Lead on Above Item Above 6 km &
e 6000 upto 7 km 9.26 Cmt
Extra For Lead on Above Item Above 7 km &
f 6000 upto 8 km 9.26 Cmt
Extra For Lead on Above Item Above 8 km &
g 6000 upto 9 km 9.26 Cmt
h 6000 Extra For Lead on Above Item Above 9 km 9.26 Cmt
Filling in plinth with sand under floors including
watering, ramming, consolidating, compacting
7a 15 and dressing etc. completed. 455.63 Cu.M.
Filling in foundation and plinth with murrum or
selected soil in layers of 20 cm. thickness
including watering, ramming and consolidating
7b 495 etc. Complete. 286.20 Cmt
Brick work using common burnt clay building
bricks having crushing strength not less than
35 kg/Sq. cm. in cement mortar 1:6 (1 cement :
8 6 fine sand) conventional brick
a 78 (a) in foundation & Plinth 3981.21 Cu.M.
b 225 Super structure Upto Floor Two Level 4253.46 Cu.M.
c 438 Super structure Above Floor Two Level 4293.55 Cu.M.
I.Half brick masonry in common burnt clay
building bricks having crushing strength note
less than 35 Kg/Sq. Cm. in cement mortar 1:4
(1 cement : 4 coarse sand) using conventional
9 brick in Super structure upto floor Four level
a 470 All Floor Level 646.70 Sq.M.
Providing and laying controlled cement concrete
of M-25 Grade and curing complete, Excluding
the cost of form work, Scaffolding, cost of
reinforcement for reinforced concrete work For
10.1 any Height up to any FloorLevel.
a 31 Foundations,Raft,Footings,Mass concrete 4238.04 Cu.M.
b1 2 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket, Stair Case &
Landing, Coping ,Slab, balcony, weather shed,
c1 15 loft , any cantilever etc All Floor 4496.07 Cu.M.
d1 12 Columns,Pillars, posts and struts at All Floor 4593.91 Cu.M.
Providing and laying controlled cement concrete
of M-20 Grade and curing complete, Excluding
the cost of form work, Scaffolding, cost of
reinforcement for reinforced concrete work For
10.2 any Height up to Floor Four Level.
a 10 Foundations,Raft,Footings,Mass concrete 3977.88 Cu.M.
Tie Beam , Lintel , Beam- Bracket , Coping
,landing, Slab, balcony, weather shed, loft , any
b1 91 cantilever etc at All Floor 4460.36 Cu.M.
c1 3 Column at All Floor 4558.20 Cu.M.
d1 1 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready Mixed
M250 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to site
of work in transit mixer for all lead having
continuous agitated mixer, manufactured as per
mix design of specified grade for reinforced
cement concrete work including pumping of
R.M.C. from transit mixer to site of laying with
all lead and lift, excluding the cost of centering
shuttering finishing and reinforcement including
cost of admixtures in recommended proportions
as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing
strength and durability as per direction of the
Engineer - in charge. Without Fly Ash (Min
cement level as per latest IS 456 shall be
10.3 1087 maintained) (Cement level 450 kg ) 4853.56 Cu.M.
Providing and laying in position Ready Mixed
M200 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to site
of work in transit mixer for all lead having
continuous agitated mixer, manufactured as per
mix design of specified grade for reinforced
cement concrete work including pumping of
R.M.C. from transit mixer to site of laying with
all lead and lift, excluding the cost of centering
shuttering finishing and reinforcement including
cost of admixtures in recommended proportions
as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing
strength and durability as per direction of the
Engineer - in charge. Without Fly Ash (Min
cement level as per latest IS 456 shall be
10.4 10 maintained) (Cement level 400 kg ) 4793.10 Cu.M.
Drilling suitable holes in reinforced or plain
cement concrete with power driven drill
machine to a minimum depth of 80mm upto
250mm in RCC beams, lintels, columns and
slabs to introduce steel bars for
sunshades/balconies including fixing the steel
bars in position using Hilti Chemical HY200-R
but excluding the cost of reinforcement, all
complete as per direction of Engineer-In-
a 300 8 mm Dia in 80 mm Deep & 12 mm Dia Drilling 183.52 Each
10 mm Dia in 100 mm Deep & 14 mm Dia
b 750 Drilling 263.66 Each
12 mm Dia in 120 mm Deep & 16 mm Dia
c 750 Drilling 343.80 Each
16 mm Dia in 160 mm Deep & 20 mm Dia
d 90 Drilling 608.63 Each
20 mm Dia in 200 mm Deep & 25 mm Dia
e 35 Drilling 1024.44 Each
25 mm Dia in 250 mm Deep & 32 mm Dia
f 20 Drilling 1938.54 Each
Providing and laying controlled cement concrete
1:2:4( 1cement : 2 coarse sand : 4 Graded
stone aggregate 20 mm nominal size ) and
curing complete, Excluding the cost of form
work and reinforcement for reinforced concrete
Foundations, footings, base of columns,grade
a 4 slab and mass concrete. 3923.53 Cu.M.
slab, landing shelves, Balconies, lintels, beams,
b 1 girders, and cantilever, up to aany floor level. 4012.47 Cu.M.
P/A Trimix with dewatering machine and floater
machine on constructed R.C.C. work incl. cost
c 1035 of machine and labour etc. comp. as directed. 54.00 Sqmtr
Making 15 mm Groove in R.C.C work on road
and filling it with poly sulfied selant and finished
it good incl. all labour charges etc. comp. as
d 450 directed 30.00 Rmt
Providing and laying and fixing 25 mm thick
expansion joint by hydrocell semi rigid UV
resistance with high performance laminated
closed cell polythene foam joint filler in sheet
e 11 foam as directed, etc. complete. 738.13 Sqmt
Providing form work in ordinary timber planking
so as to give a rough finish including centering,
shuttering, strutting and propping etc. height of
propping and centering below supporting floor
to celling not exceeding 4 M & removal of the
same for in situ reinforced or plain concrete
(A) Foundation, footings, bases of columns etc.
a 616 and mass concrete. 171.68 Smt
(B) Flat surface such as soffits of slabs, landing
b 1974 and the like 252.00 Smt
(C) Vertical surfaces such as walls (any
c 975 thickness) partitions. 229.95 Smt
(D) Columns, pillars, posts & struts.
d 1368 (1) Square, rectangular, polygonal in plan 297.68 Smt
e 20 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam, haunchings
cantilevers, girders, bressumers, Coping and
f 3026 lintels not exceeding 1 M in depth. 192.15 Smt
(2) Sides and soffits of beam, haunchings
cantilevers, girders, bressumers and lintels
g 10 exceeding 1 M in depth. 259.88 Smt
(L) chullah hoops, weather sheds, chhajas,
h 190 carbels etc including edges. 155.78 Smt
(M) Staircase with-sloping or stepped soffits
i 180 incl. risers & strings excluding landing. 242.55 Smt
Extra for additional height of propping and
centering where the height of propping and
centering exceeds 4 .O M between supporting
floor to ceiling including temporary brick or
stone pillars for supporting as required.
j 50 (i)Height more than 4.0 M.and upto 5.0 M. 386.48 Smt
Providing T.M.T Fe 500D bar reinforcement for
R.C.C. work including bending, binding and
placing in position complete up to any floor
a 141490 All Floor Level 75.46 Kg.
Providing and laying polished Kota stone slab
(Polished / River Finish, Green colour ) flooring
over 20 mm. (average) thick base of cement
mortar 1:6 (1 cement : 6 coarse sand) or lime
mortar 1:1.5 laid over and joined with grey
cement slurry including rubbing and polishing
14 1180 complete.25 mm th. 982.83 Sq.M.
Providing and laying polished Kota stone slab
25 mm. thick in Platform ,Riser of Stair
Skirting, Tread , dado and pillars laid on 10 mm.
thick cement mortar 1:3 (1 cement : 3 coarse
sand) jointed with grey cement slurry including
rubbing and polishing and MAking groove
15 295 where it is Required etc. compl 1176.03 Sq.M.
Providing and laying white/Colur glazed tiles
mm thick in flooring treads of steps and landing
laid on a bed of 12 mm thick cement mortar 1:3
(1 cement : 3 coarse sand) finished with flush
16 5 pointing in white cement. 908.17 Sq. M.
Providing and layingWhite / Colour glazed tiles
of size 600 mmx300mm x 8 mm / 300 mmx
450mm x 8 mm in skirting, risers of steps, Floor
and dedo on 10 mm. thick cement plaster 1:3 (1
cement : 3 coarse sand) and jointed with white
17 290 cement slurry. 1426.95 Sq. M.
Providing and laying marble stone slab flooring
over 20 mm. (Average) base of cement mortar
1:6 (1 cement: 6 coarse sand) or L.M. 1:1.5 laid
and jointed with grey cement slurry including
rubbing and polishing complete: (A) Marble slab
18 2 25 mm. thick. 2194.63 Sq. M.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in flooring treads of steps and
landing laid on a bed of 12mm thick cement
mortar 1:3 (1-cement : 3-coarse sand) finishing
19a 60 with flush pointing in white cement. 1062.50 Sq. M.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in skrting risers of steps and
dedo on 10mm thick cement plaster 1:3
(1cement : 3-coarse sand) and jointed with
19b 1028 white cement slurry 1130.15 Sq. M.
P & L 24" x 24" vitrified 8 mm thick tile flooring
over 20 mm (average) base of cement mortar
1:6 ( 1cement: 6 coarse sand) on new surface
or fixing on existing flooring by adhesive
material including dismentaling of existing
flooring and jointed with color cement slurry
including finised with flush pointing & cleaning
19c 210 the surface etc. complete for Antiskid 1383.99 Sq.M.
Providing and Fixing 18 mm thick concrete base
exposed brick cladding including surface
waterproffing, polymer modified tile adhesive
and polymer modifies tile grout ( grey / white)
with neccesary scafolding etc compl. As per
19d 68 direction of engg. Incharge. 3574.35 Sq.M.
Providing and Laying Tactile Tile (For Vision
Impaired Persons as per Strandards) of Size
300x300x9.8 mm Having with Water Absorption
less than 0.5% and Confirming to is:15622 of
Approved Make in all Colours and Shades in for
Outdoor floors such as footpath, Courtyard,
Multi models Location etc., laid in 20 mm Thick
Base of Cement Mortar 1:4 ( 1 Cement :
Course Sand) in all Shapes & pattern including
Grouting the Joints with White Cement mixed
with Matching pigment etc. Complete as per
19e 160 Direction of Engineer-in-charge. 1663.72 Sq.M.
Providing and laying Ceramics tiles 6 to 8 mm
thick in flooring, treads of steps, landing and
dedo on 12 mm. thick cement plaster 1:3 (1
cement : 3 coarse sand) and jointed with white
20 10 cement slurry. 960.47 Sq. M.
Providing & Laying 18 mm thick Mirror polish
granite For flooring , counter , stair -riser , tread
, skirting , dedo , Jambs etc. machine cut or
chiselled on bed of cement mortar 1:1 pointing
with neat cement slurry incl. moulding, Making
grooves where it is required etc. comp. as per
21 320 instruction of engineer in charge. 2385.71 Sq. M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat on fair side of brick /
concrete walls for interior plastering upto any
Floor level and finished even and smooth in
i 3074 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat plastering on ceilings,
Beam side and sofits of stairs upto any Floor
b level and finished even and smooth in C.M.1:4.
i 2105 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken mesh jali
with nails & then application of 15 mm plaster
on R.C.C. & masonary joints as per dir. of engg.
c 1495 In charge. 292.59 Sq.mt
Providing and mixing water proofing materials in
cement mortar in proportion recommended by Per Bag of
the manufacturer. etc. comp. as per instruction 50 Kg of
d 200 of engineer in charge. 48.77 Cement
23a 2525 Providing 20 mm th. Double coat Sand face / 297.68 Sq.M.
Mala Cement Plaster on Walls upto any Height
Above Ground level consisting of 12 mm th.
Backing coat of C.M. 1:3 ( 1 cement : 3 Ssand )
& 8 mm th. Finishing coat of C.M. 1:1 (
cement : 1 sand ) ets. Complete.
White / Color washing with lime on undecorated
wall surfaces (two coats) to give an even shade
including thoroughly brooming the surface to
remove all dirt, dust mortar drops and other
24a 100 foreign matter. 12.29 Sq.M.
Providing & Applying 3 mm thick External Wall
Rustic Type Texture as per Design & Make as
Approved by Consultants / Engineer in Charge.
Work Includes All Necessary Scaffolding Work
24b 1800 upto Any Height. 424.92 Sq.M.
Finishing walls with Acrylic Smooth exterior
paint of required shade :New work (Two or
more coat applied @ 1.67 ltr/10 sqm over and
including priming coat of exterior primer applied
P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE textured
homogeneous wall finishing system from
BAKELITE HYLAM LTD or equivalent make
consisting of a two component system of (25
kgs per Pack) made of 92% silica particles
coated with fade resistant pigments, 100%
acrylic polymer bonding agent (5kgs per pack)
with the applied thickness of the coating being
between 0.8mm-1.2mm to be applied on
acured, smooth level plaster without keying, as
per the shades/combinations approved, as per
the manufacturer directions, for usages, tobe
applied by an approved applicator of the
manufacturer, as per the directions /
supervision of the engineers in charge, all
complete. Includes All Necessary Scaffolding
24d 25 Work upto Any Height. 637.38 Sq.M.
Wall Painting (two coats) with plastic emulsion /
Oil paint of approved brand and manufacture
and of shade required on undecorated wall
surfaces to give an even shade, over and
including a priming coat with alkali resistance
primer of approved brand and manufacture after
thoroughly brushing the surface free from
mortar droppings, and other foreign matter and
also including preparing the surface even and
25a 5000 sand -papered smooth 78.44 Sq.M.
Extra over above item for every subsequent
coat of of wall painting with plastic emulsion /
b 5000 Oil paint of approved brand. 33.39 Sq.mt.
Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of approved
brand and manufacture on new wall surface to
give an even shade including thoroughly
brushing the surface free from mortar dropping
and other foreign matter and sand papered
c 5000 smooth. 40.19 Sq.M.
Providing & Laying & Jointing glazed stoneware
pipes incl. excavation up to 2.0 mt.,refilling,
trasporting the pipe to work site, unloading,
lowering in trenches, laying and jointing the
pipes in c.m. 1:1 incl. all jointing materials such
as cement, sand, hemp, bitumen as dire. testing
the pipe line to a head of 1.5 mt. and hydraulic
test as dire incl. watering trenches, spreading
and carting away of surplus earth within
26 mt.lead as dire. etc. comp.
a 150 23 cm dia. 344.64 Rmt
Providing & Laying & Jointing glazed stoneware
pipes incl. excavation up to 2.0 mt.,refilling,
trasporting the pipe to work site, unloading,
lowering in trenches, laying and jointing the
pipes in c.m. 1:1 incl. all jointing materials such
as cement, sand, hemp, bitumen as dire. testing
the pipe line to a head of 1.5 mt. and hydraulic
test as dire incl. watering trenches, spreading
and carting away of surplus earth within
mt.lead as dire. etc. comp.
b 50 15 cm dia 211.05 Rmt
c 30 10 cm dia. 288.23 Rmt
Constructing brick masonry chamber for under
ground C.I. Inspection chamber and bends with
bricks having croshing strength not less than
Kg. Cm2 in C.M. 1:5 C.I. cover with frame
(Lightduty) 455mm x 610 mm intenal
dimensions total weight of cover with frame to
be not less than 38 Kg. (Wt. of cover 23Kg.)
and Wt. of frame 15Kg.) (R.C.C.top slab with
1:2:4 mix (1-cement:2-coarse sand:4-graded
stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15 mm thick with
cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete.(i) Inside dimensions
27 18 455 mm x 610 mm and up to 850 mm deep 3863.85 No.
Constructing Manhole with R.C.C. top slab in
1:2:4mix (1-cement: 2-coarse sand:4-graded
stone aggregate 20 mm nominal size)
foundation concrete 1:3:6 mix (1-cement:3-
coarse sand:6-Brick bats 40+50mm size) inside
plastering 15mm thick with Cement Mortar 1:5
(1-Cement:5-coarse sand) finished with a
floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-
Cement:2 -Coarse sand:4-stone aggregate
mm nominal size) finished smooth complete
including curing and festing (i) Inside size
900mm x 1200mm and up to 1.5M. deep
including C.I. cover with frame size 560 mm
diameter total weight of cover and frame to be
not less than 128kgs. (Wt. of cover 64Kg. and
Wt. of frame 64Kg.) (A) With 230 mm thick walls
of brick masonry using brick having crushing
strength not less than 35Kg./Sq.cm. in Cement
Mortar 1:5 (1-Cement: 5-Coarse sand) (2)B
28 a 4 type depth up to 1.50 Metre 19139.07 No.
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal basin
of 340x280x470 mm sizes respectively with
standard flush pipe, Waster Pipe, Waste
Coupling, PVc Connection and G.I clamps
complete, including painting of fittings and
brackets, cutting and making good the walls
and floors wherever required : Cera Model No.
29a 16 S4020103 or Equivalent 3344.35 No.
Providing and Fixing of C.P. Brass BIB Cock of
15 mm Dia of Jaquar make florentine series
model no. 5047n or equivalent make with all
necessary fittings. as approved by Engineer - in
b 80 - charge., 1564.17 No.
Providing and fixing brass screw down Angle
stop tap.(A) 15mm dia. Of Jaquar make
florentine series modelno. 5053n or equivalent
make with all necessary fittings. as approved
c 80 by Engineer - in - charge., 1160.57 No.
Providing and fixing C.P. brass shower rose
with 15mm or 20mm inlet Shower Arm.(A)
d 20 100mm dia. Each 279.37 No.
Provding and Fixing of autoclosing pressmatic
pillar cock / bib cock with all necessary fittings
of Polished Bright Chrome Finish of Jaquar
make model no. 031L65 or equivalent make as
approved by Engineer in Charge. Rate including
of cost of labour, material etc. in complete
e 18 manner. 3280.52 No.
Providing and Fixing of C.P. Brass Two Way
Bib Cock of 15 mm Dia of Jaquar make model
no. 041kn or equivalent make approved make
with all necessary fittings. as approved by
f 20 Engineer - in - charge., 1411.58 No.
Providing and Fixing of C.P. Brass urinal Valve
Auto Closing System With Full Built in Control
Cock & Wall Flange of 15 mm Dia of Jaquar
make model no. 077 or equivalent make
approved make with all necessary fittings. as
g 16 approved by Engineer - in - charge., 2568.08 No.
Providing and Fixing of C.P. Brass Pillar Cock
Auto Closing System with Elbow Operated
Extended Lever of 15 mm Dia of Jaquar Make
Model No,031 MED or Equvalent Approved
Make & Model with all necessary fittings. as
h 1 approved by Engineer - in - charge., 3723.48 No.
Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water tight
C.I. cover with frame of 300 mm x 300 mm size
( inside) with standard weight. sqare mouth trap
30 20 size 150 x100 mm P trap 1234.57 No.
Providing erecting and fixing double coated ISI
water tank of required capacity each with all
necessary fittings and connection etc. complete
31 2000 on terrace 3.91 Litre
32 20 Extra rate over item of excavation of earth for 71.43 Sq.M.
excavation of asphalt pavement/RCC of
thickness up to 0.20 meter including
demolishing the asphalt carpet, metal, soiling /
cutting Reinforcement etc.comp. with stacking
the material as directed.-up to 0.20 meter
Providing and fixing PVC SWR Nahni trap IS
14735 for drain - 100 mm diameter with jali of
following nominal diameter of self cleansing
design with C.I scread down or hinged grating
including the cost of cutting and making good
33 50 the walls. 565.43 No.
Provdg. And fixing Concealed / Open to wall,
ceiling & floor in true line and level UPVC pipe
Schedule- 40 of make as approved by engg.
incharge. pipe shall be fix on wall with the help
of clamp at every twi meter center to center of
shall be concealed as directed in cluding
neccesarry fitting etc. in cluding testing of pipe
and jointd and fixing the same with adhesive
solvent , including cost of all materials of
34a following nominal bore
ii 400 25 mm 90.93 Rmt
iii 50 32 mm 117.97 Rmt
iv 180 40 mm 146.65 Rmt
Providing and fixing concealed center point to
wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal
bore tube fittings and clamps including making
34b good the wall, ceiling and floor etc. complete
ii 40 20 mm 202.97 Rmt
iii 150 25 mm 247.25 Rmt
iv 10 32 mm 330.36 Rmt
vi 20 50 mm 647.30 Rmt
Provdg. And fixing to wall ,ceiling and floor
10.00 kg. F/Sq.Cm2 working pressure
polythelene pipes of the following outside
diameter, low, density, complete with special
flange compression type fittings, wall clips etc.
35 making good wall ceiling and floor.
b 80 (A) 75mm dia 274.68 Rmt
c 200 © 110 mm dia 332.91 Rmt
Providing and fixing water closet squatting Pan
( Indian type W.C. Pan) size 580mm
(A)VitreousChina. (I)Long pattern = White
36 8 colour with Trap and Pair of Foot Rest 1351.15 No.
Providing and fixing white vitreous china
extended wall mounting water closet of Cera
Make S1043101 Carat Model Or Equivalent
Model With EWC Soft Close Seat Cover, Chair
37a 12 Bracket, nuts, bolts and gasket etc complete. 12613.27 No.
Providing and fixing chromium plated brass half
trun flush cock of approved quality including
b fixing in pipe line etc. complete.
Providing and fixing Health Faucet of Jaquar
make model no. 573 oe equivalent make as
approved by engg. In charge with flexible tube
c 12 upto 1 metre long etc. complete. 1543.36 No.
Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single Bowl
Sink S.S. Matt Finish With Waste Coupling,
Waste Pipe,etc. cutting and making good the
38a 6 walls wherever required. 7960.60 No.
Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar tap,
32 mm C.P. Brass Waste of Standard make,
Include All Accessaries, Cutting & Making good
the wall / granite Wherever Required in White
Color : Model S2030101 of Cera Clair Series or
Equivalent make Waash basine of size :
Providing and fixing Wall Hung wash basin
Including 32 mm C.P. brass waste of standard
pattern, Include All Accessaries, cutting and
making good the walls / granite wherever
require:In White Color : Cera Cadal Or
Equivalent Make Wash basin of size 515 x
Providing and Fixing White Vitreous China
Laboratory Sink with C.I. Brackets, C.P. Brass
Chain with Rubber Plug, 40 mm C.P. Brass
Waste and 40 mm C.P. Brass Trap with
Necessary C.P. Brass Unions Complete,
Including Painting of Fittings and Brackets,
Cutting and Making Good to Wall / Granite
d 1 Wherever Required: Size 600 x 450 x 200 mm 5581.19 No.
Provdg. & fixing 600mm x 450 mm Bevelled
edge mirror of superior glass mounted of .6 mm
th. A.C. sheet or plywood sheet and fixed to
wooden pluge with C.P. brass screws and
39a 12 washers. 825.48 No.
Provdg. & fixing C.P..Brass towal rail complete
with C.P. brass brackets fixed to wooden plugs
40 25 with C.P. Brass screws.(600 mmx 20 mm size) 597.22 No.
Providing and fixing ball valve (brass) of
approved quality, High or low pressure, with
41 plastic floats complete :
i 10 15 mm dia 886.22 No.
ii 1 20 mm dia 1099.94 No.
iii 35 25 mm dia 1552.93 No.
iv 8 40 mm dia 3312.60 No.
v 2 50 mm dia 4613.48 No.
Providing and fixing Full Way valve (HEX) with
42a wheel of approved quality :
i 2 15 mm Full Way valve (HEX) 1461.17 No.
ii 1 20 mm Full Way valve (HEX) 1924.61 No.
iii 10 25 mm Full Way valve (HEX) 2535.55 No.
iv 1 32 mm Full Way valve (HEX) 3377.64 No.
v 3 40 mm Full Way valve (HEX) 4661.10 No.
vi 2 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar Cock of
15 mm Dia of approved make with all
necessary fittings. as approved by Engineer - in
43a 1 - charge., 1725.21 No.
Providing fixing of SS grab bar with all
b 10 hardwares for Physically Handicap toilet. 1937.24 No.
Providing and laying integral cement based
water proofing treatment including preparation
of surface as required for treatment of roofs,
balconies, terraces etc consisting of following
44a 380 operations: 1150.48 Sq.M.
(a) Applying a slurry coat of neat cement using
2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC
slab including adjoining walls upto 300 mm
height including cleaning the surface before
(b) Laying brick bats with mortar using broken
bricks/brick bats 25 mm to 115 mm size with
50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound
conforming to IS : 2645 and approved by
Engineer-in-charge over 20 mm thick layer of
cement mortar of mix 1:5 (1 cement :5 coarse
sand ) admixed with water proofing compound
conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and
treating similarly the adjoining walls upto
mm height including rounding of junctions of
walls and slabs.
(c) After two days of proper curing applying a
second coat of cement slurry using 2.75 kg/
sqm of cement admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge
(e) The whole terrace so finished shall be
flooded with water for a minimum period of two
weeks for curing and for final test.“All above
operations to be done in order and as directed
and specified by the Engineer-in-Charge :and
shall be guaranteed for minimum period of
years after handing over the completed building
by the main contractor to be finished as
directed. Stamp paper guarantee 10 years to
be furnished before receiving any payment from
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
b 380 cement mortar 1:3 to plain or slope and to be 739.89 Sq. M.
tempered to bring mortar creme out upto
surface using white cement including rounding
off junctions and extending them upto 15 cm
along the wall,clearing with water and oxalic
acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/
sqm. One coat of self-priming of elastomeric
waterproofing liquid (dilution with water in the
ratio of 3:1) and two coats of undiluted
elastomeric waterproofing liquid (dry film
thickness of complete application/system not
less than 500 microns). The operation shall be
carried out after scrapping and properly
cleaning the surface to remove loose particles
with wire brushes, complete in all respect as per
c 490 the direction of Engineer-in-Charge. 562.40 Sq. M.
Filling in Sunken Portion with good Quality
Aerated light weight concrete block having
crushing strength not less than 35 kg/sqcm and
where directed by the Architect / Engineer-in-
charge, in sunk in layer. including watering,
ramming where it is required etc. complete, as
d 98 directed by the Architect / Engineer-in-charge . 4559.61 Cmt
Providing and laying cement concrete flooring (
I.P.S.) 1:2:4 (1-cement : 2-coarse sand : 4-
graded stone aggregate 20mm nominal size)
laid in one layer and finished with a floating coat
45 280 of neat cement. (B) 50mm thick. 348.08 Sq.M.
Providing and fixing M.S. grills/ Gate of required
pattern to wooden/ Granite frames of windows
etc. with M.S. flats at required spacings and
frame alround, square or round bars with round
headed bolts and nuts or by screws all
complete as per the structural designs and
46a 7000 directions of Engineer in charge 100.17 Kg.
Providing & Fixing Structural steel work (
Confirming to IS 4923-1997) riveted, bolted or
welded in builtup for all type sections, in framed
work, including cutting, hoisting, fixing in
position and applying a priming coat of
approved steel primer all complete as per the
structural designs and directions of Engineer in
b 2000 charge 126.68 Kg.
Applying priming coat over new steel and other
metel surface after and including preparing the
surface by throughly cleaning, oil, grease, dirt
and other foreign matter and scoured with
brushes fine steel wood, scrapers and sand
paper with ready mixed priming paint brushing
c 600 red lead. 34.34 Sqmt
Painting two coats (excluding priming coat) on
new steel and other metal surface with enamel
paint, brushing, interior to give an even shade
including cleaning the surface an even shade
including cleaning the surface of all dirt, dust
d 600 and other foreign matter. 86.94 Sqmt
Providing & Fixing 1.2 mm Thick S.S.-304
Grade 900 mm to 1150 mm High S.S. Railing
having Hand Rail Member of 50 mm Dia., 4 No.
of Horizontal Pipe of 16 mm Dia. & Baluster
Suppprt of 40 mm Dia. At Every Third Step as
per Detail Given. Rate Includes All Work
Complete as per Description & as per Direction
e 120 of Engg. in Charge. 2270.21 R.Mtr.
Providing and fixing in position collapsible steel
shutters with vertical channels 20x10x2 mm
braced with flat iron diagonals 20x5 mm size
with top & bottom rails of T-iron 40x40x6 mm
with 38 mm dia. Steel pulleys complete with
bolts , nuts , locking arrangement , stoppers
handles including applying a priming coat of red
47a 23 lead paint. 5391.23 Sq. M.
Providing corrugated 0.80 mm (22 gauge) thick
G.I. sheets roofing fixed with galvanized iron ‘J’
or ‘L’ hook bolts, and nuts 8 mm. dia with
bitumen and G.I. limpet washers filled with
white lead complete excluding the cost of
b 5 purlines, rafters and trusses. 719.93 Sq.M.
Providing valleys 900 mm. overall in plain
mm. thick G.I. sheet Class – 3 fixed with ‘J’ or
‘L’ hook bolts and nuts galvanized from ‘J’ or ‘L’
c 2 hook bolts and bitumen washers complete. 1042.78 Sq.mt.
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S. laths inter-
locked together through their entire length and
jointed together at the ends by end locks
mounted on specially designed pipe shaft with
bracket plates, guide channels and
arragements for inside and outside locking with
push-pull operation including the cost of hood
cover and spring etc. complete.(A) Shutters
48a 9 having width below 3.5 M. 3468.72 Sq.M.
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S. laths inter-
locked together through their entire length and
jointed together at the ends by end locks
mounted on specially designed pipe shaft with
bracket plates, guide channels and
arragements for inside and outside locking with
push-pull operation including the cost of hood
cover and spring etc. complete. (B) Shutters
b 12 having width 3.5 M. and above 4450.51 Sq.M.
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Three track Sliding
window With Metalic Powder Coating and 4 MM
Clear Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as per
49a 108 the direction of Engineer-in-charge. 6373.85 Sq. M.
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Two track Sliding
window With Metalic Powder Coating and 4 MM
Clear Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as per
b 35 the direction of Engineer-in-charge. 4999.10 Sq. M.
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door work
(Single Shutter OR Double Shutter with or
without fix glass) made from Jindal or
equivalent make Powder Coated (50 micron
pure polyester coating ) ,aluminium section
frame built up standard tubular and other
section of approved make confirming to IS
and IS 1285 , member size with shutters of
horizontal member , vertical member
Confirming to IS733 and IS 1285 fixed with rawl
plug abd screws or fixing clips or with
expansion hold fasteners including necessary
filling up of gaps at junctions at top bottom and
sides with required PVC/ Neoprene felt, 8/12
mm toughened glass of approved make etc.
Aluminum sections shall be smooth, rust free,
straight.mitred and jointed mechanically
wherever required including Door Hardware
such as cleat angles aluminum snap beading
for glazing /paneling, CP Brass/ Stainless steel
screws, Stoppers, heavy duty floor hing, S.S.
Hinges, aldrop , Locking system, heavy duty
Floor Springs, Pivot and fixtures and
transparent silicon sealant glass fixing to frame
as per details all complete as per architectural
drawings and the direction of Engineer in
Charge. rate incl. all type of alumnium sections
c 14 for doors as per the detail Architectural dwg. 5401.70 Sq. M.
Providing and fixing standared extruded of
alluminium section of size 63 mm x 38.10 mm x
1.2mm (Section:2434, @ Wt.0.643Kg/mt ) with
colour anodized alluminium frame for ventilation
with 5 mm thick frosted glass as details etc
50 a 20 complete for Ventilation 1163.92 Sq. M.
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
mm ( Section no: 4605, @Wt 1.094 Kg / Rmt
with colour anodized alluminium frame with
mm thick transparent bronze colour tinted float
50 b 3 glass as details etc complete for Fix window. 1509.90 Sq. M.
Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly Panelled
Partly Glazed / Fully Panelled , Having Size of
Section of 2.1/2 x 1.1/2 with 4 mm Compact
Sheet / 5 mm thick Glass Fixing with 4 mm thick
EPDM Rubber etc. Complete as per Direction of
50c 36 Consultant / Engg.incharge. 3124.44 Sq.mtr.
Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled , frame
Having Size of Section of 2 .1/2 x 1 .1/2 and
Door Section Having Size of Tips Vertical
.3/4 x 1 .3/4, Top Rail 4 x 1 .3/4, Middle Rail
.3/4 x 1 .3/4, Bottom rail 4 x 1 .3/4 with 4 mm
Compact Sheet / 5 mm thick Glass Fixing with
mm thick EPDM Rubber Including Lock,
Handle, Door Closer, Door Stoper, Stopper etc
Complete as per Direction of Consultant /
50d 4 Engg.incharge. 4061.77 Sq.mtr.
51a 8 Providing and fixing Structural Glazing with 3953.75 Sq.mt.
using the 17 Micron anodised of approved
colour alluminium section as transium, mullium
of size 63mm x 38mm x 2 mm with using 6 mm
thick reflective structural glass of approved
make, colour / Tinted, toughned and shade and
fixed with silicone sealant and spacer tap and at
corner sealed neoprene foam dust and Air
sealed gasket mirred including scaffolding,
cleaning of glass etc.complete at all heights anf
lifts with all necessary fitting and fixtures,
anchore fasteners, necessary M.S. or
Aluminium brackets, suitable design for
openable or sliding window as per Architectural
drawing and as directed by Engineer-in-charge.
Grooves between the glasses to be filled with
sealant of Dow corning - structural sealant
weather sealant 789. The entire facade should
be water proof. The mullions are to be
connected to bracket by SS-304 nut bolts.
Measurement shall be given as per actual
execution of the work. (Rate are included
providing & fixing of MS structure steel work
wherever Required)
Providing and fixing ISI marked 35 mm thick
flush door shutters conforming to IS : 2202 (Part
I) decorative type, core of block board
construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers
on both faces of shutters with 1.00 mm thick
Decorative Laminated Sheet on both faces of
shutters including ISI marked Stainless Steel
butt hinges, bright /matt finished 125 mm
Stainless Steel handles of approved quality &
make, ISI marked oxidised M.S. door latches /
Aldrop Conforming to IS:5930 with necessary
screws etc. complete as per direction of Engg.
52a 108 incharge. 4332.15 Sq.mt.
Providing wood work in frames of Doors,
windows cleare story windows and othersimilar
works wrought, framede and fixed in position.
b 282 (A) Indian Teak Wood 602.04 Cu.Decim
Providing and fixing 35 mm th. Shutters for
doors windows & clearstory windows incl.
wood frames as specified 12 cm. x 7cm. size
incl. anodised alluminium fixtures and
fastenings including primer coat of approved
53 quality and two coats of oil paint etc. complete.
a 3 Fully glazed 4788.50 Sq. M.
b 3 Fully panelled 5478.89 Sq. M.
c 3 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and Fixing FRP FRAME size 125 x
mm and 35 mm thick FRP shutter with wood
grain raised pannel design finish shutter having
extra reinforcement on sides and edges and in
polish finish The core of the shutter is to be
filled up with injected fire extingushing
grade.polyurethane foam done in situ along
with embedded wooden pieces for stiffering and
54 77 also for tacking hinges and fixtures. The whole 1999.98 Sq.M.
FRP frame and shutter is to be water
proof.weather proof,tennite proof and resistance
to mild acid/ Alkali, Rates are to be inclusive of
S.S. hinges with necessary screws and brass
fixtures and fasening.
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be well
55 repaired as per instructions. etc..complete.
a 1 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild steel
distribution branch with galvanised mild steel
main 50mm to 80mm nominal bore by providing
and fixing tee including cutting and threading
56 1 the pipes complete 600.08 No.
Providing throating or plaster drip, grooves and
57a 1000 moulding to Wall , R.C.C. chajja and slab. 41.25 Rmt
Providing & Laying cement vatta 10 cm x 10 cm
in size quarter round in c.m. 1:1 ( 1 cement,
coarse sand) laid in one layers finishing with a
floating of neat cement watering etc complete
57b 220 as dire. 23.45 Rmt
Carring out plinth treat ment to post
construction/ existing structure by spraying
chemical solution for termite control treatment
including labour and material consist ment
withI.S.I specification. Using Chlordene and
Chiorpur files 20EC. As Per 6131_ paret- II
Consentration Weight one percent is
recommended i.e one litre 20EC chemical
emulsion with19 liter give1% concrentration
inclusive of one litre chemical emulsion
appication at the rate of 5 Litre chemical/ Sqm
58 400 of surface is recommended as per I.S 104.09 Sq.mt
Carring out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work for
termite control including labour and material etc.
complete. Using Chlordene 20EC. As Per
6113_part III Consentration Weight
percent is recommended one litre chemical
emulsion dillute with 9 liter of kerosene precent
concentration. Total dillute concrentration will
be10litre inclusive of the litre chemical emulsion
application 0.75/Litre chemical per one Sqmt
59 10 printed two coat wood surface. 54.98 Smt
Paver Block Providing and laying shot blasted
Non - interlocking, Paver blocks of specified
thickness, size, grade of concrete and colour
machine made and blasting by automatic shot
blasting machine and high density of as per
approved sample of approved make for
footpath, parking areas, service lanes,cross
over and other areas as mentioned in the
drawing. Including providing and laying 50 mm
thick averave bedding layer of coarse sand
below paver block as per required grading and
60 150 specification. Laid paver block shall be 758.93 Sq.mt.
mechanically compacted. The work of the
paving blocks shall be executed in line and level
by skilled mason of flooring work only. Small
size of paver block with same specification shall
be used at residue or at end. It should be laid in
such a way that the no cutting of the paver
block to be necessary. If cutting of paver block
shall be required , than cut by machine only and
laying to be done by skilled flooring mason. The
finished surface of the paver block shall have
coarse sand Texture Finish. Pave blocks shall
be compacted and shall be re-laid if necessary.
Actual laid area shall be measured and paid
without any wastage. (A) 80 mm thick M-35
grade Grey Paver block of size 200mm x
200mm. As per approved rate
SProviding and fixing pre-cast concrete kerb
stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of
M250 grade concret as per approved design
and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3
61 300 (1cement:3fine sand) etc complete. 358.06 R.mt.
Providing and fixing double action hydraulic
floor spring of approved brand and manufacture
conforming to IS : 6315, having brand logo
embossed on the body / plate with double
spring mechanism and door weight upto 125 kg,
for doors, including cost of cutting floors,
embedding in floors as required and making
good the same matching to the existing floor
finishing and cover plates with brass pivot and
single piece M.S. sheet outer box with slide
plate etc. complete as per the direction of
Engineer-in-charge. With stainless steel cover
62a 2 plate minimum 1.25 mm thickness 4558.89 No.
Providing and fixing aluminium extruded section
body tubular type universal hydraulic door
closer (having brand logo with ISi, IS :
embossed on the body, door weight upto 36 kg
to 80 kg and door width from 701 mm to
mm), with double speed adjustment with
necessary accessories and screws etc.
b 22 complete. 1626.10 No.
Designing, fabricating, testing, installing and
fixing in position Curtain Wall with Aluminium
Composite Panel Cladding, with open grooves
for linear as well as curvilinear portions of the
building , for all heights and all levels etc.
63 50 including: 3061.95 Sq.mt.
(a) Structural analysis & design and preparation
of shop drawings for pressure equalisation or
rain screen principle as required, proper
drainage of water to make it watertight including
checking of all the structural and functional
(b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of
approved shades made out of 4mm thick
aluminium composite panel material consisting
of 3mm thick FR grade mineral core
sandwiched between two Aluminium sheets
(each 0.5mm thick). The aluminium composite
panel cladding sheet shall be coil coated, with
Kynar 500 based PVDF / Lumiflon based
fluoropolymer resin coating of approved colour
andshade on face # 1 and polymer (Service)
coating on face # 2 as specified using stainless
steel screws, nuts, bolts, washers, cleats,
weather silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy
6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the
wind load movement, fasteners, SS 316 Pins
and anchor bolts of approved make in SS
Nylon separators to prevent bi-metallic contacts
all complete required to perform as per
specification and drawing The item includes
cost of all material & labour component, the
cost of all mock ups at site, cost of all samples
of the individual components for testing in an
approved laboratory, field tests on the
assembled working curtain wall with aluminium
composite panel cladding, cleaning and
protection of the curtain wall with aluminium
composite panel cladding till the handing over
of the building for occupation. Base frame work
cost for ACP cladding is included in this item
rate. The Contractor shall provide curtain wall
with aluminium composite panel cladding,
having all the performance characteristics all
complete , as per the Architectural drawings, as
per item description, as specified, as per the
approved shop drawings and as directed by the
Engineer-in-Charge. However, for the purpose
of payment, only the actual area on the external
face of the curtain wall with Aluminum
Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two
decimal places.
Providing and Fixing Box type metal letters
forming composite box made from 1mm thick
stainless steel plate of grade 304 having brush
finish of following font size to be fixed at Main
Gate in english and or Gujrati and including
fixing charges. etc. complete as per direction of
Engg. incharge. for Payment Purpose Height of
64 Letter will be measured.
a 960 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out of 2mm
thick s.s. plate grade 304, including making
necessary design as per Architect dwg.
Through laser cutting including connection to
the R.C.C./Masonary with necessary
frame,anchor fastnuts,M.S.Plate etc. complete
65a 5 as per direction of Engg. incharge. 6804.07 Sq.mt.
Providing and Fixing Sinage - internal and
external signage boards with Vinyle Text on
ACP sheet / 2 mm th. S.S. Plate etc. complete
65b 12000 as per direction of Engg. incharge. 9.38 Sq.Inch
Providing and fixing retro Reflective Hi Intensity
Micro Prismatic Grade Board using 2mm
Aluminum / 4mm ACP, angle iron 75 x 75 x
6mm. Descaling and degreasing the board as
per requirement using epoxy reflactive process
by screen painting as directed etc. complete
including transporting and fixing in C.C. 1:2:4
with necessary excavation curing etc. complete
as per I.R.C. 67-2012 design. A warranty for
years for the Retro reflective sheeting from
original manufacturer & a certified copy of
year outdoor exposure test report from third
party test lab for the product offered shall be
submitted by contractor. (B)Class B Type-
65c 5 4(MDR/ODR) retro reflective sheeting 7535.31 Sq.mtr.
Road marking with hot applied thermoplastic
paints with reflectorising glass beads on bitumin
surface providing and laying a hot applied
thermoplastic compound 2.5 mm thick including
reflectorising glass beads @ 250gms per sqm
area, thickness of 2.5mm is excluding of
surface applied glass beds as per IRC:35-2015.
The finished surface to be level, uniform and
free from streaks and holes. zebra patta /bump
patta lane/center line/ edge line/cut patta. The
white color marking should provide liminance
coefficinet on cemend road shalll be min
mcd/m2/lux and Asphalt road shall be min
mcd/m2/lux during the service life during the
day time. The marking should meet the
performance criteria for night time reflectivity,
wet reflectivity and skid resistance as
mentioned in the section-15 of IRC
Warranty for the Retro reflectivity should be two
65d 80 years. 364.08 Sqmt
CAT EYE/Pavement Marker(MNC two nail)
made out of acrylic StreneAcrylonitrile or hi-
impact poly Steren fitted with moulded of
metheacrylate(MNC)reflector cube corner
reflector design,filled with tightly adhering
pooting compound as per ASTMD-788 size
11.5x7x1.60 cms or 10x10x1.75 cms provided
with bituminous adhesive in sufficient quantity
with each unit fixing with two shrank .Reflector
on both side.Co efficient of lumination as per
specification and compressive strenth 13 tones
at 23 degree centigrade etc.B) Double side
65e 10 lenses. 160.71 Nos.
Providing and fixing eco-friendly light weight
calcium silicate false ceiling tiles having T
egular edge & 15mm Thick Densified edges on
the Tile Periphery for Extra Strength The Light
weight calcium silicate ceiling tiles shall have,
light reflection 85% non-combustible as per
B.S.476 part IV, 100% humidity resistance and
also having thermal conductivity 0.043° w/m
66a 40 KC. for the best thermal Insulation. 1632.63 Sq.mt.
The Light weight calcium Silicate tile shall be of
approved texture Fine fissured/ Spintone/
Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of
size 595X595 mm to be laid on true horizontal
level suspended inter locking metal grid of hot
dipped galvanized steel sections (galvanizing @
120 grams per sqm including bothside)
consisting of main ‘T’ runner suitably spaced at
joints to get required length and size of 24X38
mm made from 0.30 mm thick (minimum) sheet,
1200 mm centre to centre, and cross ‘T’ of size
24X28 mm made out of 0.33 mm (Minimum)
sheet spaced 1200 mm along spaced between
main ‘T’ at 600 mm centre to centre to form a
grid of 1200X600mm and secondary cross ’T’ of
length 600mm and size 24x28mm made of
mm thick (Minimum) sheet to be interlocked at
middle of the 1200X600mm panel to form grid
of size 600X600mm resting on periphery walls /
partitions on a perimeter wall angle pre-coated
steel of size (24X24X3000mm made of 0.40mm
thick (minimum)
sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry wall screws
@ 230mm interval and laying 15mm thick
Densified edges light weight calcium silicate
ceiling tiles of approved texture (Fine Fissured/
Cosmos/Spintone) in the grid including, cutting
/making opening for services like diffusers,
grills, light fittings, fixtures, smoke detectors
etc., wherever required, Main ‘T’ runners to be
suspended from ceiling using G.I. slotted cleats
of size 25X35X1.6mm fixed to ceiling with
12.5mm dia and 50mm long dash fasteners,
4mm G.I. adjustable rods with galvanized steel
level clips of size 85X30X0.8mm, spaced at
1200mm centre to centre long main ‘T’ bottom
exposed with 24mm of all T-sections shall be
pre-painted with polyester baked paint, for all
, as per specifications, drawings and as directed
by engineer-incharge.Note:- Only calcium
silicate false ceiling area will be measured from
wall to wall. No deduction shall be made for
exposed frames/ opening (cut outs) having area
less than 0.30 sqm. The calcium silicate ceiling
tiles shall have NRC. Value of 0.50 (Minimum)
for Fine fissured/ Spintone/ Cosmos and
NRC for Globe, light reflection 85%
noncombustible as per B.S. 476 part IV, 100%
humidity resistance and also having thermal
conductivity. 0.043° w/m KC.for the best
thermal Insulation
Providing and fixing single layer water proof
gypusm board 12.5 mm thick of the make New
good Group Co.Ltd. or equivalent & New good
Group Co.Ltd. company sections using water
proof board of size 1220 mm x 1830 mm x
mm suspended by G.I suspender of size 25 mm
x 3 mm with intermediate channel of size 18mm
x40mm x0.80mm at 1220 mm center to center
ceiling section of size 40mmx 35mmx 0.55mm
at 457 mm center to center and perimetre
66b 40 chanel A of size 20mm x 27mm x 30mm x 600.94 Sq.mt.
0.50mm at edges & drops including paper taps
and sofit cleat, anchor fastener, scoch bolt
connecting cleat joining compound top coat on
ceiling including making necessary opening for
light fitting, diffuser etc. complete as per detail
drawing as directed.
Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet fixed with
hilti screw and rubber silicon sealer and
alluminium strip of size 50 x 3 mm etc complete
67 5 as directed by Engineer in charge 1427.62 sq.mt.
Manufacturing,testing ,supplying
loading,,transporting to work site,loading
unloading lowering in trenches,laying and
jointing RCC NP3 class pipes in C:M 1:1
including all jointing materials such as
cement,sand,hemp bitumen as directed testing
the pipe line to a head of 1.5 mt and hydraulic
68 test as directed etc comp.
a 90 300 mm Diameter 616.07 Rmt
b 10 450 mm Diameter 806.25 Rmt
Constructing Bombay Pattern Type Catch Pit of
size 0.60 x 0.60 depth up to 1 mt including
excavation, B.B.C.C. (1:5:10), 23 cms thick
brick maso. wall in the prop. of CM (1:6) with
mm thick IPS flooring in the prop M15 at bottom
and 15 mm thick cement plaster inside the
catch pit in the proportion of CM (1:3) with out
69 10 jali etc. comp. as directed. 3125.00 No
CatchPit Jali Fixing P/F FRC catch pit jali with
frame 600mm x 600mm clear opening etc.
70 10 comp.. As directed by engineer in charge. 1383.93 No
PERCOLATION WELL
Drilling of pilot bore hole in Alluvial Strata by
71 120 direct Rotary Rig of 250 mm. 694.64 Rmt
72 120 Reaming 400 mm 212.50 Rmt
73 1 Electro Logging charges with carting 16071.43 Job
Providing and Installing 200 mm dia IS:12818
74 60 upvc Casing Pipe "CM" class plain Pipe 1193.75 Rmt
Providing and Installing 200 mm dia IS:12818
75 1 upvc End Cap, with Air Vent cowl 669.64 Set
200 mm dia Regular with 1.5 mm sloted size
cage type trapezoidal shape wire wound little
76 60 carbon galvanized screen confirming to IS:8110 1146.43 Rmt
77 10 Supply of Pea sized Gravel 2029.46 Cmt
78 1 Air Vent of 50 mm Bend 401.79 Unit
Lowering and Removing of Dropline up to
79 120 Depth 186 mtr. 147.32 Rmt
80 1 Air Compressor 60 CFM/150 PSI 22205.36 Ls
Estimate For Civil Work With Percolation
Annual Comprehensive Maintenance of the
Civil Work for 4 Year after completion of
81 DLP ( 1-Years)
Annual comrehensive maintenance charges for
1-Year of DLP + 4 year for Entire Civil Work at
site including with all genunine spares, Annual
comprehensive maintenance period starts after
completion of Defect Liability period of Project.
Payment for Annual Comprehensive
Maintenance shall be made on quarterly basis
& after completion of each quarter For the
Executed Tender Items by Considering Tender
Rate. No Price Variation shall be Given For Any
a 1 DLP-1 Year Free Job
Annual comprehensive maintenance Charges
for First year After Guarentee / Defect Liability
b 1 Period . 214040.15 Job
Annual comprehensive maintenance Charges
for Second year After Guarentee / Defect
c 1 Liability Period . 321060.23 Job
Annual comprehensive maintenance Charges
forThird year After Guarentee / Defect Liability
d 1 Period . 428080.30 Job
Annual comprehensive maintenance Charges
for Fourth year After Guarentee / Defect Liability
e 1 Period . 535100.38 Job
TOTAL OF Annual Comprehensive
MAINTENANCE CONTRACT of Civil Work
I. No. Qty Items Unit Rate Per Amount
Electrical Work Estimate
1 INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories
and earth continuity of following type, erected
on PVC / Metallic/Wooden box, single mounting
base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling
1.1 rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
230 complete 505.05 Pt
Point wiring for FAN with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade ZHFR/HRFR PVC
insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A
Modular type switch and hum free EME four or
more step type electronic fan regulator with
separately mounted and accessories with earth
continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose /
1.2 H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
80 complete 701.40 Pt
Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade ZHFR/HRFR
PVC insulated multi strand copper wires, in
below type of pipe to be erected complete with
earth continuity and necessary connection with
primary light with accessories erected on Metal
/ PVC / wooden box covered covered with
appropriate front plate modules erected on / in
wall / ceiling for open / concealed wiring. with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe erected
1.3 with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
125 complete 174.30 Pt
Point wiring for Individual Plug with & earth
wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete
with Modular type switch & 5 pin Plug erected
on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in
wall / ceiling as per pipe erected with following
1.4 type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm
Cu. Wire from nearby switchboard/mcb db
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
[II] For 16A Plug and 16 amp switch with 2-2.5
1.4.2 15 sq.mm Cu. Wire from mcb db board. 774.90 Pt
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
[III] For 16A Plug and 16 amp switch with 2-4
sq.mm Cu. Wire with 2.5 sq.mm ( green)
1.4.3 6 earthing wire from mcb d b board. 906.15 Pt
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate modules erected on /
1.5 100 in wall / ceiling with following type accessories 255.00 Pt
Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of .ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires erected in below type of pipe with
6A Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden
box, single mounting base frame covered with
textured / metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected.
with necessary batten/angle holder or ceiling
1.6 rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
10 complete 627.90 Pt
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
1.7 Engineer In charge.
1.7.1 5 (1)One No. SP 6 Amp. 150.00 E.a.
1.7.2 5 (2) One No 5 pin plug 150.00 E.a.
1.7.3 60 (7) Blank Plate Single 25.00 E.a.
1.7.4 1 (8) Computer RJ-45 socket 159.00 E.a.
1.7.5 6 (9) 16 Amp. SP one way switch 179.00 E.a.
1.7.6 6 (10) 6/16Amp. Universal socket 198.00 E.a.
(13) 6A/10A/16A/20A/25A/32A Single pole
1.7.7 2 Modular MCB Switch 307.00 E.a.
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole
1.7.8 8 Modular MCB Switch 406.00 E.a.
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
1.8 dia of pipes, in approved manner as directed
Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following
providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non
PVC Zero Halogen free fire retardant insulated
copper conductor, insulated wire (HRFR)
conforms to IS-694, erected in existing pipe with
1.5sq. mm copper conductor of same
specifications for earth continuity of following
In Existing medium class Rigid PVC pipe and
1.10.4 15 (b) 2 wire 6 sq. mm 139.00 Mtr
providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth
1.11 continuity of following size
(A) with medium class Rigid PVC pipe and
(i) 4 wire 10 sq. mm
1.11.2 140 (use earth wire of 4 sq.mm ) 421.00 Mtr
providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts
1.12 if required.
1.12.1 20 (e) One wire 6.00 sq. mm 56.00 Mtr
1.12.2 20 (f) One wire 10.00 sq. mm 91.00 Mtr
1.12.3 20 (g) One wire 16.00 sq. mm 141.00 Mtr
1.12.4 20 (h) One wire 25.00 sq. mm 234.00 Mtr
1.12.5 30 (i) One wire 35.00 sq. mm 298.00 Mtr
1.12.6 30 (k) One wire 70.00 sq. mm 663.00 Mtr
Supplying and erecting Flexible PVC insulated
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
1.13.1 140 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
1.13.2 20 h) 2.50 Sq.mm 3 core round PVC sheathed 77.00 Mtr
1.13.3 30 k) 4.00Sq.mm 4 core round PVC sheathed 175.00 Mtr
Supplying & erecting M.S. Box having
Gauge painted with red oxide or Heavy duty
PVC box erected flushed on wall or concealed
in wall with necessary plastering & finishing as
1.14 directed of following size.
Supplying and laying UPVC cable trunking
system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and
flame proof confirming BS with necessary end
caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories and
1.15 measuring of following sizes
1.15.1 5 (2) 100 mm x 50 mm trunking 424.00 Mtr
(4)100 mm x 50 mm trunking with TWIN
1.15.2 5 compartment With clip in divider 1309.00 Mtr
Supply & installation of surface mounted U
PVC snap-on adaptable trunking raceways,
fabricated out of U-PVC to Off-White or
approved shade as per IS 733 of thickness
2.0mm for the base and sides with all
accessories like removable covers, joints
,height spacer,angles complete with necessary
bends, suitable sized junction boxes and tees
1.16 etc, Complete.
(a)Size: 50x80mm PVC Raceways for Power &
Data with 2 compartments above
5 specifications. 1052.00 Mtr
Supply & installation of modular type
accessories for U PVC snap-on adaptable
trunking/Pop up Box with required items erected
with necessary connection. As desired by
1.17 Engineer In charge
1.17.1 1 i) 6 A SP 1 Way Switch 204.00 No
1.17.2 1 ii) 16A SP 1 Way Switch 351.00 No
1.17.3 1 iv) 6A universal socket shuttered 347.00 No
1.17.4 1 iv) 6/16 A universal socket shuttered 458.00 No
1.17.5 1 vi) Cat-6 LAN Socket 561.00 No
SUB - TOTAL OF INTERNAL WIRING
2 Switchgears , Panels , MCBDBs & MCBs
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 50 KA and above at
415 V having Normal current rating 400A. with
variable Thermal & magnetic release suitable to
work on A.C.supply 50 c/s. With all internal
connections, spreader tinned copper &
2.1 complete erected in existing 16 G.M.S. housing.
1 ICS=100% of ICU only 24979.00 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. and above at
415 V . having normal current rating 250A.
with variable thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned copper &
2.2 complete erected in existing 16 G.M.S. housing.
1 ICS=100% of ICU only 24979.00 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 35 KA. at 415 V.
having Normal current rating 200A.with variable
Thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
2.3 existing 16 G.M.S.housing
1 ICS=100% of ICU only 16061.00 No
providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of
moulded case circuit breaker having CT ratio &
MCCB rating as following along with shunt trip
220V AC. with all internal connections &
2.4 complete erected in existing M.S.housing..
Providing and erecting busbar chamber
confirming to IS-375 fabricated from 16 G.M.S.
sheet, dust & vermin proof having hinged door
with rubber gasket and necessary busbar
supports with COPPER busbar having current
density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with
colour insulation tape for phase sequence,
three phase & neutral each suitable for
following current capacity with necessary
painting mounted on wall or pedestal frame of
2.5 required size with necessary connections.
1 (D) Suitable for 400 Amp. capacity 10239.00 No
Fabricating the box type items made from M.S.
Sheet with A.I. supports, wings, doors, handles
other hardware materials as per requirement
design with finishing by three tank powder
coating processed inside and outside painted,
erected as directed including minor civil work. to
2.6 25 install above MCCB. 179.00 Kg
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type, wall / Floor mounted LT panel
suitable for 415 V 3 phase, 4 wire 50 Hz AC
supply system fabricated in compartmentised
design from CRCA sheet steel of 2 mm thick for
frame work ,Doors and partitions IP 42 and
covers,3 mm thick for gland plates i/c cleaning
and finishing complete 9 tank process in house
facility for powder coating in approved shade,
extendable type FP aluminium alloy busbars of
high condectivity, DMC/SMC busbar supports,
entire panel shall have a common copper
earthbar of size 25mm X 5 mm / 50 x 6 Al at the
rear with 2 Nos. earth studs, solid connection
from main busbar to switchgears with require
size of aluminium busbar & control wiring with
1.5 sqmm FRLS insulated copper conductor
cable, cable alleys, cable gland plates i/c
accessrories as per specification and providing
switchgears, metering instruments etc. for
following panel.G.A.Drawing to be approved by
EIC or consultant. ( Outgoing connectors must
be nut-bolt type. Outgoing mains for 63Amp
MCBs must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be
2.7 always from the busbars.
( a ) Providing cable clamps / supports within
distribution boards cable alley.
( b ) All hinged door shall be earthed through
2.5 sq mm tinned b raided copper wire.
( c ) Pad locking of MCCB’s handles in “OFF”
( d ) All the C.T.s should be auto short link type.
( e ) All the MCCB's should be with rotary
( f ) All incoming and outgoing air circuit
breakers shall be placed on middle portion of
the vertical in single tier formation.
( g ) Any descripancy found in SLD & Boq , it
should be brought in the notice of the client /
consultant, and the decision will be taken final
by Client / consultant.
2.7.1 1 Main POWER DISTRIBUTION BOARD 147855.00 No
A. Incoming Feeder:-
(i) 1 Nos. of 200 Amps, 415V, 35kA, FP MCCB
with Thermal magnetic Based releases having
O/C & S/C along with following
(ii)LED type Indicating Lamp with suitable rating
2A SP MCB:- 2 Sets (each set comprise of
(iii) Digital type 3 phase Multi function Meter
with suitable rating of MCB & 3 Nos. of single
core epoxy resin cast type CTs of 150 /5 Amps,
15 VA, CL 1.0 ratings, , C.T. Short Terminal
with end plate 6nos, Neutral link 2 nos.
200 Amps, 415 V, FP Aluminium Busbars with
Heat shrinkable color code insulation sleeves.
( a ) 7 nos. of 63Amps ,10kA, FPMCB " C "
( b ) 7 nos. of 40Amps ,10kA, FPMCB " C "
( c ) 2 nos. of 40Amp ,10kA DPMCB " C " curve
( d ) 1 No. 25A DP MCB,10kA
( e ) 1 no. 80A TP MCB,25kA
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type,25KVAR, Voltage Rating 415V
A.C.,3-Phase , APFC Panel having 5-steps ( 2-
3-5--5-10 kvar heavy duty can type capacitors )
with suitable rating of Incomer MCB, CT. as per
2.7.2 1 approved by engineer incharge. 113660.00 No
Supplying & erecting approved make IP
grade Company fabricated Timer Panel of
following capacity for switch On-Off street lights
on time scheduling basis made from 16G CRCA
sheet duly epoxy power painted inside and
outside with hinged doors and locking
arrangement consisting of suitable size of
Pole MCB and 4 pole contactor (cat-III)with
analog time switch, auto manual switch of same
make and suitable input and output Bakelite
terminals and with door earthing approved by
2.7.3 Engineer in charge.
MCBDBs and MCBs
providing and erecting Miniature circuit breaker
single pole 6A to 25A suitable to operate on
V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to
2.8 190 IS 8828/1996 with ISI Mark 111.00 E.a.
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to
IS : 8828 in existing box having following
Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in
2.1 existing box having following capacity
Sheets steel powder coated enclosure suitable
2.11 4 for incorporating One/Two nos. MCB. 175.00 E.a.
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be
used of same company of MCB to be used)
(A) single phase incoming and horizontal single
2.12 phase outgoing
(b) sheet steel double door (IP-43)
2.12.1 4 (i)4 way ( concealed manner ) 747.60 E.a.
2.12.3 1 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.12.5 2 (iv)12 way ( concealed manner ) 1773.60 E.a.
(B) three phase incoming and single phase
horizontal type outgoing Per phase isolation
2.13 type (PPI)
(b) sheet steel double door
2.13.1 2 (i)4 way ( concealed manner ) 2779.20 E.a.
2.13.3 2 (ii)6 way ( concealed manner ) 3462.00 E.a.
2.13.5 9 (iii)8 way ( concealed manner ) 4054.80 E.a.
Supplying & erecting Sheet Steel powder
coated Cable end termination Box to be
mounted on Top or Bottom of the MCB
Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of
2.14 MCB DB Box.
2.14.1 16 (G) Three Phase 8 Way ( concealed manner ) 819.60 E.a.
2.14.2 2 (G) Three Phase 8 Way 683.00 E.a.
providing and erecting Approved make ELCBs /
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on
single phase 240 V,50Hz. having characteristic
of quick action & tripping with all advance
feature & do not incorporate any electronic
component. for following Max. rating erected as
Providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity
of 30 mA and Short Circuit withstand capacity of
10 KA and suitable for operation on 3 phase
and neutral 415V,50Hz. having characteristic of
quick action & tripping with all advance feature
& do not incorporate any electronic component
2.16 for following Max. rating erected as directed.
1 (ii) 40Amps. FP 2611.00 E.a.
Providing and erecting metallic vitrified danger
notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE
2.17 12 installation to be erected as per IS-2551. 69.00 E.a.
Providing & erecting Medium Voltage Danger
Notice Board sticker as per language suggested
by engineer incharge of standard size as per IS-
SUB - TOTAL OF Switchgears , Panel and
Follow IS code :3043 is the guideline for the
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
3.1 160 using proper clamp. 77.00 KG
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc. using
3.2 12 copper clamp. 787.00 KG
Providing and erecting Annealed bare Copper
3.3 15 wire 8 to 16 SWG. 787.00 KG
Providing and erecting HOT deep Galvanised
3.4 60 iron strip wire 8 to 16 SWG. 77.00 KG
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge
dissipation suitable for following type of
applications with chamber and heavy duty
cover.(approved make OEM has to submit test
certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 W/ meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load
& dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be
capable to retain moisture for long time
3.5 Necessary test report must be submitted.
(a) For Electrical Installation up to 440V in
Length of pipe - 1 Mtr
3.5.1 3 Back filling compound - 1 Nos Bag of 15 Kg. 4546.00 E.a.
(c) For Electrical Installation covering
Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA) i.e
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
3.5.2 2 Back filling Compound :2 nos Bags of 25 Kg. 8551.00 E.a.
Supply, installation,testing and commissioning
of Chemical Earthing with UL Certified 17.2mm
Dia. X 3000mm Long 254 Micron-Copper
bonded M.S. Rod manufactured as per IEC
62561-2 with 25Kg Bentonite powder plus " U
" bolt rod clamp complete with Lockable high
performence chamber suitable & tested for
3.6 1 5000T capacity with SS Hardware.or equivalent 12230.00 No
SUB - TOTAL OF Earthing
CABLES, Cable Termination and cable
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
4.1 following size of cables
(A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2
(B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
4.2 following size of cables
4.2.1 50 (a) 4 core 4 Sq. mm 116.00 Mtr
4.2.2 250 (b) 4 core 6 Sq. mm 125.00 Mtr
Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
4.3 following size of cables
4.3.1 85 (d) 4 core 16 Sq. mm 152.00 Mtr
4.3.2 25 (e) 4 core 25 Sq. mm 189.00 Mtr
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be
4.4 erected as directed of following size.
4.4.1 50 (G) 3 core 6 Sq. mm 290.00 Mtr
4.4.2 15 (H) 3 core 10 Sq. mm 439.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
at road crossing or floor of following size of
4.5.2 30 (B) 4 core 4 Sq. mm 361.00 Mtr
4.5.3 55 (C) 4 core 6 Sq. mm 505.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
4.6 crossing or floor of following size of cables.
60 (C) 4 core 10 Sq. mm 670.00 Mtr
Making trench in soft soil of suitable width of
cm deep for laying cable or locating the fault all
over the run and back filling the same and
4.7 190 making the surface as normal ground. 55.00 Mtr
Covering of cable with second class bricks or
cement tiles laid cover the cable crosswise &
also on both sides with covering of 7. 5 Cm.
layer of sand above & below cable (16 bricks
4.8 20 per meter) 139.00 Mtr
( A )Making trench in Hard Murrum / Tar Road
of suitable width of 90 cm or required depth for
laying any size of cable or locating the fault all
over the run and back filling the same and
4.9 5 making the surface as normal ground. 74.00 Mtr
(B) If additional machinery like hammer driller or
4.10 5 JCB use [Add] 354.00 Mtr
Drilling the road without breaking the road
surface (Asphalt) for laying of cable for feeding
power supply by making up to following size of
4.11 holes at both ends complete.
4.11.1 10 (A) Up to 100 mm bore dia 488.00 Mtr
4.11.2 10 (B) Up to 150 mm bore dia 610.00 Mtr
Supplying following size of Light duty “A” Class
G.I . Pipe & erecting as directed by Engineer-
4.12 in-charge.
20 (A) 25 mm dia 171.00 Mtr
Providing & laying. R.C.C. Hume pipe for cable
to be laid 90 cm. below ground across the road
crossing or on floor with necessary material in
an approved manner and making the ground as
4.13 per original.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface
4.14 for enclosing cable
4.14.1 90 (A)50 mm outer dia 62.00 Mtr
4.14.2 240 (B)63mm outer dia 73.00 Mtr
4.14.3 20 (C))90 mm outer dia 95.00 Mtr
4.14.4 35 (D)120 mm outer dia. 136.00 Mtr
Providing & laying approved make ISI marked
Rigid PVC pipe having 6Kg / cm2 (Class-3) to
be erected at road crossing on or floor as
directed for laying of cable. The pipes as
4.15 following size of dia & weight per 6 mtr.
4.15.1 10 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124.00 Mtr
4.15.2 10 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234.00 Mtr
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
4.16 of cables.
Providing and, fixing heavy duty flange type
brass double compression type cable gland
with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating
4.17 tape etc for following size of cables.
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
SUB - TOTAL OF Cables,Cable Terminations
& Cable Trenches
5 Light Fixtures & Fans
Supply , Installation, testing and commissioning
of pre-wired, LED fitting/post top luminaries etc
of all types, complete with all accessories and
tube etc. directly on ceiling/ wall, including
connection with 1.5 sq. mm FRLS PVC
insulated, flexible, copper conductor, single
core cable with flexible conduits and coupler
and earthing etc. as required. Note:- The LED
Light fixtures should comply all international
standards third party ( LM 79 for complete
fixture, LM 80 for individual LED ). The
Manufacturer / Channel Partner of the
Manufacturer has to submit 4- Years
unconditional free Replacement Guarantee for
complete fixture.
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. &
corrosion resistance with diffuser with
company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,CCT
K to 6500K, Luminaire efficacy> 85 lumens/watt
, LED driver efficiency > 85 %( fitting required
LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the
5.1 ranges shown.)
( A ) Tube Light with integral / non integral
(iii) 18-20 Watts, Surge - 2KV,IP-20,
5.1.1a 2 conventional 4 feet 293.00 No
(v) 36-40 Watts, Surge-2 KV, IP-20,
5.1.1b 60 conventional 4 feet 530.00 No
(B) LED Panel Light with provision for Plane
front frame with translucent cover fixed to
housing complete.IP20. Round /Square
5.1.2 Recessed or Surface mounted.
5.1.2a 4 (a)up to 8 Watts,4" x 4", Surge-2 KV 271.00 No
5.1.2b 125 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462.00 No
5.1.2c 45 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607.00 No
5.1.2d 30 (vi) 36 watts, 24" x 24", Surge- 2KV 1777.00 no
5.1.3 (F) Spot Light 425 Lumens, Surge-2KV
5.1.3a 10 (a) 3 to 7 Watts 805.00 No
(H) Mirror Light 9 Watts, wall mounted minimum
5.1.4 10 1 feet long 309.00 No
Providing and erecting PVC body surface or
pendent mounting LED Bulk type 9 watt
Lighting Fitting with electronic driver. And lumen
output from luminaire 720lm , input voltage
range 90-300VAC , 50Hz cool white(3000 to
6500k), inbuilt driver, -20degC to +60degC
working temperature, AL frame with Beam
5.2 40 Angle 120deg 780.00 No
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having
3blades with aluminium blades with , canopy &
30 cm. down rod erected with earthing.(Make
5.3 75 shall be approved by Engineer in charge)) 1929.00 No
Supplying & erecting approved make low noise
decorative exhaust fan having size 200mm with
1350 RPM with square frame ABS body with
5.4 42 inbuilt lowers & square frame. 1687.00 No
Supplying & erecting fan hook box of 10 mm
M.S. round bar bounded to the RCC bars up to
50mm length each side and pierced through a
16 Gauge M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling with
5.5 75 necessary finishing. 107.00 No
Providing 2.5mm.thick laminated acrylic sheet
5.6 75 to cover the fan hook or Fan box. 18.00 No
Supplying and erecting 19 / 20 mm. nominal
bore Medium Class M.S. Pipe down rod erected
duly painted for fan complete with proper
5.7 75 insulation without leakage and earthing. 107.00 Mtr
Supplying & erecting single phase approved
make industrial exhaust fan suitable for medium
duty ring mounted low noise operation suitable
for medium duty having following dia size and
5.8 maximum speed in RPM
2 [D] 450 mm dia 900 RPM 3306.00 No
Providing suitable M.S. louver shutter of the
5.9 2 Exhaust fan. 365.00 No
Supplying & erecting electro galvanised G.I.
wire micro mesh jali cover of grade
required size with suitable wooden frame duly
fitted in wall outside of exhaust fan for insect
5.1 2 protection. 628.00 Sqmtr
SUB - TOTAL OF Light Fixtures & Fans
6 External lighting
Supply , Installation, testing and commissioning
of pre-wired, LED fitting /post top luminaries etc
of all typesof external lights, complete with all
accessories and tube etc. directly on pole / pole
bracket , including connection with 1.5 / 2.5 sq.
mm FRLS PVC insulated,3 core flexible,
copper conductor, with flexible conduits and
coupler and earthing etc. as required.
Supplying and erecting LED street light / Flood
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
6.1 wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV
/5000K integral and 10 kv non integral ,Light
must have 440VAC line supply protection. It
should withstand 48 hours for 440VAC line
14 (f) Above 60 watts to 90 watts ( Required 72w ) 5917.00 No
(B) Flood Light (IP-65), Surge -4KV/5000K
,Light must have 440VAC line supply protection.
It should withstand 48 hours for 440VAC line
6.1.2.a 4 (c) Above 60 watts to 90 watts 6028.00 No
6.1.2.b 4 (v) above 120 to 160 watts 8370.00 No
Supply of approved make frp/grp pole having
followiing specifications :
FRP/GRP pole made by centrifugal moulding
process using thermoset resin polyester/epoxy
resin system having minimum glass content
45.0%.The pole should be in one pieceand
tapered round in shape,having smooth outside
surface finish and should be totally fre from
corrosion as well as non conductive and shock
proof. Pole should be provided with FRP/GRP
base bracket dully fabricated from metal(M.S)
and dully claded with FRP/GRP material to
avoid any metal exposer and painted with PU
Pole should mechanical properties i.e 1. Specfic
gravity (ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass
Content % by weight (ASTM D 2584) 45.0 ‐
55.0%, 3. Water absorption (ASTM D 570)
<0.5%, 4. Tensile Strength(ASTM D 638)
200+/‐50Mpa, 5. Flexural strength (ASTM D
790) 250+/‐50Mpa, 6. Compressive Strength
(ASTM D 695) 200+/‐50MPa, 7. Yeild
6.2 Strength(ASTM D638) 250 +/‐50MPa.
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance and
pigmented. Pole should be painted with first
coat of epoxy primer and then two coat of highly
weather resistance polyurethen paint to ensure
proper addhesion of the paint.Minimum
thickness shall be 80 to 100 micron.Defelection
of the pole shall not exceed more than 10.0 %
of the length of the pole for the given load.Pole
should be generally made as per the
dimensional data,performance criteria and
some interchagebility features of poles as per
the standard ANSI C123.20 latest version of
ASTM D 923/01 including cable termination box
with necessory accessories.The size of pole
and type of installation with foundation , Anchor
Base & Internal junction box as per the
manufacturer details and site requirement . The
cost of 6 Mtr & 10 Mtr pole's Flood light
mounting ring is included.
(3) 'B' class (Heavy Duty) frp/grp pole suitable
for base plate mounting
[D] Overall Length of 6.0 meter, Average
thickness : 7mm, Top/Bottom Outside Dia.
76/176mm +/‐2.Weight of Pole 25.0 Kg approx.
(Without base) Metal Anchor Base dully frp
claded (Size : 340 Ø * 12mmthk , Mounting hole
10 PCD 285mm * 6 nos. of 20 Ø hole) 16815.00 E.a.
Providing FRP/GRP arm bracket of having 15˚
arm with 50 mm OD pipe *5 mm thk,1000mm
6.3 long from pole centre
6.3.1 9 (a) Single arm bracket 1882.00 No
6.3.2 1 (b) Double arm bracket 2390.00 No
Supplying & erecting sintex make SMC press
moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with bakelite
connector strip 4way & hinged doors having
locking arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on
6.4 2 wall ( c)150mm x 125mm x 100mm [deep]. 472.00 No
Providing cement concrete.for foundation or for
concrete filling in 1:2:4 ratio with 20 to 25 mm
stone metal duly plastered with necessary
6.5 5 curing for pole muffing or any other purpose. 5077.00 CU Mtr
B' class galvanised iron pipe 32 mm outside dia
45 cms long duly welded on 20 cms x 20 cms x
3 mm thick M.S. base plate, erected on wall or
corner for mounting street light luminaire with
6.6 4 necessary hardware materials duly painted. 340.00 No
SUB - TOTAL OF External Lighting
Supplying & erecting approved make Automatic
liquid level controller 6A. with sensor testing as
per instruction of Engineer in charge on site
complete with wiring connection with existing
wires , with copper conductor from pump to
7.1 1 upper and lower tank. 2332.00 Job
Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
90 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
7.3 dia of pipes, in approved manner as directed .
Providing & erecting water cooler having
storage capacity 150 Ltr. & cooling capacity
Ltr.per hour @ an ambient temp of 45˚ C. The
outlet temp. of the water should drop by 15˚C
within a hour, The water cooler should be
comprising of hermetically sealed compressor,
fan motor, condensing unit, water tank
surrounded by evaporating, coil, thermostats,
relay etc.complete with necessary inlet & outlet
connection. The body of water cooler will be
7.4 4 made from Stainless Steel. 55340.00 No
Supplying and erecting water filter cum purifier
with ultra violate technology. (Aquaguard /
waterdoc model or equivalent symphony/
7.5 4 crystal/videocon model) 5371.00 No
Providing & erecting open well horizontal mono
block pump set with cast iron body, complete
7.6 for three phase submersible motor having
[D] For 5 HP 3 phase open well horizontal mono
block pump set suitable for 1350 LPM to
LPM @ 10 to 42 Mtr head suitable for 50/65
7.6.1 1 mm dia delivery pipe 18561.00 No
[C] For 3 HP 3 phase open well horizontal mono
block pump set suitable for 85 LPM to 270 LPM
@ 11 mtr to 33 mtr head suitable for 50/65 mm
7.6.2 2 dia delivery pipe 15552.00 No
Supplying & erecting approved make motor
control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder
painted inside and outside with hinged doors
and locking, arrangement consisting of suitable
size of ON- OFF isolator (AC - 3/23duty) main
fuses, single phasing preventer, indicating
lamps for R- Y - B phases, overload relay,
Automatic water level controller, Ammeter,
Voltmeter each with two way selector switch
incoming, wires duly socket crimped, main
contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame
grouted on wall as directed. The isolator,
overload relay & contactors will be of L & T,
7.7 Siemens or BCH make only.
2 (a) DOL up to 5.0 H.P. 7646.00 No
Charges for doing liasioning work for obtaining
the necessary clearances from the Electrical
inspector / competent Authorities for the total
Electrical installation,co-ordinating with various
agencies. All necessary drawings, calculations,
test certificates, etc. as required by these
authorities shall be prepared and furnished by
the EPC Vendor. Any modification/rectification
as required by these authorities shall be carried
out by theEPC Vendor at free of cost. The fees
required to be paid to these authorities for
inspection shall be borne by Owner on
7.8 1 production of documentary evidences. 38135.59 No
Supplying and erecting approved make online
Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT
base rectifier & Inverter & sealed maintenance
free SMF batteries. The charger having
operating capacity for input 160-270V AC &
inverter having output 230V,50 Hz Ac with
load power factor with battery, over/under
voltage output with over load & short circuit
protection equipment. The system housed in
CRC sheet duly powder coated paint with
following power backup.with MS painted
batteries stand, 10% Overload capacity for
momentary load.
7.9 1 (D) 5 KVA with 1Hr Backup 128815.00 No
Supplying and erecting horizontal / vertical
mounting type storage water heater with copper
container housed in M.S./S.S./ABS body
insulated with glass wool/puff complete with
heating elements,adjustable thermostats 300C
to 850C, indicating lamp, safety valve, fusible
plug, etc.complete erected with coach bolts,
nuts. washers & cementation
(D)35 ltr.with 1.5/2 KW. heating element
7.1 8 Premium category 12310.00 No
Providing & erecting fibre reinforced PVC
flexible pipe with brass locking nuts & washers
& clips at both ends complete erected without
7.11 16 leakage 180.00 No
Supply,installation,testing and commissioning of
125kVA 3-Phase Oil cooled servo controlled
voltage stabilizer suitable for 3 Phase
unbalanced Load (100% unbalanced load ) with
individual phase voltage correction , indoor
type having input 3-Phase 4 Wire,Output 3-
Phase 4 Wire, as per IS 9815 ( PART-1)1994,
Input Voltage Range 340V-480V,Input
regulation range will shift accordingly,Nominal
output Voltage 415V ± 1% Output voltage can
be changed to 380V/400V,Input Frequency
Range 47Hz to 53Hz,Duty cycle 100%
continous,Waveform distortion Nil,Micr
controller based True RMS sensing and
correction,Provided suitable RC Network, Triac
based drive for AC step synchronous
motor,Ambient Temp. range 0-55 Degree
celcius, Relative Humidity 95% non
dripping,Under and over voltage cut
offs,suitable ratings of OP COS provided for
stabilizer bypass,suitable ratings of IP MCCB
provided for short Circuit protection,Single
phasing prevention and Phase reversal Trip,
Transient suppression,Manual/Auto operation
provided with programmable time delay default
setting 15secs,can also be set for 3 minutes,
Line LCD Displays Input and output voltages (
Line and Phase ),Neutral -Earth Voltage,Output
currents,Frequency,Fault annunciation,Non
latching LED Lamps for Output ON& OP
ON,Bolted terminations up to 100KVA , Busbar
terminals for Ratings>= 125KVA Transformer
Oil Grade 40kVA confirming to IS335 , Busbars
Terminations provided IP & OP
Cables,Provided CRCA sheet cabinet
fabricatedfree standing floor mounting with oil
cooled Tank is Hot rolled steel on castor Wheel
7.12 1 type dust and vermin proof closed cabinet. 453462.00 No
SUB - TOTAL OF MISC. Work
8 PASSENGERS ELEVATOR
Supply ,installing , commissioning and testing
of M.R.L. Passengers Elevator 8 to
passengers as per R & B S.O.R ( Category -
Premium ) having following specifications:-
Ground+ 4 upper floor
Supplying, Erecting, Testing & Commissioning
the passenger lift having following main
[1] GEAR LESS LIFT DRIVE comprising of High
Starting torque Lift 3 phase 440 V
A. C. Permanent Magnet Synchronous motor of
proper rating with high efficiency shall be used.
[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car and
door operation which shall be full collective
selective operation hall call demand response,
UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal
relay and safety controls.
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for
steel and side panels of Stainless steel of sheet
of grade 304 duty. Car ceiling will be S.S.
finishes with aesthetic appearance with LED
ceiling lights. Car flooring shall be of anti skid
PVC with choice of colour of engineer in
charge. Car doors shall be of stainless steel
grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also
be S.S. 304 finished with emergency stop
device, mechanical door safety device, facility
of auto/ attended mode. All car panel buttons
and all floor switches must be with brail
language as per lift act.
[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/
telescopic opening made of hairline finish steel
grade of 304 with key holes and infrared
curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should
start immediately without any Time Delay as
soon as power fails.
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing
over loading shall be provided such that doors
kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall
be provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit
should be provided by the lift agency, along with
the other steel structure works, foundations for
the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in charge.
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in
circuit for lift machine room and lift well with
proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided
by the agency. Only 3 phase Power Supply
shall be made available by department in lift
machine room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related
to erection of lift shall be made by lift agency
without any extra cost. (granite/marble fixing
around all landing door openings are not in lift
agency’s scope.)
[19] Agency has to provide all working drawings
and documents and liaison services for
obtaining all necessary permission from lift
inspector and other authorities.
[20] acrylic transparent licence/display A4 size
holder in lift car
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
authority 5.agency has to provide third
party insurance upto completion of free
maintenance period and submit the document
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade of
304 should be provided at appropriate height
on the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which rating
is sugested by CEICED Department (electrical
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS Serial
Communication mode including Regenerative
power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS
with necessary online real time monitoring
system having necessary connectivity for
remote monitoring & other suitable supporting
hardware & software devices to fulfil the
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and
hall lantern & TFT Screen in the car with MP3
Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have
fire rating up to 2 hours and car door must have
multi-level crisscross beam door protection.
4. To & fro communication system & wiring (i.e.
car , control room & guard room ) and Each
elevator are equipped with remote monitoring
system.agency has to provide mobile app and
user id and password for monitoring
8/10 passengers Ground + 4 upper floors with
Rated Speed of 1.0 m/sec -
(C) With General PLUS ADDITIONAL SPECIAL
8.1 1 FEATURES attached herewith. Prem. Cat. 1659857.00 No
SUB TOTAL of Passengers Elevator
TOTAL OF Electrical, ELV system and
Passenger Elevators
Annual Comprehensive Maintenance of the
Electrical /ELV / passenger elevators for
9 Year after completion of DLP ( 1-Years)
Annual comrehensive maintenance charges for
1-Year of DLP + 4 year for Entire Electrical and
ELV system and passenger elevators installed
at site including with all genunine spares from
OEM, Annual comprehensive maintenance
period starts after completion of Defect Liability
period of project. Payment for Annual
Comprehensive Maintenance shall be made on
quarterly basis & after completion of each
quarter For the Executed Tender Items by
Considering Tender Rate. No Price Variation
shall be Given For Any Item. quarter.
9.1 1 DLP-1 Year Free Job
Annual comprehensive maintenance Charges
for First year After Guarentee / Defect Liability
9.2 1 Period @ 2.5% of Electrical Work Amount 131968.96 Job
Annual comprehensive maintenance Charges
for Second year After Guarentee / Defect
Liability Period @ 2.5% of Electrical Work
9.3 1 Amount 131968.96 Job
Annual comprehensive maintenance Charges
for Third year After Guarentee / Defect Liability
9.4 1 Period @ 2.5% of Electrical Work Amount 131968.96 Job
Annual comprehensive maintenance Charges
for Fourth year After Guarentee / Defect Liability
9.5 1 Period @ 2.5% of Electrical Work Amount 131968.96 Job
TOTAL OF Annual comprehensive
MAINTENANCE CONTRACT of Electrical,
ELV system and passenger elevators
I. No. Qty Items Unit Rate Per Amount
FIRE FIGHTING SYSTEM
Design,Drawing, Supply,installing,testing
and commissioning of FIRE HYDRANT
1 Internal / External Hydrant
Supplying, Installation, Testing and
Commissioning of electric driven main Hydrant
fire pump suitable for automatic operation and
consisting of following: complete in all respect
1.1.1 as required.
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical
seal to ensure a minimum pressure of
kg/sq. cm. at highest and farthest outlet at
specified flow of 2280 lpm at 65 Mtr. head
conforming to IS 1520.with suitable size of
footvalve confirming to IS 4038, Pressure rating
PN2 , preventing entry of foreign body to pump
through suction pipe, perfectly flat seating
2 surfaces for good sealing. 230151.00 Set
b) Suitable HP Squirrel cage induction motor,
TEFC, suitable for opertion on 415 volts,
phase 50 Hz. AC with IP 55 class protection for
enclosure, horizontal foot mounted type with
Class - 'F' insulation, conforming to IS-325.
c) M.S. fabricated Common base plate,
coupling, coupling guard, foundation bolts etc.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not less
than 150% discharge at ahead not less than
65% of the rated head.
Supplying, Installation, Testing and
Commissioning of electric driven pressurisation
pump suitable for automatic operation and
consisting of following: complete in all respect
1.1.2 1 as required 61717.00 Set
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze
impeller with stainless steel shaft, mechanical
seal at specified flow of 180 lpm at 56/70 m.
head conforming to IS: 1520.with suitable size
of footvalve confirming to IS 4038, Pressure
rating PN2 , preventing entry of foreign body to
pump through suction pipe, perfectly flat seating
surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor
TEFC type suitable for operation on 415 volts,
phase 50 Hz. AC with IP 55 Class of protection
for enclosure, horizontal foot mounted type with
Class F' insulation, conforming to IS :
c) M.S. fabricated Common base plate, flexible
rubber coupling, coupling guard, foundtion bolts
etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
Supplying, Installation, Testing and
Commissioning of diesel engine driven main fire
pump suitable for automatic operation and
consisting of following: complete in all respect
1 as required 506181.00 Set
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze
impeller with stainless steel shaft, mechanical
seal to ensure a minimum pressure of
kg/sq. cm at highest and farthest outlet at
specified flow of 2280 lpm at 65 m. head
conforming to IS
b) Suitable HP, 1500 /1800 RPM water cooled
with radiator, diesel engine conforming to
relevant BS & IS standard complete with auto
starting mechanism, 12/24 volts electric starting
equipment, 180 AH lead acid battery with
battery stand, exhaust pipe extended upto 6 m.
outside pump house duly insulated with 50 mm
thick glass wool with 1.0 mm. thick aluminium
sheet cladding, residential silencer, instruments
and protection as per specification, stop
solenoid for auto stop in the event of fault with
audio indications, painted with post office red
colour etc. as required.
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates. Tank
shall be provided with inlet, outlet, overflow, air
vent, drain connections, filling connection &
level indicator. Tank shall be mounted on a
suitable steel structure (Painted with 2 coats of
red oxide paint). Tank shall be provided with
two or more coats of synthetic enamel paint
outside over two coats of red oxide primer.
d) M.S. Fabricated Common base plate,
coupling, coupling guard, foundation bolts etc.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.2 FIRE PANELS
FIRE CONTROL PANEL FOR Main Hydrant
pump and Jockey pump and Diesel Engine
1 pump. 341210.00 No
Fabrication, Supplying, Installation, Testing &
Commissioning of electrical control panel of
cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable doors,
dust and vermin proof, powder coated of
approved shade after 7 tank treatement
process, cable alley, inter-connection, having
switchgears and accessories mounting and
internal wiring, earth terminals, numbering etc.
complete in all respect, suitable for main fire
pump, pressurisation pump complete as per
CPWD specification with following in coming
and Outgoings, suitable for operation on 415V,
3 phase, 50Hz Ac Supply with enclosure
protection class IP 42 as required :suitable for
operation on 415 V, 3 phase, 50 HZ, AC supply
with enclosure protection class IP 42 as
A. Incoming Feeder:-
(i) 1 No of 200 A,35KA, 415V,FP MCCB with
Thermalmagnetic Based Releases having O/C,
S/C ,E/F protection, Digital ELR 96x96mm with
CBCT, FP Spreader Terminals 1 set= 8 Pcs,
Extended Rotory Handle for MCCB, 240V AC
Shunt Trip coil for MCCB.
(ii) LED type indicating Lamp with suitable
rating 2 Amp SP MCB:- 1 Set (each set
comprise of R,Y,B)
(iii) Digital type 3 phase Multi function Meter
with suitable rating of MCB & 3 Nos. of single
core epoxy resin cast type CTs of 200/5 Amps,
10 VA, CL 1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium Busbars with
Heat shrinkable color code insulation sleeves.
OUTGOINGS:-( All outgoing feeders for pumps
should have digital Ammeter with selector
switches and LED type ON,OFF,Trip indicating
1 sets - 125 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 50 HP pump with overload
protection, current sensing type single phase
preventor complete with all acceessories and
internal wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 sets - 125 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 50 HP pump with overload
protection, current sensing type single phase
preventor complete with all acceessories and
internal wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 no.63A,16KA MCCB Ics=100%,Extended
Rotry handle with TM release having O/C &
S/C protection with 10 HP fully automatic star/
delta starter , current sensing type, Single
Phase Preventer, ON/OFF Push Button & LED
type Indicating lamps complete with all
accessories and internal wiring required for
automatic operation, selector switch, for
local/remote, auto/manual operation
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt
starting device, timers and relays as required,
push buttons, start/stop in manual mode.
ii) LED type Indication lamp for High/Low Lub.
Oil pressure, High Water Temp and Engine ON
iii) Battery charger suitable for 12 V/24 V DC
with boost and trickle selector switch, 0-30 V
DC volt meter, 0-20 Amp DC Ammeter.
iv) All standard relays, accessories for
automatic operation of diesel engine, wiring with
1.5 sq mm PVC insulated copper wire between
various sensors and system controller / starter,
suitable size cable for battery charging etc. as
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to control
operation of Main Electric Fire Pump, Diesel
Pump, Pressurisation Pump, Terrace Pump in
sequence as per specification consisting of
relays, timers, sensors, annunciation window for
fault indication, control wiring complete as
3 NOS. 25A DP MCB " C " Curve
PRESSURE GAUGES AND PRESSURE
Providing, fixing, testing and commissioning of
1.3.1 3 Pressure Switch with Needle Valve. 1329.87 Set
Providing and fixing in position the industrial
type pressure gauges with gun metal / brass
1.3.2 3 valves complete as required 967.73 Set
Supplying, Installation, Testing and
commissioning of Air vessel fabricated from
10mm MS plate with dished ends,dia of
mm and height 1500 mm with suitable
supporting legs, outside painted with one coat
of primer and two coats of synthetic enamel
paint of approved shade, complete with one
25mm dia connection from pump delivery, one
25 mm drain with valve.Complete as per
1.3.A 1 technical specification & drawing details. 48500.00 No.
Providing, laying, testing & commissioning of 'C'
class heavy duty MS Pipe conforming to IS
1239 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc., in ground
including excavation and providing cement
concrete blocks as support, anticorrosive
treatment with coaltar/asphalt tape as per IS
10221, refilling the trench etc. of following sizes
1.4 complete as required .( For HYDRANT )
60 100MM Dia 2300.63 Mtr
Providing, laying, testing & commissioning of 'C'
class heavy duty MS pipe conforming to IS
3589/IS 1239 including Welding, fittings like
elbows, tees, flanges,tapers, nuts bolts, gaskets
etc. and fixing the pipe on the wall/ceiling with
suitable clamp/support frame and painting with
two or more coats of synthetic enamel paint of
1.5 required shade complete as required :
1.5.9 5 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
Supplying and fixing Single headed internal /
External hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel
coupling and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with blank
Gunmetal/Stainless Steel cap and chain as
9 Single headed Stainless steel 5549.04 No
Providing, fixing, testing and commissioning of
Wall mounting swing type first aid Fire Hose
Reel with drum, hanging bracket, 30 M x 25 mm
dia high pressure hose reel tubing as per IS:884
with shut nozzle and ball valve and all required
1.7 8 accessories. 10499.50 No
Supplying, Installation, Testing and
commissioning of weather proof Fire Hose
cabinet size 900x 600x300mm to house fire
hydrant & hose, including all other related
accessories fabricated from M.S. sheet (16
Gauge) of fully welded construction having front
door with locking arrangement, partially glazed
with 4 mm thick glass. Cabinet shall be powder
1.8 8 coated & painted with post office red colour 4726.50 No
Providing ISI marked RRL (IS : 636, type‐A) fire
hose pipe 15 meter long and 63 mm dia with ISI
marked (IS : 903) Stainless steel male and
female coupling bound and rivetted to hose
pipes with copper rivets and copper wire
1.9 18 complete as required. 4020.55 No
Providing Stainless steel ISI marked 63 mm.
dia. male Instantaneous pattern short branch
pipes with 20 mm dia. Nozzle as per IS :
suitable for 10 Kg/sqcm operating pressure and
suitable for interconnections to hose pipe
1.1 9 coupling as required. 1502.28 No
Supplying and fixing of fire brigade connection
of cast iron body with gun metal male
instantaneous inlet couplings complete with cap
and chain as reqd. for suitable dia MS pipe
1.11 connection conforming to IS
1.11.1 1 2 way - 100 mm dia M.S. Pipe 6094.09 No
1.11.2 1 4 way - 150 mm dia M.S. Pipe 12631.09 No
Providing, fixing, testing and commissioning of
25 mm dia Air Release Valve and Ball Valve
assembly on top of each riser for Air release
1.12 2 system. 1949.25 No
Providing, fixing, testing and commissioning
Pressure Relieaf Valve 25mm dia with Ball
Supplying and fixing orifice plate made out of
mm thick stainless steel (Grade 304) with orifice
of required size to be fitted between flange &
landing valve of external and internal hydrants
to reduce pressure at the outlet to the level of
1.14 9 3.5 kg/cm2 complete as required. 1932.76 No
Supplying, fixing, testing and commissioning of
butterfly valve of PN 1.6 rating with
bronze/gunmetal seat duly ISI marked complete
with nuts, bolts, washers, gaskets conforming to
1.15 IS 13095 of following sizes as required :
Providing, installation, testing and
commissioning of non-return valve of following
sizes confirming to IS:5312 complete with
rubber gasket, GI bolts, nuts,washers etc.as
1.16 required :
Providing, installation, testing and
commissioning of stainless steel Y-strainer
fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia holes with
1.17 stainless steel flange.
Supply, Installation, Testing and Commissioning
of Brass. Ball Valves with all fittings required.
Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
120 f) 1.50 Sq.mm 4 core round PVC sheathed 67.00 Mtr
SITC of fire pump start stop push buttons in
SITC of 4 Zone standalone Fire Alarm
control Panel, 16X2 Character LCD Display,
provision for zone wise contact and sounder.
Panel does not have provision to connect
Repeater Panel. Approval: CE Mark.(Including
1.21 1 Five year free maintenance with guarantee) 12300.00 No
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following
1.22 dia of pipes, in approved manner as directed
Supply, Installation, Testing and Commissioning
of Single action Manual Pull Station.Shock and
Vibration Resistant, pull Down Lever Remains
Down Until Reset. Shall be Polarity Insensitive
(with all mounting accessories , complete with
Junction Box for mooting on Surface, Cable
lugs at Ends, cable compression glands, cable
1.23 5 tags and ferruling. 1201.75 No
Supply, Installation, Testing and Commissioning
of Conventional Sounder cum strobe having
tone settings with range of 95dbA and field
selectable 15/30/75/110 candelas.(with all
mounting accessories , complete with Junction
Box for mooting on surface, cable lugs at ends,
cable compression glands, cable tags and
1.24 5 Ferruling.) 1201.75 No
CABLES AND TERMINATIONS
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
1.25 crossing or floor of following size of cable.
1.25.1 36 (B) 3 core 4 Sq. mm 285.00 Mtr
1.25.2 5 (G) 3 core 6 Sq. mm 392.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
1.26 crossing or floor of following size of cable.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
1.27 crossing or floor of following size of cables.
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out
going tails, insulating tape etc for following size
1.28 of cables.
1.28.2 4 (C) 2 to 4 core 10 Sq. mm 38.00 No
1.28.3 8 (D) 2 to 4 core 16 Sq. mm 47.00 No
Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
Providing and fixing approved make Perforated
C type cable tray. Made from sheet steel. The
cable tray should be single or double bended as
per required and as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like
nut - bolt and washers etc. erection with
necessary support( included) as per
Specification and as per instruction of engineer
1.3 in charge..
Supply, installation,testing and commissioning
of Chemical Earthing with UL Certified 17.2mm
Dia. X 3000mm Long 254 Micron-Copper
bonded M.S. Rod manufactured as per IEC
62561-2 with 25Kg Bentonite powder plus " U
" bolt rod clamp complete with Lockable high
performence chamber suitable & tested for
1.31 1 5000T capacity with SS Hardware.or equivalent 12230.00 E.a.
1.32 SEWAGE PUMPS
Supplying, Installation, Testing and
commissioning Sewage water submersible
pumping sets of CI casing & impeller, SS shaft,
including with inbuilt water level sensors for
operating the pumps automatically and all
accessories suitable for operation on 220 V-240
2 V, single phase, 50 Hz. AC supply etc. as reqd. 19676.50 No
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
Charges of Preparing Design , Drawings
,Testing of Fire Fighting System with necessary
Approval from Local Fire authority.( Including
1.33 1 Pre-NOC and NOC from Fire authority. ) 76271.19 job
Providing, fixing, testing and commissioning of
1.34 below Auto Glow Signages.
1.34.2 8 Fire Equipment: 4" X 12" 514.97 No
In case of Fire, do not use lift, use staircase: 8"
1.34.4 5 Fire Lift 4"X12" 514.97 No
1.34.5 5 Fire Extinguishers 8"x 4" 480.00 No
1.34.6 5 Floor Sign": 4" X 12" 514.97 No
1.34.7 5 Fire Hydrant 4” X 12” 514.97 No
1.34.8 5 Fire Hose Reel.4” X 12” 514.97 No
1.34.9 5 DCP Extinguisher 8"x 4" 480.00 No
1.34.10 5 CO2 Extinguisher 8"X 4" 480.00 No
Providing, fixing, testing & commissioning of
15mm dia quartzoid bulb type sprinklers of
1.35 rating with required accessories :
Pendent Sprinkler 57°C standard response (K-
Pendent Sprinkler 68°C standard response (K-
1.35.2 30 80) UL Listed 471.50 No
Supplying, installation, testing & commissioning
of sprinkler flexible pipe (UL Listed) of stainless
steel complete with 15 NPT on reducer thread
with maximum working pressure of 175 PSI test
pressure of 875 PSI (Burst) with branch line
(Inlet) 25mm NPT male thread to sprinkler head
(Outlet) 15mm NPT female thread with reducer,
nipple, 2 side brackets,center bracket, stockbar
of following sizes complete as required etc of
1.36 following sizes as required:
Providing fixing, testing and commissioning of
Drainning & Testing Assembly 25mm dia with
Sight Glass , Union joint , Ball Valve & Drain
Supplying, Installation, Testing and
commissioning of Flow Switch on sprinkler
distribution header on each floor with necessary
Junction Box and shall be connected to fire
alarm panel through cable. Flow switch shall be
"UL" Listed size 150mm dia/ 100mm dia/ 80mm
Providing, fixing, testing and commissioning of
Sprinkler Alarm valve of cast iron body and
brass/bronze working parts comprising of water
motor alarm, bronze seat clapper, and clapper
arm, hydraulically driven mechanical gong bell
to sound continuous alarm when the sprinkler
system activates,pressure guages, emergancy
releases, strainer, pressure switch, cock valve
complete with drain valve and bypass, test
control box, ball valves, flanges,gasket etc.
Supplying, Installation, Testing and
commissioning of 2 C X 1.5 Sqmm Copper
Armoured for Flow Switch Cabling from
1.4 90 Announciation panel to Flow Switch. 122.88 Mtr.
SUB-TOTAL OF FIRE HYDRANT System
FIRE EXTINGUISHERS AND LIGHTNING
2.1 FIRE EXTINGUISHER
FIRE EXTINGUISHER Supplying, Installation,
Testing and commissioning of Dry Chemical
Powder (DCP) 6 Kg Fire Extinguisher Mono
Ammonium Phosphate Powder 40, Stored
Pressure Type, Pressure Gauge, Controllable
discharge mechanism Class A, Rating 3A &
Class B rating 21B as per IS 15683 ISI MARK
(ABC Dry Chemical Powder - MAP 40%)fitted
with required accessories including wall
2.1.1 5 suspension brackets. 2724.25 No
Supplying, fixing, testing and commissioning of
CO2 type Fire Extinguisher of capacity 4.5 kg
filled with Co2 Gas as per IS 15222 with
controll discharge mechanismfitted with Hose &
Horn applicable on Class B fire rating 21B
confirms to IS 15683, bearing ISI mark. Co2
2.1.2 5 Cylinder as per IS 7285. 6526.00 No
Providing & fixing of ISI marked water CO2 type
Portable fire extingusher,9 LTR capacity,
Hydraulic test pressure 35Kgf/ cm2, Discharge
range 2 Mtr,Average discharge time: Min.
2.1.3 2 13Sec,Fire Rating 3A,Grade: IS:15683. 3450.00 No
Providing & fixing of ISI marked, Squeeze Grip
Cartridge Type water CO2 type Portable fire
extingusher,9 LTR capacity, Hydraulic test
pressure 35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min. 13Sec,Fire
2.1.4 1 Rating 3A,Grade: IS:15683. 4200.00 No
Providing,fixing, testing and commissioning of
10Kg Modular type fire extinguisher having
Nitrogen expellant ,ceiling mounted,Sprinkler
Nozzle is gas tight the release temperature is
adjusted with sprinkler imported bulb set at
57 degree C or 68 degree C ,coverage area
2.1.5 1 to 5 sqmtr, 2950.00 No
2.2 LIGHTNING ARRESTER
SITC of Vertical Air Termination Solid
aluminium with Base- 10 mm dia and 1000 mm
long. Air Termination Base tested for
conditioning, Ageing Test & Lightning impulse
current withstand test: 100 kA of 10/350µs
waveform in an accredited Third party
laboratory as per 6.3 & 6.4 of IEC 62561-1
protocol with MAST 34mm dia 3000 mm long-
2.2.1 5 Cold Galvanized 9323.00 No
SITC of 8 mm dia solid Aluminium Conductor
for roof top mesh grid and tested as per IEC
62561- 2 conducted in the Govt. accredited
thirty party laboratory to meet the requirement
of IS/IEC 62305 with Required Accessories -
Aluminium Holding clamp at every 1 mtr
distance, Aluminium/SS cross splicer at every
crossing of Alu. conductor, Expansion piece
with connectors at every 20 mtr distance,
Aluminium straight Splicer to connect
conductors. All Accessories should be tested
as per IEC 62561-1 2018 Cl. 6.3 for
conditioning & Ageing Test & 6.4 for Lightning
impulse current withstand test: 100 kA of
10/350µs waveform(Ageing & Electrical test )
conducted in a sequence manner & tested in
the Govt. accredited Third party laboratory to
2.2.2 100 meet the requirements of IS/IEC 6230 297.00 Mtr
SITC of Galvanized Steel Flat 25x6 mm
thickness from earth electrode directly in ground
as required. Zinc coating: 500 g/m square
(Approx:70 micron coating) tested and used
exclusively for lightning protection earthing
2.2.3 125 system and ring equipotential bonding. 153.00 Mtr
SITC of 14.2 mm dia 3 mtr long Earth electrode
of High tensile steel electrode with 250 micron
copper bonding & 1 bag of Carbon fill Based
environment friendly backfill tested as per IEC
62561-7 in NABL accredited Laboratory and
suitable stainless Steel double sided clamp.
Eco Friendly rust proof heavy duty weather
proof Polyethylene Earth Pit Chamber with
following dimensions :254 mm dia (top),
2.2.4 5 mm dia (bottom) & 260 mm (height). 5933.00 No
Heat / FIRE RESISTANT COATING OF
CABLE: Supply and apply intumescent based
coating Hilti 678on cables / bunch cables &
cable tray for at least 1 mtr in every 14 Mtrs for
horizontal runs and to entire length of vertical
runs. The coating shall have a density in the
range of 1.2 to 1.4 Kg / L. The coating shall be
non-toxic, asbestos and halogen free and shall
have good mechanical strength. The coating
shall comply with IEC 332 part 3 (1992). The
product shall carry test certificate for mold
resistance rating of 0 as determined by
ASTMG21-96. The product should have a VOC
content of approx... 60g/l as per LEED
and should not have any de-rating effect on the
cable. Manufacturer should submit relevant
certificates for mentioned attributes. Coating
shall be carried out by approved machine
spraying system which will yield uniform
thickness and better finish. Fire stop installation
shall be done by Hilti Accredited Fire stop
Specialty Contractor (HAFSC) and in
accordance with guidelines. Firestop specialty
Contractor need to submit work completion
certificate along with installation report through
Hilti documentation Software CFS DM for
2.3 20 periodic inspection & maintenance purpose. 3690.00 Kg
FIRE STOP FOAM Hilti CP 620 on both sides
of wall, with minimum 2 Hours fire rating when
tested in accordance with UL 1479 / ASTM-E
814, for horizontal openings in floors or slabs
made of concrete / masonry or Gypsum after
passing service lines like cable trays or cables /
cable bundles. The expanding foam expands
seven times its volume to fill the cavity at the
time of dispensing the material and shall fully
cure within two minutes after dispensing. The
product shall be age tested as per Dafstb and
DIBT Standards. The product shall provide
water tightness when tested for W rating as per
UL standards and shall carry test certificate for
sound insulation of 50 dB when tested in
accordance with ASTM E 90. The product shall
carry test certificate for mold resistance rating
as determined by ASTM G21-96 and shall have
a VOC content of approx... 1.3g/l as per LEED
2009. The product shall be tested in
accordance with IEC 60068-2-57: 1999-11
(Environment Testing) as per Part 2-57: Test for
Vibration-Time –history method and
VERTEQQII for seismic zone 4. The system
shall be UL listed & classified and product shall
bear the UL and FM approval logo on the
packing. If none of UL test certificate comply
with actual application, an EJ document
prepared by a qualified personnel and based on
nearest third party tested & approved systems
like UL test certificates & in accordance with
IFC guidelines shall be produced by
manufacturer. A Fire stop submittal shall be
produced by manufacturer, in accordance with
approved passive fire protection method
statement, for technical approval. Fire stop
installation shall be done by Hilti Accredited Fire
Stop specialty Contractor (HAFSC) and in
accordance with Hilti guidelines and UL system
test certificates along with installation report
through Hilti documentation Software CFC DM
2.4 20 for periodic inspection & maintenance purpose. 4460.00 No
SUB TOTAL of FIRE EXTINGUISER &
Lightning Arrester
3 FIRE DETCTION & FIRE ALARM SYSTEM
Supply, Installation, Testing & Commissioning
of Microprocessor based Networkable Analogue
Addressable Fire Alarm Control Panel. The
Panel shall be compliant with EN54-2, EN54-4
and approved by LPCB. The Fire Alarm Control
Panel shall have inbuilt 2 loops and expandable
capacity upto 8 loops. The Panel must have Full
colour 800 x 480 LCD with resistive touch
screen and automatic backlight dimming. The
Panel must also have the capability to take
Addressable Intelligent Wired and Wireless
Devices on same loop. Each loop shall have a
capacity of 127 analogue Addressable devices
and 127 Base sounders/Base Sounder
3.1 1 Beacons. The panel shall have an event log of 203348.75 No
minimum 10,000 events @ 1 second resolution,
Filterable and Printable. The Panel shall have
Three access levels. Panel shall support upto
5000 Cause & Effects entries, with upto
inputs controlling & 20,000 Controlling outputs
across the network. The Panel shall have
capability for Peer to Peer networking through
RS485 network card. The Panel must have
inbuilt programmable sounder circuits, each
circuit rated at 2.5A.The Panel must have inbuilt
3 programmable inputs and 5 inbuilt
programmable relay outputs. The Panel shall
have up to sub-addressable 512 programmable
Inputs/Outputs via optional RS485 COMMS
serially connected expansion cards. The Panel
shall have 240 V AC power supply along with
automatic Battery Charger. The Panel shall be
fully expandable via common plug in loop driver
boards. The user shall have a choice of using
the panel with 5.25 Amp or 10.25 Amp power
supply unit which is inbuilt in the FACP and
should be approved to EN54-4. The Panel shall
have configurable via USB port to PC or
memory stick. The Panel shall have dedicated
RS232 serial port for optional printer. Approved
SITC of Analogue Addressable Multi- Sensor
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's
allow 360 degree viewing, User selectable
sensitivity modes 1% to 4.5% obs/m,
Incorporate Optical and dual Heat elements,
lock mechanism (sensor to base), Electronically
addressed, Pulsing/non-pulsing controlled from
panel. Approved by LPCB & VdS. (Including
3.2 105 Five year free maintenance with guarantee) 3597.20 No
SITC of Analogue Addressable Multi- Heat
Sensor which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's
allow 360 degree viewing, User selectable
sensitivity modes 0 to 88 degree Celsius,
Incorporates Fixed Temperature and Rate Of
Rise Heat elements, lock mechanism (sensor to
base), Electronically addressed, Pulsing/non-
pulsing controlled from panel. Approved by
LPCB (EN54: Part 5) (Including Five year free
3.3a 22 maintenance with guarantee) 3498.30 No
Supply, Installation, Testing & Commissioning
of Analogue Addressable Single Input Module.
which Includes a single monitored input, flying
leads for easy installation. Electronically
3.3b 5 addressed, Approved by LPCB & Vds. 4290.65 No
Supply, Installation, Testing & Commissioning
of Analogue Addressable Single Output Module
. which Includes a single output, flying leads for
easy installation. Electronically addressed,
3.3c 5 Approved by LPCB & Vds. 4688.55 No
SITC of sensor common mounting base,
includes stainless steel contacts, slim profile -
only 8mm, quick connection via square cable
clamps, facility for remote indicator, Approved
by LPCB (Including Five year free
3.4 125 maintenance with guarantee) 354.20 No
Supply,Instllation,Testing and Commissioning of
Fault isolator Module capable of monitoring
shorted loop circuit and automatically restore
communications when shorted conditions are
corrected (Including Five year free
3.5 12 maintenance with guarantee) 2477.10 No
Supplying, installation, testing & commissioning
of response indicator on surface/recessed MS
Box having two LED, metallic cover complete
3.6 8 with all connections etc as required. 193.20 No
SITC of Manual Call Point approved to EN54-
11:2001, Approved by LPCB Easy to install,
push-fit wiring terminals (Including Five year
3.7 5 free maintenance with guarantee) 4191.75 No
SITC of Analogue addressable loop powered
Base Sounder, variable sound output 50 ~
dB(A) (±2 dB(A)) output at 1 metre, 51 user-
selectable tones (all tones EN54-3 compatible),
Auto shutdown feature prevents noise-pollution,
Approved by LPCB & VdS (Including Five year
3.8 5 free maintenance with guarantee) 7442.80 No
Supplying & laying of 2x 1.5 sqmm fire alarm
armoured cable, 600/1000V rated with
annealed copper conductor having XLPE
insulation, steel wire armouring & FRLS
3.9 1020 outer sheath complete as required. 135.70 Mtr
SUB -TOTAL OF FIRE DETECTION& ALARM
Total of Fire Fighting, Fire Extinguisher, Fire
Detection & Alarm System
Annual Comprehensive Type Maintenance
Contract of for Above Fire Fighting System
For for 4 Year after completion of DLP ( 1-
Annual comrehensive maintenance charges for
1-Year of DLP + 4 year for Entire Fire Fighting,
Fire Extinguisher, Fire Detection & Alarm
System installed at site including with all
genunine spares from OEM, Annual
comprehensive maintenance period starts after
completion of Defect Liability Period of Project.
Payment for Annual Comprehensive
Maintenance shall be made on Quarterly basis
& after completion of each Quarter For the
Executed Tender Items by Considering Tender
Rate. No Price Variation shall be Given For Any
Every six months Testing certificates with
Photographs should be sent to competent
authority by concern contractor.
Annual comprehensive Type Maintenance
Charges only During 1st Year DLP / Defect
4.1 1 Liability period. 0.00 Year
Annual comprehensive Type Maintenance
Charges for 2nd Year after Guarentee / Defect
4.2 1 Liability period. 127224.20 Year
Annual comprehensive Type Maintenance
Charges for 3rd Year after Guarentee / Defect
4.3 1 Liability period. 127224.20 Year
Annual comprehensive Type Maintenance
Charges for 4th Year after Guarentee / Defect
4.4 1 Liability period. 127224.20 Year
Annual comprehensive Type Maintenance
Charges for 5tht Year after Guarentee / Defect
4.5 1 Liability period. 127224.20 Year
TOTAL of Annual Comprehensive
Maintenance of Fire Fighting, Fire
Extinguisher, Fire Detection & Alarm System
I. No. Qty Items Unit Rate Per Amount
LANDSCAPING WORK :
LAYING OUT LAWN – After excavating soil
upto 30 cm. depth & removing unwanted stuff,
stones etc. Preparing soil for planting by
supplying and mixing 6 inch river fine site and
0.5 cmt FYM maximum 100 sqmt of lawn area
and doing termicide @ 1 fit / 100 sqmt area and
planting selection 1 type / approved lawn grass
at maximum 6 cm x 6 cm distance and maintain
it upto 120 days. Maintainance include all
operations i.e. watering, grass cutting, gap
1 200 filling, applying of fertizer if require etc. 85.00 Sq.mt.
Supplying, Spreading and leveling of good earth
2 60 like firtile soil as directed etc compt. 575.00 Cmt.
Supplying, Spreading and leveling of good
quality river Kap Filling 100 mm as directed etc
3 20 comp. 575.00 Cmt.
Supply and Planting saplings of Hedge plants
like kadvi mahendi, karmda, dyuranta,
nikodeviya etc. specifies bag size is 4 inch x
inch, well established & free from disease at
4 100 site. as per the instructions 15.00 Nos
Supply and Planting saplings of Ficus panda,
Ficus benjamina, Ficus benjamina variegated,
Ficus longisland bag size is 13 inch x 13 inch,
well branched, well established & free from
5 100 disease at site as per the instructions 150.00 Nos
Supply and Planting saplings of (Jasud, Ixora,
Ticoma Gaudi-chaudi, Gultora, Jetropha,
Haemeliya, Chandani, Mogaro, Galfemia,
Allamenda, Desi Gulab, Euphorbia mili, Jasud
Hybrid, Chandani double, Madhukamini,
Madhumalti, Ticoma Capensis, Ixora draft,
Nikadevia, English Karen etc.) having height of
minimum 2.00 to 2.5 ft. and bag size is 8 inch x
10 inch, well branched, well established & free
6 100 from disease at site as per the instructions. 85.00 Nos
Supply and Planting saplings of Golden
Bamboo having height of minimum 5 to 6 ft.
and bag size is 8 inch x 10 inch, well branched,
well established & free from disease at site as
7 30 per the instructions. 45.00 Nos
Supply and Planting saplings of Palm(Botal
palm,foxtel) having height of minimum 10.00 to
12.00 ft. and bag size is 21 inch x 21 inch, well
branched, well established & free from disease
8 50 at site as per the instructions 3500.00 Nos
Supply and Planting saplings of champa
(deshi) having height of minimum 8 to 10 ft.
and bag size is 15 inch x 16 inch, well
branched, well established & free from disease
9 80 at site as per the instructions. 450.00 Nos
Supply, Spreading and leveling of Brick dust
10 5 (Chharu) particle size having maximum 10 mm 1300.00 Cmt
Supply Saplings and Planting of trees species
as specified ( Alstonia scholaris, Erythrina
indica, Jacaranda mimosifolia,Delonix regia
Anthocephalus cadamba, Spathodea
companulata,Neem (Azadirachta indica),
Lagerstromia speciosa , Tabebuia argentea,
Cordia sebestena, Mimusops elengi, Bauhinia
blakeana, Kigelia pinnata, Cassia fistula,
Banyan, Ficus religiosa, Peltophoroum, Bottle
brush, Silver Oak, Billi, Mahagony, Pendula,
Desi Asopalav,Sevan, Badam, Ficus infectoria,
Pinkesiya, Millingtonia hotensis, Rain Tree,
Bakm limdi, kasid, Ashok tree, parkia, Tabebuia
Rosea, millettia, etc.) having height of minimum
7.00 to 8.0 ft. and bag size is 13 inch x 13 inch,
well branched, well established & free from
11 100 disease at site as per the instructions. 250.00 Nos
Supplying insecticides at site well packed in
bottle of 20 litre. weight including royalty and
carriage with all leads and lifts (product to be
12 50 brought in company sealed packing only) 300.00 20 L Bottle
I. No. Qty Items Unit Rate Per Amount
Furniture Work ( Curtains and Cupboard
Supply of Steel Locker with 18 Nos. of Locker,
Steel Trainee Locker having size 78" x 36" x 18"
made from powder coated 20 gauge CRCA
steel sheet, godrej lock, high quality handle. As
1 32 per sample approved by department. 8694.92 No.
Supply of Midium back revolving chair having
denim blue color, 12 mm BWR grade ply, L ply
frame, 45 mm mold sheet back, fibre base27"
custer(Nylon), Hidrolic Mechanism etc comp.
2 10 As per sample approved by department. 3364.41 No.
Supply of Officer Table( Single Mobile Drower
Unit) Size-66"x30"x30", 36 mm post form
Formika top and 42 mm post form Formika side
made from ISI grade MDF board, wirh keyboard
tray and apron, Mobile Drower Unit- size,
18"x21"x27" made from Post Form ISI grade
MDF board unit with three drower, handle, lock,
high quality channel. As per sample approved
3 1 by department. 12652.54 No.
Providing & Fixing Sun Control Reflective Type
Film / Frosted Film as Selected by Architect/
Engg. In Charge For Glass Doors / Windows
4 150 etc. as Directed. 646.37 Sq.mt.
Providing & Fixing in Position Vertical Roller
Blinds with Minimum 3 % and Maximum 5 %
Light Transperace Screen Fabric Incuding
Providing & Fixing of Powder coated G-
Channel at the Topof Window with necessary
Screw , Cleats etc. and PVC Roller ( Weight
Pipe) and PVC Chain For Up and Down
Movement of Blinds etc. of Approved Make and
as per Drawings / Instruction of Engg. in Charge
For All Colors and Shades. Rates Includes all
Lead and Lift For All Floor Level, All Height , All
Material , Accessories, Fixing , Scaffolding
Labor etc. Complete in All Respects. All
Required Accessories & Material must be From
5 150 Same Manufacturer. 1372.03 Sq.mt.
Total of Furniture Work ( Curtains and
Cupboard Shutter) Total Rs.
Signature of Bidder
Special Condition For Tenderers
• Scope includes Complete Demolition of Super Structure & Sub Structure up to
Foundation Level of Existing Old Buildings in the Said Plot Under Development as
Instructed by Engg. In Charge & Then Disposal of Serviceable & Un Serviceable
Material including Cleaning & Levelling of Entire Plot. The Total Project Includes
Demolition of Existing Units and Site Clearance. The Total Responsibility and
Liability of This Demolition Works Including Site Clearance Shall Be of The
Contractor. This Demolition and Debris Removal Includes all Hidden Foundation
also at Locations Where New Foundation or New Work is To Be Done.
• Contractor Has to Visit Site with representative of A.M.C. Before Quoting Amount in
Tender. The Contractor Shall Not Be Paid For Any Dismantling, Demolition, Carting
The Debris And/ or Any Expenses Incurred For Site Clearance.
• Contractor shall have to Pay Premium Amount to A.M.C. For Disposal of Serviceable
Goods Like Old Reinforcement, Old Wooden Doors/Windows, Iron Work,
Copper/Alu. Wiring, Bricks etc. Which shall be Quoted in Part-A of Financial Bid.
• For Consideration of Lowest Eligible Bidders , Premium Amount as Mentioned
Above i.e. Part-A shall be Deducted From e-Tender Amount For Construction Work
i.e. Part-B , Quoted by the Contractors.
• The Lowest Eligible Bidder shall have to Deposit Premium Amount for the
Serviceable Goods at the Time of Submission of Security Deposit.
Signature of contractor Additional City Engineer (building Project)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- BUILDING PROJECT
Name of Work : CONSTRUCTION OF SHELTER FOR URBAN HOMELESS (SUH) BUILDING AT F.P. NO. 71+72,
T.P.S.NO.2 (KANKARIA FIRST VARIED) IN KHADIYA WARD, CENTRAL ZONE, BUILDING PROJECT,
FINANCIAL BID (Online Only)
Demolition of Existing Structure
Sr.No. Description Amount
Quoted Premium Amount For Serviceable Material (Which is Payable to
1 A.M.C. at The Time of Depositing Security Deposit by the Lowest Eligible
Amount in Words Rupees :
Sr.No. Description Amount
1 Amount For Civil Work Rs.4,28,08,030.37
Amount For Annual Comprehensive Maintenance of Civil Work For 4 Years
After Completion of DLP of 1 Year
3 Amount For Electrical Work , ELV, Passenger Elevator Rs.
Amount For Annual Comprehensive Maintenance OF Electrical Work, ELV,
Passenger Elevator for 4 Years After Completion of DLP of 1 Year Rs.
5 Amount For Fire Fighting System Work Rs.
Amount For Annual Comprehensive Maintenance OF Fire Fighting System
Work for 4 Years after completion of DLP of 1 Year Rs.
7 Amount For Landscaping Work Rs.
8 Amount For Furniture Work ( Curtains and Cupboard Shutter) Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs. 5,66,84,954.44 Estimated cost put to tender : Rs.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Net Tender Amount For Consideration of Lowest Eligible Bidders
Sr.No. Description Amount
Net Amount For Cost of Civil , Electrical, Fire Fighting, Annual
1 Comprehensive Maintenance of Civil, Electrical and Fire Fighting Work,
Landscaping and Furniture Work i.e. Part-B Rs.
2 Quoted Premium Amount Payable to A.M.C. i.e. Part-A Rs.
3 Net Tender Amount i.e. (Part-B -
Net Tender Amount in Words Rupees :
Signature of contractor Additional City Engineer (Building project)
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Khadiya_SUH_DRAWING.pdf
Khadiya_SUH_ELEVATION.pdf
Khadiya_SUH_Notice_Inviting_Tender.pdf
Khadiya_SUH_Vol_1_part_A_Tender_Document.pdf
Khadiya_SUH_Vol_1_Part_B_TS_Civil_Work.pdf
Khadiya_SUH_Vol_1_part_C_Electrical_Specification.pdf
Khadiya_SUH_Vol_1_part_D_Fire_Fighting_Specification.pdf
Khadiya_SUH_Vol_2_Final_Price_Bid_Vol_II.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .