Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BYPASS NH NEAR SBI SIDHRA JAMMU | Admitted-Finance |
| 2 | Admitted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
16 Dec 2019, 4:30 pmClosed
Executive Engineer PHE Division Samba
PHE Division Samba, District Offices Complex Nandni Hills Samba
Please refer BOQ
2019_PHE_87630_1
PHES/61 of 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Samba
Please refer NIT
6 documents required · 6 mandatory
₹300
Executive Engineer PHE Division Samba
₹16,000
8 Jan 2020
7 Dec 2019
18 Dec 2019
8 Dec 2019
16 Dec 2019
8 Dec 2019
Amount
Providing, Installation, Testing and Commissioning of 1 No HC Pump set having Parameter 5000 GPH X 250 Mtr. Head at Filteration Plant Samba:
Carriage of pumping machinery set from the Firm store / Divsional Stre to worksite. Carriage of G.I. pipes and other allied material from Samba to work site. Job includes loading at Firm store and unloading at worksite. Stacking of material properly at worksite.
Laying of foundation block for the pump set. Job include digging a pit as per the required size. Laying the RCC block as per the PWD norms. Providing & fitting, Grouting & fixing of fabricated 6 No’s 3’x5/8’’ foundation bolts, placing the base frame on the block with proper levelling with the help of levelling instrument. Complete job includes cost of material and labour charges.
Placing the HC Pumpset on the top of the base frame manually with proper levelling by way of adding shims etc so that pump and motor can be coupled without any offset. Fitting of the pumpset by using heavy duty nuts, bolts and washers with proper alignment. The job includes the cost of material and labour Charges.
Fabrication of suction pipes of 3’’ dia by way of fabrication of 12mm thick M/S. Flange and fitting as per requirement at site. Providing and fitting of 3’’ dia G.I Pipe bends dully flanged as per requirement. P/F of 3’’ dia C.I Sluice valve of reputed make on suction pipe line by way of providing M.S. Flanges on its both ends. The job includes threading and welding of pipes with flanges .P/F of nuts, bolts and rubber gaskets. The complete job includes cost of material and labourcharges. ( G.I. Pipe will be provided by the department)
Fabrication of Delivery pipes of 3’’ dia by way of fabrication of 12mm thick M/S. Flange and fitting as per requirement at site. Providing and fitting of 3’’ dia G.I Pipe bends dully flanged as per requirement. P/F of 3’’ dia C.I Sluice valve of reputed make and 1 No 3’’ dia C.I reflex valve of reputed make on delivery pipe line by way of providing M.S. Flanges on its both ends. The job includes threading and welding of pipes with flanges .P/F of nuts, bolts and rubber gaskets. The complete job includes cost of material and labour charges. (G.I. Pipe will be provided by the department)
Fabrication of the panel board made out of angle iron and having a size 6’x3’.The angle iron is to welded at corner properly and flushed in all the directions including its grinding or foiling to avoid body scratches. The panel board is to be surmounted with the ply of 12 mm thickness with some other insulating material on the top. The board shall have two legs at the corners and two legs to be welded / grouted with the wall of the pump room.
Providing and fitting of 200 Amp. Main switch, HRC type 415 Volts, ISI mark and make proper electrical connections with LT Cable and PVC Cable. Complete job including cost of material and labour type.
Providing and fitting of Multistrand PVC cable ( copper ) of 35 sq mm from motor of new pump to Starter ( 6 leads) and from srtarter to main switch (3 Leads) .Also P/F of copper thimbles of adequate capacity, crimping of thimbles with crimping machine and taping of ends of PVC copper conductors. Complete job.Total Length=approx. 40 mtr
Providing and fitting of 80 HP starter (star Delta) Job includes filling of transformer oil in starter dash pot up to the required level. Fixing of starter on panel board with fasteners and making the required electrical connections.
Providing and fitting of 100 Amp MCCB ISI Mark, making connection with incoming Multistrand Cable from main switch and outgoing to starter for automatic tripping.
Providing, Fitting of Single Core 400mm² Aluminium LT Cable ( approx. 16 Mtrs), by way of replacing the old burnt LT Cable. Job includes dismantling the old LT cable after disconnecting all electrical connections from LT bushes to LT fuse box and fitting of new Single core cable and making all necessary electrical connections. Providing and fitting of thimbles as per required current carrying capacity and crimping of thimbles with crimping machine and taping of ends Properly.
Providing, Fitting and laying of 3.5 Core Armoured 120mm² Aluminium LT Cable (30mtrs) from LT fuse box to main switch. Job also includes Providing and fitting of thimbles as of required currentcarrying capacity. Rate to be quoted per meter of LT cable including cost of carriage and labour charges.
Painting of suction and delivery pipes with superior quality enamel paint after removing dust and other unwanted material from the surface.
Testing and commissioning of pump set on load. The job includes checking of alignment during operation of pump set, abnormal sound during operation, checking of leakage on suction and delivery side and plugging of the same thereafter providing and fitting of nuts and bolts, rubber sheet whenever required.
Rishabh Electricals and Mechanical Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .